ANSUL JET-X High-Expansion Foam Generators

Similar documents
HIEX High-Expansion Foam Generators

HIEX High-Expansion Foam Generators

WATER POWERED HIGH EXPANSION FOAM GENERATORS

High Expansion Foam Generators Model HIEX

Foam Systems. a p p l i c a t i o n s : F oam Sy s t e m s

BLADDER TANKS HORIZONTAL & VERTICAL HARDWARE

BLADDER TANKS HORIZONTAL & VERTICAL hardware

Sprinkler Identification Numbers (SINs)

TECHNICAL DATA 90 AND 180 GRATE NOZZLE MODEL GN PRODUCT DESCRIPTION

TECHNICAL DATA 360 GRATE NOZZLE MODEL GN PRODUCT DESCRIPTION

90 and 180 Grate nozzle

Design Criteria, CPVC Pipe

3. Technical data. Grate nozzles Model GN , 180, and 90. Page 1 of Construction Features

a difficult challenge when trying to achieve effective coverage within a shallow space. The Model CC1 Combustible

40.09 V25, K4.2 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS SPECIFIC APPLICATION V2502 UPRIGHT QUICK RESPONSE

Foam Concentrates and Hardware

Foam ratio controller model vrc

COIN QR UPRIGHT FUSIBLE ELEMENT SPRINKLER VK901 (SPECIFIC APPLICATION) TECHNICAL DATA

TECHNICAL DATA OBSOLETE

NDP-50 Specifications

NDP-40 Specifications

1511 Series. Consolidated * Valves. Safety Valve

Husky 716 Aluminum. Please Contact Us With Any Questions

YORK BULKHEAD MOUNTED CHILLED BEAMS ENGINEERING GUIDE

COIN QUICK RESPONSE UPRIGHT SPRINKLER VK900 (SPECIFIC APPLICATION) TECHNICAL DATA

Foam Concentrates and Hardware

SPECIFIC APPLICATION MODEL "IC" INTERSTITIAL COMBUSTIBLE CONCEALED SPACE UPRIGHT SPRINKLER GL5608

TECHNICAL DATA COIN QUICK RESPONSE UPRIGHT SPRINKLER VK950 (SPECIFIC APPLICATION)

SPECIFIC APPLICATION ATTIC SPRINKLERS

SPECIFIC APPLICATION MODEL "IC" INTERSTITIAL COMBUSTIBLE CONCEALED SPACE UPRIGHT SPRINKLER GL5608

Flammable Liquid Fire Solutions

Standard and Low-Flow 100 PLUS Powder Feed Pumps

MICROFAST COIN TM QUICK RESPONSE UPRIGHT SPRINKLER SIN VK900 (SPECIFIC APPLICATION) TECHNICAL DATA

Design Criteria, CPVC Pipe

YORK PASSIVE CHILLED BEAMS ENGINEERING GUIDE

MIGHTY THERM CP. Powerful, Efficient, Low Nox. Reliable and. Economical. Gas Fired Commercial Pool Heating Boiler. Heating Systems Company

NOTICE OF DISCONTINUATION,

B. Provide equipment complying with this specification and manufactured by one of the following:

SPECIFIC APPLICATION ATTIC SPRINKLERS

SPECIFIC APPLICATION ATTIC SPRINKLERS

Extended Coverage Sprinklers

CFFWA-20-1-U Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 60,000 BTUH

GUC LNG Facility Phase IIB Expansion 6/20/14 INSTRUMENTATION SPECIFICATION. A. This Section includes instrumentation for process piping systems.

Fiberglass Cooling Towers

DANGEROUS GOODS PETRO INDUSTRIAL TANK COMPLIANCE CHECKLIST FORM

A REVOLUTION IN PUMPING EFFICIENCY INTRODUCING THE NEW ALL-FLO PUMP. SIMPLE A simple leak free bolted design ensures quick and easy repairs EFFICIENCY

Solid stream nozzles. Cleaning High pressure cleaning Jet cutting Recycling of liquids and many others...

3. technical data. Page 1 of 10

The Culligan Hi-Flo 50 Series Industrial Water Filter System

AIR OPERATED DOUBLE DIAPHRAGM PUMPS

Sentinel LNG. Panametrics Ultrasonic Flowmeter for Cryogenic Liquids. GE Sensing & Inspection Technologies. Benefits. Applications

Fire Protection Underground Piping. ASCE Meeting 12/17/14 Columbia, SC

C O R R O S I O N R E S I S T A N T P I P E S U P P O R T S Y S T E M

Husky 515 Acetal AOD Pump

DESIGN PACKAGE. COMMONS PARK Twin Falls, Idaho

Solid stream nozzles. Cleaning High pressure cleaning Jet cutting Recycling of liquids and many others...

Lab Scale Bicomponent Extruder Fed Spinning Machine Model LBS

Sentinel LNG. Panametrics Ultrasonic Flowmeter for Cryogenic Liquids. GE Sensing & Inspection Technologies. Benefits. Applications

PROflex* 60 Hz reverse osmosis machines from 50 to 360 gpm (12-82 m 3 /hr) Water Technologies & Solutions fact sheet.

TECHNICAL DATA. Foam 190a. June 1, 2008

Relays & Volume Boosters

LIQUID-SPECIFIC PRODUCT LINE: ABRASIVE LIQUID PUMPS SERIES DESCRIPTION OPERATING RANGE: IMPROVEMENTS NOMINAL FLOW RATES:

Fine Spray Nozzles GAS COOLING LIGHT MISTING EVAPORATIVE COOLING

PROflex* 60 Hz Reverse Osmosis Machines from 50 to 360 gpm

SANITIZATION SALT CHLORINATION. It s amazing what a little salt can do to enhance your pool experience.

COMMERCIAL WATER SOFTENER LWTF SERIES

Fire Fighting Application

VLM10 In-line Vortex Mass Flow Meter

ANSULITE ALCOHOL RESISTANT CONCENTRATE (ARC) 3% - 6% AFFF CONCENTRATE

Pipe couplings and fittings

Solid Cone Spray Nozzles

Pioneer Forced Draft Cooling Tower Specifications

G2DT Series Performance Data Discharge: 1-1/4 Solids: 1/4. Wholesale Products Page: JP10074SSD-1 Section: Performance Data Dated: January, 2011

DIAGRAM FOR CALCULATING PIPE SIZES, DISCHARGE VELOCITIES AND LOSS OF HEAD IN STANDARD STEEL PIPE PIPE FRICTION LOSS CHART

SECTION A. Product Data: Manufacturer's data sheets on each product to be used, including:

Sewer Jetting Application

SECTION CONCRETE ABOVE GROUND FUEL STORAGE

P630 HIGH FLOW GAS REGULATOR

Husky 307 Polypropylene AOD Pump

W ARR A NTY FAIRBANKS NIJHUIS 1600 SERIES SINGLE STAGE END SUCTION PUMPS. Certified to NSF/ANSI 372.

AMMONIA REFRIGERATION GAUGES

Certificate of Compliance. Automatic Control Mode Sprinklers for Fire Protection

NT FR 200 FRAME SAW. 102 Walnut Street Borden, IN (812) Fax (812)

SECTION [ ] MANUFACTURED METAL BOLLARDS

See pages 2, 7 and 8 for ATEX ratings. AIR VALVE No-lube, no-stall design 30(51) 35(59.5) U.S. Gallons per minute

Price Book - Section 7 Nozzles and Sprinkler Accessories

G2S. Vertical Sump Pump

Spray Booth Guideline

G2D Series Performance Data Discharge: 1-1/4 Solids: 1/4. Wholesale Products Page: JP10075SSD-1 Section: Performance Data Dated: January, 2011

Nettco S-Series Mixer SANITARY STAINLESS STEEL - PORTABLE/FIXED MOUNT MIXERS

LNG Terminal Equipment. Juan Manuel Martín Ordax

2/2 % ) Direct Acting Subminiature Solenoid Valves. 1/8" and 1/4" NPT. Features. Construction. Electrical

Pioneer Forced Draft Cooling Tower Specifications

First Revision No. 31-NFPA [ Section No ]

H-25 Series. Up to 20 gpm (75.7/min) H-25 Specialized Designs

ERK Series. features: options: specifications: enclosure. what great systems are built on.

D-1 FIRE PROTECTION PRODUCTS TAPPING VALVE. MUELLER Tapping Valves. MUELLER Tapping Sleeves and Crosses. MUELLER Stainless Steel Tapping Sleeves

SUBMERSIBLE SEWAGE EJECTOR

d n g a n a ck a tio cia lica Filters ctio 3 S ctio n n 3 T ctio 2 S ctio 2 T ctio 1 S d C ctio 1 T d C ria 904L rie e S Ordering Number Description

1.2 DEFINITIONS, REFERENCES, AND OVERALL STANDARDS Follow 07500

Transcription:

DATA SHEET ANSUL JET-X High-Expansion Foam Generats Features n UL Listed and CE Marked n FM Approved models available n LNG specific models available n Water-powered so no electrical power is required n Foam capacities of up to 29,900 cfm (847 cmm) Application ANSUL JET-X High-Expansion Foam Generats are intended f use in total flooding local application high-expansion foam systems. Total flooding high-expansion foam systems are commonly used to protect the following hazards: n Flammable liquid stage areas n Hazardous waste stage areas n Ship holds n Engine rooms Local application foam systems are commonly used to protect aircraft hangars. High-expansion foam systems are also frequently used to protect LNG facilities. These systems are typically used to control the vapization rate of LNG spills reduce the intensity of LNG fires by controlling the rate of vap release. Note: High-expansion foam generats used in LNG applications typically require expansion ratios of approximately 500:1. Description ANSUL JET-X High-Expansion Foam Generats produce large volumes of foam by coating a stainless steel perfated metal screen with high-expansion foam solution and expanding it with airflow generated by a water-powered fan. When used with ANSUL JET-X 2% JET-X 2.75% High-Expansion Foam Concentrates, these generats are capable of producing finished foam with expansion ratios from 450:1 up to 987:1, depending on the model and operating pressure. Approvals and Certifications UL Listed ANSUL High-Expansion Foam Generats are UL Listed f use with either the ANSUL JET-X 2% High-Expansion Foam Concentrate ANSUL JET-X 2.75% High-Expansion Foam Concentrate. FM Approved The JET-X 5A, JET-X 15A, and JET-X 27 models are FM Approved f use with ANSUL JET-X 2% High-Expansion Foam Concentrate. CE Marked All models are CE Marked in confmance with the Machinery Directive 2006/42/EC. Operation and Maintenance Refer to the ANSUL JET-X High-Expansion Foam Generat Operation and Maintenance Manual f detailed procedures on installation, operation, and maintenance. A printed copy of this manual is included with every generat. Foam Generat Components FOAM SCREEN WATER MOTOR BLOWER FAN 001273 Protective Coatings All generat models are painted using a Crosion Resistant Epoxy (Epoxy CR) paint system on the housings, suppts, and guard screens. Fans are painted using a powder paint system to ensure adherence and paint durability. Both paint systems have been subjected to and passed a minimum of 3,000 hours in salt spray crosion testing and are suitable f marine and offshe use. The stainless steel foam screens are not painted to avoid inhibiting foam production. FOAM FOAM SOLUTION SPRAY AIR FLOW FOAM SOLUTION INLET 001274 One Stanton Street / Marinette, WI 54143-2542, USA / +1-715-735-7411 / www.ansul.com Copyright 2017 Tyco Fire Products LP. All rights reserved. / Fm No. F-93137-10

Materials of Construction ANSUL JET-X High-Expansion Foam Generats are manufactured from a combination of carbon steel, stainless steel, and brass components. F materials of construction of the maj components, see the following table: Component Material Model Standard Models: JET-X 2A, JET-X 5A, JET-X 15A, JET-X 20 Standard Models: JET-X 27 LNG Models: JET-X 2A LNG, JET-X 5A LNG, JET-X 15A LNG, JET-X 20 LNG Housing Galvanized Steel Galvanized Steel 316L SS, Pickled and Passivated Foam Screen 201, 302, 304 SS 201, 302, 304 SS 316 316L SS Fan Carbon Steel* Carbon Steel* Carbon Steel* Water Mot Brass Cast Iron/Bronze Brass Nozzle(s) Brass Brass Brass *Carbon Steel fans are powder painted with a durable, marine-grade paint system f crosion resistance. Perfmance Data UL Listed Perfmance (JET-X 2%) Generat Model Part Number UL Listed Orientation Inlet Pressure Flow Rate Foam Output Expansion Ratio psi bar gpm Lpm cfm cmm JET-X 2A Standard 420001 LNG 471066 50 3.4 35 132 2188 62 468 75 5.2 42 159 2727 77 486 100 6.9 50 189 3010 85 450 JET-X 5A Standard 420003 50 3.4 61 231 6658 189 816 75 5.2 75 284 9383 266 939 LNG 436936 100 6.9 87 329 10655 302 916 JET-X 15A Standard 420005 JET-X 15A LNG 472526 40 2.8 108 409 12121 343 840 50 3.4 119 450 14491 410 911 75 5.2 145 549 19141 542 987 100 6.9 169 640 21796 617 965 50 3.4 180 681 12949 367 538 75 5.2 220 833 17769 503 604 100 6.9 260 984 19503 552 561 JET-X 20 Standard 421590 LNG 471871 40 2.8 212 803 13530 383 477 50 3.4 238 901 14746 418 463 75 5.2 294 1113 19007 538 484 100 6.9 338 1279 22598 640 500 JET-X 27 Standard 436899 40 2.8 181 685 20295 575 839 50 3.4 203 768 23965 679 883 75 5.2 243 920 27303 773 840 100 6.9 276 1045 28802 816 781 Notes: 1. JET-X 2% concentrate should not be used f salt water applications. 2. JET-X 2% and JET-X 2.75% concentrates should not be mixed f nmal system operation.

Perfmance Data (Continued) FM Approved Perfmance (JET-X 2%) Generat Model Part Number FM Approved Orientation Inlet Pressure Flow Rate Foam Output Expansion Ratio psi bar gpm Lpm cfm cmm JET-X 5A Standard 420003 LNG 436936 40 2.8 55 208 4020 114 547 50 3.4 62 235 5184 147 625 75 5.2 76 288 7632 216 751 100 6.9 88 333 7794 221 662 JET-X 15A Standard 420005 40 2.8 107 405 9540 270 667 50 3.4 119 450 12150 344 764 75 5.2 149 562 17100 484 861 100 6.9 174 659 19296 546 829 JET-X 27 Standard 436899 40 2.8 184 697 19548 554 795 50 3.4 202 765 21600 612 800 75 5.2 244 924 27036 766 829 100 6.9 280 1060 29916 847 799 Notes: 1. JET-X 2% concentrate should not be used f salt water applications. 2. JET-X 2% and JET-X 2.75% concentrates should not be mixed f nmal system operation. UL Listed Perfmance (JET-X 2.75%) Generat Model Part Number UL Listed Orientation Inlet Pressure Flow Rate Foam Output Expansion Ratio psi bar gpm Lpm cfm cmm JET-X 2A Standard 420001 LNG 471066 50 3.4 35 132 2122 60 454 75 5.2 42 159 2785 79 496 100 6.9 50 189 3163 90 473 JET-X 5A Standard 420003 50 3.4 61 231 5575 158 684 75 5.2 75 284 6628 188 661 LNG 436936 100 6.9 87 329 7182 203 617 JET-X 15A Standard 420005 JET-X 15A LNG 472526 50 3.4 119 450 11269 319 708 75 5.2 145 549 15479 438 799 100 6.9 169 640 18447 522 816 50 3.4 180 681 11735 332 488 75 5.2 220 833 16040 454 545 100 6.9 260 984 19601 555 564 JET-X 20 Standard 421590 LNG 471871 40 2.8 212 803 13443 381 474 50 3.4 238 901 16034 454 504 75 5.2 294 1113 21145 599 538 100 6.9 338 1279 24301 688 538 Note: JET-X 2% and JET-X 2.75 % concentrates should not be mixed f nmal system operation.

System Calculation f Total Flooding Building n Light steel construction n Non-sprinklered Hazard n Low density combustibles Fill Time As stated in NFPA 11, the fill time f a non-sprinklered building of light steel construction and a hazard of low density combustibles is a maximum of 3 minutes (T). Building Area 100 ft (30.5 m) 30 ft (9.1 m) = 3,000 ft 2 (278 m 2 ) Building Height 10 ft (3 m) = Volume (V) of 30,000 ft 3 (850 m 3 ) Calculation Without Sprinklers R = (V/T) C N C L R = Rate of Discharge in cfm V = Submergence Volume in ft 3 T = Submergence Time in minutes C N = C L = Compensation f nmal shrinkage (1.15, constant) Compensation f leakage 1.0, no leakage 1.2, moderate leakage R = (30,000 ft 3 / 3 min) 1.15 1 = 10,000 1.15 1 = 11,500 cfm required Metric Calculation R = (850 m 3 / 3 min) 1.15 1 = 283.3 1.15 1 = 326 cmm required 326 cmm / 189 cmm per Metric JET-X 5A @ 3.4 bar = 1.73 generats System Calculation f Local Application Group II aircraft hangar using outside air to generats. Hangar to be protected n Group II hangar measuring 33,000 ft 2 (3066 m 2 ) n Sprinkler system (wet pipe) f 0.17 gpm/ft 2 over 5000 ft 2 (6.9 Lpm/m 2 over 465 m 2 ) Fill time As stated in NFPA 409, fill depth of 3 ft (0.9 m) within one minute (T) with sufficient foam concentrate f 12 minutes total. Building Area 150 ft 220 ft = 33,000 ft 2 (45.7 m 67.1 m = 3066 m 2 ) Foam Volume (V) 33,000 ft 2 3 ft = 99,000 ft 3 (2803 m 3 ) Calculation With Sprinklers R = ([V/T] + R s ) C N C A * R s = Rate of foam breakdown by sprinklers 10 cfm/gpm sprinkler system discharge in gpm (0.075 cmm/lpm sprinkler discharge in Lpm) C N = Compensation f nmal shrinkage (1.15 constant) C A * = Compensation f inside air (1.20 constant) C L = Leakage fact (not required f local application systems) R = ([99,000 ft 3 / 1 min] + 8500 cfm) 1.15 = 107,500 1.15 = 123,625 cfm minimum required 123,625 cfm / 27,303 cfm per JET-X 27 @ 75 psi = 4.53 generats Metric Calculation R = ([2803 m 3 / 1 min] + 241 cmm) 1.15 = 3044 1.15 = 3501 cmm minimum required 3501 cmm / 773 cmm per JET-X 27 @ 5.2 bar = 4.53 generats Therefe, use five JET-X 27 generats at 27,303 cfm (773 cmm) each. *Inside air may be used with AHJ approval. When using inside air, Tyco Fire Protection Products recommends using the 20% compensation fact (C A ) noted in the calculation f R. Contact Tyco Fire Protection Products Technical Services with questions on use of inside air f high-expansion foam systems.

Ordering Infmation Standard Models (Carbon Steel Construction) Part Generat Weight Number Model lb (kg) 2% Approvals 2.75% Approvals 420001 JET-X 2A 73 (33) UL, CE UL, CE 420003 JET-X 5A 255 (116) UL, FM, CE UL, CE 420005 JET-X 15A 397 (180) UL, FM, CE UL, CE 421590 JET-X 20 397 (180) UL, CE UL, CE 436899 JET-X 27 720 (327) UL, FM, CE CE LNG Models (Stainless Steel Construction) Part Generat Weight Number Model lb (kg) 2% Approvals 2.75% Approvals 471066 JET-X 2A LNG 73 (33) UL, CE UL, CE 436936 JET-X 5A LNG 255 (116) UL, FM, CE UL, CE 472526 JET-X 15A LNG 398 (180) UL, CE UL, CE 471871 JET-X 20 LNG 398 (180) UL, CE UL, CE JET-X 27 Dimensions 0.44 IN. DIA. (11.1 mm) 4 PLACES 36.0 IN. (914 MM) 13.8 IN. (348 mm) 5.0 IN. (127 mm) TOP VIEW 2 IN. NPT* 63.2 IN. (1607 mm) 40.0 IN. (1016 mm) 24.1 IN. (613 mm) 3.5 IN. DIA. (89 mm) 64.5 IN. (1638 mm) 32.2 IN. (819 mm) 13.8 IN. (348 mm) 92.8 IN. (2357 mm) 44.9 IN. (1143 mm) 5.0 IN. (127 mm) SIDE VIEW 60.8 IN. (1543 mm) FRONT VIEW (INLET END) * SIDE INLET ONLY 0.44 IN. DIA. (11.1 mm) 6 PLACES 36.0 IN. (914 mm) 8.0 IN. (203 mm) BOTTOM VIEW, MOUNTING HOLE LOCATIONS 008417

General Dimensions JET-X-5A DIA. 0.50 IN. (12.7 MM) 4 PLACES H A F E C SIDE VIEW 008770 G TOP AND BOTTOM VIEW MOUNTING HOLE LOCATIONS 008769 JET-X 2A, JET-X 15A (UL, FM, OR LNG), JET-X 20 DIA. 0.44 IN. (11.1 mm) 4 PLACES H D A F E C SIDE VIEW G TOP AND BOTTOM VIEW MOUNTING HOLE LOCATIONS 006371 ALL GENERATORS EXCEPT JET-X 27 B FRONT VIEW (INLET END) 001275 A B C D E F G H Model in. (mm) in. (mm) in. (mm) in. (mm) NPT in. in. (mm) in. (mm) in. (mm) JET-X 2A 25.0 (635) 25.0 (635) 30.1 (764) 3.9 (99) 1.0 16.0 (406) 3.3 (83) JET-X 5A 44.5 (1130) 42.1 (1069) 40.3 (1024) 6.4 (154) 1.5 27.0 (686) 18.5 (470) 6.1 (156) JET-X 15A (UL) 64.0 (1629) 64.0 (1629) 46.0 (1178) 8.5 (219) 2.0 36.0 (914) 5.0 (127) 8.0 (213) JET-X 15A (FM) 64.0 (1629) 64.0 (1629) 46.0 (1178) 8.5 (219) 2.0 36.0 (914) 5.0 (127) 8.0 (213) JET-X 15A (LNG) 64.0 (1629) 64.0 (1629) 46.0 (1178) 8.5 (219) 2.0 36.0 (914) 5.0 (127) 8.0 (213) JET-X 20 64.0 (1629) 64.0 (1629) 46.0 (1178) 8.5 (219) 2.0 36.0 (914) 5.0 (127) 8.0 (213) Note: The converted values in this document are provided f dimensional reference only and do not reflect an actual measurement. ANSUL and the product names listed in this material are trademarks and/ registered trademarks. Unauthized use is strictly prohibited.