Simplified Method for Determining the Radiochemical Purity of 99m Tc-MAG3

Similar documents
A new two-strip TLC method for the quality control of technetium-99m mercaptoacetyltriglycine

Characterization and Quality Control Analysis of 99m Tc-Bicisate

The instant thin-layer chromatography (ITLC) method of

After reviewing this tutorial, the user should be able to Topics to be covered

Cold kit with higher 99m Tc activities - A Chromatographic Study. Introduction. Correspondence author: RADIOPHAMATHTICAL, ORIGINAL ARTICLE

Technescan MAG3. NAME OF THE MEDICINE Technescan MAG3 Kit for the Preparation of Technetium ( 99m Tc) Mertiatide.

A Simple Rapid and Sensitive Method Development for Quantification of Quetiapine Fumarate in Bulk and Dosage Forms Using RP-HPLC

Ge / 68 Ga GENERATOR* HOW TO DO PET AS SIMPLY AS SPECT? EXCELLENCE DEDICATED TO NUCLEAR MEDICINE, HEALTHCARE & ENVIRONMENT

STUDY OF THE ELUTION OF 99 Mo- 99m Tc GENERATORS PRODUCED AT IPEN-CNEN/SP

Validation of Analytical Methods used for the Characterization, Physicochemical and Functional Analysis and of Biopharmaceuticals.

CHAPTERS 1, 2 and 3 CHAPTER-4 CHAPTER-5,

Latest USP Initiatives: Monographs, General Chapters, and Compounding

Validation of a Dual Wavelength Size Exclusion HPLC Method with Improved Sensitivity to Detect Aggregates of a Monoclonal Antibody Biotherapeutic

VALIDATION OF ANALYTICAL PROCEDURES: METHODOLOGY *)

procedu Education And Continuing - Page 1 of 27 -

DEVELOPMENT AND VALIDATION OF ANALYTICAL METHOD FOR ASSAY DETERMINATION OF ISOSULFAN BLUE BY LIQUID CHROMATOGRAPHY

PHYSICO-CHEMICAL, BIOLOGICAL OR MICROBIOLOGICAL TESTS OF MEDICINAL PRODUCTS

10. Validated Normal Phase HPLC Method for the Determination. Fulvestrant is primarily used in the treatment of hormone receptor

Impurity Control in the European Pharmacopoeia

THE INTERNATIONAL PHARMACOPOEIA

TBIA101 LABELED WITH 68

Size Exclusion Chromatography of Biosimilar and Innovator Insulin Using the Agilent AdvanceBio SEC column

VICH Topic GL2 (Validation: Methodology) GUIDELINE ON VALIDATION OF ANALYTICAL PROCEDURES: METHODOLOGY

Different Models for Cost-Effective Fractionation of Bone Radiopharmaceuticals; Methylene Diphosphonate (MDP) & Hydroxymethylene Diphosphonate (HDP)

RADIOPHARMACY GMP QC HPLC VALIDATION

Lead cation exchange and alumina columns for concentration of 99m Tc-pertechnetate

Separate and Quantify Rituximab Aggregates and Fragments with High-Resolution SEC

SUMMARY OF PRODUCT CHARACTERISTICS (PHYTATE) mg. Quantity per vial Function. Tc-Technephyte GBq information

Analytical Methods Development and Validation

EAG.COM MATERIALS SCIENCES APPLICATION NOTE. By J. Tompkins 1, T. Spurgeon 1, R. Tobias 1, J. Anders 1, E. Butler-Roberts 2, and M.

Usharani Gundala* 1, Chandrashekar Bonagiri 2, Devanna Nayakanti 3

Validation of a concentration assay using Biacore C

5.19. EXTEMPORANEOUS PREPARATION OF RADIOPHARMACEUTICAL PREPARATIONS

High-resolution Analysis of Charge Heterogeneity in Monoclonal Antibodies Using ph-gradient Cation Exchange Chromatography

Chemical Aspects of Stability Evaluation

9/2/2014. USP Monograph Modernization. Todays topics. USP basic. Todays topics. - USP basic. - USP publications. - USP monograph modernization

INTERNATIONAL RESEARCH JOURNAL OF PHARMACY

GUIDANCE NOTES ON ANALYTICAL METHOD VALIDATION

A validated stability indicating HPTLC method for determination of nitazoxanide

QUALITY CONTROL AND ASSURANCE OF Tc-99m GENERATORS AND KITS APPLIED IN SAEC LABORATORIES

Impurities from degradation of Drug Substances

Determination of 99 Mo contamination in 99m Tc elute obtained from 99 Mo / 99m Tc- generator

CLSI C60: Assay Validation & Post-Validation Monitoring

Quantitative determination of residual 2-(2-chloroethoxy) ethanol (CEE) in quetiapine fumarate by gas chromatogaraphy

THESIS SUBMITTED TO THE ANDHRA UNIVERSITY IN PARTIAL FULFILMENT FOR THE AWARD OF THE DEGREE OF DOCTOR OF PHILOSOPHY IN PHARMACEUTICAL SCIENCES

Latest Developments in USP Monographs and the Compounding of Sterile Radiopharmaceuticals. Jim Ponto, MS, RPh, BCNP

Developing Robust and Efficient IEX Methods for Charge Variant Analysis of Biotherapeutics Using ACQUITY UPLC H-Class System and Auto Blend Plus

INTERNATIONAL PHARMACOPOEIA MONOGRAPH ON ARTEMETHER AND LUMEFANTRINE CAPSULES REVISED DRAFT FOR DISCUSSION

CALA Disputes

Pharmaceutical Reference Standards: Overview and Role in Global Harmonization

( ) IONPAC ATC-HC ANION TRAP COLUMN

European Pharmacopoeia. New monographs and chapters in the European Pharmacopoeia

Proposed Revision of USP General Chapter Radiopharmaceuticals for Positron Emission Tomography Compounding <823>

Guideline on setting specifications for related impurities in antibiotics

STABILITY TESTING OF NEW DRUG SUBSTANCES AND PRODUCTS

Automatic Combination of Orthogonal Separation Modes for Multiple Components in Mixtures

Quantification of genotoxic "Impurity D" in Atenolol by LC/ESI/MS/MS with Agilent 1200 Series RRLC and 6410B Triple Quadrupole LC/MS

Capture of mouse monoclonal antibodies

S U M M AR Y O F P R O D U C T C H AR AC T E R I S T I C S

DACLATASVIR TABLETS (DACLATASVIRI COMPRESSI) Proposal for The International Pharmacopoeia. (May 2018)

WHO GUIDELINE Stability testing of active pharmaceutical ingredients and finished pharmaceutical products

Preparative, Pilot & Process Columns

Improving Resolution and Column Loading Systematically in Preparative Liquid Chromatography for Isolating a Minor Component from Peppermint Extract

Application note. Guideline for validation of analytical methods using Cedex Bio, Cedex Bio HT, and Cedex HiRes Analyzers.

As reported before, the employed dose was 10 mg/ml is in according with commonly used dose.

Separation of Recombinant Human Erythropoietin (repo) Using Agilent Bio SEC-3

Reversed-phase Separation of Intact Monoclonal Antibodies Using Agilent ZORBAX Rapid Resolution High Definition 300SB-C8 1.

Perspectives on Method Validation: Importance of Adequate Method Validation

Regulatory aspects: Radiopharmacy (GMP)

European Medicines Agency Inspections

Chromatography 2015, 36, Technical Note

Implementation of a Walk-Up High- Pressure Capillary Ion Chromatograph for the Fast Separation of Pharmaceutical Relevant Inorganic Anions and Cations

Lakshmana Rao et.al Indian Journal of Research in Pharmacy and Biotechnology ISSN: (Print) ISSN: (Online)

Automating HPLC and GC Analytical Method Validation Fusion AE Software Program White Paper

á1225ñ VALIDATION OF COMPENDIAL PROCEDURES

USP Chapter 823 USP 32 (old) vs. USP 35 (new)

Quantitatitive Analysis of Phosphorothioate Oligonucleotide in Human Plasma Using LC-MS/MS with On-Line Extraction

Mimetic Blue Affinity Adsorbents Mimetic Blue 1 P6XL, Mimetic Blue SA P6XL Mimetic Blue SA HL P6XL, Mimetic Blue ELISA Kit

Agilent SD-1 Purification System. Purify your way SD-1

Automated Scouting of Stationary and Mobile Phases Using the Agilent 1290 Infinity II Method Development Solution

International Journal of ChemTech Research CODEN (USA): IJCRGG, ISSN: , ISSN(Online): Vol.10 No.6, pp , 2017

Automating HPLC and GC Analytical Method Validation Fusion AE Software Program White Paper

EVALUATION FOR STABILITY DATA

HiTrap NHS-activated HP

THALLOUS ( 201 Tl) CHLORIDE INJECTION: Revised Final text for addition to The International Pharmacopoeia (January September 2009)

GUIDELINE FOR THE STABILITY TESTING

APPLICATION NOTE. UOP : Analysis of Trace CO and CO 2 in bulk H 2 and Light Gaseous Hydrocarbons by GC

Online UPLC Method for the Support of Cleaning Validation and the Routine Monitoring of Cleaning Procedures

STUDYING THE ACCELERATED PHOTOSTABILITY OF CIPROFLOXACIN AND LOMEFLOXACIN IN TABLETS AND EYE DROPS

Streptavidin Mag Sepharose

Application Note. Author. Abstract. Biopharmaceuticals. Verified for Agilent 1260 Infinity II LC Bio-inert System. Sonja Schneider

A novel approach to Protein A capture chromatography to help decrease cost of clinical manufacturing and reduce supply chain risk

Seamless Method Transfer from an Agilent 1260 Infinity Bio-inert LC to an Agilent 1260 Infinity II Bio-inert LC

Development and Validation of Isoniazid in Bulk and Pharmaceutical Dosage Forms by UFLC Method

TSK-GEL BioAssist Series Ion Exchange Columns

3. Close the bottom end of the column and apply the packing device on top. Pump water through the upper adaptor to remove air.

Development and validation of stability indicating RP-HPLC method for the estimation of Daclatasvir in bulk and formulation

Charge Heterogeneity Analysis of Rituximab Innovator and Biosimilar mabs

Automated QbD-Based Method Development and Validation of Oxidative Degraded Atorvastatin

Transcription:

Simplified Method for Determining the Radiochemical Purity of Tc-MAG3 Shankar Seetharaman 1, James R. Ballinger 2, and Michael H. Sosabowski 3 1 Pharmaceutical Quality Assurance, Guy s and St. Thomas Hospital, London, United Kingdom; 2 Nuclear Medicine, Guy s and St. Thomas Hospital, London, United Kingdom; and 3 Department of Pharmacy and Biomolecular Sciences, University of Brighton, Moulscoomb, United Kingdom Tc-Mercaptoacetyltriglycine is used for dynamic renal imaging, and the summary of product characteristics (SPC) for the European formulation specifies a shelf life of 1 or 4 h, depending on the reconstitution volume of the kit. To minimize the time required to test the radiochemical purity, a simplified quality control method was developed. Methods: To satisfy the recommendations of the International Commission on Harmonisation, results obtained with the methods described in the European and American SPCs were compared with those obtained with the simplified method. Further validation of the new method was performed by comparison with the standard 2-strip thin-layer chromatographic method as well as tests for linearity and limits of detection and quantification. Results: The simplified method provided results comparable to those provided by the registered SPC methods but was more rapid to perform and used smaller volumes of solvents. Conclusion: The simplified method is a reasonable alternative to the registered SPC methods. Key Words: Tc-MAG3; analytic method; radiochemical purity J Nucl Med Technol 2006; 34:179 183 Technetium--mercaptoacetyltriglycine ( Tc-MAG3) is a radiopharmaceutical used in dynamic renal imaging. It is prepared by adding sodium pertechnetate to a sterile lyophilized kit and heating for 10 min in a boiling water bath. The current summary of product characteristics (SPC) distributed with the European Tc-MAG3 kit describes 2 methods for testing the radiochemical purity (RCP) of the product, highpressure liquid chromatography (HPLC) and the use of a solid-phase extraction (SPE) cartridge. Although HPLC is the more accurate method, the SPE method is more convenient for routine use and has been shown to provide equivalent results (1). The SPC distributed with the American Tc- MAG3 kit describes a slightly different SPE method for determination of the RCP. The 2 methods are compared in Table 1, where it can be seen that the European method is Received Feb. 1, 2006; revision accepted May 15, 2006. For correspondence or reprints contact: James R. Ballinger, PhD, Nuclear Medicine, Guy s and St. Thomas Hospital, St. Thomas St., London SE1 9RT, United Kingdom. E-mail: james.ballinger@gstt.nhs.uk COPYRIGHT ª 2006 by the Society of Nuclear Medicine Technology, Inc. more complicated than the American method because of the requirement for phosphate buffer and 2 different concentrations of ethanol. Both the European and the American SPE methods for RCP testing require the slow elution of comparatively large volumes of solvents. Vinberg has shown that the elution rate of the SPE method is important (2); indeed, the elution rate is crucial if reliable results are to be obtained, with slower elution rates yielding higher RCP values. An elution rate of 1.5 ml/min was found to be the maximum limit, although recent work suggested that slow elution rates are not critical (3). It is therefore proposed that the European and American SPE methods may not be the best use of limited equipment and time in radiopharmacies and that a new, simpler, and quicker method should be developed and validated. Accordingly, we have developed a simplified method that addresses some of these limitations. The new method is quicker and uses fewer solvents. In addition, the method helps reduce the possibility of spurious results being obtained because of an overly enthusiastic operator. The method is summarized in Table 2. The ICH Q2B regulations of the International Commission on Harmonisation (ICH) describe the requirements of a new test method that need to be satisfied for the method to be accepted as valid (4). Any new analytic method needs to be validated against the current registered methods to ensure compliance with the ICH Q2B regulations. Accordingly, our new method was validated against the methods specified in the European and American SPCs. MATERIALS AND METHODS All radiopharmaceutical kits (Technescan MAG3, European formulation; Tyco Healthcare) were prepared with Tc-pertechnetate eluted from a 99 Mo Tc generator (Drytec; Amersham Health) and heated for 10 min in a shielded boiling water bath. The kits were prepared in accordance with the SPC, except in circumstances when larger quantities of Tc (up to 2,000 MBq) were added. All activities were measured with a Capintec CRC 15R dose calibrator. Solid-Phase Extraction Cartridge Methods The SPE cartridge used was the C 18 Sep Pak (P/N 20515; Waters). The general procedure was as follows. SIMPLIFIED METHOD FOR TESTING 99M TC-MAG3 Seetharaman et al. 179

TABLE 1 Comparison of SPE Methods for Determination of RCP of Tc-MAG3 Step European method American method Preparation 10 ml of ethanol, 10 ml of HCl at 1 mmol/l, and 5 ml of air 10 ml of ethanol, 10 ml of HCl at 1 mmol/l, and 5 ml of air Solution A 5 ml of HCl at 1 mmol/l and 5 ml of 0.5% 10 ml of HCl at 1 mmol/l (hydrophilic impurities) ethanol-phosphate buffer Solution B ( Tc-MAG3) 10 ml of 7% ethanol-phosphate buffer 10 ml of 1:1 ethanol:0.9% saline Lipophilic impurities 1 colloid 10 ml of ethanol Residue counted Prewet ( activate ) the cartridge with ethanol and then prepare the cartridge with preparation solvent. Place a drop of the radiopharmaceutical in the inlet of the cartridge. Elute sequentially with quantities of solution A and collect in a tube. Elute sequentially with quantities of solution B and collect in a second tube. Place the cartridge in a third tube for measurement of residual activity. Measure the activity in each tube in the dose calibrator. Calculate the RCP as the activity in fraction B divided by the total activity in all fractions. To determine the profile of elution from the cartridge, solution B was collected in four 2.5-mL fractions. Thin-Layer Chromatographic Method The standard instant thin-layer chromatographic (ITLC) method developed by Chen et al. (5) was compared with the new method. The method of Chen et al. (5) involves the use of 2 strips of instant thin-layer silica gel (ITLC-SG; Pall Gelman) as the stationary phase. The mobile phase for the first strip is freshly prepared ethyl acetate:butanone (3:2). The strip is cut at the midpoint, and the activity at the solvent front represents the hydrophilic impurities, primarily free pertechnetate and Tctartrate. The mobile phase for the second strip is 50% acetonitrile. The strip is cut at the quarter point, and the activity at the origin represents the reduced hydrolyzed technetium (colloid). Statistical analysis between groups was carried out by use of ANOVA with a significance level of P, 0.05. Specificity Experiments Tc-MAG3 was prepared at 2,000 MBq in a 4-mL quantity, and the RCP was determined with the 3 different SPE methods. The high-activity preparation already was established as being stable from previous work in this laboratory and was used to Preparation TABLE 2 Description of Simplified Method Step Solution A (hydrophilic impurities) Solution B ( Tc-MAG3) Lipophilic impurities 1 colloid Simplified method 5 ml of ethanol and 5 ml of HCl at 1 mmol/l 5 ml of HCl at 1 mmol/l 5 ml of 1:1 ethanol:water Residue counted reduce error attributable to the inability of the dose calibrator to read low activities. This procedure would determine whether the simplified method showed the same specificity for Tc-MAG3 and for hydrophilic and lipophilic impurities as the American and European methods. Linearity Experiments Known amounts of free pertechnetate were added to Tc- MAG3 preparations after boiling to produce various purities of Tc-MAG3. The RCP values of these solutions were tested with the simplified method to show its linearity over the expected working range of an analytic method. Accuracy and Precision The simplified method was evaluated for accuracy and precision by comparison against the standard ITLC method developed by Chen et al. (5) with impure mixtures prepared for linearity testing. Limits of Quantification and Limits of Detection Tests of limits of quantification and limits of detection are not required, as RCP values of less than 90% are not used in clinical studies, and the linearity response showed that RCP values of as low as 25% are detected and quantified. Robustness Robustness was evaluated by allowing other staff members to use the method and then determining the consistency of the results. RESULTS The ICH Q2B regulations state that validation of a new, simplified method needs to demonstrate the following: specificity, linearity, accuracy, precision, detection limit, quantitation limit, and robustness (4). Each was assessed individually as described below. Specificity Experiments Table 3 shows the average results of 6 individual experiments for each method along with the SDs. Two-factor ANOVA revealed no significant differences among the methods (n 5 18, F 17 5 2.67, P 5 0.118, not significant). Figure 1 shows that the amount of complex in the last 2 fractions was minimal and that the bulk was found in the first 2 fractions. Thus, the amount of solvent required to elute Tc-MAG3 was not as large as the SPCs suggest. The simplified method compared very well with the European and American SPE methods for determining the RCP. 180 JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY Vol. 34 No. 3 September 2006

TABLE 3 Comparison of Distribution of Radioactivity Determined by 3 SPE Methods Fraction European American Simplified Hydrophilic impurities fraction 1 fraction 2 fraction 3 fraction 4 Lipophilic impurities 1 colloid 4.33 6 0.73 5.24 6 0.89 3.54 6 1.78 74.36 6 6.10 68.44 6 5.00 87.47 6 2.97 17.45 6 6.48 20.42 6 4.28 7.70 6 1.84 1.81 6 0.41 3.06 6 1.71 NA 1.03 6 0.28 1.52 6 0.59 NA 1.03 6 0.28 1.32 6 0.40 1.29 6 0.36 Each value is mean 6 SD percentage (n 5 6). NA 5 not applicable. Linearity Experiments The measured RCP was plotted against the nominal RCP and analyzed by linear regression with the method of least squares. In 6 independent experiments, the r 2 values were 0.9917, 0.9868, 0.9990, 0.9926, 0.9926, and 0.9966. The results showed very good correlation with each other (mean, 0.9932; SD, 0.0039). These data showed that the linearity criteria stated in the ICH guidelines were met. Accuracy and Precision As shown in Figure 2, there was excellent agreement between the 2 methods. Single-factor ANOVA revealed no FIGURE 2. Relationship between ITLC method and simplified SPE method. significant difference (n 5 18, F 17 5 4.67 10 29, P 5 1.0, not significant). The slope of the regression line was 1.0025, and the intercept was 0.0863, indicating no systematic difference between the 2 methods and confirming the accuracy of the new method. The coefficients of variation for triplicate measurements were 0.06% for the new method and 0.18% for the ITLC method, indicating similar degrees of precision of the 2 methods. Limits of Quantification and Limits of Detection The dose calibrator can detect activities as low as 0.05 MBq, providing assurance that the new method can be used to detect low traces of activity and thus RCP. Robustness The results of further experiments performed by other radiopharmacy staff members indicated that the new method was robust. FIGURE 1. Distribution of Tc-MAG3 in 2.5-mL fractions of solution B. Error bars indicate SDs. DISCUSSION Preparation of Tc-MAG3 involves adding Tcpertechnetate to a kit containing a lyophilized mixture of S-benzoylmercaptoacetyltriglycine (betiatide, active ingredient precursor), sodium tartrate (weak chelating agent), and stannous chloride (reductant) (the American formulation also contains lactose as a bulking agent to aid in lyophilization) and heating for 10 min in a boiling water bath. Upon the addition of pertechnetate to the kit, a weak intermediate, Tc-tartrate, forms and is transchelated to MAG3 as the S-benzoyl protecting group is cleaved during heating. The specification of a minimum acceptable RCP varies with different sources. The European Pharmacopoeia specifies 94% bound, determined by a combination of HPLC SIMPLIFIED METHOD FOR TESTING 99M TC-MAG3 Seetharaman et al. 181

and thin-layer chromatography (for the measurement of colloid). The European SPC specifies a limit of 96% initially and 95% after 4 h with the HPLC method, whereas the European and American SPCs both specify a limit of 90% with the SPE cartridge method, although the methods are different. The European SPC specifies 2 preparation volumes with different activity limits and shelf lives: 1,110 MBq in 10 ml, with a 4-h expiration, and 925 MBq in 4 ml, with a 1-h expiration. The first volume has an equivalent concentration of 111 MBq/mL, and the second has a concentration of 231 MBq/mL. These data lead to issues concerning the concentration effects of Tc-MAG3 and eluate volumes. Work done by Millar and O Brien (6) showed that a preparation containing 1,110 MBq in 10 ml is stable for at least 6 h, whereas Vinberg (2) prepared Tc-MAG3 with up to 3,000 MBq in 4 ml and reported acceptable stability over 8 h. The present work suggests that concentrations of 200 and 500 MBq/mL can be prepared without adverse effects on RCP or stability. Taken together, these results suggest that the Tc-MAG3 complex is more stable than indicated in the SPC. The shorter shelf life of the 4-mL preparation in the European SPC may be based on work by Shattuck et al. (7), who found a lower initial RCP for 5-mL preparations than for 10-mL volumes, although there was no difference in stability. For determination of the RCP of SPE cartridges are regarded as an inexpensive, easy, and rapid alternative to the HPLC method; in fact, the European SPC describes both methods, although with different limits for acceptable RCP values, as noted above. Work done by Murray et al. (8) showed that the SPE method described in the European SPC yielded consistently lower RCP values than the HPLC method. Vinberg (2) also found that the RCP values were lower with the SPE method than with the HPLC method, with the major impurity being found in the hydrophilic fraction. Hepplewhite and Hesslewood (9) directly compared the European and American SPE methods for both formulations and found a significant difference in the results, with the results from the American method being 4.5% higher. The elution rate of the SPE cartridge also was important; indeed, this property was crucial if valid results were to be obtained, with slower elution rates yielding higher RCP values. An elution rate of 1.5 ml/min was found to be the maximum limit (2). Thus, 10 ml of eluent would require 6.7 min, which is a significant amount of time in a busy radiopharmacy. The widely used ITLC method developed by Chen et al. (5) is not without problems of its own. Murray et al. (10) found that the ITLC method yielded consistently higher RCP values than the HPLC method because of its inability to differentiate lipophilic impurities from bound Tc- MAG3; however, they regarded this result as being acceptable because the difference was predictable and could be used to assess the RCP with suitably tighter acceptance criteria. Other problems with the ITLC method include inconsistent spot size and the frequency of artifacts. Murray et al. also found that the SPE method potentially could yield misleading results because the solvent designed to remove hydrophilic impurities also could remove a portion of bound Tc-MAG3. This problem was found to be highly variable, which means that the effect could not be predicted and considered. In contrast, Millar and Hesslewood (1) found that the results obtained with the SPE and HPLC methods correlated very well, although they recognized the weakness inherent in the SPE method, namely, the inability to differentiate among the compounds in each eluted fraction. The SPE system relies on the partitioning characteristics of hydrophilic impurities, and lipophilic impurities to separate these compounds in the SPE cartridge, and there is no practical way of checking this separation except by analyzing each fraction with a discerning method such as HPLC. The simplified method developed in the present work appears to show very good correlation with both of the approved SPE methods and with the ITLC method, although this method has yet to be compared with HPLC. It is clear that an SPE method with a solvent system designed to separate bound Tc-MAG3 and hydrophilic and lipophilic impurities is required. It also needs to be user-friendly and thus prevent errors during elution from overenthusiastic operators. Finally, to comply with the ICH Q2B regulations, the method needs to be validated in terms of the parameters described above. Our method has been simplified in terms of solvents and volumes, making it quick and easy for radiopharmacies to set up and use. The system is summarized in Table 2. The results obtained (Table 3; Fig. 1) show that the 3 SPE methods are comparable. To evaluate the potential for reducing elution volumes, the European and American SPE methods were performed with 10-mL eluates collected in four 2.5-mL fractions. Although there did appear to be some variation in when Tc-MAG3 was eluted from the cartridge, the results showed that virtually all of the Tc- MAG3 was eluted within the first 2 fractions (5 ml). This finding allows a reduction in elution volumes in the simplified method without compromising the results and in turn reduces the time required. When impure mixtures were prepared by the addition of pertechnetate to a linear relationship was observed between nominal RCP values for Tc-MAG3 over the range of 0% 100% and the apparent RCP obtained with the simplified method. Accuracy and precision were determined by comparison with the standard ITLC method developed by Chen et al. (5). The results showed that the simplified SPE method was comparable to the ITLC method. The SDs were small, suggesting that the methods were precise, and the means were similar, showing accuracy of the results. Thus, within the limits of the small sample size, the requirements of the ICH Q2B regulations were fulfilled. In particular, the high correlation between the simplified SPE method and the ITLC method provides confidence in the results. 182 JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY Vol. 34 No. 3 September 2006

CONCLUSION The simplified SPE method meets the requirements of the ICH Q2B regulations and produces results equivalent to those provided by the approved SPE methods in the SPCs and the standard ITLC method but is more rapid to perform, with a corresponding reduction in solvent usage. REFERENCES 1. Millar AM, Hesslewood SR. A comparison of SepPak and high-performance liquid chromatography as techniques for measuring the radiochemical purity of Tc-MAG3. Nucl Med Commun. 2004;25:1049 1051. 2. Vinberg N. Tc-MAG3: problems with radiochemical purity testing [letter]. Nucl Med Commun. 2000;21:869 870. 3. Ponto JA. Effect of solvent flow rate in mini-column testing of Tc-mertiatide. J Nucl Med Technol. 2005;33:232 233. 4. International Commission on Harmonisation. Validation of Analytical Procedures: Methodology (Q2B). Geneva, Switzerland: ICH Secretariat; 1996. 5. Chen F, Decristoforo C, Rohrbacher B, Riccabona G. A simple two-strip method to determine the radiochemical purity of technetium- mercaptoacetyltriglycine. Eur J Nucl Med. 1993;20:334 338. 6. Millar AM, O Brien LM. Preparation of Tc-MAG3: no confirmation that sodium chloride injections from plastic containers affect radiochemical purity. Nucl Med Commun. 1998;19:475 477. 7. Shattuck LA, Eshima D, Taylor AT, et al. Evaluation of hepatobiliary excretion of Tc-MAG3 and reconstitution factors affecting radiochemical purity. J Nucl Med. 1994;35:349 355. 8. Murray T, McKellar K, Owens J, Watson WS, Hilditch TE, Elliott AT. Tc- MAG3: problems with radiochemical purity testing. Nucl Med Commun. 2000;21: 71 75. 9. Hepplewhite J, Hesslewood S. Radiochemical purity determination of Tc- MAG3: comparison of two Sep-Pak procedures [abstract]. Nucl Med Commun. 1996;17:993. 10. Murray T, Hilditch T, Owens J. Tc-MAG3: problems with radiochemical purity testing author s reply [letter]. Nucl Med Commun. 2000;21:870. SIMPLIFIED METHOD FOR TESTING 99M TC-MAG3 Seetharaman et al. 183