OVERALL PERFORMANCE OF VENTILATED DOUBLE FAÇADES COMPARED TO A STATE OF THE ART SINGLE SKIN FAÇADE

Similar documents
An integral approach to façades: a conceptual comparison between different types of facades

Passive Heating Performance of different facade types

Monitoring of Advanced Facades and Environmental Systems

ADVANCED FAÇADES AND HVAC SYSTEMS: PRELIMINARY RESULTS OF FULL-SCALE MONITORING

Ventilated Illuminating Wall (VIW): Natural ventilation and daylight experimental analysis on a 1:1 prototype scale model

Analysis of different shading strategies on energy demand and operating cost of office building

The Elithis Tower is an experimental and demonstration. Elithis Tower in Dijon, France. nzeb case studies

171: An urban office designed for the southern Brazilian climate

BUILDING INTEGRATED VENTILATION SYSTEMS MODELLING AND DESIGN CHALLENGES

Potential of natural ventilation in shopping centres

Some Dutch Examples of Sustainable School Concepts Towards Plus Energy Schools

Empirical validation data sets for double skin facade models Larsen, Olena Kalyanova; Jensen, Rasmus Lund; Heiselberg, Per Kvols

Empirical validation data sets for double skin facade models Larsen, Olena Kalyanova; Jensen, Rasmus Lund; Heiselberg, Per Kvols

Double layer glass façade in the refurbishment and architectural renewal of existing buildings in Italy

Evaluation methods for indoor environmental quality assessment according to EN15251

TREES Training for Renovated Energy Efficient Social housing. Section 1 Techniques 1.2 Replacement of glazing

Building Technology Research in Architectural Practice: Lessons Learned from Implementations of Energy-Efficient Advanced Building Technologies

Summer season temperature control in Finnish apartment buildings

Assessing the energy performance of modern glass facade systems

Adding glazing as an energy saving renovation measure in cold climates

P2 GRADUATION PLAN: TU DELFT -BUILDING TECHNOLOGY. Design & Technology. Marten de Bruin. Façade Adaptive Heat Transfer by Changing Geometry

Chapter 7. Passive Solar Contents

Modelling Analysis of Thermal Performance of Internal Shading Devices for a Commercial Atrium Building in Tropical Climates

Literature Review Report in Double Skin Facades for Office Buildings. Harris Poirazis Harris Poirazis

Investigation of indoor climate in a naturally ventilated building

Design and retrofitting of a hybrid building in Athens

Comparative Study of Energy Consumption Optimization for. Different Orientations of School`s Buildings in Jordan

Thermal Comfort Measurements in a Hybrid Ventilated Office Room

Applications of ECOTECT and HEED in building energy analysis - Case study: A typical tube house in Hanoi

A Study on the Evaluation of Heating and Cooling Energy Efficiency in Residential Buildings for Climatic Zones of Turkey

Building performance analysis for double skin residential buildings ABSTRACT BACKGROUND. Porooshat Akhgari

Reducing energy demand in non-domestic buildings: integrating smart facades, ventilation, and surface heating and cooling

The Effects of Set-Points and Dead-Bands of the HVAC System on the Energy Consumption and Occupant Thermal Comfort

Cost-Benefit Analysis of Dwelling Retrofit Options

CONTROLITE. Intelligent Daylighting System FACADE SKYLIGHT

FEDERATION TOWER MOSCOW DIFFERENT ROOM CLIMATES UNDER ONE ROOF

In office buildings, often large windows have been. Total economy of windows and facades in low energy office buildings. Articles

STEADY STATE AND DYNAMIC THERMOPHYSICAL PARAMETERS OF TRANSPARENT BUILDING COMPONENTS

CASE STUDIES - CENTRE FOR SUSTAINABLE BUILDING (ZUB) KASSEL, GERMANY

Part 1 Review Questions on material covered in Midterms I & II

Observation of Liquid-filled Window without Presence of Liquid in Test Chamber

Young Cities Research Briefs 07 Architectural Energy Efficiency

CONTROLITE. Intelligent Daylighting System FACADE SKYLIGHT

New Generation Office Building

Q-Air unique selling propositions in detail

Parkview Green, Beijing Microclimatic envelope

Potential of Natural Ventilation in Shopping Centres Diederichsen, Alice; Friis, Kristina; Brohus, Henrik; Tranholm, Gitte T.

GLASS SELECTION GUIDE

Best Practice Guidelines for Double Skin Facades

HEADQUARTERS OF THE COMISIÓN NACIONAL DEL MERCADO DE VALORES. DOUBLE FAÇADE SIMULATION STUDY. Barcelona, Spain.

Low energy and level of requirements The example of flexibility in space planning

A STUDY OF WALL SURFACE TEMPERATURE VARIATIONS FOR HOUSING IN MODERATE CLIMATES

Ventilation of Dutch schools; an integral approach to improve design

CHAPTER 6 CONCLUSION

The Impact of VISIONWALL High Performance Windows on the Northern Telecom Building in Ottawa, Ontario

A Comparative Analysis On The Effect Of Double- Skin Façade Typologies On Overall Building Energy Consumption Performance In A Temperate Climate

THE USE OF SIMULATIONS TO SUPPORT THE RETROFITTING OF A DUTCH MONASTERY, LISTED AS A HISTORIC BUILDING AND BEING RE-USED AS AN OFFICE BUILDING

A COMPARISON OF MEASURED AND ESTIMATED ELECTRIC ENERGY USE AND THE IMPACT OF ASSUMED OCCUPANCY PATTERN

DYNAMIC FACADE. BUILDING ENERGY EFFICIENCY REHABILITATION.

Tage Møller Architect office building

DEVELOPMENT AND CONSTRUCTION OF BIOCLIMATIC DOUBLE SKIN ACTIVE FACADE FOR HOT AND HUMID CLIMATE OF UAE

Energy and indoor temperature consequences of adaptive thermal comfort standards

Responsive Building Elements Actual Development and Trends Within IEA

OPTIMIZATION OF WINDOW-WALL RATIO FOR DIFFERENT BUILDING TYPES

Review of DSF in Sweden

additional cooling energy consumption. Because the thermal resistance of windows has always been a weak point, even with vacuum glass or low-e glass,

Understanding thermal mass

Assessment of thermal comfort near a glazed exterior wall

Indoor environment for energy performance of buildings a new European draft standard

SOLAR PHOTOVOLTAIC ENERGY

HOW CURRENT TRENDS IN THE DESIGN OF FACADES INFLUENCE THE FUNCTIONAL QUALITY OF INTERIOR SPACES

Design of Sunshade Board with South External Window of Residential Building in Hangzhou Based on Software Simulation Analysis of Energy Saving

COMPUTATIONAL ASSESSMENT OF COOLING WITH LOW-TEMPERATURE HEATING SYSTEMS

THERMAL MASS CHAPTER 6. Understanding thermal mass. Seasonal effects of thermal mass

Performance of Glazing Materials for Atrium in Hot & Humid Climate

ARCH-MEDES (I) CONSULTANTS PVT. LTD. Green Park Delhi

Verified net Zero Energy Building with air source heat pumps for SME

Advanced Ventilation Technologies

What is Sustainable Design?

The case for research

presentation overview

CAMBRIDGE PUBLIC LIBRARY

Daylight has been a primary source of lighting in buildings. Daylighting improve indoor environmental quality and visual comfort. Moreover, it reduces

Building Concepts for a mid-century energy-neutral society

ARPAN JOHARI. Architect. 13/08/10 AW Design. Ahmedabad

How to Design Zero Emission Buildings

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress Heiselberg, Per Kvols. Publication date: 2016

Parametric Louver Design System Based On Direct Solar Radiation Control Performance

Development of Concepts for a Zero-Fossil-Energy Greenhouse

EE2E045 A Calculation Method on the Energy Demand of Urban Districts

Air distribution and temperature control in classrooms

BRF Kredit headquarters

Analysis of a plus-energy house for improved building and HVAC system design

Evaluation of natural ventilation systems in a landscaped office.

447 - Thermal Performance of Residential Buildings in Lisbon with Large Glazing Areas

Extended pilot study of an energy efficient glazed office building during pre-design and design. Åke Blomsterberg (WSP och LTH)

Introduction to basics of energy efficient building design

DEVELOPMENT OF A GUIDELINE FOR SELECTING A SIMULATION TOOL FOR AIRLOW PREDICTION. E. Djunaedy, J.L.M. Hensen, M.G.L.C. Loomans

Implementing the amended Energy Performance of Buildings Directive: Opening up the potential of windows

Martin Ratcliffe Visiting Research Fellow, Centre for Energy Studies at LSBU Head of Roger Preston Environmental

Transcription:

OVERALL PERFORMANCE OF VENTILATED DOUBLE FAÇADES COMPARED TO A STATE OF THE ART SINGLE SKIN FAÇADE J.H.A. Verdonschot, G. Boxem, and W. Zeiler, Technical University of Eindhoven, the Netherlands ABSTRACT The concept of a ventilated double façade is invented with the intention of improving the thermal qualities of a fully glazed façade. Over the years, the properties of the single glazed façade have improved. The aim of this study is to compare different ventilated double façades to a single skin façade and determine which façade has the best overall performance. To compare the façades, fifteen functional aspects on the areas of thermal and visual comfort, energetic and acoustical performance, ventilation and maintenance have been determined, next to eight realization aspects on the areas of costs, sustainability, flexibility and architecture. Measurements were performed on four existing façades for a period of one week in winter. Together with the gathering of information, this resulted in an evaluation of the total performance. In high-rise buildings, natural ventilation and shading devices in the cavity are the main advantages of the ventilated double façade. In low-rise buildings the performances can be equal, although the costs of the single skin façade rise quickly if a higher sound insulation is needed. It is therefore important to determine which performance has to be achieved in order to choose between a ventilated double façade and a single skin façade. KEYWORDS Performance Façade Comfort Winter Measurements INTRODUCTION I often say that when you can measure what you are speaking about, and express it in numbers, you know something about it; but when you can not express it in numbers, your knowledge is of a meager and unsatisfactory kind; it may be the beginning of knowledge, but you have scarcely, in your thoughts, advanced to the state of science, whatever the matter may be. William Thomson, Lord Kelvin (1824-1907) Modern facades often combine a wide diversity in functions. These functions have to be performed under strongly dynamic outdoor conditions and indoor demand. Thermal and visual comfort is determined by the presence of occupants, their location in the building, their activities and personal preferences. Ventilated double façades open up new possibilities for principal and architects seeking creative innovative design that is intelligently adapted to environmental conditions. Preservation of energy resources, occupant comfort and environmental impact limitation are the key issues of modern and sustainable architecture. A major portion of primary energy consumption, about 40 %, is used to create thermal comfort in buildings by heating, cooling, ventilating and lighting. The façade, in combination with the HVAC installation, is responsible for most of the energy used. In modern high performance office buildings, active and interactive façade technology is often used. Though these modern façade concepts should be an improvement, up to now efficiency is under discussion. Some disadvantages of the ventilated double façade are: - expensive - user unfriendly Corresponding Author: E-mail address: W.zeiler@bwk.tue.nl

- much unusable space - increased cleaning costs - high cavity temperatures In favour of the ventilated double façade are: - reliable, weather independent solar control - low g-values - low U-values - improved sound insulation - weather independent, natural ventilation - building height independent, natural ventilation Reduction in energy consumption and capacity of the HVAC system is one of the main arguments supporting the application of ventilated double façades (Saelens 2002, Saelens et al. 2003). But with the current state of the art single skin façades the arguments in favour of ventilated double façades are becoming less convincing. The main objective of this research (Verdonschot 2006) is to compare the overall performance of different ventilated double façades to the overall performance of a state of the art single skin façade. The overall performance of a façade is determined on the areas of thermal and visual comfort, energetic and acoustical performance, ventilation, maintenance, costs, sustainability, flexibility and architecture FAÇADES Ventilated double façades have many characteristics and therefore have to be categorized on several aspects. The classification that is used in this research is described in Loncour et al. 2004 and is based on three different aspects: - type of ventilation - partitioning of the façade - mode of ventilation in the cavity The two main catogeries of facades are: Single skin façade The ventilated double façades above are compared to the state of the art single skin façade of the 'Effenaar' in Eindhoven. The special double glazing of this façade has a very low U-value and ZTAvalue and is applied without the use of supporting heating units near the façade and a shading device. Ventilated double façades The façades that are subject of this research can be classified according to these three aspects (table 1). The ventilated double façade of the Kennedy Business Centre in Eindhoven is naturally ventilated, partitioned by storey and the mode of ventilation in the cavity is called an outdoor air curtain. This means that outdoor air enters the cavity and also leaves the cavity to return outside. The ventilated double façade of the ABT-office in Velp is mechanically ventilated, it is a climate window and the mode of ventilation is called a reversed air exhaust, which means that indoor air is directed through the cavity to outside. The ventilated double façade of the 'Bouwhuis' in Zoetermeer is a multi-storey type and has a hybrid ventilation system. In the summer the mode of ventilation is defined as an outdoor air curtain (natural ventilation) and in the winter the mode of ventilation is called an air supply (mechanical ventilation). In the air supply mode, outdoor air enters the cavity and is then led into the building.

Table 1: Overview ventilated double façades Building Kennedy Business Centre ABT-office Bouwhuis Partitioning Ventilated double façade partitioned by storey (corridor type) Ventilated double window Ventilated double façade multi-storey type Type of ventilation natural mechanical Summer: natural Winter: mechanical Mode of ventilation Summer Winter METHOD Since the comparison of the four façades takes place on many different fields, an evaluation method that is often used to make such a comparison is chosen: the evaluation method of Kesselring (van den Kroonenberg and Siers 1998) Decision support methods are intended to help designers in making decisions. As people are limited in their capacity to process information, evaluation should be conducted in terms of each criterion separately. Subsequently, the values determined have to be aggregated into a score for the overall value of each alternative. Kesselring developed a visualization technique, with which different variants can be compared with each other. Within the Kesselring method, the criteria for the requirements are separated into a category for realization and a category for functionality. By doing this the strong point can be seen in the so called S-(Stärke) diagram. To visualize the scores the criteria of the program of requirements are separated in groups with relating requirements. The first group of criteria has to do with the functionality of the design and the other group of criteria with the realization, see figure 1.

Functioning Realisation Total; Figure 1: Separation into Functional and Realization aspects Each group of criteria is evaluated and supplementary to the total score of each group of criteria. These criteria are derived from the program of requirements, the design brief. The total score of the functional and realization criteria is expressed as a percentage of the maximum score to gain. In the diagram the percentage of the criteria for functionality is set out on the y- axis and the percentage of the criteria for realization on the x-axis (figure 2). The best variants lie near the diagonal and have high scores. It is wise to set values to limit the selection area. A practical suggestion is to divide the area in two with a minimum border set by the x- and y-value of 40 and by (x+y)-value of 55% (figure 2). The Kesselring method makes singularities visible, whereas that in the normal choice tables and bar diagrams only could be retrieved with much effort. In the Kesselring diagram it is easy to see if the improvements must take place in the functionality or on the realization side. Total; 100 % S-diagramm solutions Functional aspects 40% limit 0 % Realization aspects 100 % Figure 2: S-diagram of Kesselring showing the evaluated functional and realization aspect of the 4 design proposals of the legenda. A total of 23 evaluation criteria, fifteen functional aspects with respect to the operational period and eight aspects with respect to the realization period, are determined. A number of these criteria resulted in measurements that are performed in four office buildings in Netherlands, each with its own characteristics. The other criteria are evaluated based on information by the building owners and users.

Measurements The measurements are performed in the month February and March of 2006. The results of these measurements are used to calculate the U-value, g-value, daylight factor, temperature gradient, radiation asymmetry and draught. The measurement set-up at the four different facades is basically the same. The surface temperatures of both sides of both panes are measured in one line and not too close to the window frame. The heat fluxes are measured in the same line as the surface temperatures. The air temperatures in the cavity are measured at three heights, as low as possible, as high as possible and in the middle. The pyranometer, cup anemometer, lux meter and air temperature and relative humidity sensor to measure the outside conditions are placed on appropriate positions on the roof. The air temperatures inside are measured at 0.5 m from the façade at a height of 0.10, 0.50, 1.10 and 1.75 m and in the middle of the room. The mean radiant temperature and relative humidity are also measured in the middle of the room. The air velocities are measured on the same positions as the air temperatures inside. The horizontal radiation asymmetry is measured at 0.5 m from the façade at a height of about 1.3 m and the vertical radiation asymmetry is measured at the same distance from the façade at a height of about 1.0 m. The solar radiation inside is measured vertically at a minimum distance of the façade. RESULTS AND DISCUSSION Measurement results With the results of the measurements described in the previous section, the following values are calculated: the U-value, the solar factor, the daylight factor, the temperature gradient, the horizontal radiation asymmetry, the occurrence of draught and the sound insulation. Table 2 shows these values for all four façades. Table 2: Measurement results Effenaar Kennedy BC ABT-office Bouwhuis U-value [W/m 2 K] 1.1-1.2 0.9-1.1 1.1-1.2 0.4-1.0 Solar factor [-] 0.1 0.2 0.4 0.2 Daylight factor [-] 7-8 8-10 5-9 6-9 Temperature gradient [ºC/m] 0-1 0-2 0-2 0-1 Horizontal radiation asymmetry [ºC] 1-2 0-1 0-1 0-1 Draught [-] minimal minimal none none Sound insulation [db(a)] 29 36 32 40 Performance assessment According to the measurement results described above and the information that is gathered about the façades, the buildings are given scores on all 23 aspects. These results are plotted in the Kesselring diagram in figure 3. The diagram shows that the façade of the Kennedy Business Centre has the highest and well balanced performance of the four researched façades. The Bouwhuis has a similar score with respect to the functional aspects, but a much lower score with respect to the realization. Opposite to that, the Effenaar has a much lower score than the Kennedy Business Centre with respect to the functional aspects, but only a little lower with respect to the realization. The ABT-office has the lowest score with respect to the realization and a similar score as the Effenaar with respect to the functional aspects.

Kesselring diagram Functional aspects [%] 100 90 80 70 60 50 40 30 20 10 0 0 10 20 30 40 50 60 70 80 90 100 Realization [%] Effenaar Kennedy BC ABT office Bouw huis Figure 3: Kesselring diagram of the four façades Discussion The objective of this study is to compare different types of ventilated double façades to a state of the art single skin façade in order to evaluate the application of a certain type of ventilated double façade. The total performance of each façade is a result of the performance of each of its characteristics. Since only one façade of each type is researched, it is difficult to determine the advantages and disadvantages of a façade type. The results of this research should be joined with other studies of ventilated double façades to be able to draw conclusions about the application of a certain façade type. In order to draw a more general conclusion from the results of this research, certain characteristics of the researched façades that are not inherent to the façade type, are changed to improve the overall performance of the façade type. Another aspect that should be included in further research, is the performance of the façade in the summer. Several evaluation criteria, like for example the solar factor will have different values in summer, caused by the use of a shading device in the cavity. The change of these values over the seasons should be taken into account, since this can be one of the advantages of an active façade. The evaluation model that is used in this research is useful to determine which façade has the most advantages for a certain location and certain demands with respect to the performance. In the design process, the choice between a ventilated double façade and a single skin façade is often mainly based on the investment costs. If this is the case the evaluation model is not effective due to the fact that the costs are just a very small part of the evaluation. High rises in the investment cost only result in a small decrease of the overall performance. CONCLUSIONS A first result of this study is the comparison of the three existing ventilated double façades to a single skin façade. The façade of the Kennedy Business Centre and the Bouwhuis have a better performance than the Effenaar, according to the evaluation model. The overall performance of the façade of the ABT-office is not better than that of the Effenaar. A more general conclusion with respect to the façade type can be drawn from the evaluation of the improved façades. The overall performance of the single skin façade (based on the Effenaar ) in case of low-rise buildings, the ventilated double façade, corridor type (based on the Kennedy Business Centre) and the ventilated double façade, multi-storey type (based on the Bouwhuis ) are close

together. Leading to the conclusion that a single skin façade can reach the same performances as a ventilated double façade. However, the high sound insulation and low U-value and solar factor of the single glazing cause a high rise in costs for the façade, which could mean that the advantage of the low cost for a single skin façade is no longer present. Together with the fact that the application of an outside shading device and operable windows is only possible in low-rise buildings, the advantages of the single skin façade decrease. In high-rise buildings, ventilated double façades have the advantage of the possibility to apply natural ventilation through operable windows. And also to apply a shading device in the cavity, which can be almost as effective as an outdoor shading device if the device is placed near the outside glass layer. In short, the possibility to apply natural ventilation and a shading device in the cavity in high-rise buildings are the main advantages of the ventilated double façade over the single skin façade. In lowrise buildings the performance of a ventilated double façade can also be achieved with a single skin façade. It is therefore very important to determine which performance has to be achieved in order to choose between a ventilated double façade and a single skin façade. Recommendations The measurements that are performed in this study only address the performances of the façades in the winter period. The measurements should be repeated in the summer to obtain an overall picture of the performances. Especially the solar factor can have a different performance in winter than in summer, which on its turn influences other criteria and thus all the more the total performance. This difference is caused by the shading device that is used in the summer. The Effenaar does not have a shading device, thus the solar factor that is measured should be the same as in the winter. The other façades all have a shading device in the cavity, which contributes to a lower solar factor. Therefore the measurements of the solar factors have to be repeated in summer when a low solar factor is desirable. In addition, a higher solar factor in winter and lower in summer could be an advantage of the ventilated double façade compared to a single façade with a constant solar factor. In order to determine well-founded advantages and disadvantages of a certain façade type, it is recommended to include several façades of the same type in the evaluation model and perform measurements on these façades with the same classification. This way, the fortuitous advantages of a façade that, on its own, represents a façade type, are taken into account. Furthermore, a more in-depth investigation of the cost aspects of the façade and their dependence on the different criteria is recommended. ACKNOWLEDGEMENT Thanks goes to Nelissen consultants in the persons of Elphi Nelissen and Pieter van der Palen for their support during the project and thanks to PIT for their financial support. REFERENCES 1. D. Saelens (2002) "Energy performance assessment of single storey multiple-skin facades" Proefschrift Katholieke Universiteit Leuven, Faculteit Toegepaste Wetenschappen, ISBN 90-5682-370-1. 2. D. Saelens et al. (2003) "Energy Performance Assessment of Multiple Skin Facades" International Journal of HVAC&R Research, vol.9, nr.2, 167-186. 3. J.H.A. Verdonschot (2006) "Performance of ventilated double facades compared to a single skin facade" MSc-thesis, Technische Universiteit Eindhoven. 4. X. Loncour et al. (2004) "Ventilated double façades Classification & illustration of façade concepts" Report of the second biennale of the Ventilated double Façade project, BBRI, Brussels. 5. H.H. van den Kroonenberg and F.J. Siers (1998) "Methodisch ontwerpen" Educatieve Partners Nederland BV, Houten, Netherlands (Dutch).