Floor Truss Ribbon Board Load Path

Similar documents
Floor Truss Ribbon Board Load Path. Overview Revised 3/24/2017

PHOTO 1: View from Inside the Structure. Note the Rotation of the WSP, Failure at the Lower Leading Edge and Deformation of the Top Plate

Individual Truss Marking Is it a Building Code Requirement?

Attachment of Residential Deck Ledger to Metal Plate Connected Wood Truss Floor Systems

Changes in the 2007 Supplement to the 2006 International Building Code That Affect Component Manufacturers

Impact of C&C loads due to ASCE/SEI Overview Revised 3/23/2017

Long Span Truss Installation

Heel Blocking Requirements and Capacity Analysis. Overview Revised 3/22/2017

Bottom Chord Live Load Concurrency and Truss Design. Overview Revised 6/13/2017

STRUCTURAL ISSUES IN RESIDENTIAL CONSTRUCTION. Presented by: Susan L. Lasecki P.E., S.E.

Exterior Brick Masonry Veneer Supported by Metal Plate Connected Wood Trusses. DD No

Wood Shear Wall Design Examples For Wind

Prescriptive and Engineered Design Provisions of the Massachusetts One- and Two-Family Dwelling Code

Originally Issued: 03/31/2017 Valid Through: 04/30/2018

North Shore at Canton Baltimore, MD Beau Menard Technical Report 1

Live Load Considerations for Truss Bottom Chords

What is Conventional Construction?

Stanley Fastening Systems, L.P. Stanley BOSTITCH Pneumatic Pins. TER No

KERTO HEADER INSULATED LVL HEADER 31/2", 51/2" 3 1/2" AND 5 1/2" THICKNESSES DESIGN VALUES USA

Details for Exterior Brick Masonry Veneer Supported by Metal Plate Connected Wood Trusses

Exterior Brick Masonry Veneer Supported by Metal Plate Connected Wood Trusses (MPCWT) Design Guide Revised 11/17/2016

Prepared for Forest Product Laboratory, Forest Service, U.S. Department of Agriculture Norbord Inc., Toronto, Ontario, Canada

Considerations for Outof-Plane. Design

BASF HP+ Wall XR Series Limit States TER No

130 MPH EXPOSURE B WFCM GUIDE. Guide to Wood Frame Construction in High Wind Areas for One- and Two-Family Dwellings 2015 EDITION

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi

TYPICAL BEARING WALL FRAMING Joints in plates must be offset by 24 min.

Section Downloads. Background. Load Development Outline. Types of Loads ANSI/ASCE 7. Section 07: Load Development. Download & Print. Version 2.

2012 IRC Wood Wall Bracing

WFCM 120 MPH GUIDE EXPOSURE B WOOD FRAME CONSTRUCTION MANUAL GUIDE TO WOOD CONSTRUCTION IN HIGH WIND AREAS FOR ONE- AND TWO-FAMILY DWELLINGS

WFCM 130 MPH GUIDE EXPOSURE B WOOD FRAME CONSTRUCTION MANUAL GUIDE TO WOOD CONSTRUCTION IN HIGH WIND AREAS FOR ONE- AND TWO-FAMILY DWELLINGS

ReWall EssentialBoard, NakedBoard & Ceiling Panels TER No

sheathing) fastened between four flatwise SPF stud grade 2x4s.

Attachment A. USG Minimum Design and Construction Requirements for Wood Framed Structures

WFCM 110 MPH GUIDE EXPOSURE B WOOD FRAME CONSTRUCTION MANUAL GUIDE TO WOOD CONSTRUCTION IN HIGH WIND AREAS FOR ONE- AND TWO-FAMILY DWELLINGS

WFCM 100 MPH GUIDE EXPOSURE B WOOD FRAME CONSTRUCTION MANUAL GUIDE TO WOOD CONSTRUCTION IN HIGH WIND AREAS FOR ONE- AND TWO-FAMILY DWELLINGS

GARAGES/ONE-STORY City of Grand Rapids Building Safety Division

WFCM 130 MPH GUIDE EXPOSURE B WOOD FRAME CONSTRUCTION MANUAL GUIDE TO WOOD CONSTRUCTION IN HIGH WIND AREAS FOR ONE- AND TWO-FAMILY DWELLINGS

WFCM 90 MPH GUIDE EXPOSURE B WOOD FRAME CONSTRUCTION MANUAL GUIDE TO WOOD CONSTRUCTION IN HIGH WIND AREAS FOR ONE- AND TWO-FAMILY DWELLINGS

Table 3. Detailed Comparison of Structural Provisions of IRC 2000 and 1997 NEHRP (Continued)

City of Bemidji Building Office City Hall 317 4th Street NW Bemidji, Minnesota Phone Fax emi mn s

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP FABRICATED WOOD TRUSSES REPORT HOLDER: BARRETTE STRUCTURAL DISTRIBUTION, INC.

WTCA 6300 Enterprise Lane Madison, WI / / (fax)

Exterior Brick Masonry Veneer Supported by Metal Plate Connected Wood Trusses (MPCWT) Overview Revised 11/17/2016

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: ENERCEPT, INC.

Murphy LVL Limit States Design Guide 2.0 E-LVL 2.2 E-LVL

Fire Retardants and Truss Design. Overview

6.0 TUTORIAL. Cascade Consulting Associates, Inc. PO Box 1617 Corvallis, Oregon 97339

COPYRIGHT MATERIALS. Wind Solutions - Perforated Wood Structural Panel Shear Walls (DES 416)

PRODUCT: Structural Insulated Panels (SIP) DIVISION: Wood and Plastics (06) SECTION: Structural Panels ( )

Typical Deck. CONSTRUCTION TIP SHEET 5 Basic Decks w/ 60 lb Live Loading

Versetta Stone Panelized Stone Veneer Applications Over Continuous Insulation. TER No Boral Stone Products LLC

MAT109: Introduction to the Wood Frame Construction Manual

Floor Vibration: Causes and Control Methods. Overview Revised 2/2/2017

Introduction: Issue: Analysis/Conclusion:

Shear Wall Design Examples per 2015 WFCM and 2015 SDPWS

Chapters 4 through 10 address the prescriptive methods. Building Construction PART. Chapters 4 through 10

Special Floor Loading Considerations in Typical Residential Construction. Overview Revised 3/24/2017

research report Cold-Formed Steel Gable End Wall Design Using the Prescriptive Method for One and Two Family Dwellings RESEARCH REPORT RP05-2

LVL Product Guide 2.0E LVL 1.5E LVL

Truss Heel Heights and Energy Code Requirements. Overview Revised 2/17/2017

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: EVALUATION SUBJECT: STRUCTURAL PANELS

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP FABRICATED WOOD TRUSSES REPORT HOLDER: BARRETTE STRUCTURAL DISTRIBUTION, INC.

STD302: Wood Frame Construction Manual 2001 National Edition

SECTION R614 STRUCTURAL INSULATED PANEL WALL CONSTRUCTION

Trusted WOOD I JOISTS SECTION: 06 ON WEB i. Conformity! ICC-ES Evaluation. Copyright 2015

PRODUCT: Structural Insulated Panels (SIPs) DIVISION: Wood and Plastics (06) SECTION: Structural Panels ( )

POST AND FRAME STRUCTURES (Pole Barns)

Typical Deck. CONSTRUCTION TIP SHEET 5 Basic Decks w/ 60 psf Live Loading

WOOD I-JOIST AWARENESS GUIDE

Frame Wood Systems. Prepared for Forest Product Laboratory, Forest Service, U.S. Department of Agriculture National Association of Home Builders

Frame Wood Systems. Prepared for Forest Product Laboratory, Forest Service, U.S. Department of Agriculture National Association of Home Builders

Evaluation of the High-Heel Roof-to-Wall Connection with Extended OSB Wall Sheathing

Common Errors in Truss Design

Structural Criteria for Residential Rooftop Solar Energy Installations

Structural Criteria for Residential Rooftop Solar Energy Installations

CALCULATING WIND LOADS ON LOW-RISE STRUCTURES PER 2015 WFCM ENGINEERING PROVISIONS (STD342-1)

PRODUCT: Structural Insulated Panels (SIPs) DIVISION: Wood, Plastics, and Composites (06) SECTION: Structural Panels ( )

Preventing a Floor Truss Ban in Ohio. SBCRI/Qualtim TER Produces A Win for All Component Manufacturers (CMs)

Building and Safety Division 245 E Bonita Avenue Ph:

2012 Wood Frame Construction Manual: Wind Load Distribution on Buildings Load Paths

Streamline Solar Photovoltaic Structural Criteria for Residential Rooftop Solar Energy Installations (Streamline Solar Form 5)

Position Statement on Sealed Truss Placement Diagrams for Projects in the State of California

FIGURE R502.2 FLOOR CONSTRUCTION

ESR-2894 Reissued April 2014 This report is subject to renewal April 1, 2016.

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICES EVALUATION CRITERIA FOR

Load Design Charts. R-CONTROL SIPs STRUCTURAL INSULATED PANELS. CONTROL, NOT COMPROMISE.

Dead Load Weight of Roof Trusses. Dead Load Weight of Floor Trusses

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD I JOISTS REPORT HOLDER: STARK TRUSS COMPANY, INC.

Structural Criteria for Residential Rooftop Solar Energy Installations

Structural Criteria for Residential Rooftop Solar Energy Installations

Tall Wall Applications Challenges. Products Design Considerations Framing Details Fire Assemblies Innovative Solutions. Residential Construction

CODE ACTION AMENDMENTS

Fire Resistance Rated Truss Assemblies. Educational Overview

Structural Criteria for Residential Rooftop Solar Energy Installations

POST AND FRAME STRUCTURES (Pole Barns)

Jackson Crossing Located in Alexandria, VA. Technical Report 1 Michael Bologna

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD I JOISTS REPORT HOLDER: NORDIC ENGINEERED WOOD

GARAGE MAIN FLOOR PLAN

International Building Code/International Residential Code Inspection & Quality Assurance Requirements for Metal Plate Connected Wood Trusses

Transcription:

Floor Truss Ribbon Board Load Path SRR No. 1506-16 Structural Building Components Association (SBCA) July 26, 2016 SBCA is an APPROVED SOURCE This research report is based on practical scientific research (literature review, testing, analysis, etc.), with the goal of supporting strategic needs for code and standards development and market expansion. This research report complies with the following sections of the building code: IBC Section 104.11.1 and Section 1703.4.2 "Research reports. Supporting data, where necessary to assist in the approval of materials or assemblies not specifically provided for in this code, shall consist of valid research reports from approved sources." IBC Section 202 "APPROVED SOURCE. An independent person, firm or corporation, approved by the building official, who is competent and experienced in the application of engineering principles to materials, methods or systems analyses." Structural Building Components Association (SBCA) 6300 Enterprise Lane, Madison, WI 53719 608-274-4849 sbcindustry.com Copyright 2016

Table of Contents Introduction:... page 3 Testing:... page 4 Testing Results:... page 4 Assumptions:... page 5 Analysis:... page 6 Conclusion:... page 7 References:... page 7 Appendix A... page 8

Introduction: SBCA Research Report Recently a question was asked as to the need for intermediate blocking between wall bottom plate(s) and bearing walls in installations where walls are installed on top of bottom chord bearing floor trusses using a ribbon board as shown in Figure 2.15a of the Wood Frame Construction Manual 2012. (Note - Figure 2.15a refers to the ribbon board as Band ; see Figure 1 below). Currently, the capacity of a ribbon board and its system through the composite of the ribbon board, floor sheathing and bottom plate of the wall has not been ascertained. In order to provide better guidance, a series of tests were conducted at the Structural Building Component Research Institute (SBCRI) in order to determine the capacity of the ribbon board system. Figure 1: WFCM 2012 Figure 2.15a SRR No. 1506-16 Page 3 of 8

Testing: SBCA Research Report Floor truss end sections assembled with ribbon boards, 23/32ʺ floor sheathing, and 2x4 wall bottom plates were tested. Each tested assembly was loaded from above to simulate the wall load on each stud as shown in Figure 2. 2x4 and 2x6 ribbon board assemblies were tested without using construction adhesive to attach the floor sheathing. An additional set of 2x4 ribbon board assemblies was tested with the floor sheathing installed using construction adhesive. Testing Results: Figure 2: Ribbon Board System Testing Average maximum loads for each of the three test configurations is shown in Table 1. Ribbon Board Assembly Test Results Ribbon Board Size Floor Sheathing Size Floor Sheathing Glued Average Maximum Load (lbs) Average Maximum Load (PLF) Maximum Allowable Load w/ Safety Factor of 2.0 (PLF) 2x4 23/32ʺ No 14,569 3,642 1,821 2x4 23/32ʺ Yes 15,457 3,864 1,932 2x6 23/32ʺ No 17,894 4,474 2,237 Table 1: Test Results SRR No. 1506-16 Page 4 of 8

Assumptions: SBCA Research Report Construction The configuration for this analysis is assumed to be 36ʹ clear span roof trusses with 24ʺ overhangs spaced at 24ʺ on-center. These dimensions are based on the maximum span for prescriptive framing. Lumber species used throughout the construction of the roof, wall and floor is assumed to be either SPF, HF, DF or SP. The roof trusses are assumed to be bearing on a 10ʹ tall by 3 1 /2ʺ deep stud wall with stud spacing at 24ʺ on-center. The walls are assumed to have a minimum double 2x4 top plate and a minimum single 2x4 bottom plate which have design values equal to or greater than visually graded No. 2 lumber. Additionally, the ribbon board is assumed to be constructed of minimum 2x4 material which has design values equal to or greater than No. 2 visually graded lumber. See Figure 3 for additional information regarding construction requirements. Figure 3: Construction Requirements SRR No. 1506-16 Page 5 of 8

SBCA Research Report Loading To provide a general analysis that will be applicable to a majority of situations encountered in the continental US, certain assumptions were made, which are listed in Table 1. Loading for the purpose of analyzing the capacity of the ribbon board was based on standard loads from the IRC 2012 and lumber design values from the NDS 2015, as shown in Table 2. Description Ground Snow Load Top Chord Dead Load Bottom Chord Dead Load Maximum Roof Truss Span Maximum Roof Overhangs Maximum Stud Spacing Maximum Wall Height Wall Dead Load Lumber Species Sheathing Requirements Enclosure Category Construction/Loading Assumptions Value Assumed 70 PSF 10 PSF 10 PSF 36ʹ 2ʹ 2ʹ On-center 10ʹ 10 PSF SPF, HF, DF and/or SP Interior Gypsum Wall Board and/or Exterior structural wood sheathing installed per IRC 2012 Importance Factor, I 1.0 Thermal Factor 1.1 Exposure Category Exposure Factor 1.0 Table 1: Assumptions II C Analysis: Per ANSI/TPI 1-2014 section 7.5.2.1 (Figure 4), all loads being applied from roof trusses to wall and wall to ribbon board are considered to be applied as uniform PLF loads. All roof and wall loads are assumed to be uniform with no concentrated loads on the trusses or walls present. With the assumptions established in Table 1, the load carried by the ribbon board can be determined using ASCE 7-10 (see Appendix A for calculations used). The 36ʹ roof will apply a load of 1478 PLF to each wall. The dead load of the wall will increase the load 100 PLF given a 10ʹ tall wall. The combination of the roof load and wall load applies a load of 1578 PLF to the bottom plate of the wall, into the floor sheathing and then to the ribbon board. The tested allowable load for the combined section of the wall bottom plate, ¾ʺ structural floor sheathing and the 2x4 ribbon board with no glue used to attached the floor sheathing is 1821 PLF, greater than the 1578 PLF required. Figure 4: ANSI/TPI 1-2014 Section 7.5.2.1 SRR No. 1506-16 Page 6 of 8

Conclusion: SBCA Research Report From these calculations, it can be determined that intermediate blocking under all wall studs as shown in Figure 2.15a of the Wood Frame Construction Manual 2012 is not required given the loading and construction requirements do not exceed the assumptions shown in Table 1. Any project specific variables that reduce the loading, as well as better materials, will make the strength of the composite wall bottom plate, floor sheathing and ribbon board more conservative. Situations that exceed the assumptions shown in Table 1 such as concentrated loads or portal frames will require special considerations for proper support. It is the responsibility of the building designer to verify the capacity of all structural interfaces. References: American Society of Civil Engineers, Minimum Design Loads for Buildings and Other Structures (ASCE/SEI 7-10). American Wood Council, National Design Specification for Wood Construction (AWC/NDS), 2015. American Wood Council, Wood Frame Construction Manual for One and Two-Family Dwellings (WFCM), 2012. International Code Council, International Residential Code (IRC), 2012. American National Standard, National Design Standard for Metal Plate Connected Wood Truss Construction (ANSI/TPI 1-2014) Structural Building Components Association (SBCA), SBCRI-16-0120 Ribbon Board Assembly Vertical Load Testing, 2016. SRR No. 1506-16 Page 7 of 8

SBCA Research Report Appendix A Calculations for Loading P f = 0.7*C e *C t *I s *P g = 0.7*1*1.1*1*70 = 53.9 Lt R = SP R = ( (53.9+10+10)(36+2+2) )/2 = 1478 PLF Lt W = SP W = 10 * 10 = 100 PLF SL = Lt R + Lt W = 1478 + 100 = 1578 SRR No. 1506-16 Page 8 of 8