Similar documents
ScreenMaster Paperless data recorders

ScreenMaster RVG200 Paperless recorder

Paperless recorders and 21 CFR part 11 compliance Videographic recorders

Key words: Computerized systems, Guidelines, Risk- based approach, Validation, Patient safety, Product quality.

Could Poor Temperature Data Management be Putting Your GxP Facility at Risk for Data Integrity Violations? we prove it.

New Data Integrity Regulations and Practical Advice for Life Science Laboratories. we prove it.

ScreenMaster RVG200 Paperless recorder

Recording. Innovative solutions for the highest requirements

ISPE NORDIC COP CLEAN UTILITIES SEPTEMBER TUUSULA FINLAND. Timo Kuosmanen STERIS Finn-Aqua

Standard Monitoring System

CUSTOMER AND SUPPLIER ROLES AND RESPONSIBILITIES FOR 21 CFR 11 COMPLIANCE ASSESSMENT. 21 CFR Part 11 FAQ. (Frequently Asked Questions)

Implement Effective Computer System Validation. Noelia Ortiz, MME, CSSGB, CQA

Jean Guichard. Introduction to Good Process Record Management (GxP) #: Internet-WP Version: e1.00 /EN

Managing Validation. Paperless Recorders

COMPUTERIZED SYSTEM VALIDATION (CSV) IMPLEMENTATION, DEMARCATION AND STRUCTURATION

ph dosing in effluent discharge (deadtime compensation) control

GAMP 4/5 Prospective / retrospective Qualification of water treatment plants) P. Dony

Regulatory Overview Annex 11 and Part 11. Sion Wyn Conformity +[44] (0)

Ensure Data Integrity Compliance Enterprise-Wide

Regulatory Expectations, Standards & Guidelines

ABB MEASUREMENT & ANALYTICS DATA SHEET. WinCCU System software products

Water Production for Pharmaceutical Manufacturing: Looking Beyond Compliance at the Entire Manufacturing Process

SIMATIC IT. SIMATIC IT R&D SUITE V7.1 Compliance Response ERES. Introduction 1. The Requirements in Short 2

References Concept. Principle. EU Annex 11 US FDA , (g), (i), 11 Orlando Lopez 2/15/11. Old Annex 11.

SOFTWARE. Software versions

Risk-based Approach to Part 11 and GxP Compliance

A BB ME ASU R E ME NT & AN AL Y T ICS D AT A S H E ET. SensyTemp TSHY (HY R-4E) Resistance thermometer for the food and beverage industries

Latino America Consultores Innovation & Technology to make your Business Compliant

OVIVO PHARMACEUTICAL SOLUTIONS SOLUTIONS FOR PURIFIED WATER, HIGHLY PURIFIED WATER AND WATER FOR INJECTION.

21CFR11 Compliance and Automated Manufacturing

Steam balancing with the flowmeters VortexMaster and SwirlMaster

EU Annex 11 US FDA 211, 820, 11; other guidelines Orlando López 11-MAY-2011

The Leading Solution for Method Validation VALIDAT

COMPUTERIZED SYSTEM VALIDATION

Data Integrity Compliance Project

Measurement & Analytics Measurement made easy. Advanced spectroscopy software for quantitative and qualitative analysis Horizon MB FTIR

Testo Expert Knowledge. The GxP Dictionary 1st edition. Definitions relating to GxP and Quality Assurance

LabX Software. Complete Overview, Total Control Smart Laboratory Instrument Software. LabX Software. LabX balance LabX titration LabX connect

WHO SAYS COMPLIANCE NEEDS TO BE COMPLICATED?

Clarity CDS since version 7.2 supportive tools for compliance with Title 21 CFR Part 11, EudraLex Chapter 4, Annex 11 and other similar legislation

Totalflow software systems

EU Annex 11 US FDA , (g), (i), 11 Orlando López 09-APR

QUALITY AGREEMENT. The following Agreement has been concluded between

Compliance Response Electronic Records / Electronic Signatures (ERES) for SIMATIC PCS 7 V8.1

UNIFI 1.5 : Simplifying Qualification and Validation June 2012

Sievers 500 RL On-Line TOC Analyzer

Validation. An Easy to Understand Guide Validating Purified Water Systems

Computerised Systems. Alfred Hunt Inspector. Wholesale Distribution Information Day, 28 th September Date Insert on Master Slide.

PLA Product Overview. PLA 2.1 Overview

Introduction to 21 CFR 11 - Good Electronic Records Management

Intelligent Sensors. Arc Gives You the Power to Connect

Documenta tion and Records

How to support compliance with GAMP 5

How to support compliance with GAMP 5

FITOCLIMA WALK-IN STABILITY

The Role of the LMS in 21 CFR Part 11 Compliance

Risk Assessment is a vital component in

Building Management Systems (BMS)

AstraZeneca. CaseStudy. Batch solution facilitates compliance with FDA regulations at AstraZeneca s Plankstadt site THE CHALLENGE

Microbial Detection. Continuous At-Line Microbial Monitoring For Pharmaceutical Waters

Instrument technology moves into process development laboratories

GAMP5 Validation for Dynamics 365

Strategies for Risk Based Validation of Laboratory Systems

á1058ñ ANALYTICAL INSTRUMENT QUALIFICATION

Addressing the Paradigm Shift in Regulatory Inspections

Automated climate monitoring in a validated environment

FITOCLIMA WALK-IN STABILITY

GMP GUIDELINES. GMP Guides from Industry Organisations. FDA cgmp WHO GMP. cgmp Guide Drugs 21 CFR 210 GAMP. ISPE Technical Guides

Data Integrity Through the Life Cycle Balancing Quality and Innovation. Sion Wyn Conformity +44 (0)

QbD1200 TOTAL ORGANIC CARBON ANALYZER RELIABLE MEASUREMENT MADE SIMPLE.

Atlant s atwatch CAPA TM. Corrective and Preventive Action System (CAPA) Product & Services Bundle for

Beamex CMX Calibration Software and GAMP - Good Automated Manufacturing Practices

Measurement & Analytics Measurement made easy. TALYS ASP310 An affordable high precision wet bath monitoring analyzer

Computer. Systems Validation. Full Time Part Time Online.

CLEANING IN MEDICAL INDUSTRY

Purified Water Systems

It s Simple. Protect the integrity of your products and your brand during cold chain transportation.

ABB MEASUREMENT & ANALYTICS DATA SHEET. ABB Ability Verification for measurement devices

World Journal of Pharmaceutical Research SJIF Impact Factor 5.990

Computer. Systems Validation (CSV) Full Time Part Time Online.

LEVERAGING YOUR VENDORS TO SUPPORT DATA INTEGRITY:

DATASHEET COMPACT CRYOGENIC-GASES TERMINAL AUTOMATION SYSTEM SYSTEM DESCRIPTION SYSTEM ACHITECTURE

COMPUTERISED SYSTEMS

GAMP Guideline & Validation Documentation

EU GMP - Annex 11 Computerised systems Versione corrente Nuova versione per commenti (emessa 8 aprile 2008)

General European OMCL Network (GEON) QUALITY MANAGEMENT DOCUMENT

Process ERP, an ideal software solution for Life Science industries

Thermo Scientific HyClone WFI Quality Water. Ultra pure to meet today s rapid manufacturing advances

According to USP <1058>

Pharmaceutical Reference Standards: Overview and Role in Global Harmonization

White paper: Code of GMP Chapter 4 Documentation - PIC/S versus EU

Data Logger Systems. Medical CSSD Pharmaceutical Food

STERIS FINN-AQUA Pure Steam Generator for Pharmaceutical Manufacturing

[ WHITE PAPER ] A Basic Overview: Meeting the PIC/S Requirements for a Computerized System INTRODUCTION GOOD MANUFACTURING PRACTICES

Impacto de las Nuevas Tendencias Regulatorias en la Producción de Parenterales. Innovacion en Packaging Primario

Welcome. Data Integrity Beyond Bytes and Signatures. Paul Daniel Senior Regulatory Compliance Expert

Infor EAM for Life Sciences

Vaisala viewlinc Monitoring System Services

Develop a Roadmap for the Implementation of a Global CSV Program. Eileen Cortes April 26, 2017

Helping Make Safe & Reliable Products Because people count on your products everyday

Transcription:

ABB MEASUREMENT & ANALYTICS APPLICATION DESCRIPTION Water purification in the pharmaceutical industry Providing independent verification and validation of the water purification process for compliance with the latest regulations and GAMP guidelines Measurement made easy GAMP compliance from ABB s paperless chart recorder range Introduction The conditions for water purification in the pharmaceutical industry are subject to stringent standards. Satisfying these requirements is essential for companies wishing to prove that their products have been safely produced and are suitable for sale both at home and overseas. When it comes to the use of electronic equipment in water purification, the de facto standards are set by the International Society of Pharmaceutical Engineers (ISPE) Good Automated Manufacturing Practice (GAMP) guidelines. Adopted by countries worldwide, these guidelines set down the main requirements that need to be considered when planning and implementing computerised system in pharmaceutical applications. Figure 1 on the next page shows the standard drivers associated with the current GAMP guidelines. As the world s largest market for pharmaceutical products, the US has led the way in developing its own interpretation of these guidelines, with the Food & Drug Administration s (FDA s) good practice rules setting the standard for companies worldwide. Particularly important are the FDA s Predicate Rules, which set stringent requirements for the manufacture, processing, packing and storage of pharmaceutical products.

2 WATER PURIFICATION IN THE PHARMACEUTICAL INDUSTRY AD/RandC/007-EN Rev. A The rules The specific predicate rules relating to pharmaceutical manufacturing are: 21 CFR Part 210, stipulating current good manufacturing practice in the manufacture, processing, packing and storage of pharmaceutical products; and 21 CFR Part 211, setting current good manufacturing practice for finished products These rules include guidance on which aspects of pharmaceutical production need to be recorded, including any process control settings, details on checking of recorded data and specific requirements relating to the collection of batch production and control records. Where these records are collected electronically, then 21 CFR Part 11 also applies, which aims to give electronic records and signatures the same weight and trustworthiness as their paper-based counterparts. A key aspect of 21 CFR Part 11 is its focus on security, particularly relating to the prevention of data tampering and the ability to identify specific individuals and events involved in the production and / or data management processes. The application Water is a major commodity used by the pharmaceutical industry. Different grades of water quality are required according to the pharmaceutical process. The United States Pharmacopoeia (USP) and the European Pharmacopoeia (EP) are the governing bodies that issue guidelines for the manufacture of drugs to their respective markets. Amongst these guidelines are regulations, legally enforceable by the FDA and European equivalents (such as the MHRA), for the purification of different grades of water used in the pharmaceutical processes: Purified water is used in preparation of medicinal products other than those that require the use of water to be sterile. Highly purified water intended for use in the preparation of products where water of high biological quality is needed, except where water for injection is required. Water for injection the purest grade of bulk water monographed by the USP and EP and is found in the manufacture of parenteral, ophthalmic and inhalation products. Focus on patient safety, product quality and data integrity Scaleable approach GxP compliance Science based quality management of risks Lifecycle approach within QMS Effective governance to achieve and maintain GxP compliance Effective supplier relationships GAMP 5 Quality by design (QbD) Use of existing documentation and knowledge Critical quality attributes (CQA) Configurable systems and development models Improving GxP compliance efficiency Figure 1 GAMP 5 sets the main requirements for the use of computerized systems in pharmaceutical applications.

WATER PURIFICATION IN THE PHARMACEUTICAL INDUSTRY AD/RandC/007-EN Rev. A 3 The challenge The validation and qualification of water purification systems are a fundamental part of Good Automated Manufacturing Practice (GAMP) and form an integral part of the GAMP inspection. Different grades of water are produced according to USP and EP requirements, usually by: distillation reverse osmosis deionisation ultrafiltration. All of these processes must be validated and recorded according to specific standards. Each set of guidelines outline legal requirements for the chemical content of each grade of water, including a three stage conductivity test for inorganic compounds that will determine ph and total organic oxygen (TOC) levels. The FDA states that implicit in the term Purified Water is that it has some reasonable, objective level of purity. TOC testing allows for evaluating impurities in water besides those which are inorganic anions and cations. Although there are no absolute microbial standards for water (other than water intended to be sterile), GAMP regulations require that appropriate specifications be established and monitored. Action or alert limits must be based upon validation data and must be set low enough to signal significant changes from normal operating conditions. In all these instances a range of instrumentation is required to meet GAMP guidelines, including conductivity meters, ph meters, temperature sensors and recording equipment. An independent monitoring and recording system should therefore be put in place to provide sufficient and secure data to ensure these processes meet the various specific standards. Good engineering practice Product knowledge Process knowledge Regulatory requirements Requirements Specification and design Verification Acceptance and release Operation and continuous improvement Company quality requirements Risk management Design review Change management Figure 2 GAMP 5 illustrates the specification, design, and verification process.

4 WATER PURIFICATION IN THE PHARMACEUTICAL INDUSTRY AD/RandC/007-EN Rev. A Security In order for recorded data to be accepted as valid proof of compliance with the various standards relating to water purification, it is necessary to eliminate any potential for unauthorized adjustment or tampering with that data. Whereas tampering with paper charts can be easily spotted, it is less obvious where electronic data is concerned. For this reason, any electronic data recorder must incorporate a full range of security features, including: Data Access restricted to authorized individuals only Password protection to protect against unauthorized access Audit trail facility to independently attribute a time and date every time a record is created, modified or deleted The ability to protect against unwanted loss of recorded data Use of digital signatures to show that the device has only been used by authorized persons It is also necessary to ensure that recorded data cannot be altered when downloaded to a PC or other device for review. The solution As there are a number of methods for producing purified water of different grades there are also a variety of different parameters must be monitored and controlled, including conductivity, ph, temperature and pressure, amongst others. It is important to perform a regular calibration check and to be able to perform full calibration adjustment for the system inputs, as it is important to verify that the measurements made are reliable. The system that records the data should also independently trigger warning and active alarms, should the accepted process parameters be exceeded. These often incorporate a time delay and / or a hysteresis. This only triggers the alarm once the parameter has exceeded acceptable levels by a certain amount of time, which helps prevent nuisance alarms. The provision of Ethernet connectivity will also allow historical recorded data and alarm and audit trail information to be relayed automatically to a central database where archive and analysis, if required, can take place. The use of independent recorders for production of purified water allows specific, independent and easily validated processes to be monitored without the requirement of validating an entire complex Distributed Control System (DCS). It shows exactly what has happened, together with details of any alarms in real-time.

WATER PURIFICATION IN THE PHARMACEUTICAL INDUSTRY AD/RandC/007-EN Rev. A 5 What can ABB offer? ABB offers a full range of products and expertise that can help operators comply with the requirements for water purification. ABB offers GAMP validation templates with its SM series of videographic recorders, compliant with 21 CFR Part 11, that will follow the unit s life through delivery, calibration, production and can even extend to its end of life disposal. ABB can offer a range of validation documentation services in accordance with the required application, such as instrument configuration sheets to help document the User Requirement Specification (URS) and aid the production of the Functional Specification (FS), as well as Installation Qualification (IQ) and Operational Qualification (OQ) documentation. Figure 3 ABB paperless recorders and data review software

6 WATER PURIFICATION IN THE PHARMACEUTICAL INDUSTRY AD/RandC/007-EN Rev. A... What can ABB offer? SM500F The world s first field-mountable videographic data recorder, the SM500F can be part of a fully compliant 21CFR11 system - the FDA s (Food and Drug Administration) regulations concerning electronic process data collection. Process data is displayed clearly to the local operator through a variety of display formats, including chart, bargraph and digital indicator. With two totalizers per input, the SM500F allows even greater control of data. One totalizer can be left to run for the life of the recorder to give a complete history of the data measured; the other can be reset when necessary to measure certain parameters or time periods. The SM500F offers up to seven analogue inputs, enabling multiple sensors to be connected. This is accompanied by 12 recording channels that can each record process and communications inputs, math block results, digital signals and other values, providing additional detail and functionality. The SM500F can send email notifications whenever an alarm occurs to ensure that any potential problems are promptly addressed. Users can also choose to receive email status reports at any time. The SM500F now also provides users with greater functionality for batch recording processes. When a new batch is initiated on the control system, the SM500F will automatically start to record the batch, including any associated batch information. This eliminates the need for the operator to duplicate the data entry process on both the recorder and the PLC, saving time and reducing the chance of any potential errors. The SM500F comes with a choice of Ethernet or RS485 communications. Ethernet allows link-enabled historical data to be remotely downloaded to a PC for subsequent analysis via ABB s DataManager Pro software. It also enables a web browser view and connection to a SCADA or PLC system using the Modbus TCP protocol. The RS485 option gives Modbus RTU in either three- or five-wire configurations. These protocols provide the ideal opportunity for integration of third party equipment into the display and recording systems by OEMs. Figure 4 SM500F field-mount paperless chart recorder

WATER PURIFICATION IN THE PHARMACEUTICAL INDUSTRY AD/RandC/007-EN Rev. A 7 RVG200 The RVG200 recorder takes the established operating and security benefits of the ScreenMaster range one step further. Features include touchscreen swipe operation, front and rear USB ports for connecting peripheral devices (including a barcode scanner and keyboard) and Ethernet and RS485 communications. Up to 24 process signals can be connected to the RVG200 s analog inputs or transferred to it via digital communications. As with all devices in the ScreenMaster paperless recorder range, the RVG200 features extensive security measures to protect against unauthorized tampering with process data, compliant with FDA 21 CFR Part 11 requirements. Standard security features include the ability to configure and allocate multiple users with individual password and access rights. All recorded data is also securely stored by the RVG200 s 256 MB of internal flash memory that can be expanded to 2 GB if required. DataManager Pro ABB s DataManager Pro analysis software offers a powerful tool for reviewing recorded data. Using the software, operators can review data from multiple recorders. Functions include the ability to compile graphical charts comparing multiple parameters, plus a dual cursor function enabling operators to review data for specific periods of time and specific recorders. ABB s ScreenMaster series paperless recorders feature Ethernet communications, allowing users to access the recorders from any web browser. Information can be automatically retrieved and placed in DataManager Pro for further analysis. DataManager Pro also offers a range of presentation possibilities, including the ability to annotate specific alarms and present recorded data as a combined graph accompanied by tables and statistics. Figure 5 RVG200 paperless recorder Figure 6 DataManager Pro data review software

ABB Limited Measurement & Analytics Howard Road, St. Neots Cambridgeshire, PE19 8EU UK Tel: +44 (0)1480 475 321 Fax: +44 (0)1480 217 948 Mail: instrumentation@gb.abb.com ABB Inc. Measurement & Analytics 125 E. County Line Road Warminster, PA 18974 USA Tel: +1 215 674 6000 Fax: +1 215 674 7183 abb.com/measurement We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB. ABB 2017 All rights reserved. AD/RandC/007-EN Rev. A 11.2017