Sectional Facilities. Central Materials Characterization Facility (CMCF)

Similar documents
Lab. Analytical Services

Analytical Services REV D

Primary Standards for Temperature Calibration

Introduction. From the combination of TG and DTA or HDSC one receives a broad range of information, such as:

T H E R M A L A N A L Y S I S

MATERIAL CHEMISTRY RESEARCH LABORATORY Department of Chemistry, University of Dhaka

Bohlin. Rheological instruments backed with rheological experience. Rheological properties

DIL 402 CD Double/Differential Dilatometer

高溫黏度計 HIGH TEMPERATURE VISCOMETER

Additive Manufacturing. Characterization of powder-bed based manufacturing

PURALOX /CATALOX High purity activated aluminas

Effect of Flocculation of Alumina Slip on the Pore Size Distribution of Cast Alumina by Polyacrylamide (PAM)

Simultaneous Oxygen, Nitrogen and Hydrogen Determination of Metals. Dennis Lawrenz, John Hawkins

Price List. Calibration Fee

Burning and Explosion Properties of Metallic Nano Powders

Dilatometer L 76 L 75 Horizontal L 75 Vertical

Advanced Energy Storage Technologies. Lithium-Ion Battery Series

Optimizing rheology for paint and coating applications

Methane oxidation over A-site ordered and disordered Sr 0.8 Gd 0.2 CoO 3- perovskites

Controlled Nanoporosity of Organic Aerogels by Dispersing Clay Platelets

Supplementary Electronic Information for:

Particle Size Determination of Porous Powders Using the SediGraph

PIM Technology. a powder technology for complex small engineering parts

AUTOPORE V. Mercury Intrusion Porosimetry

Testing for Rotational Moulding (RM) and Service Capabilities of BITS

Synthesis of Nanostructured Silicon Carbide Spheres from Mesoporous C-SiO 2 Nanocomposites

MIXTOOL SR 600 / SD 605 Machinable tooling paste

G8 GALILEO. Innovation with Integrity. High-End Melt-extraction Analyzer. Inert Gas Method

Slurry concentration [Vol.%]

CALCINATION AS ADDITIONAL UNIT OPERATION IN THE PELLETIZING OF IRON ORES PRESENTING HIGH CONTENTS OF LOSS ON IGNITION

Improved technology for manufacture of carbon electrodes

Differential Scanning Calorimetry DSC 404 F1

In situ, Non-contact monitoring of Powder Compacts during Polymer Removal

EXPLORING POWDER INJECTION MOLDING OF NIOBIUM

Surface Layer Characterization of Atomized Magnesium for use in Powder Metallurgy Products Paul Burke and Georges J. Kipouros

Supporting Information

DILATOMETER Special Software

REALIZATION OF THE FREEZING POINTS OF INDIUM, TIN AND ZINC USING STAINLESS STEEL CASED CELLS

Material Data for Moldex3D Simulation. Jeff Chen Account Manager EMEA

CHAPTER 5 GROWTH OF POTASSIUM TETRA BORATE (K 2 B 4 O 11 H 8 ) SINGLE CRYSTALS BY LOW TEMPERATURE SOLUTION GROWTH METHOD AND ITS CHARACTERISATION

Technical Information. to the. Constant Torque Gieseler Plastometer PF-22

Pilot processing line for manufacturing articles from bulk nanostructured ceramics/composites

Rheometer RHEOTEST RN 4.1 For Quality Control and R&D

Structural Characterization of Nano-porous Materials

Supplementary Figure 1 Optical properties of the DLS. (a) The transmittance of water and

1/31/ Plastics Processing. Thermoplastics (Tampere)

Construction of a Low Temperature Heat Exchanger Cell

Powder Rheology. Powder Flow Measurement with MCR Rheometers

Thermometry laboratory

By *T.Khalil, **J. Bossert,***A.H.Ashor and *F. Abou EL-Nour

Our Family of Products

New Energy Research Institute at South China University of Technology

Bruker JUWE G8 GALILEO ONH. High-End Melt-extraction Analyzer. Elemental Analysis. think forward

THERMAL DIFFUSIVITY THERMAL CONDUCTIVITY

Thermo Scientific ARL EQUINOX 100. X-ray Diffractometers

KATEDRA MATERIÁLOVÉHO INŽENÝRSTVÍ A CHEMIE. 123MAEN basic materials properties

Differential Scanning Calorimetry DSC 404 F3

Thermometry, Chinese TAIPEI, CMS (Center for Measurement Standards)

A high tenacity electrode by assembly of a soft sorbent and. hard skeleton for lithium-sulfur batteries

Glass foams from cathode ray tubes

Heat Transfer in Polymers

DSC limit of detection: < 0.1 µw (depending upon the sensor) System time constant: 0.6 s to 3 s (depending upon the sensor)

Solvent-free facile synthesis of di-octyl phthalate over heterogeneous sulfated zirconia acid catalyst

i Series Thermal Analysis Systems

CSIR-National Chemical Laboratory. Analytical/Testing Charges. Table of contents

Candle Soot as Supercapacitor Electrode Material

D. Ehrt*, H. T. Vu, A. Herrmann and G. Völksch

Experimental Study and Computer Modeling of the Triple Point of Argon System

Comparison of coal reactivityduring conversion into different oxidizing medium

Large-scale Spinning of Silver Nanofibers as Flexible and. Reliable Conductors

Canadian Council of Independent Laboratories Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) AASHTO T315-09

Supporting Information to Carbon Nanodots Towards a Comprehensive Understanding of their Photoluminescence

Accupyc II. gas displacement pycnometry system

Realization of ITS-90 from K through K: One Company s Approach

TGA Calibrations, Adjustments & Maintenance. Queens University Belfast 16/02/12

Analyzing & Testing. Guarded Hot Plate - GHP. Method, Instrumentation, Applications. GHP 456 Titan. Leading Thermal Analysis

Rubber Low Temperature Brittleness Tester TRBT-A10

CO 2 adsorption using CaO and its potential integration with hydrogen production from biomass gasification

QbD QUANTITATIVE MEASUREMENTS OF CQAS IN SOLID DOSAGE FORM UNIT OPERATIONS

CHAPTER-3 RESULTS AND DISCUSSION

Supporting Information

Bull. Mater. Sci., Vol. 15, No. 5, October 1992, pp ,~C> Printed in India.

High Brilliance Beamline ID02

TriStar II Plus Surface Area and Porosity Analyzer

Analyzing & Testing. Thermogravimetric Analysis TGA. Method, Technique, Applications

Supplementary information. Polymer Derived Silicon Oxycarbide Ceramics as Promising Next Generation Sustainable. Thermoelectrics

7. Experimental. 7.1 Flame retardant treatment

Supporting Information

Electrical and Thermal Properties of Electrically Conductive Adhesives Using A Heat-resistant Epoxy Binder

Guowu Zhan and Hua Chun Zeng*

Electronic Supplementary Information. High Surface Area Sulfur-Doped Microporous Carbons from Inverse Vulcanized Polymers

Current developments in China on the safety of. manufactured nanomaterials

Nitrogen Determination in Soils and Plants by Flash Combustion using Argon as Carrier Gas

Differential Scanning Calorimetry DSC 200 F3

Influence of substrate cooling method on compositional shift and deposition efficiency of HVOF-sprayed WC-Co type coatings

TECHNICAL DATA SHEET

PB 360 GS / DM 05x Green & Sprayable epoxy foam

Constrained Sintering of dielectric and ferrite LTCC tape composites

DEVELOPMENT OF NANO-TUNGSTEN-COPPER POWDER AND PM PROCESSES. 1 Agency for Defense Development Yuseong, P.O.Box 35-5, Daejon , Korea

BAM-P126 Material: Flat Membrane

Transcription:

Sectional Facilities Central Materials Characterization Facility (CMCF) Inauguration of CMCF A view of CMCF Total no. of instruments = 17 Operated by trained Engineers and supervised by scientists Maintenance is done by the Members of this section High temperature dilatometers (3 Nos.) Make: Netzsch, Germany Model: DIL 402C Temperature range: Room temperature to 1500ºC Environment: Air, Nitrogen gas and Argon gas Brief description: Dilatometers have the facility of measurement of the thermal expansion coefficient. Softening point and glass transition temperatures of samples can be evaluated through the software. Out of these dilatometers, one can be used for measurement below ambient temperature

Particle size analyzer (Micro range) Make: Microtrac, USA Model: S 3500 Range: 100 nm to 1400 micrometer Brief description: The particle size analyzer uses the TRI-LASER Diffraction System developed by Microtrac which allows light scattering measurements to be made from the forward low angle region to almost the entire angular spectrum (approximately zero to 160 degrees). It does so by a combination of three lasers and two detector arrays, all in fixed positions. The resultant scattered light information from all three lasers is combined to generate particle size distributions with good resolution Glass viscometer Make: Bahr, Germany Model: VIS 403 Temperature range: up to 1500ºC Viscosity range: up to 3.5 dpas Brief description: The glass viscometer is a rotating cylinder type viscometer and is used for measuring viscosity of glass samples (up to 3.5 dpas

Carbon Determinator Make: LECO, USA Model: C600 Range: 0.6 ppm to 6% of 1 gm sample Brief description: The carbon analyzer can analyze the carbon content of samples(both high & low carbon content). Surface area analyzer (2 nos.) Make: Quantachrome USA Model: NOVA 4000e Range: Lower limit: 0.05 m 2 /g Brief description: The Surface area analyzer is used to measure the surface area of samples using multipoint or single point BET method, porosity by gas adsorption, total pore volume, pore size distribution (mesopores) using BJH method and external surface area or statistical thickness surface area

Gas Pycnometer Make: Micromeritics, USA Model: Accu Pyc 1340 Description: Helium gas is used for measurement of volume as well as density of sample. Sample requirement: Minimum sample volume required 35 Cm³ to 100 Cm³ in any shape. GCMS Make: Thermo fisher, USA Model: DSQ230 LT Description: Gas/volatile type of sample used in make DSQ230 LT, GCMS application for identification and quantification. Liquid and solid type of sample can be used for direct insertion probe in GCMS. Fragment mass measurement can be done up-to 1050 a.m.u in M.S. Sample requirement: Sample should be clean and minimum requirement is 2ml.

Simultaneous DTA-TGA/DSC-TGA (2 nos.) Make: Netzsch, Germany Model: STA 409C & STA 449C Temperature range: Room temperature to 1750ºC & 1600ºC Environment: Air, Nitrogen gas and Argon gas Brief description: The STAs (Simultaneous thermal analyzers) have the facility of measurement of DTA/TGA & DSC-TGA of samples. Important characteristic temperatures of samples viz, Glass transition temperature, melting temperature and phase transition temperatures can be evaluated through the software Rheometer Make: Malvern, USA Model: BOHLIN Gemini Range: Continuous torque control from 3nNm to 200mNm Brief description: The Rheometer is used to measure the rheological properties of various types of samples such as gels, pastes and other viscous substances

Thermocouple calibration setup Standards used: (i)s type thermocouple (Uncertainty 0.7ºC) (ii) SPRT (25Ω), (iii) Voltmeter, (iv) Thermocouple calibration furnace, (v)cold bath with Triple Point of Water (TPW) standard Brief description: The thermocouple calibration facility is used to calibrate both base metal and noble metal T/Cs by comparing with standard thermocouple. The range of calibration is 1000ºC which can be extrapolated up to 1400ºC. The calibration is done following the guidelines of ASTM E220 Nano particle size analysis, zeta potential and isoelectric point determination: Make: Malvern, USA Model: ZEN 3600 Particle size range: 0.6 nm to 6 micrometer Brief description: The Zetasizer has the facility of measurement of zeta potential and particle size (0.6 nm to 6 µm)of dispersed samples.

Mercury Porosimeter & Pore size distribution determination (2 nos.) Make: Quantachrome, USA Model: Pore Master Pore size range: 3.5 Angstrom to 800 micrometer Brief description: The Mercury Intrusion Porosimeter is used to measure the pore size distribution of samples (3.5Å to 800µm).Other properties that can be evaluated are Surface area from intrusion curves, porosity, pore tortuosity, permeability, throat/pore ratio, fractal dimension and compressibility of samples Nitrogen & Oxygen Determinator Make: LECO, USA. Model: TC600. Range: 0.05 p.p.m to 3 % of 1 gm of sample. Brief description: The nitrogen analyzer can analyze the nitrogen content in sample. Sample requirement: 5 gms of solid or granular sample is required