Construction. Polymeric membrane for roof waterproofing. Product Description. Tests

Similar documents
Construction. Sarnafil TS Polymeric membrane for roof waterproofing. Product Description

Construction. Sarnafil G Felt. Polymeric membrane for roof waterproofing. Product Description

PRODUCT DATA SHEET Sarnafil TG Felt

Roofing. Polymeric sheet for roof waterproofing. Product Description. Tests. Product Data Sheet Edition _1

Roofing. Sarnafil G EL Felt. Polymeric membrane for roof waterproofing. Product Description

PRODUCT DATA SHEET Sarnafil TS 77-15

Construction. Sarnafil TS 77-18E Polymeric membrane for roof waterproofing. Product Description

Construction. Sarnafil TS 77-20E Polymeric membrane for roof waterproofing. Product Description

Polymeric membrane for roof waterproofing

PRODUCT DATA SHEET Sarnafil TS 77-20

Roofing. Sarnafil S EL. Polymeric membrane for roof waterproofing. Product Description

PRODUCT DATA SHEET Sarnafil TS 77-18

PRODUCT DATA SHEET Sarnafil TS 77-20

PRODUCT DATA SHEET Sarnafil G EL

Roofing. Sika-Trocal SG 1.5 mm. Polymeric membrane for roof waterproofing. Product Description

Construction. Sarnafil S EL. Polymeric membrane for roof waterproofing. Product Description

PRODUCT DATA SHEET Sarnafil G EL

Construction. Sika-Trocal SGmA 1.5 mm. Polymeric membrane for roof waterproofing. Product Description

Construction. Sarnafil S EL. Polymeric membrane for roof waterproofing. Product Description

Sarnavap 1000E is an unsupported vapour control layer based on PE-LD (Low Density Polyethylen).

Construction. S-Vap 5000E SA Self-adhesive Vapour Barrier. Product Description

Construction. SikaProof A. Fully bonded FPO sheet waterproofing membrane system for basement and other below ground structures. Product Description

Roofing. Sarnavap 500E. Vapour control layer. Product Description. Tests. Product Data. Form. Storage

Sarnavap 5000E SA Vapour Control Layer

PRODUCT DATA SHEET SikaProof A

Construction. Adhesive for Sarnafil G Felt roof waterproofing membranes. Product Description. Tests. Product Data. Form

Construction. Fully bonded FPO sheet membrane waterproofing system for basement and other below ground structures. Product Description.

Roofing. Sarnacol Adhesive for Insulation Boards. Product Description. Product Data. Polyurethane-based humidity-hardening one-pack adhesive

Roofing. Carrier Membrane SA. Self-adhesive Carrier Membrane. Product Description. Tests. Product Data. Form. Storage

Primer and Moisture Control for Wood Floor Bonding with Elastic SikaBond Adhesives on Difficult Substrates

PRODUCT DATA SHEET. SikaProof A

1-part Flexible Sealant for Concrete and Masonry Facades

SikaProof A. Fully bonded FPO sheet membrane waterproofing system for basements and other below ground structures. Product Description

Low Viscosity, Solvent Free Elastic Adhesive for Wood Flooring. Solvent free Odourless Recyclable tin pail EMICODE EC 1 PLUS R, very low emission

3-Part Epoxy Grouting System for Pile Capping

Injectable Hose With Integral Valves for Sealing Construction Joints in Watertight Structures

Sika-Trocal C200 Adhesive. Sika-Trocal C200 is an adhesive to bond certain insulation boards on approved substrates.

Waterproofing and Damp-proofing Cementitious Slurry

Construction. Injectable Hose for Sealing Construction Joints in Watertight Structures. Product Description. Tests. Product Data

Sikatherm PIR GT. PIR Thermal Insulation Board. Product Description. Product Data

Construction. 2-part High-build Solvent Free Epoxy Coating. Product Description. Product Data. Storage

Part of the Sikaplan WT Membrane System

Construction. Fully bonded FPO sheet membrane waterproofing system for basement and other below ground structures. Product Description

Coloured Mineral Dry Shake Floor Hardener

Construction. Solvent Free Elastic Adhesive for Wood Flooring. Product Description

Conforms to the requirements of ETAG Certificate: European Technical Approval No. ETA-05/0265

Part of the Sikaplan WT Membrane System

According German Standard DIN part 1. Standard range of PVC-P based flexible waterstops for movement (expansion) and construction joint sealing

Construction. Fully bonded FPO sheet membrane waterproofing system for basement and other below ground structures. Product Description

METHOD STATEMENT Sika Drain-850 Geo

PRODUCT DATA SHEET Sikalastic -501 Roofseal Plus

Construction. Mineral dry shake floor hardener. Product Description. Product Data. Tests. Form. Storage

Installation Instructions ALUTRIX 600 ALUTRIX FR

ROOFING SINGLE PLY MEMBRANES

Construction. Non-metallic Dry Shake Floor Hardener. Product Description. Tests. Product Data. Storage

PRODUCT DATA SHEET Sikalastic Rapid-721

INOFIN FPO roofing membrane

TECHNICAL DATA SHEET SIKADUR 31 RAPID 1.2KG

MODIFIED BITUMINOUS SHEET AIR / VAPOUR BARRIERS SELF ADHESIVE

Waterproofing membrane FATRAFOL 810

TECHNICAL DATA SHEET SIKABOND AT METAL GREY 300CC

SealArm Tape TPE. Building & Joint Sealants T E C H N I C A L D A T A S H E E T. Uses. Features and Benefits

ELASTOFLEX SA P ELASTOFLEX SA P mineral

1-part polyurethane pourable self levelling floor joint sealant

Roofing and waterproofing synthetic membrane

Construction. High performance joint sealing system. Product Description. System Data Sheet Edition _1. 1 Sikadur Combiflex SG system 1/8

Construction. Adhesive for bonding Carbon Fibre & Steel reinforcement. Product Description. Tests

TECHNICAL DATA SHEET SIKADUR 31 CF NORMAL 6KG

Construction. Type N and Type R. 2-part epoxy adhesive Part of the Sikadur -Combiflex System. Product Description. Tests

Roofing and waterproofing synthetic membrane

Product Data Sheet Product n Description Uses tio tru Characteristics / C Advantages Tests Approval / Standards

2-part epoxy impregnation resin

Sika Hydrotite CJ K

SECTION TPO WATERPROOFING MEMBRANE FOR FLAT ROOFS INSTALATION

1-part elastic joint sealant and multipurpose adhesive

2-part epoxy impregnation resin

PRODUCT DATA SHEET Sikadur -32 Normal

ROOFING EPDM ELASTOMERIC SHEET ROOFING FULLY ADHERED- CONVENTIONAL

Construction. Adhesive for bonding reinforcement. Product Description. Tests

SIKAPROOF A WATERPROOFING MEMBRANE. Product. Scope. Building Regulations. Appraisal No. 852 [2014] Appraisal No. 852 (2014) Amended 24 April 2018

Sikadur -330 is a two part, thixotropic epoxy based impregnating resin / adhesive.

Construction. Adhesive for bonding reinforcement. Product Description. Tests. Product Data Sheet Edition 16 December 2014

REOXTHENE TECHNOLOGY BITULIGHT LINE -5 C WATERPROOFING MEMBRANE WITH REVOLUTIONARY TECHNOLOGY

J41 Reinforced bitumen membrane roof coverings

Sika Tricomer Compression Seals

Two-component solvent-free polyurethane adhesive used in the construction of SikaRoof MTC Cold Bonding. Twin-pack product

3-part thixotropic epoxy patching mortar

1-part elastic joint sealant and multipurpose adhesive

Footfall sound dampening system for wood flooring

Sikadur -Combiflex CF Adhesive Type N and Type R are thixotropic two part adhesives based on epoxy resins and fillers.

REOXTHENE TECHNOLOGY FLEXO-LIGHT SBS PROFESSIONAL LINE RANGE OF PRODUCTS FORMULATED AND DEVELOPED EXPRESSLY FOR ROOFING PROFESSIONALS -20 C

Sikafloor -264 is a two part, economic, solvent-free coloured epoxy resin, suitable for use under hot climate condition.

Installation Specification. Preface

Construction. Tricosal Waterstops - Tricomer. Waterstops for joint sealing in watertight concrete construction according to DIN and DIN

Sealing profiles which swell in contact with water.

PRODUCT DATA SHEET Sikadur 31 CF Normal (formerly Sikadur 731)

Swellable joint sealing profiles

Construction. 2-part epoxy impregnation resin. Product Description. Product Data. Tests. Form. Product Data Sheet Edition 4 March 2015

Firestone UltraPly TPO The light colored roofing choice

Product Data Sheet Sikadur -31 CF Normal Product Description Uses ruction Const Characteristics / Advantages

Transcription:

Construction Product Data Sheet Edition: 27/01/2013 Identification no: 02 09 10 05 200 0 120000 Version: GCC Sarnafil TG 76-12 Felt Sarnafil TG 76-12 Felt Polymeric membrane for roof waterproofing Product Description Sarnafil TG 76-12 Felt (thickness 1.2 mm) is a multi-layer, synthetic roof waterproofing sheet based on premium-quality flexible polyolefins (FPO), containing stabilizers, with inlay of glass non-woven and Polyester fleece backing according to EN 13956. Sarnafil TG 76-12 Felt is a hot air weldable, UV-resistant roof membrane, designed to use in all global climatic conditions. Sarnafil TG 76-12 Felt is produced with an inlay of glass non-woven for dimensional stability. Sarnafil TG 76-12 Felt is used for adhered roofs. Sarnafil TG 76-12 Felt has no built-in stress at the time of production and has a fully encapsulated carrier with no risk to delamination or water-wicking. The dimensional stability of Sarnafil TG 76-12 Felt is excellent. Suitable for use in hot and tropical climatic conditions. Uses Characteristics / Advantages Sarnafil TG 76-12 Felt is used as a waterproofing membrane for: Adhered roofs Outstanding resistance to weathering, including permanent UV irradiation Excellent flexibility in cold temperatures No built-in stress at the time of production High dimensional stability High resistance against impact load Excellent weldability No risk of delamination or water-wicking Compatible to old bitumen Recyclable Tests Approval / Standards Sarnafil TG 76-12 Felt is designed and manufactured to meet the most international recognised standards. Polymeric sheets for roof waterproofing according to EN 13956, certified by notified body 1213-CPD-3914 and provided with the CE-mark. Reaction to fire according to EN 13501-1. External fire performance tested according to ENV 1187 and classified according to EN 13501-5: B ROOF(t1). Official Quality Approvals and Agrement Certificates and approvals. Monitoring and assessment by approved laboratories. Quality Management system in accordance with EN ISO 9001/14001. Sarnafil TG 76-12 Felt 1/5

Product Data Form Flexible sheet membrane Appearance / Colours Surface: Matt Packaging Colours: Top surface: Bottom surface: Beige Grey (nearest RAL 7040) Black Sarnafil TG 76-12 Felt standard rolls are wrapped individually in a blue PE-foil. Packing unit: Roll length: Roll width: Roll weight: see price list 20.00 m 2.00 m 60.00 kg Storage Storage Conditions / Shelf Life Rolls must be stored in a dry area at temperatures between 5 C and 30 C in a horizontal position on pallets. Protect from direct sunlight, heat, rain and snow. Product does not expire if correctly stored in original sealed and undamaged packaging. Do not stack pallets of rolls during transport or storage. Technical Data Product Declaration EN 13956 Visible defects Pass EN 1850-2 Length 20 m (-0 % / +5 %) EN 1848-2 Width 2 m (-0.5 % / +1 %) EN 1848-2 Straightness 30 mm EN 1848-2 Flatness 10 mm EN 1848-2 Effective thickness 1.2 mm (-5% / +10 %) EN 1849-2 Mass per unit area 1.5 kg/m 2 (-5 % / +10 %) EN 1849-2 Water tightness Pass EN 1928 Effects of liquid chemicals, including water On request EN 1847 External fire performance ENV 1187 Part 1-4 B ROOF(t1) 20 EN 13501-5 Reaction to fire Class E EN ISO 11925-2, classification to EN 13501-1 Hail resistance EN 13583 rigid substrate flexible substrate 17 m/s 25 m/s Joint peel resistance 300 N/50 mm EN 12316-2 Joint shear resistance 500 N/50 mm EN 12317-2 Water vapour transmission properties = 150 000 EN 1931 Tensile strength EN 12311-2 longitudinal (md) 1) 800 N/50 mm transversal (cmd) 2) 600 N/50 mm Sarnafil TG 76-12 Felt 2/5

Elongation EN 12311-2 longitudinal (md) 1) 50 % transversal (cmd) 2) 50 % Resistance to impact EN 12691 hard substrate soft substrate 600 mm 1250 mm Resistance to static load EN 12730 soft substrate rigid substrate 20 kg 20 kg Dimension stability EN 1107-2 longitudinal (md) 1) 0.2 % transversal (cmd) 2) 0.1 % Foldability at low temperature -30 C EN 495-5 UV exposure Pass (> 5 000 hr / grade 0 ) EN 1297 Exposure to bitumen 3) Pass EN 1548 1) md = machine direction 2) cmd = cross machine direction 3) Sarnafil T is compatible to old bitumen System Information System Structure Wide range of accessories is available e.g. prefabricated parts, roof drains, scuppers and walkway pads. The following materials are strongly recommended: Sarnafil T 66-15 D Sheet for detailing Sarnafil T Metal Sheet Sarnabar Sarnafil T Prep / Sarnafil T Wet Task Set Sarnacol T 660 Solvent T 660 Sarnacol 2142 S Sarnafil T Clean Application Details Substrate Quality The substrate surface must be uniform, smooth and free of any sharp protrusions or burrs, etc. The supporting layer must be compatible to the membrane and free of oil and grease. Cut open any blisters in the old waterproofing and repair. The safety of the existing roof assembly in terms of wind uplift must be ensured. Any insufficiently secured sections or components (e.g. chippings, slating etc.) must be removed to provide a smooth surface. The curing of Sarnacol 2142 S requires moisture. The base layer may therefore be slightly moist (no puddles). If the relative humidity is below 35 % moisten the adhesive after it has been applied. Application Conditions / Limits Temperature Compatibility Permanent ambient temperature during use is limited to +50 C. Sarnafil TG 76-12 Felt may be installed on all thermal insulations and levelling layers suitable for roofing. No additional separation layer is required. Sarnafil TG 76-12 Felt is suitable for installation directly on top of existing, carefully cleaned, level bituminous roofing, e.g. re-roofing over old flat roofs. Colour changes in membrane surface may occur in case of direct contact with bitumen. Sarnacol 2142 S single-component PUR adhesive is designed for adhering feltbacked Sarnafil TG 76-12 Felt to standard insulations and substrates. Adhering Sarnafil TG 76-12 Felt by means of Sarnacol 2142 S is particularly suitable for re-roofing over old bitumen waterproofing. (Not suitable for re-roofing over synthetic, rubber or ECB roofing). Sarnafil TG 76-12 Felt 3/5

Installation Instructions Installation Method / Tools Notes on Installation / Limits Installation procedure: According to the valid installation instructions for systems with Sarnafil TG 76 Felt-types for fully adhered roofs. Adhering: - Use Sarnacol 2142 S only at temperatures above +5 C - Use only on slopes less than 10 - Lay out and align Sarnafil TG 76-12 Felt with the felt-free edge along upstands. - From the end of the run fold back Sarnafil TG 76-12 Felt to approximately halfway. - Using a roller (pile length approx. 15 mm) apply Sarnacol 2142 S evenly over the surface exposed by the folded back Sarnafil sheet. - Very absorbent surfaces, e.g. mineral fibre, require two coats of adhesive. The first coat of approximately 300 gr/m 2 must be completely dry before applying the second. - Roll the folded back Sarnafil TG 76-12 Felt sheet immediately into the wet adhesive. - Press down the Sarnafil TG 76-12 Felt with a weighted roller (50 kg). - Fold back the other half of the Sarnafil TG 76-12 Felt membrane. - According to site conditions (roof geometry) adjoin the next Sarnafil sheet at the end of the adhered membrane to form a butt joint or lay the following rolls alongside with overlapped joints. Peeling protection must be provided at all upstands and roof penetrations as the work proceeds. The roof build up must be mechanically secured by a peel stop using Sarnabar. Welding: - The adhered Sarnafil TG 76-12 Felt may only be welded together after the adhesive bond is sufficiently strong. - Butt joints should be covered with a Sarnafil TG 66-15 cover strip welded on either side. Welding Method: Before welding the seams are prepared with Sarnafil T Prep. Overlap seams are welded by electric hot air welding equipment, such as manual hot air welding machines and pressure rollers or automatic hot air welding machines with controlled hot air temperature. Recommended type of equipment: Leister Triac PID for manual welding Sarnamatic 661 plus for automatic welding Welding parameters including temperature, machine speed, air flow, pressure and machine settings must be evaluated, adapted and checked on site according to the type of equipment and the climatic situation prior to welding. The effective width of welded overlaps by hot air should be minimum 20 mm. The seams must be mechanically tested with screw driver to ensure the integrity / completion of the weld. Any imperfections must be rectified by hot air welding. Installation works must be carried out only by Sika instructed roofing contractors. Temperature limits for the installation of the membrane: Substrate temperature: -30 C min. / +60 C max. Ambient temperature: -20 C min. / +60 C max. Installation of some ancillary products, e.g. contact adhesives / cleaners is limited to temperatures above +5 C. Please observe information given by latest Product Data Sheets. Special measures may be compulsory for installation below +5 C ambient temperature due to safety requirements in accordance with national regulations. Sarnafil TG 76-12 Felt 4/5

Construction Value Base All technical data stated in this Product Data Sheet are based on laboratory tests. Actual measured data may vary due to circumstances beyond our control. Local Restrictions Please note that as a result of specific local regulations the performance of this product may vary from country to country. Please consult the local Product Data Sheet for the exact description of the application fields. Ecology, Health and Safety Information Protective Measures Transportation Class Disposal Legal Note A Safety Data Sheet following EC-Regulation 1907/2006, Article 31 is not needed to bring the product to the market, to transport or to use it. The product does not damage the environment when used as specified. Fresh air ventilation must be ensured, when working (welding) in closed rooms. Local safety regulations must be observed. The product is not classified as hazardous good for transport. The material is recyclable. Disposal must be according to local regulations. Please contact your local Sika sales organisation for more information. The information, and, in particular, the recommendations relating to the application and end-use of Sika products, are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika s recommendations. In practice, the differences in materials, substrates and actual site conditions are such that no warranty in respect of merchantability or of fitness for a particular purpose, nor any liability arising out of any legal relationship whatsoever, can be inferred either from this information, or from any written recommendations, or from any other advice offered. The user of the product must test the product s suitability for the intended application and purpose. Sika reserves the right to change the properties of its products. The proprietary rights of third parties must be observed. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request. All products are manufactured under a management system certified to conform to the requirements of the quality, environmental and occupational health & safety standards ISO 9001, ISO 14001 and OHSAS 18001. Sika UAE L.L.C P.O. Box 126212 Dubai, United Arab Emirates Phone: +971 4 4398200 info@ae.sika.com Sika Gulf B.S.C (c) P.O. Box 15776 Adliya, Kingdom of Bahrain Phone: +973 17738 188 sika.gulf@bh.sika.com Sika Saudi Arabia Co. Ltd P.O. Box 58647, Riyadh 11583, Kingdom of Saudi Arabia Phone: +9661 2176532 info@sa.sika.com Sarnafil TG 76-12 Felt 5/5