Parameters exerting Influence on Cleaning of flexible Endoscops

Similar documents
The importance of cleaning for the overall results of processing endoscopes


TOTAL SOLUTION FOR ENDOSCOPE REPROCESSING

BIOTECH-GERMANDE ENDOSCOPE REPROCESSING WITH BRUSHLESS CLEANING PROCESS CONDITIONS. Lionel PINEAU PhD

A comparison of the efficacy of lumen-cleaning devices for flexible gastrointestinal endoscopes

Flexible Endoscopes: The A,B,C s of Monitoring Manual Cleaning Efficacy!

Endoscopy What s New Up There? Frank Myers, MA, CIC, FAPIC

Dissecting Outbreaks of Multi-resistant Bacteria in Gastrointestinal Endoscopy

T E S T R E P O R T. RehaWash Systems GmbH Berliner Strasse Weißwasser SN - No.: SN 12205

Monitoring Flexible Endoscope Channels to Assure Cleaning

EVOTECH endoscope cleaner and reprocessor (ECR) simulated-use and clinical-use evaluation of cleaning efficacy

Overview: High Level Disinfection

Technical Data Monograph. Reliance EPS Endoscope Processing System

Korsolex Endo-Cleaner Korsolex Endo-Disinfectant Proven and comprehensively surveyed system for the chemo-thermal reprocessing of endoscopes.

Products made in Switzerland

Endoscope Reprocessing and Infection Prevention

Case 6. Fight Against Nosocomial Infections

Validation Strategy for an Automated Endoscope Reprocessor

SUBJECT: Detection of Blood (hemoglobin) residue inside the biopsy channel of an endoendoscope

Infection Prevention in Endoscopy, Keeping Patients and Practioners Safe

Testing the Endoscope Journey vs the Decontamination Process. Wayne Spencer

Standards of Infection Prevention in Reprocessing Flexible Gastrointestinal Endoscopes Webinar FAQ

Residual bioburden in reprocessed side-view endoscopes used for endoscopic retrograde cholangiopancreatography (ERCP)

ENDOSCOPE REPROCESSING AND INFECTION CONTROL FOR ENDOSCOPY

Antiseptic and Disinfectant Product Group

VALIDATION OF WASHER-DISINFECTOR

St Boniface Research Centre Winnipeg, Manitoba Canada

The Reusable Surgical Instrument Cycle

Guidelines for Selection and Use of Disinfectants

Testing the suitability of different types of dip slides for rapid self-control of processed endoscopes

Bioindicators and Hygiene monitoring sample material. for. Cleaning and Disinfection

Slide 1. Slide 2. Slide 3

Clostridium difficile Update Dr. Michelle Alfa, Winnipeg Sponsored by ARJO

Ethicon, Inc All rights reserved. EVOTECH and the EVOTECH logo are registered trademarks owned by Advanced Sterilization Products.

In use test of a Washer-disinfector reprocessing of flexible endoscopes

pump pressure conveying quantity chamber geometry flow conditions Washing arms trays water quantity dosing temperature foam performance

Endoscopy Reprocessing: Manual versus Automated

Low Temperature Processing. An Update on Guidelines, Standards and Requirements

Professional instrument reprocessing in CSSD

Is contamination of bronchoscopes really a problem?

Disinfection & Sterilization

Cleaning, Disinfection and Sterilization. Basics of Infection Prevention 2-Day Mini-Course October 2016

SUBJECT: Detection of Blood residue inside the biopsy channel of a scope

Principles of Disinfection and Sterilization in the outpatient setting

Principles of Disinfection and Sterilization in the outpatient setting

Update on Duodenoscope Related CRE Transmission. Disclosures. Outline 9/2/2016. None

Understanding ANSI/AAMI ST 91. Flexible and Semi-Rigid Endoscope Reprocessing in Healthcare Facilities

X-Cid 2 The automatic pre-sterilization cleaning device. Your Endo Specialist

How is Sterilization Validation Performed by the Medical Device Manufacturer?

Endoscopy and OR Solutions SYSTEM 1 TM. Express STERILE PROCESSING SYSTEM SAFETY, ASSURANCE AND EFFICIENCY. One Integrated Approach to Healthcare

Guidelines for the use of disinfectants in hospital settings. Eleni Tomprou Infection Control Nurse, MSc General Hospital of Athens Polykliniki

Sterilization and Disinfection

3/26/2014 SPAULDING CLASSIFICATION OBJECTIVES PRINCIPLES OF DISINFECTION AND STERILIZATION IN THE DENTAL SETTING PROCESSING SEMI CRITICAL OBJECTS

PRINCIPLES OF DISINFECTION AND STERILIZATION IN THE DENTAL SETTING OBJECTIVES

Disinfection, Sterilization and Antisepsis: An Overview

Endoscope reprocessing: Update on controversial issues

Test Method for the Continuous Reduction of Bacterial Contamination on Copper Alloy Surfaces

Endoscope Washer Disinfector Cleaning Process Challenge Devices Research & Validation

Biofilm: Instruments & Environmental Surfaces

Testing the Effectiveness of Antiseptics and Disinfectants *

CDWA3 / CDWA4 CDWAH. Page 4. BASKET ZONE: water pressure, spray system performance, detergent chemistry and concentration, temperature.

Ideal Sterilization Method. Sterilization. Sterilization Practices in Healthcare Facilities

Validation of cleaning and sterilization of reusable medical devices

STERILIZATION VALIDATION IN THIS SECTION REPROCESSING VALIDATIONS FOR REUSABLE MEDICAL DEVICES. Radiation Sterilization Validation

Test Method for Efficacy of Copper Alloy Surfaces as a Sanitizer

TITLE: Sterilization Equipment and Requirements for Endoscopy Equipment: A Review of the Clinical Evidence and Guidelines

ENDOSCOPY PRACTICE Manual cleaning and Disinfection of flexible endoscopes

Christina Bradley Endoscope Decontamination A Webber Training Teleclass. Christina Bradley

ANNEX 2. to Guideline. for Testing, Validation and Monitoring of Automated Cleaning and Disinfection Processes for Medical Devices

Dealer Bulletin. Re: OPTIM 33TB; 3 Minute Fungicidal Claim. OPTIM 33TB Contact Times* To: All Authorized SciCan Dealers Canada

Standards of Infection Control in Reprocessing of Flexible Gastrointestinal Endoscopes

Standards of Infection Control in Reprocessing of Flexible Gastrointestinal Endoscopes

Cleaning And Disinfectant Products

MDRAO Importance of Bedside & Manual Precleaning CONMED.CA

Elevator (Scope Issues) Going Up! Frank Myers, MA, CIC Infection Prevention Clinical Epidemiology UCSD Health

3/5/2013. Agenda. Disinfectant regulations. Case History by Mary Ellen Clark Validation Scientist MedImmune

disinfectionandsterilization.org

Lumen claims of the STERRAD 100NX Sterilizer: Testing performance limits of this technology

Microfibre cleaning: is it all its been cracked up to be?

Safety, Efficacy & Microbiological Consideration

House Keeping. Introduction to ANSI/AAMI ST91:2015: Flexible and Semi-Rigid Endoscope Processing in Health Care Facilities. Welcome!

Manner of Assessment Code (check all that apply) & Surveyor Notes. Yes N/A. Yes. Yes N/A N/A. Yes N/A. N/A Yes N/A

CISA Reprocessing Systems

Duodenoscope and Endoscope Reprocessing: Are We Doing Enough to Protect Patients?

Guard by TSSU. October 4,2009

Safety, Efficacy & Microbiological Consideration

SUBJECT: Detection of residual organic soils inside various channels of lumened items.

Selection and Use of Disinfectants. Disinfection. Disinfection and Sterilization. Selection and Use of Disinfectants

HIGH-LEVEL DISINFECTANT RAPICIDE. Safety, Efficacy, and Microbiological Considerations

Irrigation accessories

Ready-To-Use Cleaning and Disinfecting Fluid for Endoscopes & Medical Instruments Technical Information

Best Practices for Reprocessing Endoscopes

High-Level Disinfectant and Sterilant. Rapicide SAFETY, EFFICACY AND MICROBIOLOGICAL CONSIDERATIONS

Monitoring the disinfection of flexible endoscopes using ATP bioluminescence

Workshop on Medical Device Cleanliness: How Clean is Clean Enough? Sponsored by ASTM Committee F04 on Medical and Surgical Materials and Devices

Kevin Lorcheim Sr. Manager

The purpose of this DOPs form is to provide a universal training and assessment tool for continuity when training in manual cleaning processes.

Virusolve + EDS. Concentrated Sporicidal High Level Disinfecting Fluid for Endoscopes & Medical Instruments Technical Information

Rapicide High-Level Disinfectant and Sterilant. Safety, Efficacy, and Microbiological Considerations

ANSI/AAMI ST91: 2015

Transcription:

Parameters exerting Influence on Cleaning of flexible Endoscops Heike Martiny Technische Hygiene Campus Benjamin Franklin Charité Universitätsmedizin Berlin ÖGSV Jahrestagung und wfhss-kongress 03. - 05. Mai 2007, Baden bei Wien

Is biofilm accumulation on endoscope tubing a contributor to the failure of cleaning and decontamination? Pajkos, Vickery, Cossart; J Hosp Infect (2004)

Reprocessing of angioscopes after contamination with duck- HBV Chaufour et al, J Vasc Surg (1999) 100 80 93 Ducks infected (%) 90 70 Cleaning: Detergent + Brush Disinfection: GDA, 2%ig Sterilisation: Ethylenoxid, 6h 60 40 20 0 0 0 6 0 6 0 5 min 10 min 20 min 6 Std Puffer Puffer + Des Reinig + Des Puffer + Ster Reinig + Ster

3 Definitionen pren ISO 15883-4 As at: 2007-04-16 3.5 Microbial inactivation factor measured change in microbial population, expressed as log 10, caused by the lethal effect of the germicide

pren ISO 15883-4 As at: 2007-04-16 Efficacy of the disinfectant log 10 6 inactivation of vegetative bacteria including yeasts and yeast-like fungi log 10 5 inactivation of mycobacteria log 10 4 inactivation of fungal spores and viruses log 10 6 reduction of bacterial spores within 5 h exposure

Max. bioburden after patient use Type cfu/ endoscope air water instrum. -channel suction Gastroscope 5.2 3.5 7.3 Coloscope 9.5 7.8 7.0 9.0 10.2 Bronchoscope 7.3 Duodenoscope 7.5 Chu et al, AJIC (1997) Vesley et al, Gastroenterology Nursing (1999) Alfa et al, Am J Infect Control 1999

3 Definitionen pren ISO 15883-4 As at: 2007-04-16 3.6 Microbial reduction factor measured change in microbial population, expressed as log 10, caused by the combination microbial inactivation factor and the physical removal of microorganisms

Alfa, Degagne, Olson Am J Infect Control 1999 Flexible endoscopes after use (log 10 cfu) Manual cleaning before after. Bronchoscopes 4.0-7.3 3.8-5.7 Duodenoscopes 0-7.5 3.7-5.3 Colonoscopes 5.7-9.5 3.2-4.6

Nelson et al Gastrointest Endosc 2003 Consensus Paper 11 societies (u. a. SHEA, APIC) Change of the enzymatic cleaner after each Endoscope

Surface fixation of dried blood by glutaraldehyde and peracetic acid Kampf, Bloß, Martiny, J Hosp Infect (2004) Type of active agent Photograph Stage of process Peracetic acid I After disinfection After cleaning Glutaraldehyde I After disinfection After cleaning QAC After disinfection After cleaning QAC + Amines After disinfection After cleaning

Surface fixation of dried blood by glutaraldehyde and peracetic acid Kampf, Bloß, Martiny, J Hosp Infect (2004) Active agent Peracetic acid Peracetic acid No. 1 2 Rate of blood removal by exposure to disinfectant 8.1% 39.0% Mean weight of blood soil on metal carriers after exposure to one of 12 disinfectants ( soiled and disinfected ); means of eight parallel experiments Peracetic acid 3 59.0% Peracetic acid 4 56.6% Glutaraldehyde 5 21.7% Glutaraldehyde 6 23.6% Glutaraldehyde 7 8.1% QAC 8 88.5% QAC 9 88.2% QAC + Amine 10 35.5% Phenole 11 90.3% Tenside 12 89.0%

DIN ISO/TS 15883-5 Test soils for flexible endoscopes AT Annex DE Annex I DE Annex J FR Annex F NL Annex L UK Annex R US Annex S Nigrosin, wheat flour, hens egg, E. faecium Blood, E. faecium Tetramethylbenzidine, hydrogenperoxide solution, bovine haemoglobin Biofilm formed by Pseudomonas aeruginosa Bovine serum albumin, procine mucin, bovin thrombin, bovin fibrinogen Glycerol, dehydrated hog mucin, horse serum, unbleached plain flour, aqueous safranine solution, water Protein/organic soil (user preference), B. atrophaeus endospores

Annex I DIN ISO/TS 15883-5 Washer-Disinfectors E. faecium 1 x 10 11 cfu/ml PTFE tubes 2 m, Ø 2 mm (transparent) Test soil Sheeps blood, 0.2 % Heparin 9.50 ml Susp. of test organism Protamin 1000 LAM 0.35 ml 0.15 ml Liquefied-(Kanamycin Äsculin Azid) -Agar-Method

Intra-laboratory reproducibility of the German test method Zühlsdorf, Floss, Martiny, J Hosp Infect (2005) 14 12 10 8 6 4 2 0 N = 12 Bacteria suspension Bakteriensuspension 12 Test soil Testanschmutzung 12 Control Kontrolle 12 Reductionrate with water Reduktionsfaktor

German test method Test pieces Test pieces cleaned Liquid-Agar-Method LAM T E C H N I S C H E H YG I E N E - H EIKE M ART INY

The importance of cleaning for the overall results of processing endoscopes Martiny et al, J Hosp Infect (2004) Log 10 Reduction (mean) ( n = 28) A: Cleaning with water B: Pre-rinsing and cleaning with water 1.1 2.0 C: Pre-rinsing, cleaning with water and interim rinsing 3.0

Efficacy of ten different cleaning processes in a WD for flexible endoscopes Zühlsdorf, Floss, Martiny, J Hosp Infect 56:305-311 (2004) 5,0 Reduktionsfaktor (lg KBE/mL) 4,0 3,0 2,0 1,0 0,0 7 5 0,0 1,0 2,0 3,0 4,0 8 Optische Sauberkeit 1 4 2 3 C, 10 B 9 A, 6

Comparison of the cleaning efficacy and the cleaning and disinfecting efficacy of four washerdisinfectors for flexible endoscopes Kircheis and Martiny, J Hosp Infect (accepted) reduction factor (lg cfu/ml) 10 8 6 4 7 Figure 1: Medians of reduction factors (lg cfu) of the cleaning processes in the AdaptaScope (Cidezyme GI and water ) and in the LS 2000 (Cidezyme GI, Liquid 52, and water ) (n = 57) 2 43 0 46 AdaptaScope Cidezyme GI n = 12 LS 2000 Cidezyme GI n= 12 LS 2000 Liquid 52 n = 12 AdaptaScope water n = 9 LS 2000 water n = 12

Cheetham, Berentsveig Australien Infection control 7 (2002) Cleaning efficay and enzyme activity of 18 cleaner P. aeruginosa - Biofilm Edinburgh soil Protease - activity Amylase - activity

Cheetham, Berentsveig Australien Infection Control 7 (2002) Cleaner 3M Rapid Auto Arbest BF Sterizime Endofresh S Endokleen Endozyme AW plus Manufact. 3M Arbos Maruishi Olympus Kendall Ruhof Enzyme activity fresh 0.38 0.21 0.20 0.35 0.10 0.00 Protease old 14 d, 40 C 0.38 0.19 0.19 0.16 0.07 0.00 fresh 13,625 131 825 193 2,843 14 Amylase old 14 d, 40 C 13,145 0 0 0 2,725 0

The importance of cleaning for the overall results of processing endoscopes Martiny et al, J Hosp Infect (2004) Cleaning only Cleaner A Cleaner B Disinfecting only Disinfectant A Disinfectant B Cleaning and Disinfecting Cleaner A + Disinfectant A Cleaner B + Disinfectant B Log 10 Reduction (mean) (n = 36) > 5.0 > 5.8 > 8.7 > 9.6 > 8.7 > 4.8 - < 5.8

Summary Inportant parameter affecting cleaning Level of burden Cleaning Efficacy of cleaning Manually Automatically Efficacy of the cleaner

What we still need Cleaning assurance level Disinfection assurance level respec. Process assurance level