HACKER SOUND MAT II, to create a quieter living environment while meeting demanding project specifications in multi-family construction.

Similar documents
FIRM-FILL SCM-400 can be installed under a FIRM-FILL Gypsum Concrete Floor Underlayment to produce an exceptional vibration isolation floor system.

When demanding consistent quality, specify FIRM-FILL SCM-250 to assist in achieving highly improved IIC sound performance in multifamily

Build higher and faster with FIRM-FILL CMD (corrugated steel deck) from Hacker Industries, Inc., the leader in pourable floor underlayments.

FIRM-FILL is Hacker Industries, Inc. s underlayment solution over plywood or OSB subfloors in apartments, condos, hotels and motels.

GYP-SPAN RADIANT, a crack-resistant gypsum concrete is designed for use over hot water tubes or electric cables in radiant heat projects.

PRODUCT GUIDELINES Hacker. Industries, Inc.

USG LEVELROCK BRAND SOUND REDUCTION BOARD SRB

The original. insulation.

Levelrock CSD. Floor Underlayment. The Lightweight Flooring Solution

A. Description of Work: Work of this section includes self leveling underlayment for interior finish flooring but is not limited to, the following:

Triton DCI Decoupling Mat

GenieMat FF. Floating Floor Systems for Airborne & Impact Sound and Vibration Isolation. It s not magic, it s engineering. Impact Sound Control

Floor Underlayment Selector High-Strength Flooring Solutions

Floor Underlayment Selector High-Strength Flooring Solutions

The original. insulation.

LEGACY REPORT. (800) (562) A Subsidiary of the International Code Council

Division : Gypsum Cement Underlayment

Acoustic Treatment

DIVISION: FINISHES SECTION: ACOUSTIC TREATMENT REPORT HOLDER: ECORE INTERNATIONAL, INC.

Triton BK Backer Board & Tile Underlayment

Floor Insulation Underlayment Section Sound Control Matting

ENKASONIC FLOOR UNDERLAYMENT 9110

Product Guide Specification Pliteq GenieMat FF06, GenieMat FF10, GenieMat FF17, GenieMat FF25, GenieMat FF50, GenieMat FF75

Triton WP Waterproof Membrane

LISTING INFORMATION OF International Beams - IB Series Joists SPEC ID: 27316

FIRE & SOUND IN MULTIFAMILY FLOORS DESIGN CONSIDERATIONS

LISTING INFORMATION OF Mitek Design No. MCI/WI SPEC ID: MiTek Canada, Inc. 100 Industrial Road Bradford, ON L3Z 3G7 Canada

Floor SoundprooFIng Made Simple

C R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E 90 AND ASTM E 492. Rendered to. ECORE International. Series/Model: Base 10

C R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E 90 AND ASTM E 492. Rendered to. ECORE International. Series/Model: QT4005

C R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E 90 AND ASTM E 492. Rendered to. ECORE International. Series/Model: QT4002

C R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E 90 AND ASTM E 492. Rendered to. ECORE International. Series/Model: Expona

C R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E 90 AND ASTM E 492. Rendered to. ECORE International. Series/Model: Forest rx

Multifamily, Commercial, Single-Family, Renovation. A Reputation You Can Stand On

Stark Truss Company, Inc. Revised December 14, 2018

3 in 1 Accoustical Underlay

Sound Control Solutions in Floor/Ceiling Assemblies

DIVISION 9 - SECTION QTscu Re-bonded Recycled Rubber Impact Sound Insulation Patent No. RE 41,945

ARCHITECTURAL AND STRUCTURAL NOISE CONTROL SOLUTIONS

PLYWOOD FLOATING FLOOR

Silencer Rubber Underlayment

QT 4003 (3mm), QT 4005 (5mm) & QT 4010 (10mm)

RSIC ACOUSTIC ASSEMBLY

DIVISION: FINISHES SECTION: ACOUSTIC TREATMENT REPORT HOLDER: HOMASOTE COMPANY

FLOOR CEILING ASSEMBLY

FOR: CEMCO - California Expanded Metal Products Co. Sound Transmission Loss Test

FIRM-FILL High Strength

Presented By: Jim O Neill. Acoustics

RSIC ACOUSTIC ASSEMBLY

SPECIFICATIONS ADVANTAGES. For more information on this product or to order samples call or visit our website at builddirect.

A. Section includes hydraulic-cement-based, polymer-modified, self-leveling underlayment for application below interior floor coverings.

1. The subfloor must be structurally sound and able to withstand live and dead loads with a deflection limitation of L/360.

ULTIMATE SOUND CONTROL SYSTEMS


RSIC ACOUSTIC ASSEMBLY

Action QuickCourt R Modular Athletic Flooring

RSIC THE REVOLUTION IN NOISE CONTROL

Suggested Specification for Tri-Patch Versatile Concrete Patching Compound

Boise Cascade Company Revised June 25, 2018

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK Order No October 15, REPORT NO CRT-002d3

Product Guide Specification Pliteq GenieMat RST-02, RST-05, RST-10, RST-12, RST-15

CONTRACT NUMBER: W912DQ-08-C % CORRECTED DESIGN 28 JULY 2008

RSIC ACOUSTIC ASSEMBLY

PinkWood Ltd. Revised September 29, 2017

SECTION GYPSUM BOARD

LISTING INFORMATION OF Weyerhaeuser - TJI Joists SPEC ID: 26948

Firestone Polyiso Boards

Chevy Chase Club June 30, 2008 Bowie Gridley Architects

INSTALLATION INSTRUCTIONS

Signatures are required on this document for an official laboratory test report. Copies of this document without signatures are for reference only.

GenieClip. Sound Isolation Clips. It s not magic, it s engineering. Impact and Airborne Sound Control

FIRE & SOUND MANUAL ARCHITECT VERSION 4.16

FIRE & SOUND MANUAL ARCHITECT VERSION 6.17

SECTION WOOD FLOORING

It s not magic, it s engineering. Impact and Airborne Sound Control. GenieClip. US Patent No. 7,895,803

LOOSE LAY INSTALLATION GUIDE PAGE 1 of 6

SECTION GYPSUM BOARD SYSTEM

March 27, Laticrete International Attn: Steve Fine 1 Laticrete Park N. Bethany, CT Dear Mr. Fine,

RESILIENT CORK TILE 3 PART SPECIFICATION #Z 624

NATIONAL GYPSUM COMPANY 2-Hour Area Separation Wall System

SECTION GYPSUM BOARD SYSTEM

PLANK AND LARGE PANEL STABILIZER BARS APPLICATION GUIDE

RESILIENT SOUND ISOLATION CLIPS

Design No. L565. Design No. L565

SECTION GYPSUM BOARD ASSEMBLIES

SECTION SHEET MEMBRANE SOUND REDUCTION, CRACK ISOLATION / JOINT BRIDGING, AND WATERPROOFING

HAMBRO COMPOSITE FLOOR SYSTEM

Brand Underlayment. Submittal Sheet FIBEROCK

SECTION SHEET MEMBRANE SOUND REDUCTION, CRACK ISOLATION / JOINT BRIDGING, AND WATERPROOFING

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued October 1, Legacy report on the 1997 Uniform Building Code

REPORT NUMBER: SAT-005 ORIGINAL ISSUE DATE: September 14, 2012 REVISED DATE: N/A

SOUND & VIBRATION CONTROL FOR BUILDINGS. ISO-SEP 25HD High Dimple Rubber Isolation Mat Specification

Foil Back Gypsum Board

It s not magic, it s engineering. Impact and Airborne Sound Control. GenieClip. US Patent No. 7,895,803 U.K. VERSION

Thermasheath -3. Insulation for the Building Envelope ROOF WALL SPECIALTY

FLOORING TREATMENT

DIVISION 9 - SECTION ECOSilence Recycled Rubber Sound Underlayment US Patent No. RE 41,945

SECTION WOOD STRIP FLOORING

RSIC ACOUSTIC ASSEMBLY

Transcription:

HACKER SOUND MAT II HACKER SOUND MAT II, to create a quieter living environment while meeting demanding project specifications in multi-family construction. HACKER SOUND MAT II, a recycled rubber sound control mat, installed under a FIRM-FILL Gypsum Concrete Floor Underlayment to produce an exceptional vibration isolation floor system. Helps contribute towards LEED points Specify with FIRM-FILL Gypsum Concrete Floor Underlayments for additional LEED credits Reduces sound transmission between floors; improves STC and IIC ratings Over 100 UL Fire Rated Design listings System rated for commercial and residential use ASTM C627 Installed by trained Licensed Applicators

1 - FLOOR COVERING / 2 - FIRM-FILL BRAND GYPSUM CONCRETE / 3 - HACKER SOUND MAT II / 4 - PLYWOOD OR OSB / 5 - NOMINAL WOOD JOIST 6 - BATT INSULATION / 7 - PARALLEL CHORD TRUSS / 8 - TJI JOIST / 9 - RESILIENT CHANNEL / 10 - GYPSUM WALLBOARD / 11-6 CONCRETE IIC + STC + Performance in wood-frame and concrete structures Improves Impact Insulation Class (IIC) ratings Improves Sound Transmission Class (STC) ratings Allows vapor to pass through to prevent trapped moisture Class A Fire-rated Product Installed by Hacker Industries trained Licensed Applicators 2017 Hacker Industries, Inc. FIRM-FILL and the associated logos are trademarks of Hacker Industries, Inc., Newport Beach, CA. Requires dryin (building must be fully enclosed before installation) Install isolation barrier around perimeter of floor May not be used as a vapor barrier Install Hacker Sound Mat II with dimples down L/360 Deflection must not exceed L/360 live or dead load Tape all seams with duct tape or 2 wide tape Do not use Mechanical Fasteners Install FIRM-FILL Brand Gypsum Concrete Hacker Industries, Inc. Architect Binder Hacker Sound Mat II 2017 Must be used with FIRM-FILL Gypsum Concrete Apply Hacker TopCoat SP when specified Robinson Wheel tested Light Commercial Install finished floor covering only when completely dry 133

HACKER SOUND MAT II TECHNICAL DATA PROPERTIES Roll Weight 90 lb (40.8 kg) Thickness 1/4 in (6 mm) nominal Width 54 in (137.16 cm) Core Color Black recycled rubber Packaging Length 30 ft (9.14 m) Total Square Feet 135 ft² (41.15 m²) Steiner Tunnel Test Class B Pill Test DOC-FF 1-70 Passes Compression Set 601/12131 15% Benefits A 1/4 sound control mat designed to control noise in multi-family projects Integral part of an exceptional vibration isolation floor system Composed of recycled tire rubbers Specify with a FIRM-FILL Gypsum Concrete Floor Underlayment Helps contribute points to LEED project certification Installed only by trained Licensed Applicators across North America Product Description A durable, environmentally-friendly sound control mat composed of recycled rubber that helps increase STC and IIC values to create a quieter living environment. Ideal for all types of wood frame construction, Hacker Sound Mat II features a quick and easy dry laid installation. Specify Hacker Sound Mat II with a 1-1/4 FIRM- FILL Gypsum Concrete topping for the ultimate sound performance system. Limitations Shall not be used in exterior locations, below grade or where continuous exposure to moisture is likely. Shall not be used without a FIRM-FILL Gypsum Concrete topping. Structure shall be designed so that deflection does not exceed L/360 live or dead load. Certain floor coverings, such as marble, limestone, travertine and wood, may have more restrictive deflection limits. Consult the appropriate floor covering manufacturer for their recommendations. Do not use mechanical fasteners to install Hacker Sound Mat II, as mechanical fasteners conduct impact sound, reducing acoustical isolation. Hacker Sound Mat II shall be installed with a perimeter isolation strip. Hacker Sound Mat II is one component of an effective sound attenuation control system. Care must be taken in the installation of all components to ensure the ultimate design performance. Published acoustical and fire system tests were conducted under controlled laboratory and/or field conditions and reflected results are applicable only to those specific assemblies. Installation Before, during and after installation, the building must be enclosed and the temperature maintained at a minimum of 50 F (10 C). Prior to installation, the subfloor shall be structurally sound (L/360), broom cleaned, dry and free from oil, grease, paraffin, laitance, wax or other contaminants. 134 Hacker Industries, Inc. Architect Binder Hacker Sound Mat II 2017

INSTALLATION(cont.) Attach perimeter isolation strip or approved alternative to the walls, conduit, flanges, ballasts, etc. in order to isolate or break the vibration transmission path between the floor and wall. Reinforcement is recommended in doorways and other high traffic or transition areas. Lay Hacker Sound Mat II onto the subfloor with dimples DOWN. The mat shall lay flat, even and uniform. Hacker Sound Mat II shall be pushed up tightly to the isolation barrier previously installed around the perimeter of the floor. Use a high-quality duct tape to tape the seams. Install FIRM-FILL Gypsum Concrete at a minimum of 1-1/4 (32 mm). Refer to Hacker Industries, Inc. most recent FIRM-FILL Gypsum Concrete underlayment recommended specifications. Finished floor coverings can be installed when the FIRM-FILL Brand Gypsum Concrete is completely dry. Consult flooring contractor for recommended procedures to test for dryness and acceptable levels of moisture. Reference Hacker Industries, Inc. s Guidelines for Installing Finished Floor Coverings. This guideline is not a warranty and shall be used as a guideline only. See ASTM F2419. Product Data Core Thickness: 1/4 in (6 mm) nominal Roll Weight: 90 lb (40.8 kg) Packaging Length: 30 ft (9.14 m) Core Width: 54 in (137.16 cm) Total square feet: 135 ft² (41.15 m²) Sound Test & UL Fire Rated Designs PURPOSE STATEMENT/DISCLAIMER These guidelines are designed to provide the architectural and building communities with detailed performance data on Hacker Industries, Inc. s comprehensive portfolio of sound attenuation tests and UL Fire Rated Designs. The tests for the assemblies included in these guidelines were conducted in a laboratory setting per ASTM C177, E84, E90, E492 and E2179. These guidelines are not warranties and should be used as guidelines only. The architects and general contractors recommendations supersede these guidelines. Field performance may vary. Subject to express Warranty stated on Hacker Industries, Inc. s website. Hacker Industries, Inc. regularly performs acoustical testing and fire (UL) testing to ensure performance standards for our products. Firm Fill SCM (sound control mats), including Hacker Sound Mat II, were tested acoustically with the following floor assemblies and performed as noted. Hacker Industries, Inc. Architect Binder Hacker Sound Mat II 2017 135

HACKER SOUND MAT II Subfloor Topping Sound Mat 1 (25 mm) 1/4" FIRM- (6 mm) FILL CMD Hacker Gypsum Sound Concrete Mat II Hacker Sound Mat II Corrugated Metal Deck Subfloor Insulation Truss Ceiling Isolation 14 mm 3-1/2" deep (89 mm) 22 msg unfaced galvanized fiberglass corrugated batt fluting insulation steel decking Contributes points to LEED certification. Dietrich Clark Dietrich RCSD Resilient Channel Ceiling Finish Sound Rating 1 layer 5/8" (16 mm) type C gypsum board 13 mm Quarry Tile Flooring Over 10 mm HSM I** 13 mm Quarry Tile Flooring Over 10 mm HSM I** STC IIC Report # 61 -- 5008041 -- 58 7008100 Steel Deck Steel Joist UL Fire Rated Designs G230, G516, G524, G553, G561, G565, G566, G568, G587, G594, G595 L524, L527, L539, L543, L549, L551, L552, L564, M505, M511, M513, M515, M534 *Tested in accordance with ASTM E2179 - Standard Test Method for Laboratory Measurement of Effectiveness of Floor Coverings in Reducing Impact Sound Transmission Through Concrete Floors. 136 Hacker Industries, Inc. Architect Binder Hacker Sound Mat II 2017

Warranty Subject to express warranty stated on Hacker Industries, Inc. s website. Submittal Approvals Project Name Contractor/Architect Signature Date The sound test acoustical guidelines shall only be a resource and are not a guarantee of performance. FIRM-FILL SCM Underlayments are only one component in an overall floor/ceiling assembly. Their acoustical performance is affected by every other component. The likelihood of achieving code compliance is contingent upon many other trades including (but not limited to) framers, plumbers and drywall contractors. Developers and general contractors are responsible for building properly and testing field performance as soon as possible in order to ensure the reliability of the project. Laboratory tests are not a guarantee of field performance because of the issues noted above and many other design and/or construction errors that may occur. Please consult a professional acoustical consultant to assure specifications are written correctly and that the floor/ceiling assembly can perform to expectations. Field performance testing shall be done to ensure reliability of design prior to occupancy. 2017 Hacker Industries, Inc. FIRM-FILL, GYP-SPAN and the associated logos are the registered trademarks of Hacker Industries, Inc. PRODUCT INFORMATION See www.hackerindustries.com for current recommended product specifications and literature. Hacker Sound Mat II, for use with Hacker Floor Underlayments, is a component in an overall floor/ceiling assembly. Its performance is affected by every other component and the likelihood of achieving code compliance is contingent upon many other trades, including framers, plumbers and drywall contractors. Developers and general contractors are responsible for building properly and testing field performance as soon as possible in order to ensure the reliability of the project. WARNING Laboratory tests are not a guarantee of field performance because of the issues noted above and many other design and/or construction errors that may occur. Please consult a professional acoustical consultant to ensure plans are proper and that the floor/ceiling assembly can perform to expectations. TRADEMARKS FIRM-FILL, GYP-SPAN, Let Our Products Floor You and the associated logos are trademarks of Hacker Industries, Inc. LEED is a registered trademark of the U.S. Green Building Council. WARRANTY HACKER INDUSTRIES, INC. SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES, DIRECTLY OR INDIRECTLY SUSTAINED, NOR FOR ANY LOSS CAUSED BY APPLICATION OF THESE GOODS NOT IN ACCORDANCE WITH CURRENT PRINTED INSTRUCTION OR FOR OTHER THAN THE INTENDED USE. HACKER'S LIABILITY IS EXPRESSLY LIMITED TO REPLACEMENT OF DEFECTIVE GOODS. ANY CLAIM SHALL BE DEEMED WAIVED UNLESS MADE IN WRITING TO HACKER INDUSTRIES, INC. WITHIN 30 DAYS FROM DATE IT WAS, OR REASONABLY SHOULD HAVE BEEN, DISCOVERED. SAFETY FIRST Follow good safety/industrial hygiene practices during installation. Wear appropriate personal protective equipment. Read specs, MSDS and literature prior to specification and installation. 2017 Hacker Industries, Inc., Newport Beach, CA. Hacker Industries, Inc. Architect Binder Hacker Sound Mat II 2017 137