Quality Assurance by Liz McChlery

Similar documents
Overview of Good Food Laboratory Practices

Project Proposal Form

Leveraging ISO s Quality Management System to Achieve 24/7 Inspection Readiness. Randy Querry Accreditation Manager Clinical

Good Laboratory Practice (GLP) Philip Cunningham St Vincent s s Hospital Sydney

Key changes in new BCSH Transfusion I.T. Guidelines. Debbie Asher EPA Network Transfusion Manager Member, BCSH Guideline Writing Group

General Accreditation Guidance. ISO/IEC 17025:2017 Gap analysis. April 2018

SECTION L QUALITY ASSURANCE. 1) designating and managing quality control functions, including:

BROOKHAVEN NATIONAL LABORATORY SBMS Interim Procedure

Quality Manual In support of ISO 9001:2015 ANSI/NCSL Z , ISO/IEC17025 ISO10012

Verification of Method XXXXXX

Good Clinical Practice (GCP): how does a laboratory that supports a clinical trial ensure compliance with these Regulations

Good manufacturing practices

General Accreditation Criteria Equipment assurance, in-house calibration and equipment verification

General requirements for the competence of testing and calibration laboratories. In this presentation:

INS QA Programme Requirements

Supplier Quality System Survey

CUSTOMER AND SUPPLIER ROLES AND RESPONSIBILITIES FOR 21 CFR 11 COMPLIANCE ASSESSMENT. 21 CFR Part 11 FAQ. (Frequently Asked Questions)

Perry Johnson Registrars, Inc. Licensed Copy #2 RECYCLING INDUSTRY OPERATING STANDARD. Prepared for ISRI Services Corporation

Required Elements of a Quality Management System

FACT Common Standards for Cellular Therapies, Second Edition. Summary of Changes

WHSE POL 1 WORK HEALTH, SAFETY & ENVIRONMENT MANAGEMENT POLICY

Quality Management System

Specific Accreditation Criteria

U. S. Department of Energy. Consolidated Audit Program Treatment, Storage and Disposal Facilities. Checklist 1 Quality Assurance Management Systems

DECISION TO ACCREDIT

EUROPEAN INDUSTRIAL PHARMACISTS GROUP. Guidance on CPD for QUALIFIED PERSONS

Terms and conditions for laboratories appointed to undertake the testing of compost under the Compost Certification Scheme aligned to PAS 100 and the

Project Procedure 1.0 PURPOSE 2.0 SCOPE 3.0 REFERENCES 4.0 DEFINITIONS. No.: P /21/2012 PAGE 1 OF 8 INTERNAL QUALITY AUDITS

Quality Assurance Policy and Procedures

Quality Management System MANUAL. SDIX, LLC Headquarters: 111 Pencader Drive Newark, Delaware 19702

TECHNICAL REQUIREMENTS (CLAUSE 5)

Brumund Foundry Inc.

EPICOR, INCORPORATED QUALITY ASSURANCE MANUAL

Traceability and Measurement Uncertainty within Clinical Biochemistry UKAS

Quality Management System

Standards of proficiency. Biomedical scientists

NEW YORK STATE DEPARTMENT OF HEALTH CLINICAL LABORATORY EVALUATION PROGRAM. Crosswalk of Proposed Revision to General Systems Standards

Point-of-care testing (POCT) Requirements for quality and competence

Strengthening Laboratory Management Toward Accreditation. Module 6: Quality Assurance

Quality Manual. Print Name Title Date Prepared by L Naughton QA Consultant 9 th April 09. Reviewed by Bernard Lennon Fire and Safety Officer

TNI s NATIONAL ENVIRONMENTAL LABORATORY ACCREDITATION PROGRAM (NELAP) Changing to the 2009 Standard

Laboratory Accreditation Test Validation: A Brave New World for Anatomic Pathology

Plan Subject Index Number Section Subsection Category Contact Last Revised References Applicable To Detail PRINCIPLE:

Quality Manual. This manual has been written to the ISO 9001:2000 International Quality Standard

While the recognition

Beaver Machine. Quality Manual

ISO General Requirements for Competence of Testing Laboratories Procedure

Establishing Quality Control Target Values and Standard Deviations for Hematology Instrumentation

Proprietary Document Disclosure Restricted To Employees and Authorized Holders

Service Suppliers Engaged in Condition Monitoring of Machinery Onboard Ships and Mobile Offshore Units

Risk Management in IVD Producer Relation between manufacturer and user. S.M.Boutorabi DCLS, PhD

Summary of TL 9000 R4.0 Requirements Beyond ISO 9001:2000

Association of American Railroads Quality Assurance System Evaluation (QASE) Checklist Rev. 1/12/2017

QUALITY POLICY MANUAL

ISO 9001:2015. Quality Management System. Manual

BCA Accreditation Regulation 17 Quality Assurance System Guidance. October 2008

Lucia M. Berte Laboratories Made Better! P.C. Broomfield, Colorado, USA

PROOF/ÉPREUVE A ISO INTERNATIONAL STANDARD. Environmental management systems Specification with guidance for use

Qualification of Highway Product Manufacturers Through the Use of NTPEP Audits

ISO /TS 29001:2010 SYSTEMKARAN ADVISER & INFORMATION CENTER SYSTEM KARAN ADVISER & INFORMATION CENTER

25 D.L. Martin Drive Mercersburg, PA (717)

Guidance on the Application. of ISO / IEC Accreditation International Association for Certifying Bodies

Quality Management. Carlos Bachier, MD

DEC STD ISO Quality Systems - Model for Quality Assurance in Design /Development, Production, Installation and Servicing

Quality Manual Revision: C Effective: 03/01/10

Laboratory Challenges with TNI Implementation and Laboratory Audits

HACCP audit checklist

Details: Approval: Distribution & Storage:

Common AABB Assessment Findings

Medical Cannabis Laboratory Approval Program

BAITY SCREW MACHINE PRODUCTS QUALITY MANUAL

QC results in true real-time

Reflection paper on guidance for laboratories that perform the analysis or evaluation of clinical trial samples

Common Deficiencies

Stanley Industries, Inc. ISO 9001:2008 Quality Policy Manual

ISO9001:2008 SYSTEM KARAN ADVISER & INFORMATION CENTER QUALITY MANAGEMENT SYSTEM SYSTEM KARAN ADVISER & INFORMATION CENTER

Reliance Aerospace Solutions

Quality System Manual - Section 00

INTERNATIONAL STANDARD

QUALITY MANUAL ECO# REVISION DATE MGR QA A 2/25/2008 R.Clement J.Haislip B 6/17/2008 T.Finneran J.Haislip

AAVLD Accreditation Committee - FAQ Archive

Quality Manual. Ingenuity at its best WEST INDUSTRIES LLC Silverton, Suite 924 San Diego, CA USA

A02 Assessment Rating Guide Revision 2.9 August 21, 2016

NR CHECKLIST Rev. 1. QAM IMP References NBIC Part 3, 1.8 Y N Y N a. Organization. Company Name/Certificate Number: Page 1 of 26

UNCONTROLLED DOCUMENT WHEN PRINTED

TERMS AND DEFINITIONS

QMS CO-ORDINATOR & GENERAL PROCEDURES:-

National Shellfish Sanitation Program (NSSP) Guide for the Control of Molluscan Shellfish: 2017 Revision

CAPITAL AVIONICS, INC. Quality Manual

Procedure for Biomedical Equipment Calibration and Maintenance

ENVIRONMENTAL LABORATORY APPROVAL PROGRAM CERTIFICATION MANUAL DATE 5/06/08

Quality Manual TABLE OF CONTENTS APPROVAL SIGNATURE PAGE AMENDMENT RECORD SCOPE EXCLUSIONS 2.1 3

BELDEN QUALITY SYSTEM OVERVIEW

Documenta tion and Records

<Full Name> Quality Manual. Conforms to ISO 9001:2015. Revision Date Record of Changes Approved By

A Division of Research Products Corporation

Diagnostic Accreditation Program 2015 Laboratory Medicine Accreditation Standards FAQ

MAINTENANCE OF QUALITY IN THE LABORATORY Dr Tom Hartley Quality Manager : Royal Hobart Hospital Senior Research Fellow : University of Tasmania

LABORATORY TRAINING LOGBOOK

Quality Management System Manual

Transcription:

Quality Assurance by Liz McChlery Define QA and Total Quality Management Describe Quality Control Define and distinguish Accuracy and Precision Define a Biological Reference Interval Describe ISO15189 within the medical Laboratory Outline Harmonisation as it relates to laboratory medicine Outline Internal and External Assessment Bodies Outline the concept of document control Outline Quality feedback from Customers Define TQM and QA Total Quality Management (TQM) is a comprehensive and structured approach to organizational management that seeks to improve the quality of products and services through ongoing refinements in response to continuous Feedback Quality Assurance: The maintenance of a desired level of quality in a service or product, especially by means of attention to every stage of the process of delivery or production. 1

Define: Quality Assurance and Total Quality Management Prevention Quality Assurance Total Quality Management Detection Describe Quality Control Quality control (QC) is a procedure or set of procedures intended to ensure that a manufactured product or performed service adheres to a defined set of quality criteria or meets the requirements of the client or customer. 2

Laboratory quality control is designed to detect, reduce, and correct deficiencies in a laboratory's internal analytical process prior to the release of patient results, in order to improve the quality of the results reported by the laboratory. Quality control is a measure of precision, or how well the measurement system reproduces the same result over time and under varying operating conditions. Laboratory quality control material is usually run at the beginning of each shift, after an instrument is serviced, when reagent lots are changed, after calibration, and whenever patient results seem inappropriate. Assays which are subject to drift or interference have more regular quality control checks. To ensure confidence in the results being produced. QC results on automated machinery is plotted into graphs to monitor performance and detect drift or failure. QC Material can be commercial Reproducibility checks using comparisons of patient samples across machines or sites such as NSH/WTK 3

4

Regardless of the type of examination that is performed, steps for implementing and maintaining a QC programme include: establishing written policies and procedures, including corrective actions training all laboratory staff ensuring complete documentation reviewing quality control data. Quantitative tests Controls are usually available in "high", "normal" and "low" ranges. For some assays, it may be important to include controls with values near the low end of detection. 5

Semi Quantitative and Qualitative Testing As with quantitative procedures, it is important to verify that results of qualitative and semi quantitative examinations are correct prior to reporting them to the requesting health care provider. Conducting QC for many of these tests is not as easily accomplished as with quantitative tests. Therefore, it becomes essential that other processes within the quality system are carefully conducted, in addition to traditional QC methods. Following are some important overarching concepts for quality that apply to qualitative and semi quantitative tests. Dedicated, professional staff who understand the principles of QC are key to quality. Incubators, refrigerators, microscopes, autoclaves and other equipment must be maintained and monitored carefully Positive and negative controls must be used to monitor the effectiveness of test procedures that use special stains or reagents and tests with end-points such as agglutination, colour change or other non-numeric results. Reagents should be stored according to the manufacturer s instructions, labelled with the date they are opened and put into use, and discarded at the expiration date 6

Sample management is important in all laboratory testing. Examinations that are dependent on a viable organism in the sample may need closer monitoring and better communication with non laboratory staff 7.3 Accuracy and Precision Think of accuracy like a dart board. The desired result is a bulls eye. If you hit it or close to it you have high accuracy. Precision is achieving the same result repeatedly. 7

Accuracy and Precision What is the difference? You could achieve a result consistently in the outer ring but it is not necessarily accurate. Accuracy and Precision What is the difference? 8

Labs endeavour to be both We like to be highly accurate and very precise Define a Biological Reference Interval Biological Reference Intervals are based on Clinical results for an analyte from a SPECIFIC population Large numbers of tests are performed and plotted into a graph which shows the normal distribution 9

Reference Interval What do we mean by Reference Interval (RI)? It is the range of values in which the laboratory can objectively interpret/report the generated results. This interpretation includes comparing test values against the population-based reference values. In other words, the normal values mean that the obtained values are typical of the values found in a specific population at large. Statistically, the values of the RI must be distributed in a bell-shaped (symmetrical Gaussian distribution). Gaussian Curve What does this Mean? All results from a large Population are plotted on a graph In a Normal distribution 68% of all results will lie within 1 standard deviation of the mean 95% of results will lie within 2 std Dev of the mean 99.7 will lie within 3 std. dev from mean 10

2) What are the factors affecting RI? The database of RIs for the same test can be different from one study to another. This is due to many factors which can be summarised as follow: a. Endogenous: this factor cannot be controlled. Age and sex are the main inherent factors. For example many circulated hormones can be affected by age and/or sex during the lifespan. b. Exogenous: this factor can be controlled. Fasting status, exercise and pregnancy are examples of factors which can be modified. c. Genetics and /or ethnicity: this is a population dependant factor. Also, the geographical location can be RI determinant. 3) How RI can be derived? The CLSI and IFCC recommendations can be followed to calculate the RI for any target population. The detailed statistical methods provided in these recommendations must be strictly adhered. Generally clinical Laboratories do not perform this function. Suppliers of reagents provide RI for each assay. 11

What does this mean? Blood tests are interpretable and relatable through all Labs in NZ Why? E.g. Patient with anaemia is tested in the community HB =65 is that g/l or g/dl (harmonisation) Arrives at Hospital HB is now 45 g/l Is it a Sampling error? Or lack of conformity in testing? Or does it represent a life threatening bleed? ISO 15189 International Organisation for Standardisation has produced a Quality document designed specifically for Laboratory environments (collaborative) Each year the laboratory is inspected to the ISO15189 v 2012 standard by IANZ(International Accreditation New Zealand) This covers: 12

Organisation and Management: Structure, Meetings Management Reviews. Quality Management System: Application of Internal and external Quality Controls. Maintenance, Recording Temps., Calibrations, Document Control- how our Documents are managed and updated. Service Agreements- with our users Contracts, Maintainence,Clients Examination by Referral Laboratories-are they accredited?, do they meet the same standards External Services and Supplies-Quality products that conform to industry standards. Documented suppliers lists Resolution of Complaints- What is our process? How to we manage complaints, Record keeping Identification and Control of Non-Conformities- How do we find non conformities. Documentation of what we do when identified. Examinations and reporting halted until resolved Corrective Actions: to eliminate cause of non conformities, notification to appropriate personnel including customers Preventative Action: determine the cause and introduce steps to prevent reoccurrence. Root cause analysis Continual Improvement: Continuous review of all systems against the stated intentions in the Quality Policy Control of Records: documented procedures for ID, Collection, Indexing, Access, storage, maintenance amendment and safe disposal of quality and technical records Evaluation and Audits: Implementation of Internal Audits which include preanalytical,testing and post examination stages to ensure conformity to standards, Staff suggestions, Risk Management Management Review: annual MRM to ensure Suitability, Adequacy, effectiveness to support patient care Technical Requirements: Personnel: Qualified, Current APC, Current Competency Signoff, Education, CPD Accommodation and Environment: Space, Environment, Waste management Laboratory Equipment Reagents and Consumables: Acceptance testing, Validation Instructions for, Calibrations, Servicing, Maintenance, Use, Traceability, Adverse Incidents 13

Pre examination Processes: Patient Information, Laboratory Intranet pages, Test Library, Request forms. Instructions for Collecting, transport. Sample reception, Handling Preparation Storage Examination Processes: Selection Verification and Validation of Exam procedures. QC, Inter lab Comparisons. UOM for quantitative results Quality of Examination Results: Documentation Standard SOP, Document control Post examination processes: Review of results, Storage and retention of clinical samples Reporting of results: Considerations printed, electronic, accurate understandable, unique identifier, date. Release control. LIS, Harmonization The Clinical and Laboratory Standards Institute refers to a definition of harmonization as the process of recognizing, understanding, and explaining differences while taking steps to achieve uniformity of results, or at a minimum, a means of conversion of results such that different groups can use the data obtained from assays interchangeably. Standardisation of pathology units and terminology. Harmonisation of report formats where there are patient safety issues, e.g. left to right versus right to left reporting. Harmonised reference intervals (RIs) and decision limits. Best practice evidence for test requesting. 14

Internal Audits Each year laboratories perform an Internal Audit. This is an inspection by our staff. We follow a template which covers all aspects of the laboratory. Review and make recommendations for improvements Ensure that any corrective actions are implemented before sign off WDHB uses our Internal Audit as a preparation for IANZ and use the ISO15189 as our audit tool. 15

External Audits External Auditing Bodies NZBS- both Clinical Audits of Transfusion Notes and Technical Audit of Laboratory Compliance Ministry for Primary Industries: for sites handling organisms and GM bacteria which are new to NZ Strict handling and disposal criteria apply to control the risk of exposure or release of harmful organisms IANZ IANZ: International Accreditation New Zealand Provide Labs with their accreditation which allows them to provide their service. All clinical laboratories must have IANZ accreditation. IANZ has the power to shut down laboratories by removing their accreditation if they feel the Quality of the testing is not up to standard. IANZ performs an annual Audit and makes requests for CAR Corrective Action Requests ( Non Conformances) SR Strong Recommendations(potential non conformities) R Recommendations (opportunity for Improvement) 16

Document Control Document : What constitutes a document? Paper, File, PDF, Electronic files, Emails Any document that may vary over time e.g. flow charts,procedural manuals, RI s Principles: Safe, Retrievable, Unchanged by time A permanent audit trail of changes Permanent record (25yrs for infant medical records) (3 yrs. for QC files) Computer records of data results What happens if RI changes? Manuals need to be archived if significant changes are being made and a new document released. All previous versions must be removed from the point of use 17

Documents are required to be authorised before put into use. Title Unique Identifier Current edition Page numbers Authority for issue Issue Date: February 14 Version 11.0 Issued by: Elizabeth McChlery G:\Lab\Quality\Manuals\Qmanual.doc Waitemata DHB Laboratory Quality Manual Section 1, Page 1 of 8 National Pathology Accreditation Advisory Committee The document Requirements for the Retention of Laboratory Records and Diagnostic Material represents the minimum standards for retention of records and materials. Individual Laboratories may choose to exceed these minimum requirements based on local circumstances and historical practice. 18

Ref General Retention Time Storage GDA 10.5 Audit Reports External Internal 10 years 7 years On site or off site at Crown Storage GDA 13.2 Personnel Current In training records in Service Lead office Resigned 7 years post resignation to meet WDHB policy HR after resignation GDA 1304 Rosters 7 years Individual disciplines GDA 2.8 Laboratory Methods/Procedures (manuals) While methods current plus 3 years superseded. Electronically archived GDA 2.7 QC and QA records 3 years On site or off site at Crown Storage GDA 2.7 Worksheets, Instrument printouts, calculations etc 3 years Note: Hard copies not required if identical information is available electronically. There is an exception when data has been changed on the result sheets from interfaced analysers. Individual record needs to be retained for 3 years. Either electronically or a worksheet in a retrievable form. NPAAC 1.3 Equipment/ Instrument Maintenance Life of the instrument plus 3 years Temperature charts 5 years On site or off site at Crown Storage On site GDA 9.15 Management Review/Quality Improvement 3 years On site GDA 10.14 10.15 Incident/Accident / Complaints Minor Major 7 years 10 years On site and electronic Quality Feedback Who can we get feedback from? DR, Nurses, Patients, Clients, Surveys,GP and Hospital user Survey. Annually Rate the service. Give suggestions for improvements Complements: What we did right Complaints Which do we learn more from? 19

Should not take as negative, each feedback is an opportunity to improve and refine our service Promotion of NO BLAME culture important. Reporting errors/incidents allow us to improve. And make changes which prevent future incidents and service development. All in all your just a-nother brick in the Wall Quality System Essentials Documents and Records. Information Management. Non conforming event management Personnel. Purchasing. Equipment. Process Management Organisation Quality Planning Process. Management Review Process Customer Focus. Complaints tracking Process. Customer Feedback Process Facilities and Safety. Disaster Management. Health Risk Assessment Process 20