DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE RUBBER SHAKES REPORT HOLDER: DAVINCI ROOFSCAPES, LLC

Similar documents
DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOF PANELS REPORT HOLDER: ONDULINE NORTH AMERICA, INC. EVALUATION SUBJECT:

REPORT HOLDER: RARE MANUFACTURING INC A AVENUE SURREY, BRITISH COLUMBIA V4N 4P2 CANADA EVALUATION SUBJECT: IRONWOOD SHAKE

REPORT HOLDER: FEROOF CO., LTD SEONWON LI SEONNAM MYEON SUNGJU GUN KYEONGSANGBUK DO SOUTH KOREA EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL SHINGLES REPORT HOLDER: TEFUTE BUILDING MATERIALS COMPANY, LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: ROOF PANELS REPORT HOLDER: ROSER CO., LTD.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF TILES REPORT HOLDER: GERARD ROOFING TECHNOLOGIES EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CLAY ROOF TILES REPORT HOLDER: CERAMICA LA ESCANDELLA, S.A.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CONCRETE ROOF TILES REPORT HOLDER: BARTILE ROOFS, INC. EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: METAL SALES MANUFACTURING CORPORATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING FELT AND UNDERLAYMENT REPORT HOLDER: ENVIRONMENTALLY SAFE PRODUCTS, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CLAY ROOF TILES REPORT HOLDER: BORAL ROOFING LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: METAL SALES MANUFACTURING CORPORATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CLAY ROOF TILES REPORT HOLDER: TEJAS BORJA USA EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FACED PANELS REPORT HOLDER: MEXALIT INDUSTRIAL, S.A. DE C.V.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: CERTAINTEED CORPORATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CONCRETE ROOF TILES REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: GENTEK BUILDING PRODUCTS, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: KAYCAN LTD.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: KP BUILDING PRODUCTS

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: EVALUATION SUBJECT: STRUCTURAL PANELS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: RIDGE VENTS REPORT HOLDER: VERSCENE, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: DERBY BUILDING PRODUCTS INCORPORATED

REPORT HOLDER: LOUISIANA-PACIFIC CORPORATION 414 UNION STREET, SUITE 2000 NASHVILLE, TENNESSEE EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: MODIFIED BITUMINOUS SHEET ROOFING REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIBER CEMENT SIDING REPORT HOLDER: KMEW CO., LTD. EVALUATION SUBJECT:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: ENERCEPT, INC.

ICC-ES Report OR-4, AND MOISTURE DIVISION: SECTION: SECTION: Reissued 11/2017 This. Report Holder:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: SIDING REPORT HOLDER: BORAL COMPOSITES, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS/WEATHER BARRIERS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIBER CEMENT SIDING REPORT HOLDER: RIEDER FASERBETON ELEMENTE GmbH

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: SIDING REPORT HOLDER: SHAKERTOWN 1992, INC.

REPORT HOLDER: HUBER ENGINEERED WOODS, LLC ONE RESOURCE SQUARE DAVID TAYLOR DRIVE, SUITE 300 CHARLOTTE, NORTH CAROLINA 28262

ESR-2015P* Reissued April 2014 This report is subject to renewal April 1, 2015.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP FABRICATED WOOD TRUSSES REPORT HOLDER: BARRETTE STRUCTURAL DISTRIBUTION, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CONCRETE ROOF TILES REPORT HOLDER: BORAL ROOFING EVALUATION SUBJECT:

REPORT HOLDER: SOPREMA, INC. 310 QUADRAL DRIVE WADSWORTH, OHIO EVALUATION SUBJECT:

DIVISION: OPENINGS SECTION: UNIT SKYLIGHTS REPORT HOLDER: SKYCO SKYLIGHTS 2995 AIRWAY AVENUE, SUITE B COSTA MESA, CALIFORNIA 92626

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PLASTICS SECTION: PLASTIC DECKING REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL WALL PANELS REPORT HOLDER: FCP, INC.

STRENGTH AND DURABILITY OF THE INSTALLED STONE

REPORT HOLDER: BASF CORPORATION EVALUATION SUBJECT: MASTERSEAL AWB 660 I VAPOR RETARDER, AIR AND WATER-RESISTIVE BARRIER AND FLEXIBLE FLASHING

REPORT HOLDER: MASTER MARK PLASTICS PRODUCTS 210 AMPE DRIVE PAYNESVILLE, MINNESOTA EVALUATION SUBJECT:

ICC-ES Evaluation Report. ESR-3297 Reissued March 1, 2013 This report is subject to renewal May 1, 2014.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: 3A COMPOSITES USA INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: FUNDERMAX GMBH

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: PRODEMA USA INC. EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: PARKLEX USA

ESR-3284 Reissued August 1, 2011 This report is subject to renewal August 1, 2013.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: FOUR SEASONS SOLAR PRODUCTS

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD I JOISTS REPORT HOLDER: STARK TRUSS COMPANY, INC.

ICC ES SYSTEM SYSTEM. Trusted DIVISION: 07 SECTION: AND FINISH REPORT HOLDER: ICC-ES Evaluation. Reissued 08/2016.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PLASTICS SECTION: PLASTIC RAILINGS REPORT HOLDER: FYPON, LTD.

ESR-1013 Reissued January 1, 2012 This report is subject to renewal in two years.

ESR-2894 Reissued April 2014 This report is subject to renewal April 1, 2016.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: NAILS REPORT HOLDER: HY-TEK FASTENERS INC. EVALUATION SUBJECT: HY-TEK NAILS

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: PLASTIC DECKING SECTION: PLASTIC RAILINGS REPORT HOLDER:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: NAILS REPORT HOLDER: BOSTITCH FASTENING SYSTEMS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS SECTION: AIR BARRIERS

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PLASTICS SECTION: PLASTIC DECKING REPORT HOLDER:

REPORT HOLDER: UNITED DURALUME PRODUCTS, INC. EVALUATION SUBJECT: DURACOOL COMPOSITE STRUCTURAL INSULATED PANELS

DIVISION: OPENINGS SECTION: UNIT SKYLIGHTS REPORT HOLDER: KINGSPAN LIGHT + AIR LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: ASSOCIATED MATERIALS, INC.

DIVISION: MASONRY SECTION: MANUFACTURED BRICK MASONRY SECTION: MANUFACTURED STONE MASONRY REPORT HOLDER:

REPORT HOLDER: R.L. ADAMS PLASTICS, INC CROSSROADS COMMERCE PARKWAY WYOMING, MICHIGAN EVALUATION SUBJECT: POLYCORE BRAND INSULATION

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER:

EMPIRE SHAKE, EMPIRE PLUS SHAKE, AND EMPIRE SLATE POLYOLEFIN COMPOSITE TILES

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP FABRICATED WOOD TRUSSES REPORT HOLDER: BARRETTE STRUCTURAL DISTRIBUTION, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: EXTERIOR INSULATION AND FINISH SYSTEMS REPORT HOLDER: DRYVIT SYSTEMS, INC.

REPORT HOLDER: GEORGIA PACIFIC GYPSUM LLC 2861 MILLER ROAD DECATUR, GEORGIA EVALUATION SUBJECT: DENSELEMENT BARRIER SYSTEM

DIVISION: METALS SECTION: METAL FABRICATIONS REPORT HOLDER: AKRON PRODUCTS COMPANY

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: SIDING SECTION: FACED PANELS REPORT HOLDER:

REPORT HOLDER: PAREX USA, INC EAST LA PALMA AVENUE, SUITE 250 ANAHEIM, CALIFORNIA EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING AND SIDING PANELS REPORT HOLDER: KINGSPAN INSULATED PANELS, INC.

REPORT HOLDER: STAR R FOAM MANUFACTURING, INC. EVALUATION SUBJECT: STAR R FOAM INSULATION BOARDS

DIVISION: FINISHES SECTION: GYPSUM BOARD ACCESSORIES REPORT HOLDER: CONLAB, INC. dba PREST ON CO.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: TRESPA NORTH AMERICA, LTD.

DIVISION: METALS SECTION: METAL FABRICATIONS REPORT HOLDER: QUALITY WAY PRODUCTS, LLC 407 HADLEY STREET HOLLY, MICHIGAN 48442

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH 5000 SERIES FASTENERS

Joint Evaluation Report ICC-ES (800) (562)

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PLASTICS REPORT HOLDER: INTEPLAST GROUP CORPORATION EVALUATION SUBJECT:

DIVISION: FINISHES SECTION: GYPSUM BOARD ACCESSORIES REPORT HOLDER: GRABBER NAILS FOR GYPSUM WALLBOARD INSTALLATION

REPORT HOLDER: OMEGA PRODUCTS INTERNATIONAL, INC CALIFORNIA AVENUE CORONA, CALIFORNIA EVALUATION SUBJECT:

DIVISION: METALS SECTION: METAL FASTENINGS REPORT HOLDER: GRABBER CONSTRUCTION PRODUCTS, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: REFLECTIX INCORPORATED

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER: MITEK USA, INC.

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH 3000 SERIES FASTENERS

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PLASTICS SECTION: PLASTIC DECKING REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS REPORT HOLDER: PAREX USA, INC.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PLASTICS SECTION: PLASTIC DECKING REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PEDESTRIAN TRAFFIC COATINGS REPORT HOLDER: HILL BROTHERS CHEMICAL COMPANY

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: PLASTIC DECKING SECTION: PLASTIC RAILINGS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL WALL PANELS REPORT HOLDER: METL SPAN, A DIVISION OF NCI GROUP, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL WALL PANELS DIVISION: SIDING REPORT HOLDER: VM ZINC

DIVISION: CONCRETE SECTION: CONCRETE ACCESSORIES SECTION: REINFORCING STEEL REPORT HOLDER: SRL INDUSTRIES LTD.

DIVISION: FINISHES SECTION: SUSPENSION SYSTEMS SECTION: ACOUSTICAL CEILING SUSPENSION ASSEMBLIES REPORT HOLDER:

REPORT HOLDER: HUBER ENGINEERED WOODS, LLC ONE RESOURCE SQUARE DAVID TAYLOR DRIVE, SUITE 300 CHARLOTTE, NORTH CAROLINA 28262

Transcription:

0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-2119 Reissued 08/2017 This report is subject to renewal 08/2019. DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION SECTION: 07 31 33 COMPOSITE RUBBER SHAKES REPORT HOLDER: DAVINCI ROOFSCAPES, LLC 13890 WEST 101 ST STREET LENEXA, KANSAS 66215 EVALUATION SUBJECT: DAVINCI SLATE, DAVINCI SHAKE, BELLAFORTÉ SHAKE, AND BELLAFORTÉ SLATE ROOF SHINGLES Look for the trusted marks of Conformity! 2014 Recipient of Prestigious Western States Seismic Policy Council (WSSPC) Award in Excellence A Subsidiary of ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright 2017 ICC Evaluation Service, LLC. All rights reserved.

ICC-ES Evaluation Report www.icc-es.org (800) 423-6587 (562) 699-0543 ESR-2119 Reissued August 2017 This report is subject to renewal August 2019. A Subsidiary of the International Code Council DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION Section: 07 31 33 Composite Rubber Shakes REPORT HOLDER: DaVINCI ROOFSCAPES, LLC 13890 WEST 101 ST STREET LENEXA, KANSAS 66215 (913) 599-0766 www.davinciroofscapes.com EVALUATION SUBJECT: DaVINCI SLATE, DaVINCI SHAKE, BELLAFORTÉ SHAKE, AND BELLAFORTÉ SLATE ROOF SHINGLES 1.0 EVALUATION SCOPE 1.1 Compliance with the following codes: 2012, 2009 and 2006 International Building Code (IBC) 2012, 2009 and 2006 International Residential Code (IRC) 1997 Uniform Building Code (UBC) 2013 Abu Dhabi International Building Code (ADIBC) The ADIBC is based on the 2009 IBC. 2009 IBC code sections referenced in this report are the same sections in the ADIBC. Properties evaluated: Weather resistance Fire classification Wind resistance 1.2 Evaluation to the following green code: 2016 California Green Building Standards Code (CALGreen), Title 24, Part 11 Attributes verified: See Section 3.1 2.0 USES The DaVinci Slate, DaVinci Shake, Bellaforté Shake, and Bellaforté Slate roof shingles are used as roof covering materials and are recognized as a Class A roof covering when installed in accordance with this report. 3.0 DESCRIPTION 3.1 General: The DaVinci Slate, DaVinci Shake, Bellaforté Shake, and Bellaforté Slate roof shingles are engineered polymeric-based roof shingles designed to provide the look of natural slate or shake, respectively. The shingles are manufactured with a proprietary formulation using both high-density and low-density polyethylene polymers and other additives. The attributes of the roof tiles have been verified as conforming to the provisions of CALGreen Section A5.406.1.2 for reduced maintenance. Note that decisions on compliance for those areas rest with the user of this report. The user is advised of the project-specific provisions that may be contingent upon meeting specific conditions, and the verification of those conditions is outside the scope of this report. These codes or standards often provide supplemental information as guidance. 3.2 DaVinci Slate Roof Shingle: The DaVinci Slate roof shingle is available in various colors and in widths of 6, 7, 9, 10 and 12 inches (152, 178, 229, 254 and 305 mm) with a length of 18 inches (457 mm). Exposure is 6 to 7 1 / 2 inches (152 to 191 mm), resulting in an installed weight of 325 to 260 pounds, respectively, per 100 square feet (15.9 to 12.7 kg/m 2 ). See Figure 1 [10-inch- and 12-inch-wide (254 and 305 mm) shingles shown] for further details. 3.3 DaVinci Shake Roof Shingle: The DaVinci Shake roof shingle is available in various colors and in widths of 4, 6, 7, 8 and 9 inches (102, 152, 178, 203 and 229 mm) with a length of 22 inches (559 mm). Exposure is 9 to 10 inches (229 to 254 mm), resulting in an installed weight of 324 to 288 pounds, respectively, per 100 square feet (15.8 to 14 kg/m 2 ). See Figure 1 [9-inch-wide (229 mm) shingle shown] for further details. 3.4 Bellaforté Shake: The Bellaforté Shake roof shingle is available in various colors and in a width of 12.75 inches (324 mm) and a length of 16.25 inches (413 mm). Exposure is 12 inches (305 mm), resulting in an installed weight of 182 pounds per 100 square feet (8.9 kg/m 2 ). See Figure 2 for further details. 3.5 Bellaforté Slate: The Bellaforté Slate roof shingle is available in various colors and in a width of 11 5 / 8 inches (295 mm) and a length of 15 1 / 2 inches (394 mm). Exposure is 12 inches (305 mm), resulting in an installed weight of 170 pounds per 100 square feet (8.3 kg/m 2 ). See figure 2 for further details. 3.6 Underlayment: Underlayment must be a minimum of one layer of either Type II (No. 30) asphalt-saturated organic felt, complying with ASTM D226; or GAF Versashield Fire-Resistant Roof Deck Protection recognized in ICC-ES ESR-2053, unless ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright 2017 ICC Evaluation Service, LLC. All rights reserved. Page 1 of 4

ESR-2119 Most Widely Accepted and Trusted Page 2 of 4 noted otherwise in this report. Where an ice barrier is required as noted in Section 4.2 of this report, an ICC-ES evaluation report indicating the membrane s compliance with requirements of the ICC-ES Acceptance Criteria for Self-adhered Roof Underlayments for Use as Ice Barriers (AC48) must be submitted to the code official. 3.7 Flashing: Flashing must be minimum 16-oz/ft 2 (No. 23 gage) copper or other corrosion-resistant metal with a thickness of not less than 0.019 inch (0.483 mm). See Section 4.5 for valley flashing. 3.8 Fasteners: No. 12 gage corrosion-resistant roofing nails with 3 / 8 -inchdiameter (9.5 mm) heads must be used to fasten the ASTM D226 Type II underlayment to the sheathing. Nails must have sufficient length to penetrate into the sheathing 3 / 4 inch (19 mm) or through the sheathing, whichever is less. Fasteners used to attach GAF Versashield Fire Resistant Roof Deck Protection must be as described in ESR-2053. No. 12 gage, ring-shank, corrosion-resistant nails must be used to secure flashing to the sheathing. Nails must be compatible with the flashing material, and have sufficient length to penetrate the sheathing 3 / 4 inch (19 mm) or through the sheathing, whichever is less. To secure the roof shingles to the sheathing, 1 1 / 2 -inchlong-by- 1 / 8 -inch-diameter-shank (38 mm by 3.18 mm) hot-dipped galvanized roofing nails, with 3 / 8 -inch-diameter (9.5 mm) heads, must be used. 4.0 INSTALLATION 4.1 General: The roof shingles must be installed in accordance with this report, the applicable code and the manufacturer s published installation instructions. The manufacturer s installation instructions must be available at the jobsite at all times during installation. The shingles must be installed on roofs with solid sheathing and a minimum slope of 3:12 (25 percent slope). Solid sheathing must be minimum 15 / 32 -inchthick (11.9 mm) exterior-grade plywood, 7 / 16 -inch-thick (11.1 mm) oriented strand board (OSB), or nominally 1-inch-thick (25.4 mm) lumber. The sheathing must be structurally adequate and fastened to resist the wind loads as specified by IBC and UBC Section 1609, or IRC Section R301.2, for components and cladding. 4.2 Underlayment: Underlayment described in Section 3.6 is installed parallel to the roof eave with a 6-inch (152 mm) lap on the ends, a 6-inch (152.4 mm) side lap and a minimum 6-inch (152 mm) lap over eaves. The underlayment is fastened, only as necessary to hold in place. In areas where the average daily temperature in January is 25 F (-4 C) or less, or where there is a possibility of ice forming along the eaves and causing a backup of water, an ice barrier as described in Section 3.6, in addition to the underlayment, is required on all eaves, valleys, and gable ends, and around roof projections. At roof eaves, the ice dam membrane must extend from the eave s edge to a point 24 inches (610 mm) inside the exterior wall line of the building. 4.3 Roof Shingles: 4.3.1 DaVinci Slate and DaVinci Shake Roof Shingles: Starting with a row of 12-inch-wide (305 mm) DaVinci Starter Slates or Shakes, the shingles must extend approximately 1 inch (25.4 mm) over the eaves and 3 / 4 inch (19 mm) over the rakes. The shingles are secured to the sheathing using two fasteners, as noted in Section 3.8, through the premolded nail markers. The field shingles must be installed flush with the starter slate or shake shingles on the outer and lower edges. A maximum gap of 3 / 8 inch (9.5 mm) is recommended between shingles, with a minimum 1 / 4 -inch (6.4 mm) gap required. The gaps between shakes at adjacent courses must be offset a minimum of 1 1 / 2 inches (38 mm). The maximum allowable exposure is 7 1 / 2 inches (191 mm) for Slateroof shingles, and 10 inches (254 mm) for Shake roof shingles. 4.3.2 Bellaforté Shake and Bellaforté Slate Roof Shingles: Bellaforté Shake (12.75 inches wide [324 mm]) or Bellaforté Slate (11 5 / 8 inches wide (295 mm)) must be installed on top of starter tiles and must extend approximately 1 inch (25.4 mm) over the eaves. The shingles are secured to the sheathing using three fasteners as noted in Section 3.8, two through the premolded nail markers and one through the tab. The field shingles must be installed flush with the starter slate or shake shingles on the lower edges. 4.4 Hips and Ridges: 4.4.1 General: The top of hips and ridges must be covered with a minimum 6-inch-wide (152 mm) flashing as noted in Section 3.7. 4.4.2 DaVinci Slate Roof Shingles: On top of the flashing, 76-inch-wide (178 152 mm) or 7-inch-wide (178 mm) DaVinci Slate roof shingles are installed on each side of hips and ridges, with the shingles butting at the top. Both hip and ridge shingles must be installed with a 6-inch (152 mm) exposure. Shingles and flashing must be secured with fasteners as noted in Section 3.8. 4.4.3 DaVinci Shake Roof Shingles: On top of the flashing, 6-inch-wide (152 mm) DaVinci Shake roof shingles are installed on each side of hips and ridges, with the shingles butting at the top. Both hip and ridge shingles must be installed with a 10-inch (254 mm) exposure. Shingles and flashing must be secured with fasteners as noted in Section 3.8. 4.4.4 Bellaforté Shake: Bellaforté Shake one-piece hip and ridge tiles are installed at a 12-inch (305 mm) exposure. The tiles are nailed once on each side approximately 3 / 4 inch (19 mm) from the outside edge and 12 1 / 2 inches (305 mm) from the butt of the tile. Shingles and flashing must be secured with fasteners as noted in Section 3.8. 4.4.5 Bellaforté Slate: Bellaforté Slate one piece hip and ridge tiles are installed at a 12-inch (305 mm) exposure. The tiles are nailed once on each side approximately 3 / 4 inches (19 mm) from the outside edge and 12 1 / 2 inches (318 mm) from the butt of the tile. Shingles and flashing must be secured with fasteners as noted in Section 3.8. 4.5 Valleys: Valleys must be flashed in accordance with 2009 IBC Section 1507.7.7, 2006 IBC Section 1507.7.6, IRC Section R905.6.6 or UBC Section 1508.4, as applicable, and the manufacturer s published installation instructions, using the flashing and fasteners described in Sections 3.7 and 3.8, respectively. 4.6 Fire Classification: The roof shingles comply with IBC Section 1505.2, IRC Section R902.1 and UBC Standard 15-2 as a Class A roof

ESR-2119 Most Widely Accepted and Trusted Page 3 of 4 covering, when installed in accordance with Section 4.6.1, 4.6.2, 4.6.3, or 4.64: 4.6.1 DaVinci Slate Roof Shingles: When the shingles are installed with a maximum 6-inch (152 mm) exposure, the underlayment must be either a minimum of one layer of Type II (No. 30) asphalt-saturated organic felt, complying with ASTM D226; or a minimum of one layer of GAF Versashield Fire-Resistant Roof Deck Protection as recognized in ESR-2053. When the shingles are installed with a maximum exposure of 7 1 / 2 inches (191 mm), the underlayment must be a minimum of one layer of the GAF product mentioned above. 4.6.2 DaVinci Shake Roof Shingles: The underlayment must be a minimum of one layer of GAF Versashield Fire- Resistant Roof Deck Protection as recognized in ESR-2053. 4.6.3 Bellaforté Shake: When the shakes are installed with a maximum 12-inch (304 mm) exposure, the underlayment must be a minimum of one layer of Type II (No. 30) asphalt-saturated organic felt complying with ASTM D226, plus one layer of mineral-surfaced cap sheet complying with ASTM D3909. 4.6.4 Bellaforté Slate: When the shingles are installed with a maximum 12-inch (305 mm) exposure, the underlayment must be a minimum of two layers of Type II, (No. 30) asphalt-coated glass-fiber-mat, complying with ASTM D226. 4.7 Wind Resistance: 4.7.1 DaVinci Roof Shingles: The DaVinci Slate and DaVinci Shake roof shingle system described in Section 3.0 and installed in accordance with Sections 4.1 through 4.5 has an allowable wind uplift resistance of 50 pounds per square foot (2.39 kpa). 4.7.2 Bellaforté Shake Roof Shingle: 4.7.2.1 2012 IBC: When installed in accordance with this report, the Bellaforté Shake roof shingle system is limited to areas subject to a maximum ultimate design wind speed (V ult ) of 130 mph (209 km/h) in accordance with 2012 IBC Figure 1609, on structures having a maximum mean roof height of 40 feet (12.2 m). 4.7.2.2 2009 and 2006 IBC: When installed in accordance with this report, the Bellaforté Shake roof shingle system is limited to areas subject to a maximum basic wind speed of 100 mph (161 km/h) in accordance with 2009 or 2006 IBC Figure 1609, as applicable, on structures having a maximum mean roof height of 40 feet (12.2 m). 4.7.2.3 IRC: When installed in accordance with this report, the Bellaforté Shake roof shingle system is limited to areas subject to a maximum basic wind speed of 100 mph (161 km/h) in accordance with 2012 IRC Figure R301.2(4)A, or 2009 or 2006 IRC Figure R301.2(4), as applicable, on structures having a maximum mean roof height of 40 feet (12.2 m). 4.7.3 Bellaforté Slate Roof Shingles: The Bellaforté Slate roof shingle system described in Section 3.0 and installed in accordance with Sections 4.1 through 4.5 has an allowable wind uplift resistance of 75 pounds per square foot (11.2 kpa). 4.8 Reroofing: Prior to application of the shingles, the existing roof covering and underlayment must be completely removed. Any damaged sheathing must be replaced. The installation of the shingles must then proceed as described in Sections 4.1 through 4.5. An existing self-adhered ice barrier membrane may remain in place if covered with a new ice barrier membrane in accordance with the applicable code. The roof classification is as noted in Section 4.6 5.0 CONDITIONS OF USE The DaVinci Slate, DaVinci Shake, Bellaforté Shake, and Bellaforté Slate roof shingles described in this report comply with, or are suitable alternatives to what is specified in, those codes listed in Section 1.0 of this report, subject to the following conditions: 5.1 Installation must comply with the applicable code, the manufacturer s published installation instructions and this report. The instructions within this report govern if there are any conflicts between the manufacturer s installation instructions and this report. 5.2 The roof shingles are manufactured in Lenexa, Kansas, under a quality-control program with inspections by ICC-ES. 6.0 EVIDENCE SUBMITTED Data in accordance with the ICC-ES Acceptance Criteria for Special Roofing Systems (AC07), dated February 2014 (editorially revised May 2016). 7.0 IDENTIFICATION Each roof shingle is labeled with the report holder s name (DaVinci Roofscapes, LLC) and address, the product name, the shingle width, a production date code, and the ICC-ES evaluation report number (ESR-2119).

ESR-2119 Most Widely Accepted and Trusted Page 4 of 4 For SI: 1 inch = 25.4 mm. NOTE: Narrower shingles similar FIGURE 1 DaVINCI SLATE ROOF SHINGLES AND SHAKE ROOF SHINGLES FIGURE 2 BELLAFORTÉ SHAKE FIGURE 3 BELLAFORTÉ SLATE