The Liquiflo POLY-GUARD TM

Similar documents
Product Catalog. Challenge Us. With Your. T oughest. Pumping. Applications

ECLIPSE. NSF/ANSI 61* *Non-metallic Only EXTERNAL GEAR PUMP ENGINEERED PRODUCTS. Flow: up to 33 gpm (125 lpm)

Introduction. Ultra Reliable

PFA Lined MTA Series ANSI Pumps

Introduction. Ultra Reliable

Introduction. Ultra Reliable

Introduction. Ultra Reliable

FYBROC SERIES 2530 CLOSE-COUPLED SEALLESS PUMPS

A REVOLUTION IN PUMPING EFFICIENCY INTRODUCING THE NEW ALL-FLO PUMP. SIMPLE A simple leak free bolted design ensures quick and easy repairs EFFICIENCY

Close Coupled Sealless Pumps

AIR OPERATED DOUBLE DIAPHRAGM PUMPS

VIKING. Heavy-Duty, Foot-Mounted Sealless Internal Gear Pumps. Operating Range1: Nominal Flow Rates: Section 635 Page 635.

Close Coupled Sealless Pumps

FLOWSERVE CORPORATION Sealless Pumps. Sealless Pumps Product Training Program

MJ / MJ-B Series Standard Non Metallic Magnetic Drive Pumps

UNIVERSAL PRODUCT LINE: STAINLESS STEEL MAG DRIVE PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE

UNIVERSAL PRODUCT LINE: CAST IRON MAG DRIVE PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE

VIKING. Heavy-Duty, Foot-Mounted Sealless Internal Gear Pumps. Operating Range1: Nominal Flow Rates: Section 635 Page 635.

VIKING. Serving Applications For: Ambient-Temperature Solids Temperature-Critical Processes Extreme Environments

MAGNETIC DRIVEN GEAR PUMP TEF-MAG. Made in Germany

Fybroc Close Coupled Sealless Pumps FYBROC SERIES 2530 ASME/ANSI SPECIFICATION B73.1 DIMENSIONS FYBROC SERIES 2630 SELF-PRIMING

Fybroc Close Coupled Sealless Pumps FYBROC SERIES 2530 ASME/ANSI SPECIFICATION B73.1 DIMENSIONS FYBROC SERIES 2630 SELF-PRIMING

Chemical Pumps. For Highly Corrosive and Mildly Abrasive Service

Richter Heavy Duty Lined Mag-Drive ASME/ANSI Pumps

Pulp & Paper Industry

H-25 Series. Up to 20 gpm (75.7/min) H-25 Specialized Designs

Richter Lined Mechanically Sealed ISO/DIN and ASME/ANSI Pumps

G O R M A N - R U P P P U M P S POSITIVE DISPLACEMENT ROTARY GEAR PUMPS. GRpumps.com

WARRENDER, LTD. Services. Ammonia & CO² Circulation and Transfer Pumps

TECHNICAL HANDBOOK. ASME B73.1 Process Pump. Wilfley Sealing Technology. No Flush Water Required

D-35 Series. Up to 37 gpm (140 l/min) D-35 Specialized Designs

Goulds Chemical Process Pumps

AND EFFICIENCY Since 1986, All-Flo pumps have been built to last. Designed to live up to their name, All-Flo pumps are performance engineered and qual

GM-V. Chemical gear pumps Highly Corrosion-Resistant Sealless Gear Pump

NPSH S TRAINER PTC CORROSION RESISTANT IEC close-coupled BASEPLATE in-line MACHINED TENSI

Goulds Chemical Process Pump

INDEX WARRENDER...3 OVERVIEW...4 APPLICATIONS...5. WMCA (Centrifugal alloy pumps) WMCP (Centrifugal non-metallic pumps)...

Fristam FZX Sanitary Liquid-Ring Pumps

Richter Sealless Chemical Magnetic Drive Pumps

FLOWSERVE CORPORATION Polychem-GRP / PFA Lined Sealed ASME Pumps. Centrifugal ANSI Pumps Product Training Program

BFV Series. Fully Lined High Performance Butterfly Valves Engineered for Industries Most Hazardous & Corrosive Services

Experience In Motion INNOMAG U-MAG. Fluoropolymer-lined, Magnetic Drive Pump

IWAKI CHEMICAL GEAR PUMPS GM-V

12D SERIES THREE SCREW PUMPS ROTARY SCREW PUMPS

LMV Direct Drive API 610 Centrifugal Pumps Setting the industry standard in vertical pump design.

High Performance, Corrosive Handling Pleated Filters

AIR-OPERATED DOUBLE DIAPHRAGM PUMP

NDP-50 Specifications

Achieving Optimum Balance for Maximum Value. Miniature Precision PD Pumps. Engineered Solutions

NDP-40 Specifications

Series Overview. O/C: Pump S/K: Service Kit. Max System Pressure (MAWP) Ports. -46/232 C (-50/450 F) V Viton -29/204 C (-20/400 F) D EP

LIQUID-SPECIFIC PRODUCT LINE: ABRASIVE LIQUID PUMPS SERIES DESCRIPTION OPERATING RANGE: IMPROVEMENTS NOMINAL FLOW RATES:

PAHT C pumps ATEX PAHT C pump

GENESYS. PUMPS GENESYS 2x3x6 Designs and Features. Why GENESYS Today. What is B73lean and why is it better? PUMPS. B73lean THE PUMP PAYS FOR ITSELF!

PUMP SEAL PARTS GUIDE

Gear Pumps. Precise, Pulseless, Repeatable Performance. In Polymer Applications.

ENGINEERING. tel fax

VSX TECHNICAL BROCHURE

METAL & DUAL SEATED PISTON VALVES

Durco Guardian ASME (ANSI) Magnetic Drive Pump

- Tensile strength of 50,000 psi per ASTM D-638 or 345 Mpa - Notched Izod impact strength of 35 ft-lb/in per ASTM D-256 or 1868 J/M are achieved.

Experience In Motion. Durco Guardian ANSI Magnetic Drive Pump

Battery-Powered Magnetic Flow Meter

Air-Operated Double Diaphragm Pumps

ANTI-ABRASION CERAMIC BALL VALVE

Large Flange Connections Specification Type LF

RL Industrial Lobe Pumps RL Series. Performance. Nomenclature. Product Description. Section 270 Page Issue A

Dimensionally Interchangeable, Sealless Mag Drive Pumps for Crucial Liquid Containment Applications

ProMinent Evolution Series

Weir Valve Selections

AMX - GG PUMP RANGE. Part of the MAGNETIC DRIVE Pump Range AMX-GG OVERVIEW REDUCED LIFE CYCLE COST HIGH EFFICIENCY DESIGN PLASTIC MAGNETIC DRIVE PUMPS

griswold EF&G Heavy Duty end suction

G L Pumps. SSV Series. Vertical Multistage Pumps. New!! Expanded Range Capable of Flows up to 650 GPM!! Goulds Pumps.

VESSEL & REACTOR VALVES. VR Series RISING DISC PROCESS VALVES. Sold by: G&W Industrial Sales

Ceramic Lined Double Mechanical Seal Centrifugal Pump Efficient Non-Corroding Abrasion-Resistant

Seal-less Pump Technology. Oil and Gas. Robust design - Reliability

T Series. Self-Priming Centrifugal Pumps

Battery-Powered Magnetic Flow Meter

D, T, & P SERIES. Magnetically Coupled Precision Pumps. Pump Your Heart Into It

HD Engineering Data Pack

Product information. UP-DO Pump Series Normal priming, centrifugal pumps with a double mechanical seal material: stainless steel 1.

Goulds Multistage Process Pumps

Colfax Americas. Crude Oil Transport Solutions

VESSEL & REACTOR VALVES. VD Series DISC VALVES PROCESS VALVES

SUNFLO Industrial Grade High-Pressure Pumps

FLOWSERVE CORPORATION Guardian Pumps. Centrifugal ANSI Pumps Product Training Program

ABAQUE. Bulletin E. Where Innovation Flows. mouvex.com

Chlor-alkali Electrolysis

Engineering Data Pack HD Industrial Duty Pumps

Experience In Motion ECPJ. API 610 (VS4) Vertical Sump Pump

Advanced S O L U T I O N S

ABAQUE. Bulletin E. Where Innovation Flows. mouvex.com

W ARR A NTY FAIRBANKS NIJHUIS 1600 SERIES SINGLE STAGE END SUCTION PUMPS. Certified to NSF/ANSI 372.

SINGLE STAGE END SUCTION PUMPS AURORA Series. Distributed By: Model 3804

B-476C. t e c h n i c a l b u l l e t i n

GASKET MATERIALS. Click the Product Name to go Directly to Any Page Expanded PTFE Sheet Material QUIMFLEX SH 100% Expanded PTFE Sheet...

Series A-C Single Stage Double Suction Large Split Case. TECHNICAL Brochure BAC9100

abcdef EMV/S/Kseries Vertical Multistage Centrifugal Pumps where innovation f l ow s SNG

SCAN TO VIEW PRODUCT ANIMATION. Universal TS Series ROTARY POSITIVE DISPLACEMENT TWIN SCREW PUMPS

Electric Diaphragm Pumps Electric Operated Double Diaphragm Pump

Transcription:

A Revolutionary Innovation in Chemical Pump Technology... The Liquiflo POLY-GUARD Polymer-Lined Stainless Steel Gear Pump...The Ultimate Solution for Pumping Corrosive Chemicals Combines the chemical resistance of Fluoro-Polymers with the strength of Stainless Steel tm

Description: THE TOUGHEST COMBINATION... L I Q U I F L O C H E M I C A L P R O C E S S I N G P U M P S Liquiflo has long recognized the need for a Plastic Rotary Positive Displacement Pump for the chemical industry. While engineered plastics offered unsurpassed chemical resistance to virtually any fluid, they severely lacked the mechanical strength, integrity and safety of high-alloy metals. Therefore, the challenge was to use a combination of metal and plastic to produce a highly corrosion resistant pump that was safe to use in industrial applications. We chose a Fluoro-Polymer for its superior chemical resistance, and Stainless Steel for its strength and corrosion resistance (giving the pump one more layer of protection). Liquiflo perfected a specialized molding and machining technique for mechanically bonding, stabilizing and machining the plastic to exacting tolerances required to make a positive displacement pump. The ultimate outcome was the Poly-Guard, which combines the chemical resistance of a Fluoro-Polymer with the strength of Stainless Steel. Advantages Typical Uses & Applications The Poly-Guard is an excellent choice for inorganic acids, bases and salts. The Poly-Guard, with its tough Stainless Steel exterior and chemically resistant Fluoro-Polymer interior, offers the ultimate solution for your most difficult chemical applications. These pumps are durabie, safe and corrosion resistant, and unlike fiber-reinforced plastic pumps, they can also be used in high purity services where contamination from process system components must be avoided. Typical Chemicals Hydrochloric Acid Ferric Chloride Sulfuric Acid Hydrofluoric Acid Sodium Hypochlorite Nitric Acid Sodium Hydroxide Chromic Acid Fluorosilicic Acid Hydrogen Bromide Bromine Markets Chemical Water Treatment Pharmaceutical Pulp & Paper Electronics Food & beverage High Purity Service...etc. Metering Gear pumps, due to their nearly pulseless flow, are preferred in many metering applications. When used with a VFD in a PID-controlled feedback loop, the pump can deliver exceptionally accurate flow. The input signal can be based on many different parameters ph and flow being two of the most common. The Poly-Guard offers both internal and external protection against corrosive fluids and harsh environments Strong Stainless Steel body handles pipe stresses and typical treatments found in industrial environments Fluoro-Polymer-lined for ultimate protection against any corrosive liquids, such as Acids, Caustics, Inorganic Salts and others A variety of non-metallic materials for internal components such as PEEK, Kynar (PVDF), Teflon, Silicon Carbide and TTZ, were chosen for exceptional wear resistance and chemical compatibility, allowing pump to be optimized for the intended service Ideal for high purity services (All wetted parts are non-metallic) Sealless Mag-Drive configuration prevents leakage Rotary Gear Pump design deliverer a smooth, pulseless flow which is desirable for both metering and transfer applications Close-Coupled configuration simplifies installation and maintains perfect alignment of pump and motor Product is extremely simple in design and easy to maintain and repair Available in sizes to match your flow requirements up to GPM ( ) tel... fax... LIQUIFLO.COM

CENTER HOUSING FRONT HOUSING INNER MAGNET CONTAINMENT CAN REAR HOUSING IDLER SHAFT IDLER GEAR C-CAN O-RING WEAR PLATES DRIVE GEAR DRIVE SHAFT HOUSING O-RINGS BEARINGS The Poly-Guard Series pumps offer a durably constructed outer Stainless Steel body with a heavily layered Fluoro-Polymer (PFA) internal lining. This highly chemically resistant PFA lining is mechanically attached and bonded to the internal stainless steel surfaces using a specialized molding process, effectively isolating the fluid being pumped from any metal surfaces. Fluoro-Polymers exhibit the highest corrosion resistance of any plastics. This combination of stainless steel on the outside and Fluoro-Polymer on the inside gives the Poly-Guard the full strength and integrity of a metal pump with the ultimate corrosion resistance of a Fluoro-Polymer. (Polymer lining is shown in gold) Case History A water supply authority was required to fluoridate the water system for a large metropolitan area. The method chosen was metered injection of concentrated Hydrofluorosilicic Acid into the water supply. Any process Interruption or fluid leakage would be unacceptable. Originally, diaphragm metering pumps were specified, however they were found to be unsatisfactory due to leakage as a result of diaphragm failure. They then chose a gear pump with an Alloy-C body; however, the Alloy-C was severely attacked by the acid resulting in fluid leakage within a month. Liquiflo was then approached to help them find a solution. Liquiflo recognized that an all metal pump was not acceptable from a corrosion standpoint. It was also known that glass and carbon were incompatible with this highly corrosive acid. This eliminated the option of using an all plastic pump that used carbon or glass fiber reinforcement. The solution was the Poly-Guard pump with PFA lining, Stainless Steel body, unfilled PVDF gears, and Silicon Carbide wear plates, bearings and shafts. These pumps have now been in service in excess of months with zero down time due to fluid leakage or degraded performance. LIQUIFLO.COM tel... fax...

S P-P S P-P GENERAL SPECIFICATIONS SPECIFICATION Units P P P P P P P Port Size & Type* ANSI # in / / / / / / / DIN PN mm Theoretical Displacement gal/rev....... L/rev....... RPM Max Flow Rate GPM.............. Max Differential Pressure PSI bar Max Allowable Pressure PSIG barg F C NPSHR @ ft.. m....... Suction Lift (Dry) ft. m....... Weight, less motor (approx.) lbs kg * Raised Face (RF) Flanges Based on Maximum Speed and zero Differential Pressure. Based on pressure rating of Flanges at ambient temperature. MATERIALS AVAILABLE BODY SS-PFA Plastic-Lined GEARS PEEK Kynar Ryton Teflon WEAR PLATES Silicon Carbide Carbon- Teflon BEARINGS Silicon Carbide Carbon- SHAFTS Silicon Carbide Ceramic Zirconia Self-sintered SiC Transformation Toughened Zirconia (TTZ) tel... fax... LIQUIFLO.COM

P Port Size & Type ANSI / # RF Flanges DIN mm PN RF Flanges Theoretical Displacement. gal/rev (. L/rev) RPM Max Flow Rate. GPM (. ) Max Differential Pressure PSI ( bar) Max Allowable Pressure PSIG ( barg) F ( C) NPSHR @ ft (. m) Suction Lift (Dry). ft (. m) Motor Frame Sizes NEMA C, TC, TC IEC,, B Flange Weight, less motor (approx.) lbs ( kg) Based on Maximum Speed and zero Differential Pressure. Based on pressure rating of Flanges at ambient temperature.. cp CPS Fluid Fluid (Water) (Water)... cp CPS Fluid Fluid (Oil) (Oil)................................................ P: Mag-Drive, Close-Coupled. []. []. []. []. []. [.]. [.]. []. [.] / ANSI # or DIN PN. []. [] LIQUIFLO.COM tel... fax...

tm P Port Size & Type ANSI / # RF Flanges DIN mm PN RF Flanges Theoretical Displacement. gal/rev (. L/rev) RPM Max Flow Rate. GPM (. ) Max Differential Pressure PSI ( bar) Max Allowable Pressure PSIG ( barg) F ( C) NPSHR @ ft (. m) Suction Lift (Dry) ft (. m) Motor Frame Sizes NEMA C, TC, TC IEC,, B Flange Weight, less motor (approx.) lbs ( kg) Based on Maximum Speed and zero Differential Pressure. Based on pressure rating of Flanges at ambient temperature. CPS cp Fluid (Water).......... cp CPS Fluid Fluid (Oil) (Oil)................... P: Mag-Drive, Close-Coupled. []. []. []. []. []. [.]. [.]. []. [.] / ANSI # or DIN PN. []. [] tel... fax... LIQUIFLO.COM

P Port Size & Type ANSI / # RF Flanges DIN mm PN RF Flanges Theoretical Displacement. gal/rev (. L/rev) RPM Max Flow Rate. GPM (. ) Max Differential Pressure PSI ( bar) Max Allowable Pressure PSIG ( barg) F ( C) NPSHR @ ft (. m) Suction Lift (Dry) ft (. m) Motor Frame Sizes NEMA C, TC, TC IEC,, B Flange Weight, less motor (approx.) lbs ( kg) Based on Maximum Speed and zero Differential Pressure. Based on pressure rating of Flanges at ambient temperature......... cp CPS Fluid Fluid (Water) (Water)...... CPS cp Fluid Fluid (Oil) (Oil).............. P: Mag-Drive, Close-Coupled. []. []. []. []. []. [.]. [.]. []. [.] / ANSI # or DIN PN. []. [] LIQUIFLO.COM tel... fax...

tm P Port Size & Type ANSI / # RF Flanges DIN mm PN RF Flanges Theoretical Displacement. gal/rev (. L/rev) RPM Max Flow Rate. GPM (. ) Max Differential Pressure PSI ( bar) Max Allowable Pressure PSIG ( barg) F ( C) NPSHR @ ft (. m) Suction Lift (Dry) ft (. m) Motor Frame Sizes NEMA C, TC, TC IEC,, B Flange Weight, less motor (approx.) lbs ( kg) Based on Maximum Speed and zero Differential Pressure. Based on pressure rating of Flanges at ambient temperature. CPS cp Fluid (Water). cp CPS Fluid Fluid (Oil) (Oil)............... P: Mag-Drive, Close-Coupled. []. []. []. []. []. [.]. [.]. []. [.] / ANSI # or DIN PN. []. [] tel... fax... LIQUIFLO.COM

P Port Size & Type ANSI / # RF Flanges DIN mm PN RF Flanges Theoretical Displacement. gal/rev (. L/rev) RPM Max Flow Rate. GPM (. ) Max Differential Pressure PSI ( bar) Max Allowable Pressure PSIG ( barg) F ( C) NPSHR @. ft (. m) Suction Lift (Dry) ft (. m) Motor Frame Sizes NEMA C, TC, TC, TC, TC IEC,,,, B Flange Weight, less motor (approx.) lbs ( kg) Based on Maximum Speed and zero Differential Pressure. Based on pressure rating of Flanges at ambient temperature. cp CPS Fluid Fluid (Water) (Water) cp CPS Fluid Fluid (Oil) (Oil).............. P: Mag-Drive, Close-Coupled. [.]. []. []. []. []. [.]. [.]. []. [] / ANSI # or DIN PN. []. [] LIQUIFLO.COM tel... fax...

tm P Port Size & Type ANSI / # RF Flanges DIN mm PN RF Flanges Theoretical Displacement. gal/rev (. L/rev) RPM Max Flow Rate. GPM (. ) Max Differential Pressure PSI ( bar) Max Allowable Pressure PSIG ( barg) F ( C) NPSHR @. ft (. m) Suction Lift (Dry) ft (. m) Motor Frame Sizes NEMA C, TC, TC, TC, TC IEC,,,, B Flange Weight, less motor (approx.) lbs ( kg) Based on Maximum Speed and zero Differential Pressure. Based on pressure rating of Flanges at ambient temperature. CPS cp Fluid (Water) CPS cp Fluid Fluid (Oil) (Oil).................. P: Mag-Drive, Close-Coupled. [.]. []. []. []. []. [.]. [.]. []. [] / ANSI # or DIN PN. []. [] tel... fax... LIQUIFLO.COM

P Port Size & Type ANSI / # RF Flanges DIN mm PN RF Flanges Theoretical Displacement. gal/rev (. L/rev) RPM Max Flow Rate. GPM (. ) Max Differential Pressure PSI ( bar) Max Allowable Pressure PSIG ( barg) F ( C) NPSHR @ ft (. m) Suction Lift (Dry) ft (. m) Motor Frame Sizes NEMA C, TC, TC, TC, TC IEC,,,, B Flange Weight, less motor (approx.) lbs ( kg) Based on Maximum Speed and zero Differential Pressure. Based on pressure rating of ANSI # Flanges at ambient temperature. cp CPS Fluid Fluid (Water) (Water).......... cp CPS Fluid Fluid (Oil) (Oil)..... P: Mag-Drive, Close-Coupled. [.]. []. []. []. []. [.]. [.]. []. [] / ANSI # or DIN PN. []. [] LIQUIFLO.COM tel... fax...

L I Q U I F L O C H E M I C A L P R O C E S S I N G P U M P S PUMP CODING tm EXAMPLE: PLPPBBBVU, designates a Model P Pump with the following mat l selection. P Liquiflo s Model Code describes both the pump s size and materials selected. This model code is required for the future identification of your pump when reordering either a pump or replacement parts. Available CF L P P B B B V U Pos. Description Selection Pump Model P P Pump Body Mat l/ports L SS/PFA & ANSI Flanges Drive Gear Mat l P PEEK Idler Gear Mat l P PEEK Wear Plate Mat l B Silicon Carbide Bearing Mat l B Silicon Carbide Motor Frame Size. (/TC) Containment Can Alloy-C/PFA-Lined Bearing Flush None Shafts B Silicon Carbide O-Rings V Viton Mag Coupling U MCU Not Available Contact Factory Flanges available: ANSI & DIN CONNECTION SIZES P P P P ANSI # / / DIN PN Selection & Availability Model Body Material & Port Type Drive Gear Idler Gear Wear Plates Bearings Motor Frame Size Containment Can Bearing Flush Shafts O-Rings Magnetic Coupling Suffix Trim Options Sample Model No. No. Pump Model P L P P B B B V U P P P P P P P L = SS/PFA Lined & ANSI Flanges E = SS/PFA Lined & DIN Flanges = Teflon = Ryton P = PEEK K = Kynar = Teflon = Ryton P = PEEK K = Kynar = Teflon B = Silicon Carbide E = Carbon B = Silicon Carbide E = Carbon =. (NEMA C) =. (NEMA /TC) = mm (IEC - B) = mm (IEC - B) = mm (IEC - B) =. (NEMA /TC) = mm (IEC / - B) = Alloy-C/PFA-Lined F = Carbon Fiber/PFA-Lined CF CF CF CF CF CF CF = Standard Housings (without Bearing Flush) B = Silicon Carbide Z = TTZ (Zirconia) E = EPDM V = Viton K = Kalrez U = (MCU) in-lbs B = (MCB) in-lbs - = Temperature Trim - D = Viscosity Trim (double clearance) - T = Viscosity Trim (triple clearance) Copyright Liquiflo All rights reserved. - PFA tel... fax... www.liquiflo.com North Avenue Garwood New Jersey USA For over years, Liquiflo pumps have handled thousands of difficult chemicals