Does Heart Rate Predict Energy Expenditure? Yes, But..

Similar documents
Validating and Testing Wearable Sensors to Assess Physical Activity and Sedentary Behavior in the Center for Personalized Health Monitoring

Articles in PresS. J Appl Physiol (March 3, 2016). doi: /japplphysiol

Open Access Based on SWA Sensor Energy Consumption Under the Sports Fitness and Strength of the Correlation Research

Reproducibility and Variability of the Conconi Test Analysis

Comparison of heart rate measured by Polar RS 400 and ECG, validity and repeatability.

F: [ml min -1 ] = (BW [kg]) (PO at

Cardiorespiratory fitness estimation in free-living using wearable sensors

%VdotO 2 max as Physical Load Indicator Unit in Forest Work Operation

GCC 100 DAY JOURNEY BASELINE REPORT START DATE: 25 MAY 2016 THE UNIVERSITY OF NEW SOUTH WALES

Heart rate sensors acceptability: data reliability vs. ease of use

Session 5. Organizing database

Urban Transportation Planning Prof Dr. V. Thamizh Arasan Department of Civil Engineering Indian Institute Of Technology, Madras

Assessment of free-living physical activity (PA) has

A review of accelerometry-based wearable motion detectors for physical activity monitoring

The Accuracy of Wrist-worn Heart Rate Monitors across a Range of Exercise Intensities

Quick Start TIME mode Set Time... 4 Set Alarm... 5

NOTICE. (Formulated under the cognizance of the CTA R6.4 Health & Fitness Technology Subcommittee.)

Ergonomics Evaluation of Single Row Power Weeder for Rice

Abstract Objective: This thesis deals with the prototypical implementation of activity zone monitoring using the mobile phone. It uses the mobile

Participant Guide To Wellness

VALIDATION OF WEARABLE BIOFEEDBACK TECHNOLOGY FOR HEART RATE TRACKING VIA REFLECTIVE PHOTOPLETHYMOGRAPHY. A Thesis. Presented to the.

10.2 Correlation. Plotting paired data points leads to a scatterplot. Each data pair becomes one dot in the scatterplot.

Linking Food Availability and Waste in the Global Economy

DESIGN FOR ERGONOMICS: CHAIR DESIGN FOR AGEING EMPLOYEES

A Comparison of Calculated and Subjective Thermal Comfort Sensation in Home and Office Environment

Bivariate Data Notes

Original Article. Validation of four indirect VO2max laboratory prediction tests in the case of soccer players

Quality Management. Efficient Quality Management in a Regulated Environment

SPORT AND COACHING PRINCIPLES

COMPARISON OF THE 3 BIKE TEST WITH THE ASTRAND BIKE TEST BY VO 2 MAX

Statistics: Data Analysis and Presentation. Fr Clinic II

GPS Tour User Manual. Introduction. Getting Started. Step 1) Know your Watch:

COMFORT MODEL FOR LOCAL COOLING. Yufeng Zhang 1 and Rongyi Zhao 2. Beijing, , P.R. China

IEEE JOURNAL OF SELECTED TOPICS IN SIGNAL PROCESSING, VOL. XX, NO. YY, MARCH

Relationship Between Workplace Productivity and Physical Activity Among an Employed. Healthcare Workforce. Dané Marie Standish.

Fundamentals Level Skills Module, Paper F5. 1 Edward Limited. (a)

Kristin Gustavson * and Ingrid Borren

GCC 100 DAY JOURNEY. Final Report UNIVERSITY OF WOLLONGONG

Continuous, non-invasive core body temperature measurements for the next generation of fitness and health wearables.

SAMPLE 100 DAY JOURNEY GLOBAL FINAL REPORT

Exclusive GCC Distributor for Soleus

Heat Transfer and Heat Capacity

THE CITY OF NIAGARA FALLS FIRE DEPARTMENT VOLUNTEER FIRE FIGHTER RECRUITMENT GUIDE

DELIVERED ADDED VALUE

MECHANICAL PROPERTIES OF FRP UNDER IMPACT LOADS. Impact is a sudden application of an impulsive force to a structure. Almost all civil engineering

Foam with Biocrystal mixture

Cost Accounting The Foundation of Management Control

Miniaturized electronic packaging for wearable health monitors

A thermal physiological comparison between two Explosives Ordnance Disposal (EOD) suits during work related activities in moderate and hot conditions.

CHM-202 General Chemistry and Laboratory II Laboratory 2 Molar Mass by Freezing Point Depression

COMPUTER SIMULATION OF ENZYME KINETICS

Mobile Human Data from Real People in Real Environments

Work System Design Dr. Inderdeep Singh Department of Mechanical and Industrial Engineering Indian Institute of Technology Roorkee

100 MILE SPORTIVE EVENT

WhaleTeq Co., Ltd Company Profile and Introduction

Chapter 3. Chapter Outline. Ergonomic Principles and Risk Assessment

i. The profit maximizing output of firm B is smaller than the profit maximizing output of firm A.

Quick Start TIME mode Set Time... 4 Set Alarm... 5

BCHS Curriculum Map

PERSONAL FITTING PROCEDURE FOR CYCLE ERGOMETER WORKLOAD CONTROL BY ARTIFICIAL NEURAL NETWORKS T. Kiryu 1, K. Shibai 1, Y. Hayashi 2, and K.

Assessment of Physical Activity Using Wearable Monitors: Recommendations for Monitor Calibration and Use in the Field

RFP # TITLE: Campaign to Prevent Childhood Obesity

White Rose Research Online

Manual Materials Handling

Gender Pay Gap Report 2018

The measurement of oxygen consumption ( _VO2)

Ergo-Economical Analysis of Different Paddy Transplanting Operations in Eastern India

Which is the best way to measure job performance: Self-perceptions or official supervisor evaluations?

2) For years, the country of Yemen has seen dramatic reductions in death rate. Over the past few years, the birth rate has also begun to drop.

A Case Study on Stress Management of Women

NATIONAL CAREER DEVELOPMENT GUIDELINES Overview

A is used to answer questions about the quantity of what is being measured. A quantitative variable is comprised of numeric values.

Making Sense of Data

PARTICIPANT REPORT. Legacy Leadership Competency Inventory. HRDQ Sample Report. Legacy Leadership Competency Inventory, Self-Rated Version

Work patterns of tanker-based bushfire suppression by Australian volunteer firefighters in south-east Australia.

Screening Score Report

The use of isothermal calorimetry in cement production. Paul Sandberg

FITNESS Performance Testing

Instruction Manual SH011. Pulse Rhythm BLE Optical HRM watch. How to wear the watch properly in your forearm: Push Button location / Main function

Single Pulse Resistance Welder Instruction Pamphlet CD125SP High Accuracy CD Welder

Multiple Choice (#1-9). Circle the letter corresponding to the best answer.

Higher National Unit specification: general information

Laboratory 3 Factorial Experiment: Paper Helicopter Design

Interviewing A Verbal Minefield

Student Questionnaire - Advanced Mathematics

The European Charter for Researchers and The Code of Conduct for the Recruitment of Researchers (C&C)

9 Vital Leadership Behaviors That Boost Employee Productivity

SAMPLE REPORT. Desktop Support Benchmark. Outsourced Desktop Support DATA IS NOT ACCURATE!

Session 7. Introduction to important statistical techniques for competitiveness analysis example and interpretations

Scoring Road Stream Crossings as Part of the North Atlantic Aquatic Connectivity Collaborative (NAACC)

DIGITAL INTERACTION & MODERN COMMUNICATION Information overload and digital complexity in 2016

Measuring Enthalpy to Calculate Efficiency Application Note Summary. 2 Introduction. 3 What to Measure.

SAMPLE REPORT. Desktop Support Benchmark DATA IS NOT ACCURATE! Outsourced Desktop Support

The Impact of Street Advertising on Physical Activity, Sedentary Behavior and Weight Among Youth

where m is the mass of the water, c is the specific heat of water (1 cal/g C), and T is the change in temperature of the water.

Prime Performance Modeling. Changing the face of modeling through superior techniques

Chapter 6: Customer Analytics Part II

Energy savings reporting and uncertainty in Measurement & Verification

Thermal Environment evaluation in Commercial kitchens: Procedure of data collection

L. Wittmersl, C. Taborl, K. Canine2 & J. Hodgdon2

Transcription:

N : 01-2006 Date : Oct 2006 Does Heart Rate Predict Energy Expenditure? Yes, But.. J Farringdon & D Wolf. BodyMedia Inc. Autumn 2006. There is a common assumption regarding the ability of heart rate monitors to predict energy expenditure. This is partly because there are many consumer products available that attempt to do just that, for example heart rate chest-strap monitors with wrist watches or software that estimate calories burnt. Plus there is literature that describes accurate energy expenditure estimation from heart rate recordings. However a closer look at the products and the literature shows that predicting energy expenditure (EE) from heart rate (HR) is 1) only appropriate for certain activities and 2) only accurate after a lengthy and complicated calibration processes has been performed for each subject. This means that it is inappropriate to use HR to estimate EE in free living situations (those outside of controlled settings and activities) and for unseen subjects. The Basis of Heart Rate and Energy Expenditure The basis for calculating EE from heart rate measurements can be summed up in a single sentence: for moderate to strenuous activity a person's heart rate increases linearly with oxygen consumption (Freedson & Miller, 2000). Crouter (et al, 2004) summed it up as: "HR is linearly related to oxygen uptake for dynamic activities involving large muscle groups". 1

These simple statements relating heart rate to energy expenditure hide a great deal of complexity, which is discussed point by point below. The frequent use of HR to estimate EE is somewhat due to the ease of use and acquisition of the HR and is based on an assumption that there is a linear relation between HR and Oxygen Consumption (VO2) which is either known for a specific individual or generalisable over large groups of people. The HR-EE relation is valid during dynamic exercise, performed with large muscular masses, however every subject has his or her own personal HR-EE equation. For HR to be a reliable parameter of an EE estimator we should therefore determine the HR-VO2 relationship of every subject in the lab through a per-subject calibration process, this is usually unpractical because of the expense in time and cost. We must also bear in mind that heart rate, during exercise or rest, can be influenced by several factors such as emotional stress, hydration level, caffeine drinks, and ambient factors (temperature, humidity, altitude). The HR is also influenced by gender, the presence of obesity, fitness level, the type of exercise, which parts of the body are exercising (such as the upper body) and if there is an isometric component or a partial isometric component. Equipped with this knowledge we can now explore the circumstances under which this linearrelationship holds true and why a "linear relationship" is not simple to employ in practice. In order to discuss the HR EE relationship we should be mindful of HR monitoring technology which is practical for this purpose. Traditional EKG electrodes are ideal for "laboratory and clinical" use but are usually limited to that environment. Professional use HR and pulse monitors can be characterised as chest strap models. Other means such as wrist monitors etc. are used in recreational situations and do not form a suitable basis for EE estimation. For example wrist units worn on the left arm require the user to touch the unit with the right hand in order to take a reading. Such units and other non-ecg HR monitors are usually unsuitable for taking continuous readings and are inaccurate during activity. A Chest Strap Heart Rate Monitor Crouter (et al, 2004) investigated the "Accuracy of Polar S410 Heart Rate Monitor" with respect to predicting EE. "The Polar S410 devise uses a nonexercise prediction equation based on user information (age, height, weight, gender, physical activity level) and resting heart rate information" to estimate HR max and VO 2max for each subject. "The participants defined their physical activity level (low, middle, high, top) based on descriptions given by the Polar S410 user s guide." Crouter's study (2004) also found the true HR max and VO 2 max by using an appropriate protocol with indirect calorimetry. Crouter found that "When the predicted values of VO 2 max and HR max are used, the Polar S410 HRM provides a rough estimate of EE during running, rowing, and cycling. Using the actual values for VO 2 max and HR max reduced the individual error scores for both genders, but in females the mean EE was still overestimated by 12%." 2

Crouter's study used data from two subjects to illustrate the linear relationships between heart rate and energy expenditure. They used these observations to deduce how their heart rate monitor may estimate EE. "We examined the relationship between estimated EE and HR, when the actual VO 2 max and HR max were programmed into the watch. Figure 1 is a representative graph for two participants (one male and one female); showing that there is a strong linear relationship (r =0.99) between HR and estimated EE, but it is unique to each participant. Therefore, we reasoned that the Polar heart watch must be taking into account the individual s HR max and VO 2 max. Figure 2 illustrates the positive, linear relationship between the percentage of HR max and the percentage of maximal energy expenditure for the same two participants in Figure 1. This time, the regression line was nearly identical for each participant, and it was similar for all participants, regardless of fitness level, gender, or other variables. Thus, it appears that the Polar S410 is using the percentage of HR max to estimate the percentage of VO 2 max,which is then converted to caloric expenditure." (Crouter et al, 2004). (Crouter et al, 2004), FIGURE 1 Representative data for two participants (one male and one female), showing the relationship between predicted energy expenditure and heart rate. Male: open circles with solid regression line (VO 2 max = 52.7 ml kg_1 min_1, HRmax _ 186 bpm, Fitness level _ top). Female: closed diamonds with dashed regression line (VO 2 max _42.8 ml kg_1 min_1, HRmax _ 198 bpm, Fitness level _ middle). 3

(Crouter et al, 2004), FIGURE 2 Representative data for two participants showing the relationship between the percent of maximal energy expenditure and the percent of maximal heart rate. Male: open circles with solid regression line (VO 2 max = 52.7 ml kg_1 min_1, HRmax _ 186 bpm, Fitness level _ top). Female: closed diamonds with dashed regression line (VO 2 max= 42.8 ml kg_1 min_1, HRmax _ 198 bpm, Fitness level _ middle). Estimating EE from Heart Rate is Only Appropriate for Certain Activities Under Controlled Conditions Keim (et al, 2004) describes "A limitation of employing heart rate as a surrogate for energy expenditure is that the relationship between HR and VO2 is weak at low activity levels, which are the levels characteristic of most sedentary individuals. For example, in a seated subject heart rate can rise or fall solely in response to emotions, caffeine intake, ambient temperature, or illness (Montoye, 1996). " Keim goes on to describe "Another important consideration before using heart rate monitors for physical activity assessment is usability. In a recent study measuring physical activity across a 2-week period, highly motivated subjects showed poor compliance in wearing a heart rate monitor for all waking hours on select days (Forrest et al, 2004)." Crouter (2004) reminds us that "The use of HR does have limitations due to influence of other factors that can affect exerciser HR. These include stress, hydration level, environmental factors such as temperature and humidity, mode of exercise (upper vs. lower body), gender, and training status." 4

Personal Calibration Required In order to accurately predict EE from HR a personal calibration needs to be made for each subject. Recall that there is a linear relationship between HR and EE under certain circumstances. However this linear relationship is different from person to person. Keim (2004) explains that a "submaximal, graded exercise test is required to calibrate the subject s heart rate to simultaneous oxygen consumption." Furthermore the subject s fitness may change over time suggesting the need to periodically re-evaluate the HR-EE relationship. Kurpad (et al, 2006) acknowledges that "the relationship between HR and energy expenditure needs to be defined in each subject, this method requires the use of indirect calorimetry, which can be difficult and expensive". Krupad's interest is in "simplifying the HR technique, such that there is no need for the use of indirect calorimetry, allowing for its use in resource-poor locations". They suggest a "simple" method which "characterized the relationship between the HR and selected activities of varying intensity for which the PAR is known" (PAR = physical activity ratio, Krupad's language for METS). "Simple" in this context means "simplifying the HR technique, such that there is no need for the use of indirect calorimetry". Calibration is still far from simple however, requiring "a calibration curve that involved the fitting of two straight lines at low and high PAR activities, respectively, to the PAR and HRR data." (Physical activity ratio = PAR; heart rate ratios = HRR, ratio of observed to resting HR). While "simple" may be simpler than using indirect calorimetry for individual calibration, this protocol shows how involved this method is: "subjects stayed overnight in the laboratory, and were assessed in the woken, fasted state. The HR monitor (Polar S720i, Finland) was attached to the subject, and they were instructed to lie quietly in bed for thirty minutes so that a steady state could be defined. The subjects then undertook five to six minutes each of a set of tasks, which included lying down at rest, sitting quietly, walking at 2.4 and 4.8 km/h on a treadmill and spot jogging at a rate of 120 steps/min, using a metronome." (Kurpad et al, 2006). Then the experimenter would construct calibration linear regressions, "Known PAR values for each task were taken from literature. except for the value of sitting. the values thus used were 1 for resting, 1.2 for sitting quietly, 2.0 for walking at 2.4 km/h, 3.3 for walking at 4.8 km/h and 8 for spot jogging at 120 steps/min." (Kurpad et al, 2006). Conclusions : HR as an individual parameter relating to EE has certain merits for specific measurements, in controlled environments and is a good index of aerobic capacity when looking at the max HR value. However the limitations of using HR alone as a predictor of EE are now clear and proven, particularly for extended periods of time, in un-controlled situations, with un-calibrated subjects, etc. The accepted calibration process involves indirect calorimetry on every subject. 5

Alternative calibration processes may be cheaper in terms of equipment cost but can be more expensive in terms of time. In general non-exercise calibration, say by means of self assessment questionnaire, can not result in an accurate calibration. Bodymedia is currently working on integrating HR into the Sensewear Armband. This is not specifically to improve the accuracy of the EE calculation which is now acceptable for clinical and research use, in free-living conditions, but because several applications are interested in looking at this parameter over time, features such as HR min, max, average, plus valuable RR variability analyses. Plus for high-end sports applications adding HR to the Bodymedia EE algorithm can further increase EE accuracy. Of prime concern is the quality of wearability (the armband's comfort, acceptance and simplicity), while acquiring ECG signals and recording for several days without replacing the electrodes. Once these concerns are resolved, the Sensewear Armband will add one more important parameter, heart rate, to the broad range of lifestyle parameters that the device can acquire. References: SE Crouter, C. Albright, and D. R. Bassett, JR. (2004). Accuracy of Polar S410 Heart Rate Monitor to Estimate Energy Cost of Exercise. Med. Sci. Sports Exercise., Vol. 36, No. 8, pp. 1433 1439, 2004. A Forrest, M Gustafson-Storms, B Gale, C Blanton, W Horn, N Keim, M Kretsch. (2004). Subject compliance using digital activity log, accelerometer and heart rate monitor to record physical activity. FASEB J. 2004;18:A112. PS Freedson, K Miller. (2000). Objective monitoring of physical activity using motion sensors and heart rate. Res Q Exerc Sport. 2000;71(suppl 2):S21-S29. Nancy L. Keim, PhD, RD; Cynthia A. Blanton, PhD, RD; Mary J. Kretsch, PhD, RD. (2004). America s Obesity Epidemic: Measuring Physical Activity to Promote an Active Lifestyle. Journal of THE AMERICAN DIETETIC ASSOCIATION. pp 1398-1409. September 2004 Volume 104 Number 9 AV Kurpad, R Raj, KN Maruthy and M Vaz. (2006). A simple method of measuring total daily energy expenditure and physical activity level from the heart rate in adult men. European Journal of Clinical Nutrition (2006) 60, 32 40 HJ Montoye. (1996). Measuring Physical Activity and Energy Expenditure. Champaign, IL: Human Kinetics; 1996. 6