MEMO. Kris Hinskey

Similar documents
Best management practices for vapor investigation and building mitigation decisions

An RT Regulatory Program Summary

Vapor Intrusion in Massachusetts Gerard Martin

March 2010 Frequently Asked Questions

Evaluation of VI Data Relative to Separation Distance Screening Criteria A Michigan Case Study

i-admin /15/14 2 of 3 Doc Type: Board Memo/Issue Statement

Armen Cleaners Indoor Air Quality Investigation. Jon Gulch, OSC U.S. EPA, Region V, ERB

This Fourth Quarter 2013 Progress Report (No. 10) covers the period of October 1, 2013 through December 31, 2013.

Calculation of Site Specific Groundwater to Indoor Air Volatilization Factors (GIVFs)

Indoor Air Study Data Summary and Analysis Report Main TCE Plume, OU5 Former Lowry Air Force Base Denver, Colorado

Soil Vapor Migration Through Subsurface Utilities

BACKGROUND OFFSITE FACILITIES/RELEASE CASES

Steps in Conducting Structural Vapor Intrusion Potential Evaluations Under the Inactive Hazardous Sites Branch 13 February 2017

Vapor Intrusion - Site Characterization and Screening. NEWMOA Workshop on Vapor Intrusion Chelmsford, MA April 12, 2006

A Rational Approach to Vapor Intrusion Preferential Pathways

Is this the maturation Phase of Vapor Intrusion Investigations?

Proposed MCP Amendments

PA Vapor Intrusion Guidance

REGULATORY-DIRECTED COMBINED REMEDY APPROACH FOR CHLORINATED VAPOR INTRUSION/MITIGATION AND GROUNDWATER REMEDIATION UNDER A RESIDENTIAL NEIGHBORHOOD

SAMPLING AND ANALYSIS PLAN FOR TIER 3 AIR QUALITY MONITORING 218-1/2 South Findlay Street, Seattle (Location 10)

New Data on Attenuation Coefficients for Crawl Spaces and Deep Soil Gas from the Lowry AFB Site, Denver, Colorado

November 8, 2016 International Petroleum Environmental Conference. Tim Nickels Pastor, Behling & Wheeler, LLC

February 25, Mr. Wayne Loflin, Maintenance Director Winston-Salem/Forsyth County Schools PO Box 2513 Winston-Salem, NC

IPEC Conference San Antonio, TX November 13, 2013 Glenn Nicholas Iosue

Implementation of a Strategic Approach for Complex Vapor Intrusion Assessment at a Large Military Facility

TRANSPORT PATHWAY EVIDENCE OF A SEWER VAPOR. Findings from Work Performed at the Indianapolis USEPA Research Duplex

QUARTERLY TECHNICAL PROGRESS REPORT JANUARY 2012 MARCH 2012 RCRA CORRECTIVE ACTION IND

NJDEP Vapor Intrusion Guidance

Oregon Guidance for Assessing and Remediating Vapor Intrusion in Buildings

Area B Groundwater Investigation Fort Detrick

Fort George G. Meade. Restoration Advisory Board Meeting March 25, 2010

Vapor Intrusion Update: Separating the Environmental exposure from Indoor Air Quality Issues Guidance

Transmitted via . Mr. Nate Nemani U.S. Environmental Protection Agency Region 5 77 West Jackson Boulevard LU-9J Chicago, IL

PM STRAUSS & ASSOCIATES Energy and Environmental Consulting MEMORANDUM

MDEQ PROJECT UPDATE (2015 4Q PROGRESS REPORT)

Hoovering the Hoover District, North Canton, Ohio by Lenny Siegel May, 2017

A REVIEW OF VAPOR INTRUSION GUIDANCE BY STATE

Date: 05/25/2006. Bob Hare/ENCORE. From: Tony Perfetto/CRA. Gavin O Neill/CRA John McKenna/BBL

I would like to thank the many program stakeholders who have provided valuable input in the development of this document.

This work will be completed in support of the corrective measures evaluation. The objectives of this study are as follows:

EPA Vapor Intrusion Update

Transmitted via . Mr. Nate Nemani U.S. Environmental Protection Agency Region 5 77 West Jackson Boulevard LU-9J Chicago, IL

EPA S 2015 vapor intrusion guides What do they mean for your facility?

Conceptual Site Model for Mercury Impacted Soil and Groundwater as a Tool for Effective Remediation

Activities during Reporting Period Activities completed during January, February, and March 2009 are summarized below.

Update - Vapor Intrusion and Mitigation in Florida

Part 3 Fundamentals. Most Common VI Bloopers. Handy Unit Conversions:

SOUTHWEST DIVISION Comparing Air Measurements and Modeling Results at a Residential Site Overlying a TCE Plume October 18, 2004

Vapor Intrusion Assessment. Kaitlyn S. Rhonehouse, P.E. Florida Brownfield Association 16 th Annual Conference, Brownfields in Motion

Quantitative Decision Framework for Vapor Intrusion Evaluation in DoD Industrial Buildings - Based on an Empirical Database

The total estimated project costs and funding sources are summarized in the table below. Description Total Project Expenditures 20

Transmitted via . Mr. Nate Nemani U.S. Environmental Protection Agency Region 5 77 West Jackson Boulevard LU-9J Chicago, IL

Former NCBC Davisville Site 16 Former Creosote Dip Tank and Fire Training Area

Remedial Methods for Mitigating Vapour Intrusion to High Density Urban Developments

U.S. ARMY CORPS OF ENGINEERS FINAL INDOOR AIR QUALITY REPORT #8 FORMER RARITAN ARSENAL EDISON, NEW JERSEY

July 13, Via Original to Follow by Mail

LSPA Comments: MassDEP 2014 Public Review Draft, Vapor Intrusion Guidance

May 5, Mr. Mostafa Mehran Arkansas Department of Environmental Quality 5301 Northshore Drive North Little Rock, Arkansas 72118

Interim Source Removal Summary Groundwater Extraction System Former American Beryllium Company Site Tallevast, Florida

Vapor Intrusion Pathway Feasibility Study

New Insights Into Exposure Through Preferential Pathway Vapor Migration

Mass Flux Characterization for Vapor Intrusion Assessment

Multi-Component Remediation of Petroleum and Metals at a Former Power Plant in San Francisco, California

Five Vapor Intrusion Sites in New York State Lenny Siegel August, 2007


DoD Environmental Monitoring & Data Quality Workshop

2012 Additional Block E Soil Investigation Report Lockheed Martin Middle River Complex 2323 Eastern Boulevard Middle River, Maryland

New York State Department of Environmental Conservation & Department of Health Representatives. Unisys Corporation

Indoor Air Quality Testing at the Middle River Complex. Indoor Air Quality Testing at the Middle River Complex. For More Information

Site Specific Remediation Objectives for Soil Vapour in Alberta (Draft) Norman Sawatsky

A Review of Preferential Pathway Case Studies: Lessons-Learned for Vapor Intrusion Site Assessment

the former Honeywell plant building (3 Hamilton Avenue) a single-storey brick industrial/commercial building (233 Armstrong Street)

Detailed discussion of the Petroleum Vapor Database is provided in Davis R.V., 2009, LUSTLine #61 and EPA Jan

Vapor Intrusion Mitigation: Answering the Common Questions Plaguing Brownfield Developers West Virginia Brownfields Conference

Southern Cleaners & Laundry Jacksonville, North Carolina. CASE STUDY Vapor Intrusion Pathway: Evaluation and Risk Assessment

Site Investigation of Ground Water

23 February 2017 Reference No L-Rev1-8500

Excavation of petroleum-contaminated soil and tank removal sampling Petroleum Remediation Program

The IAQ/Mold Assessment Getting it Right! Controlling Your Risk

Copies: Dave Favero, RACER

INDOOR AIR INVESTIGATION

City Policy & Procedure

Closed Castner Firing Range Remedial Investigation. Technical Project Planning (TPP) Meeting #4 07 November :00 AM 11:00 AM

FACTS ABOUT: Former GE Power Systems Apparatus Service Center (Voluntary Cleanup Program) Site Location

MISSOURI RISK-BASED CORRECTIVE ACTION (MRBCA) FOR PETROLEUM STORAGE TANKS SOIL GAS SAMPLING PROTOCOL

Background. NCP Early or Interim Actions 5/3/2017. Current Ohio EPA Response Action Levels and Time Frames for TCE at Vapor Intrusion Sites in Ohio

Remedial Program Status Updates GE Plant Sites in Hudson Falls and Fort Edward. Hudson River Community Advisory Group June 27, 2013

FACTS ABOUT: Vapor Intrusion

In Situ Thermal NAPL Remediation at the Northeast Site Pinellas Environmental Restoration Project

U.S. EPA s Vapor Intrusion Database: Preliminary Evaluation of Attenuation Factors

Navy VI Web Tool: A Systematic Approach for Assessing Strength of Evidence

Practical Aspects of VI Assessment for TCE. Acknowledgments and special thanks to:

RISK BULLETIN. Vapor Intrusion An Emerging Environmental Liability WHAT IS VAPOR INTRUSION?

Health Consultation. South Indian Bend Wash Landfill Area TEMPE, MARICOPA COUNTY, ARIZONA. CERCLIS No. AZD

Eric M. Nichols, PE Amy Goldberg Day

Risk-Based Clean-Up in Georgia Under the VRP Vapor Intrusion

Examples of Data Collection Strategies and Methods

Conceptual Site Model Considerations - Terrestrial/Groundwater

Expediting Vapor Intrusion Assessments Using High Resolution Continuous Monitoring

Vapor Intrusion: A State s Perspective

Transcription:

To: Paul Owens, District Supervisor MDEQ SE Michigan District Office 27700 Donald Court Warren, Michigan 48092-2793 owensp@michigan.gov Copies: Brandon Alger MDEQ Gerald Tiernan - MDEQ Todd Walton Ford Motor Company Chuck Pinter Ford Motor Company Rob Ellis - Arcadis Joe Quinnan - Arcadis Arcadis of Michigan, LLC 28550 Cabot Drive Suite 500 Novi Michigan 48377 Tel 248 994 2240 Fax 248 994 2241 From: Kris Hinskey Date: December 12, 2017 Arcadis Project No.: MI001322.0001 Subject: Livonia Transmission Plant Response to Michigan Department of Environmental Quality Comments Consent Decree Reporting - Conceptual Site Model 36200 Plymouth Road, Livonia, Wayne County, Michigan MDEQ Site ID No. 82002970 On behalf of Ford Motor Company (Ford), this response to comments has been prepared by Arcadis of Michigan LLC for the Livonia Transmission Plant (LTP) site (the site). The Michigan Department of Environmental Quality (MDEQ) approved the initial LTP conceptual site model (CSM) report on November 13, 2017. As part of the approval, the MDEQ included several comments outlining expectations for future response activities. This memo provides a brief summary of the MDEQ comments followed by Ford s response to comment. A more detailed response will be provided in the Response Activities Plan (RespAP) for Remedial Investigation (RI). Comment #1: Continue with investigation of groundwater impacts including the extent of groundwater plume beneath the primary plant structure, potential vapor impacts to the eastern plant structure, out -buildings shown to be potentially impacted by groundwater sampling, off-site boundaries where groundwater in perimeter wells is above screening levels, and other Area of Concern (AOC) locations where data is shown to have not delineated groundwater to concentrations outlined in the Consent Decree (CD). G:\COMMON\Ford\Livonia\04 Draft Reports\17-08-21 CSM\MDEQ Approval and Response\2017_12_12_LTP_CSM Response to MDEQ Comments Memo.docx 1/5

Acknowledged. Additional groundwater delineation activities are outlined as part of the forthcoming RespAP. Most of the groundwater impacts that migrated to the east have been well characterized and delineated. The exceptions are areas to the northeast of the LTP wastewater pretreatment facility, where trichloroethene (TCE) has not been delineated to the north of the site boundary, off site at the northeast corner of the property boundary, where low levels of vinyl chloride (VC) have not been delineated, and in two additional areas of VC impacts east of the site and north of Rosati Drive. Comment #2: All future sampling must use appropriate methods for Method Detection Limits (MDL) at or below provided screening levels, unless Ford is to provide, and MDEQ to approve, an alternative site-specific screening level at which point this would be the new MDL. Acknowledged. Note that a separate RespAP requesting a Target Detection Limit (TDL) change for TCE and VC in residential groundwater was submitted to MDEQ on November 21, 2017. Upon approval from the MDEQ, the new TDL for TCE and VC would be 1.0 microgram per liter (µg/l), which is consistent with the published 2016 MDEQ Remediation and Redevelopment Division TDL. Comment #3: Investigate and document potential utility corridors which may have become preferential pathways. Provide insight to how these corridors have been, or will be, investigated. Pay special attention to sediment outfall, migration along preferential pathways created by the sewer line, and other impacts from the former cracked storm drain at the southeastern portion of the property. Acknowledged. Actions to address potential migration of impacts in utility corridors will be outlined in the RespAP. Response activities will focus on the following: Additional evaluation of the eastern storm sewer, western storm sewer, and sanitary sewer systems. Sediment samples will be collected from the on-site eastern and western diversion chambers to determine if constituents of concern (COCs) are present. Current monitoring wells will also be evaluated to determine if the well screens are constructed at similar depths as the adjacent sewers. Comment #4: Conclusions made about on-site VI do use multiple lines of evidence, but the MDEQ does not agree that the lines of evidence are sufficient in making the determination, made by Ford, that "VI is likely not occurring." Indoor air sampling is highly variable and even sampling "multiple times" only provides multiple isolated snapshots. A lack of a pressure gradient does not indicate VI is not occurring. To use pressure as a line of evidence, the gradient would need to be negative beneath the slab, assuring airflow from the pressurized building, to the depressurized sub- slab area. The Johnson & Ettinger Model does not allow for a slab to be used as a reliable remedial activity, more information about the epoxy coating and any QA done for this would be required. An epoxy coating not designed or tested for vapor mitigation should not be assumed to be of any use. 2/5

Acknowledged. As indicated in the CSM and in MDEQ Comment 5, a sub-slab depressurization system is currently being installed inside the LTP to pre-emptively mitigate locations identified in the CSM that warranted an interim mitigation response. Comment #5: Proceed with design and implementation of on-site sub-slab depressurization system for on-site remedial activities; begin investigation for appropriate off-site remedial activities where it can be shown that a completed pathway may exist. Acknowledged. The proposed work will focus on the on-site and off-site actions indicated below. On-site: As indicated in the CSM, a sub-slab depressurization system is currently being installed inside the LTP. Off-Site: As requested, additional work will be completed off site to further evaluate the potential for vapor intrusion. Comment #6: Determine if and where the "clean water lens" is consistently reliable. From the CSM and based on discussions with Ford, it is clear that a significant part of the response is to rely upon the existence and reliability of this proposed clean water lens. This needs to be proven and well documented. Establish how top and bottom of lens is defined. Incorporate into future editions of the Conceptual Site model (CSM) how we know this is stable or unstable. What is the minimum thickness in each area it is relied upon? What is the source of this water? What is the long-term behavior of the water? Is this to be relied upon in perpetuity? Design appropriate response activities around this greater understanding of the "clean water lens". If Ford is to continue to rely upon this lens to protect residents from potential Vapor Intrusion, the MDEQ expects this lens to be defined and established as stable, reliable, and protective of any potential risk to receptors. The clean water lens is one piece of the CSM that helps explain the lack of off-site vapor impacts and is was not proposed as part of a future remedy at this time. To date, three rounds of soil vapor samples have been collected from off site soil vapor monitoring point locations. The data from these sampling events are consistent, showing a lack of volatile organic compounds (VOCs) in soil vapor. Follow-up sampling of nested monitoring wells also continues to demonstrate the presence of the clean water lens. As part of the RespAP, results from additional groundwater sampling and soil vapor sampling will document the presence or variability of the lens. Comment #7: Further investigate vapor intrusion pathway with continued soil-gas samples, including appropriate off-site, sub-slab, soil-gas samples to investigate composition and behavior of soil-gas beneath residential homes, and find where completed exposure pathways exist. Measure and report atmospheric barometric pressure on days of soil-gas or sub- slab sampling. 3/5

Off-site, sub-slab samples are going to be highly-recommended, for a determination of how soil vapor behaves beneath the structures. This won't be required for each home as appropriate selection may be extrapolated to structures better protected by the proposed clean water lens, if established, or horizontal exclusion zone (100' from screening level). The vapor intrusion pathway will be further investigated as proposed in the Detailed Vapor Intrusion Assessment and Mitigation Plan and RI. Barometric pressure has been recorded during all vapor intrusion sampling events to date and will continue to be recorded. Comment #8: Demonstrate that the off-site, near-slab, soil-gas samples are representative of soilvapor which is in contact with the groundwater, and not ambient air being pulled from above. Clearly document how this is demonstrated. To ensure no breakthrough of ambient air during sub-slab soil vapor and exterior soil vapor sampling, a number of steps have been taken. No evidence of ambient air breakthrough has been observed during these sampling events. Steps taken are presented below: LTP sub-slab soil vapor locations: Permanent vapor pins were installed. A water dam test was conducted at each location. Off-site soil vapor locations: The screened interval length was reduced to 1 inch inside a 3-inch sand pack to allow for a thicker bentonite seal above each point. Each point was allowed to equilibrate at least 24 hours before sampling. A helium tracer gas test was conducted at each sample location to verify integrity of installation; no helium was noted in purged air. Samples with a low flow rate (i.e., 1-liter canisters collected over a 20-minute period) were employed to provide minimal vacuum influence on the formation. Comment #9: Summarize necessary source information to better define which sources are most problematic and estimate, to the best of your knowledge, the amount of product released at these problematic sources. If possible, include a date or range of dates when this product was released. The volumes and timings of specific VOC releases are unknown. The light non-aqueous phase liquid (LNAPL) time of release is unknown, but likely occurred gradually over a period of time. The volume of LNAPL can be estimated using the 3D model. The forthcoming RespAP includes additional source area evaluation, including both a desktop component to identify potential sources and an initial phase of borings to better characterize potential sources outlined as part of the CSM (i.e., PS-1 through PS-6). 4/5

The spatial distribution of VOCs in groundwater, combined with relative flux analysis, indicated that PS-1 is the most significant source of VOC impacts to groundwater. Other sources (PS-2 through P-5) show orders of magnitude less impact and flux, and have been primarily identified via soil gas screening. Comment #10: Include areal and cross-sectional delineation of DNAPL in future CSM. Acknowledged. Additional data collected from source areas will be presented on cross-sections as appropriate to best represent the CSM. Comment #11: Proceed with using the working CSM and associated updates to conduct and prepare Response Activity Plan which includes a diagram or flow chart for each potentially impacted off-site structure (within lateral inclusion zone), based on its construction and any associated contamination. Include discussion on which cases would result in which response activity if all completed pathways cannot be ruled out. Each off-site property has been evaluated and presented in tabular format within the CSM (Table 13 and Figure 44). Multiple lines of evidence will be considered for each property and discussed with MDEQ. A more detailed scope will be developed once home inspections are completed and additional information from the homes has been evaluated. 5/5