ECHO FLOORS (PTY) LTD HOLLOW-CORE CONCRETE FLOORING A NAME TRULY CAST IN CONCRETE

Similar documents
A NAME TRULY CAST IN CONCRETE PRESTRESSED HOLLOW CORE CONCRETE FLOORS & WALLS

ECHO PRESTRESS DURBAN (PTY) LTD HOLLOW-CORE CONCRETE FLOORING A NAME TRULY CAST IN CONCRETE

PERFECT SLABS Bernie de Klerk

BISON PRECAST FLOORING SPECIFICATION

HOLLOW CORE FLOORS SPEED AND STRENGTH

Bison Precast Flooring Specification

Hollowcore Floors. The ideal structural floor solution for all building types in all sectors.

CONCRETE MANUFACTURERS ASSOCIATION - MEMBERSHIP LIST

Prestressed Hollowcore Slabs PRECAST CONCRETE SOLUTIONS.

STRESSLINE LIMITED LINTEL GUIDE JULY LINTEL GUIDE 2014

3.4.2 DESIGN CONSIDERATIONS

Lattice Plate Flooring

Portland HOLLOWCORE. The obvious choice

7. MATERIALS AND TECHNICAL INVESTIGATION

P.O Box. 457, P.C 124, Sultanate of Oman Tel / Fax: Mob:

SPECIFICATION FOR PRECAST/ COMPOSITE CONCRETE FLOORS/ ROOF DECKS SECTION E60

The difference is Guidance for the preparation of Deck Manufacturing Schedules

Shell Beams. Product brochure

ORAK PRECAST LIFELONG BUILDING HIGH QUALITY PRODUCTS DESIGN ENGINEERS SHORT TIME SCHEDULE PRODUCTION EXPERTS TRANSPORTATION FLEET REASONABLE PRICES

CHAPTER 8. Concrete Work

FORMDECK. constructions. constructions

Demidec. cornish concrete products Demidec Flooring and Permanent Formwork

Hollowcore Slabs. Hollowcore slabs are used mainly for flooring and roofing, but can also be used for wall purposes.

Multideck 146. Contents

Client Report : A design method for use with 6mm diameter Thor Helical twistfix wires used as retrofitted bedjoint reinforcement

Hollow Core Slabs in Construction Industry

Lysaght Bondek. Structural steel decking system Design and Construction Manual

155 & 220 Beam Flooring Systems

Civil Engineering Construction Chapter 5

A-BEAM W Erection Manual 2

Connection Design Assistance Manual

0331 Brick and block construction

Regulations Detail Sheet 1

Locrete Building System: the Technology Handbook

Metal Decking Specialists

Chapter 9 ALTERNATIVE TECHNOLOGIES

Technical Manual. The difference is.

Brick Works (cont.) Building in bricks: Factors affecting the stability of brick building: Properties of bricks:

1 BILL NO.1 PRELIMINARIES AND GENERAL MANIFESTATION.

Learning Objectives. A Brief History

CONCRETE TECHNOLOGY CORPORATION

A-BEAM S Erection Manual 2

Elite Garments Ind. Ltd.

GMS Composite Ltd. Shardagonj, Kashimpur,Gazipur,Bangladesh ( , ) 22 March 2014

GUIDE SPECIFICATIONS For STRUCTURAL PRECAST HOLLOW CORE SLABS SECTION 03410

COST COMPARISON DINCEL vs AAC WALLS

Flatslabs. Product brochure

FLOORING SYSTEMS GUIDE

NOTICE XX/2017 SUPPLY AND ERECT PRE-CAST CONCRETE PALISADE FENCING WITHIN THE KOUGA MUNICIPAL AREA

roofing ROOFING Design of the base ROOFING DETAILS

DECK DAMAGE AND PENETRATIONS

How to fill in your Timber Frame Order Form

Technical Notes on Brick Construction Brick Industry Association Commerce Park Drive, Reston, Virginia 20191


Interiors Sources Decor LLC. Method Statement BLOCK WORK. Civil Works 6/26/2016

beam - filler block floors beam floors prefabricated in full cross-section

PRESTRESSED AND PRECAST LINTELS for strength and value.

ARCHITECTS PACK

WARMFLOOR. Installation Guide.

PRE CAST CONCRETE LINTELS SILLS & COPINGS

Al Islam Textile Ltd.

Conditions of the Contract and Division 1 General Requirements are a part of this section.

Talk to us, THE SMART DECKING PEOPLE Visit or Global Roofing Solutions Bond-Dek Composite Deck

STEPPING STONES DAYCARE NEW LISKEARD PUBLIC SCHOOL

Chapter. Masonry Design

A. Coordinate concrete unit masonry (also termed CMU and block ) work with work before and after, especially:

Hale Allen Jones The Institution of Structural Engineers East Anglian Branch Award for Structural Excellence Submission

Concrete. Copyright: Quasar Management Services Pty Ltd

Amity Design Ltd. House #7&9, Road #9 Block #D, Section #11 Mirpur Dhaka 1216, Bangladesh (23.820N, E) 03.MARCH.2014

PROFESSIONAL FORMWORK SOLUTIONS

TECHNICAL INFORMATION SCREED

cornish concrete products Structural precast

PRESENTATION PLAN A MODEL COMPARISON FLOOR CONSTRUCTION

15/06/ Clippers Quay. Salford Manchester.

WARMFLOOR. Installation Guide.

Civil Engineering Construction I (CBE5031)

Purna Fashions Ltd. RH Attire Ltd

3151C COMFLOR COMPOSITE FLOOR SYSTEM

Hollow Core Slabs Applications

DATA SHEET 3 Concrete Masonry Lintels MARCH 2013

Analyze time-cost required for conventional and prefabricated building components

Prestressed Concrete Tanks. Design & Construction

TCC Systems. Timber-Concrete Composite TIMBER IMAGINEERING INNOVATIVE TIMBER SOLUTIONS

Wide slabs of reinforced concrete

WHATEVER THE CHALLENGE, PHILLIPS HAS YOU COVERED.

A. SYSTEM DETAILS A.1 Product Range

CI/SfB. (Ff2) June 2007 CIVIL E NGINEERING PRODUCTS STEPOC SYSTEM. innovators in masonry

These systems are evaluated on the basis of serviceability issues such as:

Part E robustdetails. robustdetails. January 2018 Update Pack

Cellular Lightweight Concrete Technical Specifications

Wide slabs of reinforced concrete

ALLOWABLE STRESS DESIGN OF CONCRETE MASONRY LINTELS. TEK 17-1C Structural (2009) Related TEK: Uniform load. Triangular load. Concentrated loads

IZODOM 2000 POLSKA Zduńska Wola, ul. Ceramiczna 2. tel , , tel./fax

SECTION STRUCTURAL PRECAST HOLLOW CORE SLABS

Structural Floor & Roof Systems

GAUTENG DEPARTMENT OF INFRUSTRUCTURE DEVELOPMENT

SPECIAL INSPECTION AND OBSERVATION PROGRAM City of Walnut Creek Building Division. Project Address:

BILL NO.1 PRELIMINARIES AND GENERAL MANIFESTATION.

CONCRETE TECHNOLOGY CORPORATION

robustdetails E-FC-7 Separating Floor Concrete Separating Floors Concrete E-FC-7

Transcription:

ECHO FLOORS (PTY) LTD HOLLOW-CORE CONCRETE FLOORING A NAME TRULY CAST IN CONCRETE

Introduction to Echo Floors The oldest company in the group, established in Gauteng in 1982. The core business is the manufacture and installation of precast reinforced hollow-core concrete slabs. Product quality and client satisfaction has always been important to Echo Floors hence our statement Committed to Quality, Committed to you. Echo Floors quality management systems has secured an ISO9001:2008 certification and the product is SABS approved. Echo Floors factory (2 facilities available) Echo Floors office block Typical applications of Echo Floors Echo reinforced hollow-core concrete slabs can be used for most types of buildings with short spans between load-bearing supports. Typical applications are residential - townhouses, clusters, new houses and house additions. The product is the preferred solution for affordable housing developments. Industrial and commercial application are also common, provided the spans do not exceed 6,8m between load-bearing supports. Echo slabs are also ideally suited in areas of heaving clay where suspended ground floors are required. The Echo precast slabs can be installed onto loadbearing brickwork, precast or in-situ beams or steel frames. High density housing developments 2 Individual houses / clusters Townhouses Affordable Housing Upmarket Residences Townhouses Light Industrial / Commercial

SERVICES OFFERED Echo Floors provide a complete service, from the professional design to the manufacture, delivery, installation and grouting of precast reinforced hollow-core slabs. Standard size: 900mm wide, 150mm deep and supplied in lengths of up to 8.2m in 100mm increments This service can include any or all of the following: Detailed layout drawing Design and engineer s certification Site measurement Supply only of slabs ex factory Full installation service Supply and installation of structural steel over openings (if necessary) Design Service The level of design service supplied by Echo may be specified by the client and/ or the Consulting Engineer. The Echo design service is provided by an independent Consulting Engineer. The Echo layout drawing service and engineer s certificate is included in our price. Slabs are supplied to suit as built dimensions which are checked by the Echo installation teams on site. Should you require Echo s independent engineer to design the foundations and structure the charge will be independent of Echo s quote. Installation The Echo panels are hoisted into position by a mobile or truck mounted crane. This means that sound and clear access to the building on which the slabs are to be erected is required. The installation of 600m2 per day per installation team is possible. Echo Floors use various size cranes depending on the site requirements and access available. Should a suspended slab be required inside an existing building, the entrance available must be a minimum 4,5m high x 3,0m wide provided there is sufficient turning space in front of the entrance for articulated trucks. Our standard cranes have a reach up to 13m with a 6m panel and 18m with a 3m panel. In order to obtain a flush ceiling finish on brickwork, the load bearing walls and internal walls must be level. Where the spans between the walls exceed 5,0m our slabs require a centre line of temporary propping for a minimum of 10 days after grouting the joints and structural topping / screeding is complete. The installation of Echo Floors is done by mobile or truck mounted crane. Props supplied by the client. Propping done by Echo s installation team. Grouting This service is also included in the price and is done by an in-house team. Echo grout the longitudinal joints between the slabs, not the ends nor the sides. This is a labour only service, all the materials are sourced from the site. Approximate quantities: 1m3 of riversand and 10 bags of cement per 100m2 of slab. A specification is available on request. Echo provide the labour for the grouting of longitudinal joints The conduiting is placed above the slab by the electrician prior to screeding or topping being poured by the contractor Mesh in screed / topping by the contractor 3

Echo Floors BASIC DESIGN PARAMETERS 1. 2. 3. 4. All clear spans 5.0m and over must be propped in the centre during the grouting of the joints. All clear spans over 5.0m require a structural topping cast on the slab (minimum 30MPa with 13mm stone). Props should be left in position for a minimum of 10 days after grouting and casting a topping. External walls at first floor level can be built while props are in position. Internal walls which are supported by the slab may only be constructed after props have been removed. 5. Openings up to 2 metres wide can be covered by 2 lintels side by side plus five courses of brickwork with brickforce in every course. This is suitable for the support of slabs up to 7.8m long. Openings wider than 2 metres should be referred to the engineer for the detailing of additional structural steel support. 6. Cantilevers up to 1.8m long can be done with Echo slabs with a structural topping and reinforcement. 7. Where Echo slabs are used as balconies, external walkways and flat roofs, we recommend a minimum reference 100 mesh in the screed/topping over the slabs. 8. The bearing of the Echo panel varies from 60-110mm depending on the type of support structure (masonry, steel or concrete). If the panels are installed into the flange of the beam a minimum 60mm bearing is required. 9. Echo Floors keep stock at all times, in lengths up to 8.2m Steel beam in 100mm increments. Standard width, 900mm and depth of 150mm. Echo slab resting inside 10. The slabs are cut to shape and size to suit the building. the beam flange 11. Maximum clear spans should not exceed 6.8m 110mm Prestressed lintel bearing pad Mortar 12. A 110mm prestressed lintel used as a bearing pad for a beam. The lintel is bedded into position with the same mortar used to build the wall. This must be done and cured prior to Echo placing the steel beam and slabs. 4

Echo Floors BASIC DESIGN PARAMETERS Downlights It s possible, it s simple and more economical than other systems, no matter what the electricians say. The fitting of downlights is a matter of coring holes through the slab, or using a hammer and chisel to form the required diameter hole. Coring is done once the slabs are placed into position and the downlight positions are marked. The result is accurately aligned lights. The cost per light point is also lower as single light transformers can be placed into the horizontal hollow-cores of the slab, instead of lightboxes. Conduits can be laid across the slab. They must be placed onto the slab before the contractor places the screed/topping. Echo provides the contractor with copies of the slab layout. The electrician can use the hollow-cores for the conduits, this eliminates unnecessary criss-crossing of conduits. We encourage the electricians to core in a straight line along the length of the panels which means only one structural rib is removed. Openings in Echo Floors Service holes up to 150mm diameter may be made in Echo slabs. Any service holes larger than 150mm should be referred to the Design Engineer to check the detail. We recommend that all service holes should be cut from the underside up. This minimises patching to the soffits of the units. Openings required for staircases or skylights are made with steel hangers which are supplied and erected by Echo Floors. Alternatively a steel/brick beam can be used as support around the opening. Refer to typical sections and details. Plastering of Echo Floors soffits Apply a mastic filler to the V joint of the ceiling. The mastic fill creates a permanent, malleable, crack free filler that remains flexible so that hairline cracks caused by thermal or other movement don t transfer to the skimmed soffits. Once this has been applied Echo recommend a bonding liquid be applied to the slab before skimming the ceiling with rhinolite. Finish off with a textured paint or good quality PVA Full specifications for both downlight placement and plastering of the soffits are available on www. echo.co.za click on Echo Floors Technical Details Structural Steel Beams Echo Floors use various steel sections to support the slabs over openings or to reduce span lengths or to carry walls above the slabs. The steel sections and applications vary to suit the requirements on site. Echo endeavour to use steel sections as unobtrusively as possible, by placing the panels into the beam flanges or by encasing the beam in the brickwork. 5

Echo Floors STRUCTURAL DETAILS Echo Floors structural details Echo Floors self weight & finishes / m2 Standard depth available Standard width Non Standard widths 150mm 900mm In 100mm increments Minimum concrete strength at 7 days Minimum concrete strength at 28 days Suggested maximum span/depth ratio 40MPa 50MPa Typical limiting L/30 for deflection Subject to Engineer s design 450MPa high tensile On brickwork100mm, concrete beams and steel beams 60mm Reinforcing type Minimum bearings Fire rating Slab only Slab and joint Slab joint and 40mm leveling screed Slab, joint and structural topping (50mm) (60mm) (70mm) (80mm) (90mm) (100mm) 2.65kN/m2 2.77kN/m2 3.73kN/m2 3.97kN/m2 4.21kN/m2 4.45kN/m2 4.69kN/m2 4.93kN/m2 5.17kN/m2 1 hour standard Higher ratings are possible when a 30MPa structural topping is applied Reinforcing content Slab Type Slab length Top steel (mm) Qty/Dia C 1000-3400 D 3500-3800 E 3900-4200 H 4300-4600 X 4700-7700 Z 7800 7 x ø8mm EK and EZ used over internal load - bearing walls - the maximum span between walls being 4000mm EK 5500-7400 EZ 7500-8200 7 x ø8mm Bottom steel Qty/Dia 5 x ø8mm 6 x ø8mm 8 x ø8mm 6 x ø12mm 9 x ø12mm 9 x ø12mm 8 x ø8mm 8 x ø8mm Ultimate moment of resistance table Resistance moment kn./m / metre width (per 1.0m width of slab) Total slab depth (mm) 150 200 Structural topping (mm) 0 50 Slab Type C 13.73 19.20 Slab Type D 16.40 22.93 Slab Type E/EK/EZ 21.64 30.29 Slab Type H 34.88 49.12 Slab Type X/Z 50.43 71.16 Total Weight kn/m2 2.77 3.97 6 210 60 20.32 24.28 32.07 52.14 75.69 4.21 220 70 21.44 25.61 33.78 55.16 80.21 4.45 230 80 22.56 26.94 35.64 58.17 84.74 4.69 240 90 23.68 28.30 37.43 61.19 89.27 4.93 250 100 24.79 29.64 39.22 64.21 93.78 5.17

TYPICAL SECTIONS AND DETAILS Refer to www.echo.co.za (click on Echo Floors Technical Details) 7

Echo Floors (Pty) Ltd Reinforced Hollow Core Floors Tel: 011 662 4600 Fax: 086 667 2037 Email: floors@echofloors.co.za Web: www.echo.co.za GPS: 25 59 56.6 S; 27 50 32.4 E LASTING VALUE OF CHOICE Plot 87 Of The Farm Driefontein Riverside Road Muldersdrift PO Box 706 Muldersdrift 1747 Echo Floors reserves the right to alter or change any of the details contained herein without prior notice. Echo Floors 2011. Designed and produced by Gartone Press.