Grease Interceptors. Design & Operation. Material & Characteristics

Similar documents
SECTION PLUMBING SPECIALTIES

A. This Section includes the following sanitary drainage piping specialties:

Grease Management. EnduraGreaseManagement.com. Rethinking Grease Interception

.2 Section Waste Management and Disposal

Incorrect sizing, improper installation and/or inefficient maintenance will affect the performance of Proceptor separators.

A. Codes and Standards that are standard at the University. C. Coordinate cleanout locations with Architect.

SECTION DRAINS AND CLEANOUTS. 1. Division 7 - Thermal and Moisture Protection Piping (Plumbing).

Limestone County Water & Sewer Authority

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

DRAINS AND CLEANOUTS. 1. Division 7 - Thermal and Moisture Protection Piping (Plumbing).

DRAINS AND CLEANOUTS. 1. Division 7 - Thermal and Moisture Protection Piping (Plumbing).

University of Delaware

A. Provide floor drains in all restrooms placed a minimum of 7 from back of wet wall, janitor closets, and mechanical rooms.

Ice Rink Renovation & New Clubhouse

A. Codes and Standards that are Standards at the University. A. Provide floor drains in all toilet rooms, janitor closets, and mechanical rooms.

D. Encase exterior cleanouts in concrete with access cover installed flush with grade.

INSTALLATION GUIDE. Model #PP2 Pumpout Port Kit For Use with Grease Interceptors Models GB-50, GB-75 and GB-250. Contents

GB-25. Submittal Special Precautions Specifications Installation Application Specific Details

SECTION SANITARY WASTE INTERCEPTORS

GB-20. Submittal Specifications Installation Application Specific Details

GB-75. Submittal Specifications Installation Application Specific Details

Student Services & Classroom Addition. A. This Section includes the following sanitary drainage piping specialties:

Union County Vocational - Technical Schools Scotch Plains, New Jersey. A. This Section includes the following sanitary drainage piping specialties:

SECTION PLUMBING SPECIALTIES

GB-75. High Efficiency Grease Interceptor Technical Data. Submittal Specifications Installation Application Specific Details

GBHF Submittal Special Precautions Specifications Installation Application Specific Details

GB-50. Submittal Special Precautions Specifications Installation Application Specific Details

FLOOR AND AREA DRAINS

City of Muskogee Pollution Control Department POLICY STATEMENT FOR GREASE AND OIL CONTROL

GB-75. Submittal Special Precautions Specifications Installation Application Specific Details

PLUMBING BASIC MATERIALS AND METHODS 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS

CONTINUED ON FOLLOWING PAGE

ROOF DRAINS TABLE OF CONTENTS

INTERCEPTORS SELECTION GUIDE. Construction / Operation GREASE OIL OIL / SEDIMENT SAND SOLIDS HAIR LINT FUR

REQUEST FOR DEVIATION WATER AND WASTEWATER SYSTEM STANDARD SPECIFICATIONS

Read Only Copy Not For Distribution. Chapter 17. Private Potable Water Supply Systems 17.1 GENERAL REGULATIONS 17.2 QUANTITY OF WATER REQUIRED

INSTRUCTIONS FOR THE ASSEMBLY AND INSTALLATION OF THE VORTOX LIQUID SAMPLER

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

SV24. Submittal Special Precautions Specifications Installation. 12½" (31.8 cm) 12½" (31.8 cm) 12" (30.5 cm) 12" (30.5 cm) 12" (30.

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING. A. This Section includes the following storm drainage piping specialties:

MIFAB SAMPLE FIXTURE SCHEDULE & SPECIFICATIONS

Student Services & Classroom Addition. A. This Section includes the following domestic water piping specialties:

1.04 SUBMITTALS PLUMBING FIXTURES

AWI MANUFACTURING. Quality Products Since USDA Certified. Stainless Steel Floor Drains

Lifetime Guaranteed Construction with unique built-in installation and maintenance features

FREQUENTLY ASKED QUESTIONS

PUMPS AND ACCESSORIES. Residential Fixtures Bathing Commercial Fixtures Faucets Accessories

SECTION SANITARY WASTE INTERCEPTORS

Drainage. Specification Drainage Products 2013 Catalog and Price List. Effective June 1, watts.ca

STAINLESS PRODUCTS TRUSTED SOLUTIONS FLOOR DRAINS TRENCH DRAINS CLEANOUTS P-TRAPS HUB DRAINS FLOOR SINKS FLOOR TROUGHS CUSTOM SOLUTIONS

FS-DUO. Wastewater Flow Distributor Technical Data. Submittal Special Precautions Specifications Installation. (62.2 cm) (62.2 cm)

MIFAB Master Specification. Plumbing Drainage & Specialties - Specification For Commercial, Industrial & Institutional Facilities

SECTION PLUMBING PIPING

SECTION PIPING SPECIALS

ACO Building Drainage Products ACO Cast Iron Floor Drains with Nickel Bronze Tops ACO Cast Iron Cleanouts with Nickel Bronze Tops

.1 Capped for future connection by others. .2 Section Waste Management and Disposal.

.1 Capped for future connection by others. .2 Section Waste Management and Disposal.

SOUTHWEST METROPOLITAN WATER AND SANITATION DISTRICT. Fats, Oils, and Grease (FOG) Policy. (adopted September 17, 2010)

6 10ES COMBITHERM ITEM NO. additional product color. oven function. SHORT FORM SPECIFICATIONS: MODELS: STANDARD FEATURES AND ACCESSORIES

Fats, Oils & Grease (FOG) Management Policy

SECTION FACILITY SANITARY SEWERS

Recommended Amendments to the 2015 International Plumbing Code North Central Texas Council of Governments Region

GGI-750. Gravity Grease Interceptor Technical Data. Submittal Special Precautions Specifications Installation

Essex County College - West Essex Campus Addition And Renovations Dib # / SECTION DOMESTIC WATER PIPING SPECIALTIES

SECTION DRAINAGE AND VENT SYSTEMS CONSTRUCTION STANDARD

C. ASSE 1013 Performance Requirements for Reduced Pressure Principle Backflow Preventers.

2012 International Plumbing Code. Exhibit D

Table of Contents Rules Concerning Uniform Plumbing Code

CHAPTER 7 SANITARY DRAINAGE SYSTEMS

FS-TRIO. Wastewater Flow Distributor Technical Data. Submittal Special Precautions Specifications Installation. (62.2 cm) (62.

READ ONLY. Adopting Agency BSC SFM. Adopt Entire Chapter Adopt Entire Chapter as amended (amended sections listed below)

Industrial Pretreatment Program Grease Abatement Requirements for Food Service Establishments (FSEs)

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT. A. ASME B31.1 (American Society of Mechanical Engineers) - Power Piping

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS IAPMO GUIDE CRITERIA FOR

Diffused Aeration Piping Equipment

RESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION DOMESTIC WATER PIPING SYSTEM

CERTIFYING DRAINLAYER

1 ½

C-CF-0417 AHEAD OF THE FLOW. Copper Fittings

C-CF Copper Fittings

Canadian Catalogue & Price List

Join Lovelace Medical Clinic

DIVISION 22 PLUMBING SECTION INTERIOR SANITARY WASTE AND VENT PIPING SYSTEM

Amendments to the 2012 International Plumbing Code

Beacon Hill Water & Sewer District Standard Specifications

5.0 ENDURA GREASE MANAGEMENT. Endura Grease Interceptors with Spigot format Flow Control Devices.

Specification Drainage

Section FATS, OILS and GREASES CONTROL ORDINANCE A. Scope and purpose B. Definitions

TENOCHCA HALL - PROJECT NO FAN COIL UNITS, RESTROOM AND FINISH RENOVATION

INDUSTRIAL FILTRATION EQUIPMENT LWS Filter Series

SUPPLEMENT EXISTING SEPTIC SYSTEM INSPECTION REPORT WHO IS QUALIFIED TO PERFORM AN INSPECTION?

OIL/WATER SEPARATORS & GREASE INTERCEPTORS. Requirements for Oil/Water Separators and Grease Interceptors discharging into Kitsap County Sewer mains

University of Delaware

Level III Chapter 1 Worksheet

GGI-750. Gravity Grease Interceptor Technical Data. Submittal Special Precautions Specifications Installation

NORTH CAROLINA DEPARTMENT OF ENVIRONMENT, HEALTH AND NATURAL RESOURCES DIVISION OF ENVIRONMENTAL HEALTH ON-SITE WASTEWATER SECTION

Equipment Catalog. For inquiries and orders, please contact:

ROOF DRAINS AND ACCESSORIES

2007 WSSC PLUMBING AND FUEL GAS CODE AMENDMENT #2 OUTLINE OF CODE CHANGES

SECTION PLUMBING EQUIPMENT AND SPECIALTIES

Transcription:

Grease Interceptors Dormont offers a full line of grease interceptors for installation on cooking/prep sinks, pot, pan & scullery sinks and dishwasher applications. Dormont offers a variety of interceptor configurations including: on-floor, recessed with & without extension and recessed with access housing. Dormont grease interceptors are available with no-hub or threaded connections. Make Dormont your source for grease interceptors. Design & Operation Grease interceptors are designed to prevent greasy substances from entering plumbing systems, septic fields and wastewater treatment facilities, where they are difficult to process and can create a number of environmental problems. Grease interceptors are commonly specified in restaurant kitchens and food handling or processing areas to keep drainage systems free of problematic grease accumulations. Grease interceptors work by collecting all lighterthan-water substances, such as grease, inside the interceptor. This is accomplished through the use of a flow restrictor on the inlet side of the interceptor, which slows incoming effluent and redirects it through baffling inside the interceptor. This slowing and baffling process allows lighterthan-water substances to accumulate inside the interceptor above the static water line. Design criteria is determined by plumbing code and typically follows the guidelines set forth by the Plumbing & Drainage Institute (PDI), which tests and rates interceptors. The accepted industry and PDI standard (PDI-G101) is to maintain 90% separation efficiency, up to the rated grease retention capacity (in lbs.). Material & Characteristics Epoxy Coated Steel - Interceptor body standard 11 ga. CR steel, with oven cured, acid resistant baked gray epoxy coating, inside and out. Lid is epoxy coated 1 4" skid-proof checker plate steel, gasketted, and secured with Allen head center bolt(s). All stainless steel construction may be specified for high sanitary applications. Flow Restrictor - WD Series Interceptors are supplied with an external cast iron flow restrictor. All other interceptor models are designed with a built-in stainless steel flow restrictor plate, located just inside the inlet. 2

WD Series PDI Certified Grease Interceptors SPECIFICATION: Dormont WD Series PDI Certified recessed or floor mounted epoxy coated steel grease interceptor with gasketted solid steel cover, hex head center bolt(s), removable baffle assembly, deep seal trap with cleanout, no hub connections (standard), and external cast iron flow control fitting. Secured Non-slip Cover Neoprene Gasket Locking Device D x E Clean-out Plug Static Water Level Baked Epoxy Coated Body 3/8"(10) Air Space One-piece Removable Note: *Optional Threaded Inlet And Outlet (includes Threaded Flow Control) Air Relief By-pass No-hub (MJ) Inlet & Outlet (*) Integral Deep Seal Trap Fixed Sediment C IAPMO U P C TM Interceptor Catalog Number Flow Rate GPM Grease Capacity Lbs A Inlet & Outlet B Base to Center C Top to Center D Length E Width F Height WD-4 WD-7 WD-10 WD-15 WD-20 WD-25 WD-35 WD-50 4 7 10 15 20 25 35 50 8 14 20 30 40 50 70 100 2"(51) 2"(51) 2"(51) 2"(51) 3"(76) 3"(76) 3"(76) 4"(102) 7-3/4"(197) 8-1/2"(216) 8-1/2"(216) 10-1/2"(267) 11-1/2"(292) 16"(406) 3-1/4"(83) 3-1/2"(89) 3-1/2"(89) 3-1/2"(89) 3-1/2"(89) 4-1/2"(114) 5"(127) 5-1/2"(140) 16"(406) 18"(457) 21-3/4"(552) 22"(559) 24"(610) 26"(660) 30"(762) 32"(813) 10"(254) 13"(330) 15"(381) 15-3/4"(400) 16-1/2"(419) 18"(457) 22"(559) 11"(279) 15"(381) 16-1/2"(419) 19"(483) 21-1/2"(546) 3

WD-A Series Semi-Automatic Draw-Off Grease Interceptors SPECIFICATION: Dormont WD-A Series recessed or floor mounted epoxy coated steel semi-automatic draw-off grease interceptor with gasketted solid steel cover, hex head perimeter bolt(s), removable grease accumulating cover and baffle assembly, deep seal trap with cleanout, threaded connections (standard), internal stainless steel flow control fitting, flexible draw-off hose, and line shut-off valve. ALL SPECIAL ORDER Interceptor Catalog Number WD-7-A WD-10-A WD-15-A WD-20-A WD-25-A WD-35-A WD-50-A WD-75-A THREADED CONNECTION (STANDARD) Flow Rate GPM 7 10 15 20 25 35 50 75 Grease Capacity Lbs 14 20 30 40 50 70 100 150 A B C D Inlet & Base to Top to Outlet Center Center Length 2"(51) 8-1/2"(216) 3-1/2"(89) 2"(51) 8-1/2"(216) 3-1/2"(89) 2"(51) 10-1/2"(267) 3-1/2"(89) 3"(76) 11-1/2"(192) 3-1/2"(89) 3"(76) 4-1/2"(114) 3"(76) 5"(127) 4"(102) 16"(406) 5-1/2"(140) 4"(102) 18-1/2"(470) 5-1/2"(140) 18"(457) 21-3/4"(552) 22"(559) 24"(610) 26"(660) 30"(762) 32"(813) 36"(914) E Width 13"(330) 15"(381) 15-3/4"(400) 16-1/2"(419) 18"(457) 22"(559) 24"(610) F Height 15"(381) 16-1/2"(419) 19"(483) 21-1/2"(546) 24"(610) 4

WD-L Series PDI Certified Low-Rough-In Grease Interceptors SPECIFICATION: Dormont WD-L Series PDI Certified recessed or floor mounted epoxy coated steel low-rough-in grease interceptor with gasketted solid steel cover, hex head center bolt(s), removable baffle assembly, deep seal trap with cleanout, no hub connections (standard), and external cast iron flow control fitting. Secured Non-slip Cover Locking Device Neoprene Gasket Clean-out Plug Air Relief By-pass One-piece No-hub Removable (NH)(MJ) Inlet & Static Outlet (*) F Water B Level Integral Deep Seal Baked Epoxy Trap Coated Body Fixed Sediment Note: *Optional Threaded Inlet And Outlet 3/8"(10) (includes Threaded Flow Control) Air Space C SPECIAL ORDER Interceptor Flow Grease A B C D E F Catalog Rate Capacity Inlet & Base to Top to Length Width Height Number GPM Lbs Outlet Center Center WD-20-L 20 40 3"(76) 7-1/2"(191) 4-1/4"(108) 34-7/8"(886) 22-7/8"(581) 11-3/4"(305) WD-35-L 35 70 4"(102) 7"(178) 4-1/2"(114) 40-7/8"(1038) 32-7/8"(835) 11-7/8"(302) WD-50-L 50 100 4"(102) 8-1/2"(216) 5-1/2"(140) 55"(1397) 33"(838) NOTE: NOT PDI CERTIFIED 5

GI-K Series Large Capacity Grease Interceptors SPECIFICATION: Dormont GI-K Series recessed or floor mounted epoxy coated cold rolled steel grease interceptor with gasketted epoxy coated skid-proof top secured with hex head center bolt(s), no hub connections (standard), double wall deep seal trap, and integral stainless steel flow control. D (Length) x E (Width) A Stainless Steel Flow Control Plate Outlet C Removable F Double Wall Deep Seal Trap Interceptor Flow Grease A B C D E F Catalog Rate Capacity Inlet & Base to Top to Number GPM Lbs Outlet Center Center Length Width Height GI-75-K 75 150 4"(102) 18-1/2"(470) 4-1/2"(114) 39-3/4"(1010) 30-3/4"(781) 23"(584) GI-100-K 100 200 4"(102) 28-1/2"(724) 4-1/2"(114) 39-3/4"(1010) 30-3/4"(781) 33"(838) ALL GI-150-K 150 300 4"(102) 38-1/2"(978) 4-1/2"(114) 39-3/4"(1010) 30-3/4"(781) 43"(1092) SPECIAL GI-200-K 200 400 4"(102) 36-1/2"(927) 6-1/2"(165) 52"(1321) 34"(864) 43"(1092) GI-250-K 250 500 4"(102) 39-1/2"(1003) 6-1/2"(165) 52"(1321) 34"(864) 46"(1168) ORDER GI-300-K 300 600 6"(152) 38"(965) 10"(254) 76"(1930) 48"(1219) 48"(1219) GI-400-K 400 800 6"(152) 42"(1067) 10"(254) 83"(2108) 55"(1397) 52"(1321) GI-500-K 500 1000 6"(152) 53"(1346) 10"(254) 91"(2311) 60"(1524) 63"(1600) 6

Sizing Chart Grease interceptors are sized according to the rate of incoming flow, in gallons per minute (GPM). Associated with the incoming flow rate is an interceptor's capacity. The rated capacity, in lbs., is listed at twice the flow rate, in GPM. For example, a 10 GPM interceptor has a rated capacity of 20 lbs General Procedure: To Determine the Flow Rate of Each Sink: 1. Calculate the capacity of the sink in cubic inches: (LENGTH) x (WIDTH) x (DEPTH) = CU.IN. 2. Convert the capacity from cubic inches to gallons per minute (GPM): CU.IN. 231 = GPM. 3. Adjust for displacement: GPM x 0.75 = GPM. 4. Result is the flow rate required to drain the sink in one minute.* *Note: If drain down time is not critical, an interceptor with a lesser flow rate, up to half the calculated flow rate may be specified. Example: Three compartment pot sink, each compartment 12" x 12" x 15" 1. 12" x 12" x 15" = 2160 cu. in. x 3 comp. = 6480 cu. in. 2. 6480 cu. in. 231 = 28 GPM. 3. 28 GPM x 0.75 = 21 GPM. A 20 GPM interceptor would permit the sink to drain in slightly more than one minute. *Discharge from spray hoods is determined by the flow rate of the hood. Sizing For Multiple Fixtures: 1. Determine the flow rate for each fixture to be serviced by the interceptor. 2. Add together 100% of the largest flow rate, 50% of the second largest, and 25% of all others. 3. Result is the recommended flow rate of the interceptor. Example: 1. Fixture A: 35 GPM Flow Rate Fixture B: 26 GPM Flow Rate Fixture C: 18 GPM Flow Rate Fixture D: 12 GPM Flow Rate 2. 35 GPM (A) x 100% = 35 GPM 26 GPM (B) x 50% = 13 GPM 30 GPM (C + D) x 25% = 7.5 GPM Total Flow Rate = 55.5 GPM A 50 GPM interceptor is recommended for this installation. Typical Configurations SINK AIR INTAKE VENTED WASTE SINK AIR INTAKE VENTED WASTE SINK AIR INTAKE VENTED WASTE FLOW CONTROL TEE FLOW CONTROL TEE FLOW CONTROL TEE ON FLOOR RECESSED RECESSED WITH EXTENSION 7

Distributed by: Dormont Manufacturing Company: 6015 Enterprise Drive, Export, PA 15632 1-800-376-6668 www.dormont.com A Subsidiary of Watts Water Technologies, inc. Watts 2004 GRESEPT, Rev. 1, 4-06