Preliminary Hazard Analysis and Risk Assessment for the Wood Centre Development, Southwood Resources - Huon

Similar documents
LIQUEFIED NATURAL GAS FACILITY REGULATION 146/2014

WOOD PELLETS- A GROWING MARKETPLACE

Gas Suspension Absorber

Chapter 10. Flowsheet Analysis for Pollution Prevention. by Kirsten Sinclair Rosselot and David T. Allen

Appendix 4.2 Furnace Start Up and Shut Down Procedures

Potential Environmental Impact of Operating Facilities

OELG Event Categories

Post Combustion CO 2 Capture Scale Up Study

Cleaner Production and Energy Efficiency in Industry. With Focus on the Electricity Supply

COAL - HAZOP SYSTEMS ANALYSIS GRINDING AND FIRING

MOLTEN MATERIALS MANAGEMENT STANDARD. AA_AFRS_ doc APPROVED May 2008 Page 1 of 6

Eurobitume UK. Site Inspection for Delivery of Bitumen

Steam balance optimisation strategies

For Condensing Economizers ENBRIDGE MAY Topics

HEALTH AND SAFETY MANUAL

JBS Pollution Incident Response Management Plan

DAVID BRENNAN SUSTAINABLE PROCESS ENGINEERING CONCEPTS, STRATEGIES, EVALUATION, AND IMPLEMENTATION. Pan Stanford. Publishing

Basic Environment,Health & Safety Guidelines for Foundries

2. TECHNICAL DESCRIPTION OF THE PROJECT

Risk Analysis of a Chlorine Handling Facility

Assessment of Operation and Catastrophic Risks of Transport Gasifier Pilot Plant

Lecture (6) on. Schematic of a Thermal Power Plant. By Dr. Emad M. Saad. Mechanical Engineering Dept. Faculty of Engineering.

12.0 Predicted Environmental - Impact & Mitigation measures

FEEDLOT DESIGN AND CONSTRUCTION. 39. Agricultural and veterinary chemical storage. AUTHORS: Orla Keane and Peter Watts

FOR GOOD RTO OPERATION, KNOW YOUR INPUTS

NEW TECHNOLOGIES IN COAL-FIRED THERMAL POWER PLANTS FOR MORE EFFECTIVE WORK WITH LESS POLLUTION

Papua New Guinea LNG Project. Environmental and Social Management Plan Appendix 6: Spill Prevention and Response Plan PGGP-EH-SPENV

VIRIDOR WASTE MANAGEMENT ARDLEY EFW PLANT EP APPLICATION - NON TECHNICAL SUMMARY

TO INTERESTED PARTIES: RE: Chippewa Valley Ethanol Company Expansion

POWER PLANT- BOILER OPERATIONS SIMULATOR

Biomass Boiler Emission Abatement Technologies. Simon Wakefield

PROCESS OPERATIONS. Introduction to Operations. Diagrams for the Operating Unit. Revised 11/30/18 1

Greater Vancouver Regional District Concrete and Concrete Products Industries Emission Regulation Bylaw No. 1084, 2008

CRYOGENIC SOLVENT ABATEMENT (VOC s )

COLLECTION AND INCINERATION OF HIGH VOLUME-LOW CONCENTRATION PULP MILL NONCONDENSIBLE GASES

Boiler Efficiency Testing. To understand the operation of a fire tube boiler To determine the operating efficiency of the boiler

Cleaner Production Self Assessment Guide Metal Finishing Industries

Valmet Online Learning

2.2 The Purposes and Advantages of a Central Utility Plant

COURSE TITLE : POWER PLANT INSTRUMENTATION COURSE CODE : 5215 COURSE CATEGORY : E PERIODS/WEEK : 4 PERIODS/SEMESTER: 52 CREDITS : 4

Sulcor Pollution Incident Response Management Plan (PIRMP)

25fh DOE/NRC NUCLEAR AIR CLEANING AND TREATMENT CONFERENCE

THE COMPLETE GUIDE TO ISO14001

Process Hazard Analysis Fundamentals. Walt Frank, P.E. Frank Risk Solutions F R A N K R I S K S O L U T I O N S

Technical Guidance Note (Monitoring) Medium Combustion Plant Directive and Generator Controls: monitoring point source emissions

Pollution Incident Response Management Plan

Unilib Manufacturer. Chemical Handling, Storage and Disposal Checklist. conducted for. Date and Time of Inspection 14 May :41 PM

ROP - CAM EXAMPLE TABLE NOTE: THIS TEMPLATE IS NOT AN OUTLINE FOR A CAM PLAN

CANDU Safety #14 - Loss of Heat Sink Dr. V.G. Snell Director Safety & Licensing

Energy Production Systems Engineering

San Joaquin Valley Unified Air Pollution Control District Best Performance Standard (BPS) x.x.xx

DP Specialist Anti - Corrosion. Boiler. Clean energy, natural solutions

Process Safety Management (PSM)

TABLE OF CONTENTS 8.0 HEALTH & SAFETY PREVENTION AND HANDLING OF FIRES MAINTENANCE OF EQUIPMENT CONTINGENCY MEASURES 8-2

Borregaard Case Study. Sarpsborg I & II

Cooling tower efficiency U2 Eco-efficiency resources for the food processing industry

PTAC PROCESS TECHNOLOGY II - SYSTEMS. Last Reviewed: Page 1 of 10

CORE TOPICS Core topic 3: Identifying human failures. Introduction

CHAPTER 2 STUDY OF 210 MW BOILER SYSTEM 2.1 DESCRIPTION OF 210 MW BOILER

WHEN ALL THE DUCKS LINE UP: CASE STUDIES ON HITS AND VERY NEAR MISSES. Leanne Wells. Department of Health

APPLICABILITY. (1) Except as provided in Section (b), this rule is applicable to all vapor degreasing operations.

The Needs of Process Safety Management in Palm Oil Industry

INVESTIGATION OF THE BUILDING LIQUID EFFLUENT PIPE WORK AS PART OF THE AGEING MANAGEMENT AT SAFARI-1

12. Environmental management

Wood Products Energy Savings Guide

Safety Practices in Chemical and Nuclear Industries

Green Marine. Environmental Program. Performance Indicators for Ship owners

Valmet innovations in use at the Äänekoski bioproduct mill

Control of sulfidity in a modern kraft pulp mill

HUMAN ERROR ANALYSIS AT A REFINERY

WHS Management Plans

COMPARISON OF PROCESS HAZARD ANALYSIS (PHA) METHODS

Instruction Manual C20

EPA Report on the investigation of the Lime spill incident which occurred at the Dublin Waste to Energy Facility, Poolbeg on 7 th June 2017.

A BRIEF LOOK AT BACKFLOW PREVENTION AND CROSS-CONNECTION CONTROL LES O BRIEN

T-125 EVOLUTION OF THERMAL REMEDIATION. Technical Paper T-125. EVOLUTION OF THERMAL REMEDIATION by Wendell R. Feltman P.E.

Taravosh Jam Design & Engineering Co.

1.01 Development of the Air cross flow gasification-process

CHAPTER 1 INTRODUCTION

Job Hazard Analysis (JHA)

APPLIED SCIENCE. Unit 16 Waste management Suite. Cambridge TECHNICALS LEVEL 3. R/507/6163 Guided learning hours: 60. ocr.org.

Palmerston North City Council Policy

Environment Incident Identification & Response (Mining Areas)

National Occupational Standards for Processing Operations: Hydrocarbons. November 2006

CHAPTER 9. Emergency Response. Chapter 9. National Pesticide Applicator Certification Core Manual

INTERNATIONAL CYANIDE MANAGEMENT INSTITUTE. Cyanide Production Summary Audit Report (Repackaging & Storage) Vehrad Transport & Haulage Tema, Ghana

Draft Quantification Protocol for Landfill Gas Capture and Combustion Carbon Competitiveness Incentive Regulation

WASTE TYRE RECYCLING PLANT

Nuclear Safety, Culture and Behaviours Nuclear Supply Chain Event 28 th April Mark Edmiston Head of EHSS&Q

ENERGY EFFICIENCY AND EMISSION REDUCTION OF TPM, PM 2.5, AND SO 2 FROM NATURAL GAS AND FUEL OIL FIRED BOILER EXHAUSTS

RISK ASSESSMENT FOR FURNACE OIL STORAGE TANK:

Copper Cliff Smelter Complex

OPTIMISATION OF ANGLO PLATINUM S ACP ACID PLANT CATALYTIC CONVERTER. M. K. SICHONE Anglo Platinum, ACP, Kroondal, South Africa

Your partner for the right solution

INDUSTRIAL USER WASTEWATER DISCHARGE PERMIT APPLICATION FORM

ASA Bloomingburg, LLC. Air permit-to-install (PTI) number Public Hearing Date April 18, 2006 Comment Period End Date April 25, 2006

Lessons Learned from PSM Audits

Process Hazard Analysis Human Factors Checklist

State of the Art (SOTA) Manual for Stationary Gas Turbines

White Paper: How to prevent silo over-pressurisation and over-filling

Transcription:

Preliminary Hazard Analysis and Risk Assessment for the Wood Centre Development, Southwood Resources - Huon

TABLE OF CONTENTS PRELIMINARY HAZARD ANALYSIS AND RISK ASSESSMENT... 4 INTRODUCTION... 4 METHODOLOGY... 4 HAZARD IDENTIFICATION... 4 FUEL STOCKPILE... 4 Hazard ID: Fire Hazard... 4 Action/Recommendation:... 5 BOILER... 5 Hazard ID: No Water Flow... 5 Action/Recommendation:... 5 Hazard ID: Feed Flow Rate Deviation... 5 Action/Recommendation:... 5 Hazard ID: Presence of Contaminants in Feed... 5 Action/Recommendation:... 6 STEAM LINES... 6 Hazard ID: High Pressure Steam Build-up... 6 Action/Recommendation:... 6 TURBINE... 6 Hazard ID: Inadequate Turbine Maintenance... 6 Actions/Recommendation:... 6 COOLING TOWER... 6 Hazard ID: Cooling Tower Non-functional... 7 Actions/Recommendation:... 7 PARTICULATE FILTER SYSTEM... 7 Hazard ID: Blocked Filters... 7 Actions/Recommendations:... 7 Hazard ID: Non-functional Electrostatic Precipitator (ESP)... 7 Actions/Recommendation:... 7 AIR CIRCULATION SYSTEM... 8 Hazard ID: Non-functional Air Circulation System... 8 Actions/Recommendations:... 8 CHEMICAL STORAGE AREA... 8 Hazard ID: Fork Lift Accidents... 8 Action/Recommendation:... 8 Hazard ID: Chemical Accidents... 8 Action/Recommendation:... 9 RISK ASSESSMENT... 9 PRINCIPAL SITE HAZARDS... 9 RERAC SUMMARY...11 Page 2 of 15

CONCLUSION...12 APPENDIX A HAZOPS TEMPLATE GUIDE DIAGRAM...13 APPENDIX B POWER STATION PROCESS FLOW SCHEMATIC...14 APPENDIX C RERAC RANKING SCALES...15 Page 3 of 15

PRELIMINARY HAZARD ANALYSIS AND RISK ASSESSMENT Introduction A preliminary hazard identification and risk assessment was conducted on the power station by SEMF to satisfy the requirements of Section 3.7.6 of the DPEMP guidelines. This condition requires a Preliminary Hazard Analysis to be undertaken on the power station. This study was done in accordance with AS/NZS 4360, 1999 Risk Management Standards. The potential hazards were systematically identified using a preliminary HAZOP study (Appendix A HAZOPS Template), (Perry R.H, 1998) in conjunction with the schematic process flow diagram for the power station (Appendix B Power Station Schematic). These identified hazards are detailed under each specific operational area, together with relevant actions and recommendations on solutions for prevention. To determine whether a quantitative risk assessment is required, the Rapid Environmental Checklist (RERAC), (Jones M.K. 1995) has been selected and adapted in conjunction with Hazard Frequency Tables (Klietz T.A. 1992) as a suitable procedure for providing a preliminary quantitative assessment of the likelihood and severity of a hazardous incident occurring. With this preliminary assessment, accurate judgements can be made on the necessity of a quantitative risk assessment. Methodology The HAZOP study allows systematic identification of potential hazards associated with risks to people, process plants, and the environment. In this study, it has been used to identify hazardous effects caused by deviations in normal process operations. The RERAC Process is primarily used to quantitatively assess hazard scenarios and its associated risks to the environment. In this study, its principal function was to assess the major hazards identified in the previous HAZOP study. A more detailed explanation of the RERAC method can be found in the following Risk Assessment section. Hazard Identification The following section makes use of Appendix A to identify hazards associated with the relevant area/process unit. Recommendations on mitigation measures are also detailed. Fuel Stockpile Hazard ID: Fire Hazard Large amounts of fuel wood are stored for fuel supply to the boiler. The fuel stockpile presents an ideal situation for the propagation of a fire. Page 4 of 15

Action/Recommendation: The appropriate fire hydrants are to be available, to enable containment and reduce the risks of further propagation. Boiler The boiler s primary function is to generate heat by complete combustion of fuel wood with air. This heat is utilised to generate steam from water. The following hazards were identified as having the most significant impact. Other possible deviations, which do not constitute any foreseeable hazards are not mentioned below. Hazard ID: No Water Flow Failure of the feed water pump to the boiler will result in no water flow into the boiler, therefore no heat sink for the combustion process. This will lead to a release of abnormally hot flue gases. This may cause thermal damage to equipment down stream, and ultimately result in release of very hot gases at the stack. Action/Recommendation: Proper control alarms in place will warn of any deviation in temperature, or water flow, and alert operators on cause of malfunction and allow them to shut down the process before the deviation causes damage. Hazard ID: Feed Flow Rate Deviation A deviation in the levels of fuel wood and combustion air will have an effect on the combustion products generated. A defined fuel:air ratio must be complied with, to optimise the combustion process. The effects of deviations such as more fuel wood and/or less air are: incomplete combustion, and a release of larger amounts of particulate matter, undesirable gaseous compounds, including VOC s, noxious gases, and other combustion by-products. These gases are potentially harmful in significant concentrations, and contribute to the greenhouse gas problem. Action/Recommendation: Control systems are to be put in place to monitor and regulate the flow rates of the fuel wood and air, as well as the temperature within the boiler furnace. Any deviation will warn the operators, and immediate corrective action is required. All effluent gas streams are to comply with set DPIWE guidelines for air emissions. Hazard ID: Presence of Contaminants in Feed Contaminants present with the fuel wood, such as off specification fuel wood material, or the boiler water. The latter may occur due to abnormal water treatment or domestic water supply composition. The former will result in abnormal compositions in flue gases, and perhaps will have some effect on the generated heats of combustion. The latter will produce a blowdown stream with an abnormal chemical composition bound for the sewage treatment plant. Provided that the sewage treatment plant is Page 5 of 15

robust enough to handle such deviations, then this incident will pose no further problems. Action/Recommendation: The level of hazard and course of action relating to the abnormal flue gas composition will depend on the types and concentrations of chemicals present. Control systems and continuous monitoring of the quality of the fuel wood going into the boilers will prevent this. Steam Lines Carries live high-pressure steam from the boiler to the turbine. Hazard ID: High Pressure Steam Build-up The event of high-pressure steam build-up, due to blocked lines or throttled valves, may lead to line rupture and pressure loss at the weaker joints. Consequently, this pressure loss will result in decreased turbine efficiency, and venting material may cause electrical and structural damage and pose a hazard to nearby workers. Action/Recommendation: Regularly scheduled maintenance on all piping infrastructures, repair any leaks as soon as possible, and regular structural testing. Turbine Converts the heat energy harnessed from the high pressure steam, to work, and generates electricity. Hazard ID: Inadequate Turbine Maintenance Inadequate maintenance such as failure to properly service the machine, or incorrect installation, will result in physical contact between moving metallic parts within the turbine. This will lead to increased wear, and eventually cause severe internal mechanical damage. There is no foreseeable effect of turbine malfunction on the environment or human life. Actions/Recommendation: A proper and rigorous maintenance procedure should be implemented and complied with, to prevent this event from occurring. Cooling tower Cools and recycles the cooling water used to condense the low-pressure steam from the turbine. Page 6 of 15

Hazard ID: Cooling Tower Non-functional Reduced cooling water flow due to cooling water pump malfunction will result in a less effective condenser, therefore a less efficient turbine, due to the back pressure exerted by uncondensed steam. The reduced amount of steam being condensed will eventually result in a build-up of steam upstream of the condenser, leading to line ruptures. Line ruptures are potentially hazardous to nearby workers, mechanical, and electrical equipment. This hazard has no foreseeable effects on the environment. Actions/Recommendation: Instrumentation measures such as: flow meters installed in the cooling water lines will detect reduced flow; a pressure transmitter in the line upstream of the condenser will indicate any deviation from the set point pressure, and alert operators of the deviation. In the event that the line pressure does increase significantly, pressure relief valves will be present to vent out the extra pressure, and reduce the likelihood of human injury. Particulate filter system Filter out particles produced during combustion in two stages: a coarse filtration, followed by a fine filtration stage. Hazard ID: Blocked Filters Backlog of hot flue gases, due to the blocked lines, will cause an increased resistance at the induced draft fan, resulting in limited out flow of gas. The rate of combustion in the boiler will be affected, and incomplete combustion will occur, due to the lack of oxygen feed. This will result in more coarse size particulates being generated, as well as CO, NO x, and other combustion by-products. The effluent gases produced will be released into the atmosphere, and are potentially hazardous to human life and the surrounding environment. Actions/Recommendations: Control systems in place will impose a decrease in the conveyor speed, therefore less fuel wood in, to accommodate the reduced oxygen entering. Temperature, oxygen, and CO alarms will alert the operators of the deviation, and will require their immediate attention, because if left unattended, will lead to complete shutdown. Compliance to a regular maintenance schedule will prevent this from occurring. Hazard ID: Non-functional Electrostatic Precipitator (ESP) Fine dust particles will not be removed from the flue gas stream, therefore the fines will go out through the stack. Actions/Recommendation: An air emission monitor, which measures the level of particulates present in the flue gas, is located in the stack. Above a certain particulate level, an alarm will alert Page 7 of 15

operators of the deviation, in which the operators will be required to alter the feed and boiler conditions to reduce the amount of particles generated in the combustion process, or to carry out corrective action to remedy this problem. Air Circulation System The air circulation system comprises of two fans, the induced draft fan, and the combustion air fan. The induced draft fan draws combustion air generated in the boiler, and discharges it out through the stack. The combustion air fan pushes air into the boiler, and provides the air required for combustion. These two fans function to generate a more efficient air flow both into and out of the boiler. Hazard ID: Non-functional Air Circulation System Failure of one or both of the fans will lead to reduced air flow through the system. The rate of combustion in the boiler will be affected, and incomplete combustion will occur, due to the lack of oxygen feed. This will result in more coarse size particulates being generated, as well as CO, NO x, and other combustion by-products. The effluent gases produced will be released into the atmosphere, and are potentially hazardous to human life and the surrounding environment. Actions/Recommendations: Control systems in place will impose a decrease in the conveyor speed, therefore less fuel wood in, to accommodate the reduced air flow. Temperature, oxygen, and CO alarms will alert the operators of the deviation, and will require their immediate attention, because if left unattended, will lead to complete shutdown. Compliance to a regular maintenance schedule will prevent this from occurring. Chemical Storage Area The chemical storage area stores chemicals used for water treatment. Hazard ID: Fork Lift Accidents Fork lift operator while transferring storage containers, pierces one of the containment units, pumps, or lines, resulting in loss of containment of the chemicals. The hazard depends on the nature of the chemicals spilled. Action/Recommendation: Protective bunding should be present on all sensitive equipment in the storage area, and the appropriate chemical spill kits should be readily available if the incident does occur. Hazard ID: Chemical Accidents The hazardous nature of the chemicals impose a risk in themselves, in case of spillage, misuse, or a fire. Page 8 of 15

Action/Recommendation: Entry into the storage area should be limited to trained personnel, wearing the appropriate personal protective equipment (PPE). Appropriate chemical spill kits should be readily available in case of accidents. Safety shower, eye-wash, and first aid facilities should be available in case of emergency. Material and Safety Data Sheets (MSDS) should be available for emergency personnel in an accident situation. Risk Assessment The preceding Hazard Identification section is used for this Risk Assessment section to focus on the most critical hazards present within the power plant site. The Rapid Environmental Risk Assessment Checklist (RERAC) methodology has been used to quantify the likelihood and severity of an incident or hazard. These result in a ranking of each hazard in terms of total assessed risk (TAS). Events that are ranked the greatest TAS should be given the highest priority in terms of preventative action (Appendix C RERAC Ranking Scales). Total Assessed Risk (TAS) = Likelihood x Severity The acceptability of the hazards can then be decided for the particular activity depending on which of the three following categories they fall in. Table 1 Hazard Categories CATEGORY DESCRIPTION TAS Category One Immediate action required to reduce TAS to 9 or below. >14 Category Two Medium term action required to reduce TAS to 9 or below. 9-14 Category Three Action depends on company policy and resources. Long term target should be for all TAS scores to be <5. <9 Principal Site Hazards As mentioned above, the HAZOPS report has assisted in identifying the following areas as having the potential to kill, injure, or cause significant engineering and environmental damage, resulting from abnormal operating conditions or accident based activities: Fuel stockpile Boiler Steam Lines Turbine Cooling Tower Particulate Filter System Air Circulation System Page 9 of 15

Chemical Storage Each of these identified areas have been assessed under the RERAC method. The following table details the Hazard Category Summary for the areas identified above. Hazard activities previously identified in the Hazard Identification section, which has a TAS ranking of <4 have not been included in this table because these hazards are deemed to be of significant consequence. Table 2 Hazard Category Summary for selected critical areas within the Southwood Power Plant Category One Hazards (TAS>14) Activity L S TAS Consequence Preventative Action NIL 0 0 0 NIL NIL Category Two Hazards (9<TAS<14) Activity L S TAS Consequence Preventative Action NIL 0 0 0 NIL NIL Category Three Hazards (4<TAS<8) Activity L S TAS Consequence Preventative Action High pressure steam build-up Fuel feed flow rate deviation Non-functional air circulation system 4 2 8 Line rupture, venting material may cause electrical and structural damage, and injure nearby workers. 3 2 6 Incomplete combustion resulting in the generation of undesirable gaseous compounds such as CO, and increased levels of particulate matter. 3 2 6 Incomplete combustion will occur, resulting in coarse size particulates generated, as well as CO, NO x, and other combustion byproducts. Regularly scheduled maintenance on all piping infrastructure, and structural testing. Continuous monitoring of feed flow rates, as well as CO levels leaving through the stack. Temperature, oxygen, and CO alarms will alert the operators of the deviation. Compliance to a regular maintenance schedule will prevent this from occurring. Non-functional 3 2 6 Build-up of low Recommendations Page 10 of 15

cooling tower pressure steam due to little or no condensation activity leading to line ruptures. detailed in the HAZOP section should be implemented. Boiler water feed pump failure 2 2 4 No water flow into the boiler, resulting in release of abnormally hot flue gases. This may cause thermal damage to equipment down stream, and result in release of very hot gases at the stack. There will be a back-up pump. Switchover is automatic. Proper control alarms in place will warn of any deviation in temperature, or water flow, alert operators, and allow them to shut down the process before the deviation causes damage. Inoperative ESP 2 2 4 Fine dust particles will be released with the effluent gas, through the stack. An air emission monitor will alert the operators, should the particulate level rise beyond the set point level required by EPA guidelines. Inadequate Turbine Maintenance Fork lift accidents at the chemical storage area 1 4 4 Accelerated wear of turbine components, eventually leading to lower power generation and ultimately, to severe internal mechanical damage. 2 2 4 Loss of containment of boiler water treatment chemicals due to rupture of tanks or pipes. A proper and rigorous maintenance procedure will be implemented and complied to. Appropriate bunding and protection on all sensitive equipment in the storage area. Chemical spill kits readily available in immediate vicinity. RERAC Summary Hazard actions and recommendations have been defined in the Hazard Identification and RERAC sections of this report to reduce the frequency, and in most instances, the severity of a hazard event. As detailed in Table 2, there were no Category One or Category Two hazards identified. The vast majority of all RERAC assessments fell under a TAS ranking of 5, the recommended level for industry operations. Category Three hazards are deemed minor, and company policy should dictate that a long term goal be set to reduce the TAS scores to below 5. The most significant of Page 11 of 15

these Category Three hazard is the hazard associated with the rupture of lines containing high pressure steam. Line ruptures pose a direct hazard to operators and electrical equipment. Implementation of the recommended control measures will significantly reduce the likelihood and severity of this event. There are no direct environmental effects associated with this hazard. This preliminary RERAC study has not identified any catastrophic environmental hazard event scenarios. Conclusion Based upon the HAZOP and RERAC studies, it is concluded that if the actions and recommendations outlined in this report are acted upon, then there is little risk associated with hazards that have significant environmental consequences. Page 12 of 15

Appendix A HAZOPS Template Guide Diagram Guideword Meaning Example of Deviation ID Hazard Comment Action No flow in pipe, no reactant No (Not or None) The activity is not carried out charged to process, batch not or ceases. cooled, check omitted. More Of Less Of More Than or As Well As Part Of A quantitative increase in an activity. A quantitative decrease in an activity. A further activity occurs in addition to the original activity. The incomplete performance of an activity. More (higher, longer) quantity flow, temp, pressure, batch, concentration, time. Less (lower, shorter) of above. Impurities present, extra phase (solid or gas in liquid phase), extra (unplanned) process operation. Reduced strength, missing component, operation only partcompleted. Reverse Inversion of an activity. Back flow or back pressure, heat rather than cool. Sooner/Later Than Other (Than) An activity occurring at the wrong time relative to other activities. Complete substitution of an activity, no part of the intention is achieved. The activity occurs at the wrong time. Wrong material charged, nonroutine conditions, start up, shut down, maintenance, cleaning, etc. failure of services. Page 13 of 15

Appendix B Power Station Process Flow Schematic (Insert diagram here)

Appendix C RERAC Ranking Scales In the RERAC method, the following ranking scales are used: Likelihood Score (Frequency of Possible Cause) Event Probability Frequent Event (25 times per year) Probable Event (5 times per year) Occasional Event (1 time per year) Remote Possibility (1 time per 5 years) Improbable Event (1 time per 25 years) Score 5 4 3 2 1 Severity Score Real Hazard Index Severity Description Score Critical Major Significant Marginal Negligible Major long-term engineering & environmental impacts and/or damage usually resulting in fatalities, multiple injury victims and/or highly visible to the public. Major short-term engineering & environmental impacts and/or significant human injury or injuries potentially fatal. Minor short-term engineering & environmental impact and/or short-term human injuries and/or low public visibility. Marginal short-term engineering & environmental damage and/or minor human injuries. No measurable effect on the engineering or environmental condition on site, no effect on workforce, not visible to the public. 5 4 3 2 1