Technical Bulletin #27 Wiring for Architectural Applications

Similar documents
SPECIFICATION FOR THHN/THWN-2/THW/THWN/TW ARROW ROUTE, FONTANA CA

WHAT MAKES ENCORE S XHHW-2 UNIQUE? Our SuperSlick Elite technology may be installed without additonal lubricant

PV Solar Wiring Solutions

America s Wire Company

ELECTRICAL SOLUTIONS

MUSCO ENGINEERING ASSOCIATES Consulting Engineers

CATALOG. WIRE and CABLE. borderstates.com

ABOUT US. 830 South West Street / Sikeston, MO / F: alanwire.com

BLAZE BASICS 100 LED Tape Light 24V. 18/ft Color Temperature. 2700K, 3000K, 5000K CRI 90+ Dimmable

ANNEX B: APPLICATION INFORMATION FOR AMPACITY CALCULATION ITEMS B (B)(1) THROUGH B (B)(7)

Inspection Guide for PV Systems in One- and Two- Family Dwellings (For Rooftop Photovoltaic Systems meeting the Standard Plan)

Cables ELE E L CT E C R T R IC I C A A L L

SECTION INSULATED WIRE AND CABLE

TECHNICAL DATA. A REFERENCE FOR The Electrical Power Industry. www. ElectricalPartManuals. com ANDERSON POWER SYSTEMS, INC.

BASIC CONCEPTS IN ELECTRICAL DESIGN. Prepared by Engr. John Paul Timola

Highly flexible control cable with PVC core insulation and PVC sheath - certified for North America

Nominal Core OD Materials. Conductor (stranding) Diameter Nom. DCR

Building Wire CARRYING YOUR ELECTRICITY

Una e mpre sa Vi akab l e GLOSSARY.

DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7

3M Round, Jacketed, Flat Cable.050" 28 AWG Stranded, Mass-Term, PVC/PVC 3759 Series

Purchase Now ANSI/ICEA S STANDARD FOR 600 VOLT SINGLE LAYER THERMOSET INSULATED UTILITY UNDERGROUND DISTRIBUTION CABLES

NEC Ampacity Data Table (B)(2)(b) Ambient Temperature Correction Factors Based on 40 C (104 F)

SECTION A. ASTM B3 - Standard Specification for Soft or Annealed Copper Wire; 2013.

PRODUCT SELECTION LOCATOR

S966SP Cover 1G Gfci/Deco Wet Loc Vert Metal Gy. Material, Color, and Finish Color Gray 0 ELECTROSTATICALLY PAINTED BAKED POWDER COATED

3M Ground Plane Cable.050" 28 AWG Stranded, One Drain, PVC 3476 Series

ELECTRICAL DEFINITIONS

SECTION WIRE AND CABLE Raceways and Conduit Motor Power and Control Wiring.

Conductor Shield A combination of semi-conducting tape and extruded thermosetting semi-conducting material meeting UL 1309, IEEE 1580 and UL1072.

(Condensed from National Electric Code)

WIRING METHODS CHAPTER 38

WIRE AND CABLE Raceways and Conduit Motor Power and Control Wiring.

3M Round, Shielded/Jacketed, Flat Cable.050" 28 AWG Stranded, Mass Terminatable, PVC/PVC 3659 Series

AGENDA. NEC Code-Making Panel 6. Report on Comment Meeting. December 6 December 8, Redondo Beach, CA

An Urgent Bulletin from CSA International

SERVICES CHAPTER 35. wire. For all other installations, the rating of the ungrounded conductors shall be not less than 60 amperes.

OVERHEAD SERVICES - RESIDENTIAL & GENERAL SERVICE. See Chapter 3, Section 3.01 for more information about point of entrance (POE).

TEMPORARY METER POLE INSTALLATION

Highly flexible, screened control cable with PVC insulation and PVC inner and outer sheath - certified

Electrical Conductors Line

SOUTH CAROLINA ELECTRIC COOPERATIVES' PRIMARY UNDERGROUND POWER CABLE SPECIFICATION

ELECTRICAL SAFETY Information Bulletin

ELECTRICAL CODE TRADE REFERENCE

Highly flexible, screened control cable with PVC insulation and PVC inner and outer sheath - certified

SECTION ELECTRICAL CABLE. 1. Trench excavation, backfill, and compaction; Section

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (24 Volt AC/DC or Less)

NORTHEASTERN REMC ELECTRIC STANDARDS MANUAL


IEEE 1580 Type P MOR Polyrad XT-125 Multi Conductor

3M Pleated Foil Shielded Cable.025" 30 AWG Solid, TPE Primary, PVC Jacket, Low Skew Series

ELECTRICAL BULLETIN

1. The plan needs to show compliance with the 2013 CEC, 2013 CBC and 2013 CRC. [ CBC] RESPONSE:

ORDINANCE NO NOW, THEREFORE, BE IT ENACTED BY THE CITY COUNCIL OF THE CITY OF FAIRBANKS, ALASKA, as follows:

3M Heavy Wall Heat Shrink Tubing ITCSN

DIVISION 26 ELECTRICAL Electrical Power Conductors and Cables

POWER AND LIGHTING DISTRIBUTION

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 7/14/10 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

Standard of Practice - Campus Electrical Distribution System

DON T JUST PULL PULL AHEAD OF THE COMPETITION

CONSISTENCY MEETING DEPARTMENTAL GOALS: % 1 DAY TURN AROUND % CONTRACTOR PASS RATE QUALITY INSPECTIONS! EXCELLENT CUSTOMER SERVICE!

Section ARMORED MEDIUM VOLTAGE CABLES SHIELDED 3 CONDUCTOR POWER CABLE - INTERLOCKED ARMOR

SECTION WIRE, CABLE AND BUSWAYS. A. This section specifies providing wire, cable and busways.

JAMES MONROE. WIRE & CABLE CORPORATION ETT Traveling Cable Hoistway Cable Compensating Cable Stationary Communications Cable ELEVATOR CABLES

POWER AND LIGHTING DISTRIBUTION

SECTION GROUNDING AND BONDING

E101 ELEC. SPEC. Scale NONE

POWER AND LIGHTING DISTRIBUTION Reserved

3M Round, Shielded/Jacketed, Disc. Wire Cable 26 AWG Solid, Twisted Pair, PVC/PVC 3560 Series

2008 NEC Guide Lines for Home Owner Doing Electrical Work on their Property

Detailed Specifications & Technical Data

Evaluation of Aluminum Cable Presentation for IEEE OCS September 14, 2011 Breck Booker, Southwire

SSL Series 1.2 IP X8 waterproof solution. Product Data Sheet. REV. 0, 2014 August

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update.

Residential Rooftop PV

VITALink 2-Hour Fire Resistive Circuit Integrity Cable with Hose Stream

DON T JUST PULL PULL AHEAD OF THE COMPETITION

UNIFIED FACILITIES GUIDE SPECIFICATIONS

NEC 2014 Code Changes

Wyoming Division IAEI Annual Meeting/Seminar 2003 Code Panel Questions Answers in BOLD, using 2002 NEC

SERVICE ENTRANCES. OPPD S Electrical Service Designer (ESD) shall designate the Point Of Entrance.

FOR ALL STAKEHOLDERS TO HAVE A SUCCESSFUL PROJECT

WESTERN CONNECTICUT STATE UNIVERSITY ELECTRICAL SAFETY PROCEDURE S-109

Installation of CSST Gas Piping Systems

Flexible Conduit Systems

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF CABLE

SECTION GROUNDING AND BONDING

Bulletin Grounding and bonding of solar photovoltaic systems Rules , , , and

DOWNTOWN UNDERGROUND NETWORK SECONDARY SERVICES GUIDELINES

Temporary Wiring Practices And Guidelines For NECA. National Electrical Contractors Association Omaha, Nebraska

1. Section COVER PAGE: remove and replace with new Cover Page, Attached.

Caledonian Cables Ltd

DIVISION 16. Electrical Specifications

MESH FLOOR HEATING SYSTEMS INSTALLATION INSTRUCTIONS

SPORTSBEAMS 1500 LED USER MANUAL SPORTSBEAMS LIGHTING, INC. v.1.0

Table of Contents. Sunslates6 TM Installation Manual. Aesthetic Green Power, Inc. Page 1 of 15 REV /25/13

MREC March, 2005 Powering the Dairy Industry

WESTERN UNDERGROUND COMMITTEE GUIDE 2.14 (2.14/01/0990)

Transcription:

400, du Parc, Saint-Eustache, Québec Canada, J7R 0A1 Tel: +1.450.491.5671 +1.800.665.1166 Fax: +1.450.491.3788 www.heicolighting.com Technical Bulletin #27 Wiring for Architectural Applications WIRE SIZE AND GAUGE AWG stranded and tinned wire is recommended. 16 and 18 AWG can also be used in some circumstances. Refer to technical bulletin #7 for more details. Verify maximum outside wire diameter allowable for Virgolite modules as per figure 1. Virgo TM XS maximum outside diameter wire size is 0.120 (3.05mm) Virgo TM S M - X (long and short), Virgo+ TM LS1 and Virgo+ TM LS2 - LS3 - LS4 - LS6 maximum outside diameter wire size is 0.150 (3.94mm) Any insulation color can be used when it is clear that it leads to a dedicated LED circuit. Due to the high frequency nature of the output power of the LMPS power supplies; increasing wire size will not permit a longer run. Figure 1: Accepted diameter sizes of single stranded wire Due to the variety of installation types and environments it is the responsibility of the installer or end-user to select the proper wire type for the application. 1/8

GENERAL CONSIDERATIONS DRY LOCATIONS Consult the relevant sections of chapter 3 and section 725 of the National Electrical Code (NEC) or section 16 and table 19 of the Canadian Electrical Code (CEC) and applicable standards. Conductors exposed to direct sunlight shall bear the mark SUN RESISTANT, SR, or similar or be listed as being sun resistant if they don t bear such marking. Wiring connections or splices shall only be executed with listed connectors rated for a minimum of two (2) AWG wires. Waterproof connectors need to be used for connections made in wet locations. Dry locations are defined as a location not normally subject to dampness, but may include a location subject to temporary dampness as in the case of a building under construction, provided that ventilation is adequate to prevent the accumulation of moisture. Cove lighting Under cabinet lighting Decorative lighting Interior architectural lighting Display cases According to National Electrical Code (NEC) table 310.104 cable types suitable for dry locations are: RHH, RHW, RHW-2, THHN, THHW, THW, THW-2, THWN, THWN-2, TW, USE, USE-2, XHH, XHHW, XHHW-2, Z, ZW. According to the Canadian Electrical Code (CEC) table 19 cable types suitable for dry locations are: R90, RW90, RW75, TW, T90 NYLON, RPV90. Suggested manufacturers: Type XLPE Building wire RW90 PVC Low Voltage Building wire T90/TWN75 Building wire THHN / THWN / TWN75 / T90 Simpull T90 Nylon / TWN75 AWG Outside diameter 0.130" 3.302mm 0.112" 2.845mm Virgo S - M X Virgo+ LS1 Virgo+ LS2 - LS3 - LS4 - LS6 Virgo XS Manufacturer HEICO lighting part number Yes No General Cable - Yes Yes General Cable - Yes Yes Southwire C8750022 Yes Yes Southwire - Example: An interior cove lighting application is considered as exposed wiring in dry or damp locations, suitable wire types would be: R90 TW T90 NYLON Specifications are subject to change without notice (Technical bulletin #27) 2/8

DAMP LOCATIONS Damp locations are defined as an interior or exterior location that is normally or periodically subject to condensation or moisture in, on or adjacent to electrical equipment and includes partially protected locations under canopies, marquees, roofed open porches and similar locations. This also includes interior locations subject to moderate degrees of moisture, such as some basements, some barns and some cold-storage warehouses. Locations sheltered from the weather are considered damp locations. Covered terrace lighting Covered outdoor alley Refrigerators Metal light boxes According to National Electrical Code (NEC) table 310.104 cable types suitable for damp locations are: RHH, RHW, RHW-2, THHN, THHW, THW, THW-2, THWN, THWN-2, TW, USE, USE-2, XHH, XHHW, XHHW-2, Z, ZW. According to the Canadian Electrical Code (CEC) table 19 cable types suitable for damp locations are: R90, TW, T90 NYLON, RPV. Suggested manufacturers: Type XLPE Building wire RW90 PVC Low Voltage Building wire T90/TWN75 Building wire THHN / THWN / TWN75 / T90 Simpull T90 Nylon / TWN75 AWG Outside diameter 0.130" 3.302mm 0.112" 2.845mm Virgo S - M X Virgo+ LS1 Virgo+ LS2 - LS3 - LS4 - LS6 Virgo XS Manufacturer HEICO lighting part number Yes No General Cable - Yes Yes General Cable - Yes Yes Southwire C8750022 Yes Yes Southwire - Example: A covered terrace lighting application is considered as exposed wiring in dry or damp locations, suitable wire types would be: R90 TW T90 NYLON Specifications are subject to change without notice (Technical bulletin #27) 3/8

WET LOCATIONS Wet locations are defined as a location in which liquids may drip, splash, or flow on or against electrical equipment. This also includes outdoor locations, which are any location exposed to the weather. Locations that are sheltered from the weather are not considered outdoor locations. Conductors exposed to direct sunlight shall bear the mark SUN RESISTANT, SR, or similar or be listed as being sun resistant if they don t bear such marking. Deck lighting Eaves lighting Exterior architectural lighting (doesn t include direct burial applications) According to National Electrical Code (NEC) table 310.104 cable types suitable for wet locations are: RHW, RHW-2, THHW, THW, THW-2, THWN, THWN-2, TW, XHHW, XHHW-2, ZW. According to the Canadian Electrical Code (CEC) table 19 cable types suitable for wet locations are: RW75, RWU75, RL90, R90, RW90, RWU90, TW, TWU, TWU75, TW75, TWN75, RPV90, RPVU90. Suggested manufacturers: Type XLPE Building wire RW90 (solid) XLPE Building wire RW90 (stranded) PVC Low Voltage Building wire T90/TWN75 Building wire THHN / THWN / TWN75 / T90 Simpull T90 Nylon / TWN75 AWG RPV90 Outside diameter 0.120" 3.05mm 0.130" 3.302mm 0.112" 2.845mm 0.130 3.302mm Virgo S - M X Virgo+ LS1 Virgo+ LS2 - LS3 - LS4 - LS6 Yes Yes Suitable for : Virgo XS Yes Sun resistant Manufacturer HEICO lighting part number * see note Yes General Cable A8750020 No * see note Yes General Cable A8750021 Yes Yes No General Cable - Yes Yes No Southwire C8750022 Yes Yes No Southwire - Yes Yes No Nexans - * Note: Wiring connections or splices shall only be executed with listed connectors rated for a minimum of two (2) AWG wires. A proper wire splice method with waterproof connectors shall be used for connections made in wet locations. Examples: A deck lighting application is considered as exposed wiring in wet locations, when not exposed to sunlight, suitable wire types would be: RW90 TW TWN75 A deck lighting application is considered as exposed wiring in wet locations, when exposed to sunlight, suitable wire types would be: RW90 (needs to be sun-resistant) Specifications are subject to change without notice (Technical bulletin #27) 4/8

CONDUCTORS IN AN ELECTRICAL ENCLOSURE An electrical enclosure is a cabinet, panel board or any certified enclosure that prevents the wires and therefore the modules from being directly accessible. The AWM, MTW and TEW conductor types, usually used in this type of installation, are recognized components for use in an overall listed product and are not intended for installation in buildings or structures. Electric sign Stand alone luminaire According to National Electrical Code (NEC) table 310.104 cable types suitable for use within an electrical enclosure are: AWM and MTW. According to the Canadian Electrical Code (CEC) table 19 cable types suitable for use within an electrical enclosure are: TEW. Other conductor types (like armored cable) can be used when the electrical code permits it. Specifications are subject to change without notice (Technical bulletin #27) 5/8

TRANSPORT CONDUCTOR The transport conductor goes from the power supply to the LED loop. The transport conductor needs to be compliant for use with Class 2 power sources. A typical wire type is either CL3P or CL2P because of their ease of installation in many environments such as plenums. Power supplies in an electrical room away from the modules Long distance in between modules or groups of modules According to National Electrical Code (NEC) table 310.104 cable types suitable for use in Class 2 circuits are : CMP, CL3P, CL2P, CMR, CL3R, CL2R, PLTC, CMG, CM, CL3, CL2, CMX, CL3X, CL2X. According to the Canadian Electrical Code (CEC) table 19 cable types suitable for use in Class 2 circuits are: FCC, CMP, CMR, CMG, CM, CMX, CMH, CMUC. Other conductor types (like armored cable) can be used when the electrical code permits it. Suggested manufacturers: Type AWG HEICO lighting part Part number Manufacturer (2 conductors) number CL3P 454696ABK Paige A8750012 CL3P 3052S General Cable - Note : The CL3P Paige cable sold by Heico lighting TM has 2 yellow conductors instead of the black and white specified on the Paige product sheet. Only the colors are different, the ratings and certifications remain the same. This cable is only available through Heico lighting TM. Specifications are subject to change without notice (Technical bulletin #27) 6/8

CONDUCTOR MARKINGS The listing and/or marking shall be used to ensure suitability for the use and location. The listing and/or marking shall be used by the inspection authories to approve the installation. Wires exposed to direct sunlight shall bear the mark SUN RESISTANT, SR, or similar or be listed as being sun resistant if they don t bear such marking. Marking for suggested cables Type Manufacturer Marking XLPE Building wire RW90 (solid) XLPE Building wire RW90 (stranded) PVC Low Voltage Building wire T90/TWN75 Building wire THHN / THWN / TWN75 / T90 Simpull T90 Nylon RPV90 CL3P CL3P (HEICO lighting TM version) CL3P General Cable General Cable General Cable Southwire Southwire Nexans Paige Paige General Cable GENERAL CABLE (PLANT OF MFG) CSA RW90 XLPE SIZE (AWG OR KCMIL) CU 600V (-40 C) YEAR OF MFG SEQUENTIAL METER MARKING NOTE: for black insulation add SR GENERAL CABLE (PLANT OF MFG) CSA RW90 XLPE SIZE (AWG OR KCMIL) CU 600V (-40 C) YEAR OF MFG SEQUENTIAL METER MARKING NOTE: for black insulation add SR GENERAL CABLE (PLANT OF MFG) (YEAR OF MFG) THHN/THWN SIZE (AWG OR KCMIL) (MM2) CU GAS AND OIL RES II, 600 VOLTS, VW-1 OR AWM (UL) E-103886 C(UL) T90 NYLON/TWN75 FT1 (-25 C) AWG 2.08MM2 LL49446 T90 NYLON TWN75 THHN THWN CSA C-US FT1 600V SOUTHWIRE #EEEE# #P# (UL) (AWG ) 2,082 mm2 CU TYPE MTW OR THWN OF THHN OR GASOLINE AND OIL RESISTANT II OR AWM 600 VOL TS VW-1 --- CSA T90 NYLON OR TWN75 600 VOLTS FT1 NON-ANCE 90 (D)C --- RoHS (MONTH/YEAR) NEXANS EXELENE AWG (2.081mm2) CSA LL23462 F RPV90 XLPE 40C 90C 600V SR PAIGE LoVo 454696AWH E191597 ++ (05-49399) CL3P/FPLP (UL) 2/C AWG RoHS COMPLIANT PAIGE ELECTRIC LED POWER SUPPLY CORD 454696AWHY-MOD E191597 ++ (01-51709) CL3P/FPLP (UL) 2/C AWG RoHS COMPLIANT CAROL A (R) AWG--E3052S--75C E60233-8 (UL) CL3P --- MADE IN USA (DATE CODE) (TRUMARK SEQUENTIAL FOOTAGE) The aforementioned markings are only given as indicative information. The specification sheet of the manufacturer and listing shall be consulted to get all the required information to ensure approval of the installation by the inspection authorities. Specifications are subject to change without notice (Technical bulletin #27) 7/8

Always refer to the appropriate electrical code for wire selection, installation and suitability of use. Suggested wires have been tested for outside diameter by HEICO TM lighting. Other similar wires from other manufacturers can also be used. The suggested wires and manufacturers are guidelines only and not a warranty of compliance for a particular application or environment. It is the responsibility of the installer to verify wire suitability for the application and environment. For other applications contact HEICO lighting TM All technical data in this technical bulletin is based on test results and is believed to be correct. However since the end use of HEICO lighting TM products, usage application and installation, is beyond our control, HEICO lighting TM makes no warranty expressed or implied as to the fitness of use. Their use shall be solely by the judgment and at the risk of the user notwithstanding any statement in this technical bulletin. The installer is responsible to select the compliant wire insulation in accordance with the National Electrical Code (NEC) in the United States or the Canadian Electrical code (CEC) (CSA22.1) in Canada. Also follow local electrical code ordinances when applicable. Class 2 circuits shall NOT be mixed with Class 1 circuits and shall not be connected to ground. Due to the variety of installation type and environments it is the responsibility of the installer or end user to select the proper wire type for the application. The location definitions are taken from the American Electrical Code (NEC) article 100 and from the Canadian electrical code (NEC) section 0 and appendix B. Refer to the product sheet for more information about the LMPS-350, LMPS DC-350, LMPS-750 power supplies and the Virgolite TM modules. HEICO lighting, 2012 All rights reserved. Made in Canada. For customer service, call 1.800.665.1166 Specifications are subject to change without notice (Technical bulletin #27) 8/8