Integrating Risk-Based Inspection Recommendations with Inspection Programs and Integrity Operating Windows

Similar documents
Using Risk-Based Approaches to Define and Adjust Condition Monitoring Locations, Inspection Techniques and Intervals

REAL-TIME PREDICTIVE ANALYTICS AND CORROSION MONITORING WITH PREDICT -RT

Sridhar Srinivasan June 20, 2017 REAL TIME PREDICTIVE ANALYTICS AND CORROSION MANAGEMENT WITH PREDICT -RT

Applications of Aqueous Process Modeling to Petroleum Refinery Corrosion Control

Corrosion Potential - Refinery Overhead Systems

Corrosion Monitoring Solutions for Hydroprocessing Units

Memoranda On Front-end Crude Fractionation.

GT-LPG Max SM. Maximizing LPG Recovery from Fuel Gas Using a Dividing Wall Column. Engineered to Innovate

TABLE OF CONTENT

GTC TECHNOLOGY. GT-UWC SM How a Uniting Wall Column Maximizes LPG Recovery. Engineered to Innovate WHITE PAPER

Corrosion Management Methods of High TAN Crude. Case study: (Fula Crude Oil-Sudan)

Overview. Challenges in Opportunity Crude Processing 16 th April 2012

Geothermal Operations and Material Science

September 2010 API Recommended Practice

AMERICAN PETROLEUM INSTITUTE API RP 581 RISK BASED INSPECTION METHODOLOGY BALLOT COVER PAGE. Title: MODIFICATION OF API 581 CARBONATE CRACKING

Crude Tower Simulation HYSYS v10

Module 2: Solid Fossil Fuel (Coal) Lecture 12: Combustion of coal and coke making

MODIFICATION OF API 581 CARBONATE CRACKING Confirmation Ballot

Gas Dehydration Field Manual

Best Practice Corrosion/Erosion Monitoring and Critical Process Indicators Salton Sea KGRA. by Dr. Dan Hoyer, PE Veizades & Associates, Inc.

In 1965, while working as a

Determination of Corrosion rates and remaining life of piping using API and ASME standards in oil and gas industries

Guidelines for Dynamic Modeling of Column Startup Chemstations, Inc.

API 571 CORROSION & MATERIALS PROFESSIONAL CERTIFICATION PREPARATION PROGRAM

API 571 CORROSION & MATERIALS PROFESSIONAL CERTIFICATION PREPARATION PROGRAM

Salt deposition in FCC gas concentration

Atmospheric distillation of crude oil

Mitigate Your Corrosion Risks Predictive Corrosion Management

API 571 Damage Mechanisms Affecting. Fixed Equipment in the Refining Industry WHO SHOULD ATTEND TRAINING METHODOLOGY

AFPM 2018 Operations & Process Technology Summit

Fate of Ammonia in Refinery Amine Systems

Downsizing a Claus Sulfur Recovery Unit

EFFECTS OF FLOW VELOCITY ON RBI ANALYSIS OF COOLING WATER HEAT EXCHANGERS

Stephen M. Patera, Sales Manager, LHI Metals. October 6-9, 2013 Caesars Palace, Las Vegas, Nevada, USA

Detection of In-service Wet H 2 S Cracking at Reboiler Shell Weldment using Phased Array Ultrasonic Testing (PAUT)

Maintaining a Real-Time RBMI Program. Dan Mahoney Reliability Engineer HollyFrontier Corporation El Dorado, KS

ENGINEERING STANDARD FOR PROCESS DESIGN OF CRUDE OIL ELECTROSTATIC DESALTERS ORIGINAL EDITION JULY 1995

Applying Dynamic Process Simulations Toward Flaring Reduction

HYSYS WORKBOOK By: Eng. Ahmed Deyab Fares.

WWT Two-Stage Sour Water Stripping

A New Optimisation Based Retrofit Approach for Revamping an Egyptian Crude Oil Distillation Unit

Delayed Coking Process Design, Operations and Optimization. Canada Coking Conference October 22-26, 2012 Fort McMurray, Alberta

Corrosion in GASCO Habshan CBA Units and its mitigation

Predict 7.1 Product Information Note

Problems at the Cumene Production Facility, Unit 800

Water Conservation Initiatives Burnaby Refinery

A Case Study in Refinery Energy Improvement

DIESEL HYDRODESULPHURISATION UNIT CHAPTER-9 CATALYST AND REGENERATION

SUEZ helps refineries to save time, reduce energy consumption, emissions and waste by efficient decontamination

Sulfur Area Materials of Construction

SECTION 3.0 DEFINITION OF TERMS AND ABBREVIATIONS

Modular Oil & Gas Equipment Onshore & Offshore

White Paper. Impact of Opportunity Crudes on Fouling in Preheat, distillation, and furnace systems

heat transfer fluid propylène glycol Inhibé Fluide de transfert de chaleur available in : Do not mix with ethylene glycol heat transfer fluids.

Difficult CEMS Applications at Refineries & Chemical Plants

Coker Safety and Reliability Lessons Learned

Combatting HCl Acid-Dewpoint Corrosion at The Geysers. John Farison Calpine Corporation

Corrosion monitoring solution for sour water stripping units

About the Correlation Between Crude Oil Corrosiveness and Results From Corrosion Monitoring in an Oil Refinery

Performance Review of CASTOR Pilot Plant at Esbjerg

CML OPTIMIZATION: EFFECTIVE AND EFFICIENT COVERAGE AND PLACEMENT

SURFACE PRODUCTION OPERATIONS

Lowering Column Tops Temperature to Improve Product Yields, While Avoiding Penalty due to Salting & Corrosion

Distillation DEPARTMENT OF CHEMICAL ENGINEERING

USING OLI TO DESIGN SOLUTION TO MINIMIZE THE CORROSION OF CRUDE DISTILLATION TOWERS

Corrosion and Materials Selection for Bitumen with Heavy Naphthenic Acid in Canadian Oil Sands

ADVANCED PROCESS CONTROL

Top of Line Corrosion and Water Condensation Rates in Wet Gas Pipelines

New Developments in Measuring Low Silicon in Process Piping Using Handheld X-ray Fluorescence (XRF)

Reduction of Sulphur in Superior Kerosene

Distillation Experiment--Flooding

Reducing FCC Turnaround Costs Focus on Speed & Safety. Brent Dell Sr. Technical Engineer

Reducing FCC Turnaround Costs Focus on Speed & Safety. Brent Dell Sr. Technical Engineer

Welcome to. FORCE Technology

TROUBLE SHOOTING IN DELAYED COKER UNIT- INSPECTION EXPERIENCE

Water Management in Process Plants. David A. Puckett University of Oklahoma Department of Chemical, Biological, and Materials Engineering 5/2/2008

Zoltán Miczki 26 September 2017 REAL TIME PREDICTIVE ANALYTICS AND CORROSION MANAGEMENT WITH PREDICT -RT

Simple Dew Point Control HYSYS v8.6

Sulfur Unit Equipment Problems and Low Silicon Carbon Steel Corrosion Gerald W. Wilks Lemont Refinery CITGO Petroleum

Fluor s Econamine FG Plus SM Technology

Failures of High Alloy Expansion Bellows in Refinery Catalytic Cracking Units

Benefits of Risk Based Inspection to the Oil & Gas Industry Paper to be presented at the Oil & Gas Conference, Perth, Australia April 2000

SHELL RISK-BASED INSPECTION (S-RBI) Basics & Related Approach to Corrosion under Insulation (CUI)

An Exergy Analysis on a Crude Oil Atmospheric Distillation Column

Minimize the Risk of Fire During Distillation Column Maintenance

James E. Parker \ Sr. Director of Business Development - Amerapex. CUI Technical Workshop NACE - Jubail Dec 10th 2015

Example SPC-2: Effect of Increasing Column P on a C3 splitter

J. Christopher Lewis Distillation Column Flooding Predictor INTRODUCTION

Taravosh Jam Design & Engineering Co.

Monitoring Asset Integrity Using Installed Ultrasonic Sensors

15-19 January, February, 2017

NEW RECYCLE PROCESS SCHEME FOR HIGH ETHANE RECOVERY NEW PROCESS SCHEME FOR HIGH NGL RECOVERY INTRODUCTION. Abstract PROCESS FUNDAMENTALS

Heavy Oil Controlled Document Corrosion Management Framework Project Document Title Document Number Document Revision Document Status Document Type

SmartCET Corrosion Monitoring On-line, Real time Product Information Note

AMINE SYSTEM FAILURES IN SOUR SERVICE

UOP Selexol TM Technology Applications for CO 2 Capture

CORROSION AND FOULING IN SULFURIC ACID ALKYLATION UNITS

Does Your Application Call for an F-Shell Heat Exchanger?

STYRENE BUTADIENE PLANT PROCESS DESCRIPTION TO BE READ WITH REFERENCE TO DRAWING SBR and SBR

Non-Intrusive Corrosion and Erosion Monitoring Solutions and Case Studies. Dr. Jake Davies, ICorr Aberdeen meeting, 28th Feb 2017

Transcription:

Integrating Risk-Based Inspection Recommendations with Inspection Programs and Integrity Operating Windows Lynne Kaley, PE Principal Trinity Bridge, LLC Savannah, GA W. Clay White Fixed Equipment Network Lead Phillips 66 Houston, TX

Introduction Risk-Based Inspection (RBI) has been widely used to optimize inspection activities in the industry starting in the 1990 s RBI for pressure vessels has been generally accepted and easily managed Application to piping corrosion loops/systems in a manageable way has been more challenging Establishing Integrity Operating Windows (IOW s) using API 584 is an opportunity to manage fixed equipment and piping and integrate inspection activities with RBI Need to outline the steps for defining a piping inspection program using risk with corrosion loop & circuit definition and identification of IOW s Discuss challenges to inspection planning using risk for piping corrosion loops

Work Process Establish risk approach and basis for inspection plan development (inspection date, methods and coverage) Determine RBI unit scope, including fixed equipment and piping boundaries (typically includes primary piping and bypasses but not including utilities piping and piping after PRDs) Organize updated unit drawings and relevant data for analysis P&IDs, PFDs, not necessarily including piping isometrics Define corrosion loops and naming convention Circuitize piping within each corrosion loop Conduct material/corrosion of all equipment included in unit study Create an database for calculation of risk and development of inspection plans Calculate Risk Establish IOWs Develop Inspection Plans

Considerations for Integrating RBI, IOWs and Piping Inspection Model Corrosion Loop as Equipment; Circuit as a component Setting values to represent properties to model circuit Circuit comprised of various components with varying rates, thicknesses and other properties When using RBI for piping inspection consider: Basis for RBI modeling may not be representative for all components of the circuit, such as diameter, pressure, corrosion rate, corrosion allowance and t-min Using average circuit corrosion rate from TML s/cml s may be nonconservative Thicknesses of components in the circuit may vary Be careful when using a single thickness measurement and corrosion rate for multiple TML s/cml s

Definition of Corrosion Loops Corrosion Loop must be properly defined: Corrosion Loops defined as equipment controlled together In similar operating service Expect similar corrosion mechanisms and rates Share IOW criteria alerts and alarms Controlled together operationally

Crude Unit PFD & Corrosion Loops CRUDE COLUMN OVRHD CONDENSERS OVRHD DRUM NAPHTHA KEROSENEVAPOR RETURN CRUDE COLUMN KEROSENE DRAW KEROSENE STRIPPER KEROSENE STRIPPER REBOILER KEROSENE LAGO UPPER REFLUX CRUDE COLUMN LAGOVAPOR RETURN LAGO LAGO STRIPPER DESALTER CRUDE/ CIRC. LAGO EXCHANGER LAGO CRUDE COLUMN AGO STRIPPER AGO COLD CRUDE PREHE AT EXCHANGERS CRUDE FROM S TORAGE CRUDE COLUMN WASH SUPP LY DESALTER TO CRUDE COLUMN WASH RETURN HOT CRUDE PREHE AT EXCHANGERS CRUDE HE ATER CRUDE BOTOMS TO VACUUMTOWER

Define Circuits Goal: To create common inspection strategies for each circuit Corrosion Circuit must be properly defined: Equipment with the same expected corrosion mechanisms and rates Same material of construction Same or very similar operating conditions Equipment thickness measurements and calculated corrosion rates should be manageable as a group Define piping boundaries Include all primary piping Piping bypasses, start-up/shut-down lines Piping up to PRD s Normally does not include utility piping (e.g. air, nitrogen, steam), PRD relief system downstream piping

Establishing IOW s Based on Damage Review Conducted 2 Approaches, Historical Operating & Limiting component Identify potentially active damage mechanisms for all fixed equipment and piping corrosion loops/circuits Assign estimated or measured damage based on service experience Identify process variables driving in-service damage Established limits for process variables affecting the integrity of equipment Identify process operation deviating from established limit for a predetermined amount of time Operating variables effecting reliable operation of the equipment Operating variables determined as Critical, Standard and/or Informational Appropriate limits for Critical and Standard windows Critical and Standard limits are normally established for a corrosion loop or system but are based on the equipment or component limiting the corrosion loop

Corrosion Loop Description Consists of the overhead of Crude Distillation Column through Overhead Condensers and to Overhead Accumulator Operates at an average ph of 6.0 (range of 4.8 to 8.0). Operating temperature ranges from 221 O F to 122 O F. The primary concerns in this loop are hydrochloric acid corrosion at or below the dew point and mix point/injection point corrosion near each of the injection points. All piping in this loop is carbon steel materials of construction. Specific Corrosion Mechanisms: Chloride corrosion due to Hydrochloric Acid for all materials of construction at temperatures below water dew point. Injection/Mix point corrosion (localized) due to use of ammonia, inhibitor and neutraliser use. SSC and HIC/SOHIC in Wet H 2 S service. Corrosion Under Insulation (CUI) potential at temperatures less than < 177 O C (350 O F)

Corrosion Circuit Definition Circuit 1 Carbon Steel Circuit 1 consists of piping from the top of C-21201 Crude Distillation Column (from Tray 1 to top head) to the overhead line Chemical Injection point. C-101 Top outlet: 221 O F Estimated Corrosion Rate Average 6 mpy Corrosion Type Localized Primary Damage Mechanism Aqueous HCl Secondary Damage Mechanism Potential aqueous H 2 S Specific Location Concerns Aqueous corrosion at or below the dew point in carbon steel overhead line

IOW s Process Equipment D-101 Overhead line Sample Location Accumulator Sour Water Overhead line Test Analysis ph 5.5-6.5 Chloride < 50 ppm Fe <2.0 Injection points Frequency 3 times/week 3 times/week 3 times/week 3 times/week Process Alert Equipment D-101 ph <5.5 or >7.5 Chloride > 50 ppm Fe > 2.0 ppm Alert Response Check neutralizer injection Check caustic injection Check ammonia injection

Corrosion Loop Definition Consists of the HVGO draw at 577 O F to HVGO pumps A/B and split with a portion returning to the column under flow control as wash oil. A split HVGO stream is cooled in the hot preheat train exchangers A/B and cold preheat train exchangers, combined with MVGO and cooled to 150 O F and sent to storage. HVGO stream contains an average of 2.5 wt% sulfur (maximum 3.9%) and average 0.9 (maximum 1.8) TAN. Operating temperature ranges from 554 O F from the draw tray down to 150 O F for product rundown Primary concern in this loop is for Sulfidation and/or Naphthenic Acid corrosion which are most active in circuits operating above 450 O F Corrosion Loop contains a mixture of 5 Cr ½ Mo, Type 316L and carbon steel materials of construction

Corrosion Loop Definition Specific Corrosion Mechanisms: Sulfidation and/or Naphthenic Acid corrosion based on % total sulfur and TAN in HVGO stream and temperatures < 350 O F Injection/Mix point corrosion (localized) due to use of water and chemical inhibitor use for Circuit 2 and Circuit 5 Corrosion Under Insulation (CUI) potential at temperatures less than < 350 O F Corrosion rates are based on: Modified McConomy curves for sulfidation rates API 581 for rates based on the presence of sulfur and naphthenic acid Corrosion is generalized in piping straight runs and can be highly localized in turbulent flow areas when TAN values are greater than 1.5 Rate and thinning type (generalized and localized) is influenced by sulfur, TAN and velocity

Corrosion Circuit Definition Circuit 1 5 Cr-½ Mo Circuit 1 consists of piping from Tray #4 in Vacuum Column to the chemical injection point. Vacuum Column draw: 554 O F Estimated Corrosion Rate Average Sulfidation (generalized) 6.2 mpy Sulfidation/Naphthenic Acid (localized) 6.8 mpy Primary Damage Mechanism Sulfidation and/or Naphthenic Acid corrosion Secondary Damage Mechanism None Specific Location Concerns Possible general corrosion in deadlegs associated with bypasses; localized corrosion potential in turbulent flow areas such as direction changes, piping associated with pumps, reducers, mixed phase flow, etc.

IOW s Process Equipment Sample Location Test Analysis HVGO HVGO Sulfur 2.5% TAN 1.0 Frequency HAC Runs Process Equipment Alert Alert Response HVGO >3 Sulfur > 1.25 TAN Review crude blending and check corrosion probes

Approaches to Inspection Planning for Piping Handling of CML/TML data from inspection for analysis Use circuit data for analysis with careful use of TML/CML data High Quality, sanitized UT (don t mix with RT or other methods) Select corrosion rates for analysis Select representative measured thickness for analysis Develop inspection due date, coverage and methods Interval-Based vs. Risk-Based ½ life interval basis does not consider COF Risk-Based interval may not reflect risk of all components Quantitative and even qualitative risk analysis at the component and TML/CML level is not practical

CML/TML Data All Data

CML/TML Data Carbon Steel, UT and RT Methods

CML/TML Data Carbon Steel, UT Method Only

Interval-Based vs. Risk-Based Programs Interval-Based t-min & ½-life determination Often includes a maximum frequency No COF consideration Probability based on damage rate only Nominally B-Level effective inspection Risk-Based Optimized inspection based on risk Reduced inspections for low consequence equipment Credit for probability assessment Multiple levels of inspection effectiveness

Inspection Planning Approaches ½ Life Inspection performed on or before equipment reaches ½ life based the shorter of t-min and corrosion rate or max interval Risk Target Risk escalates with time requiring inspection on or before the date the risk target is reached (POF/Damage Factor or COF) Inspection Frequency performed on or before a maximum frequency as determined by risk based matrix location Frequency Adjustment Factor performed on or before a remaining life adjusted interval, determined by risk based matrix location

Risk and Inspection Planning for Piping Quantitative RBI and many qualitative approaches are too complex for managing piping components TML/CML inspection can be managed at circuit or individual TML/CML locations POF can vary significantly among components within a circuit while COF is relatively constant COF can be used for piping components and TML/CMLs to adjust inspection dates and coverage Inspection intervals can be modified with consideration for COF (similar to API 570 classification) Remaining life calculations and adjustment factors can be defined with consideration for COF in place of ½ life

Probability 5 10 10 10 5 5 4 15 15 10 10 5 3 25 25 15 10 5 2 25 25 15 15 10 RISK High Medium High Medium Low 1 25 25 15 15 10 A B C D E Consequence Risk Matrix with Maximum Inspection Interval

Probability 5 0.5 0.5 0.5 0.9 0.9 4 0.3 0.3 0.5 0.5 0.9 3 0.2 0.3 0.3 0.5 0.9 2 0.2 0.2 0.3 0.3 0.5 RISK High Medium High Medium Low 1 0.2 0.2 0.3 0.3 0.5 A B C D E Consequence Risk Matrix with Remaining Life Adjustment Factor

Probability 5 B B B A A 4 C C B B A 3 C C C B A 2 C C C C B RISK High Medium High Medium Low 1 C C C C B A B C D E Consequence Risk Matrix with Inspection Effectiveness

Piping Inspection Planning Determine the basis for POF, Risk and inspection planning Define inspection & coverage can be applied to circuit Inspection of circuit can be based on remaining life and/or POF of components based on TML s/cml data Inspection Effectiveness, i.e. coverage percentage, can be defined for low risk circuits, higher coverage to high risk circuits Requires good integration between RBI and IDBMS program for information exchange between modules

Conclusions Starting with defining corrosion loops and circuits, combining equipment and piping Build out your RBI program for equipment and selectively model a representative portion of the piping circuit Average primary component Limiting component Other Determine logic for adjusting piping inspection, using risk/consequence to adjust interval or scope Adjusting life fraction (1/2 life) Adjusting scope (number of inspection points)

Conclusions Model Corrosion Loop as Equipment; Circuit as a component Can use average or weighted average values to represent properties to model circuit Circuit comprised of various components with varying rates and other properties When using RBI for piping inspection consider: Basis for RBI modeling may not be representative of all components in the circuit, such as component remaining life, pressure, corrosion rate, corrosion allowance and t-min Average corrosion rates may be non-conservative for some components Thicknesses of some components in the circuit may vary Be careful when using a single thickness measurement and corrosion rate for multiple TML s/cml s