testo 616 Appareil de mesure de l'humidité

Similar documents
testo Bedienungsanleitung Instruction manual Mode d emploi Manual de instrucciones Manuale di istruzioni Manual de instruções

Visit us at

Visit us at

Short manual testo

MATERIAL MOISTURE METER

testo 327 Flue gas analyzer, country-specific version D Instruction manual

Industrial flue gas probes. Instruction manual

Instruction Manual Pocket scale

Operation Manual. Professional Weighing Equipment. MRB Series Mid Resolution Balances. MRB 500g MRB 1200g MRB 2500g MRB 6000g MRB 10000g

testo 310 Flue gas analyzer Instruction manual

Gelovit 200 en English

KERN EMS Version /2012 GB

PINLESS LCD MOISTURE METER WITH TRICOLOR BAR GRAPH USER S MANUAL

Professional Weighing Equipment. K-Series Scales. Operation Manual KHR 6000 KHR 123 KHR 502 KHR 3001

MEDIZINTECHNIK FÜR TIERÄRZTE

Operating Manual. Professional Weighing Equipment. TB Series intelligent weighing machine. Touch Color Screen HIGH RESOLUTION BALANCE

Manual Material Thickness Meter PCE-TG1XX

USER MANUAL EVO FC. wood & air humidity moisture meter. Excellent Business Conditions. Version 01/2016

Operating manual Pallet truck scale

VI-D4. Concrete Moisture Meter

PINLESS LCD MOISTURE METER WITH TRICOLOR BAR GRAPH USER S MANUAL

Operating Instructions Hanging Balance

Installation on underfloor heating

testo 310 Flue gas analyzer

LC-VS 60 Operation Manual

Operating Instructions. Electronics module. VEGAPULS series 60. Document ID: 36801

Environmental Equipment, Inc.

User manual AGRETO HFM II AGRETO electronics GmbH

Operating Manual. Professional Weighing Equipment SCT SERIES Small Counting Scales. SCT 600g SCT 1200g

GM610 GM620. Moisture Meter. User's Manual SET SET ENTER HOLD ENTER HOLD GM610. GM620 Moisture Meter. Moisture Meter. Version:GM610/GM620-EN-0

Installation instruction Maintenance Bypass option

Elcometer Concrete Moisture Meter

Instruction Manual HI Portable ph/ec/tds/ C Meters

Version 1.0 Hydromette H 35 1

CN Series P.N , Software rev. T 8, Revision A1- July 2014

Operating instructions Precision balances

Manual. AGRETO Hydraulic Scale AGRETO electronics GmbH

Operating manual Digital refractometer

Model M120 Mini Temperature/Humidity Meter

model QRI User manual

Instruction Manual ODY-1012

PE45 AMAZON MONKEY BARS OWNER'S MANUAL

BC Series Compact Counting Scale INSTRUCTION MANUAL

User Manual. Biomass moisture meter. humimeter BM1

user guide CME4 concrete encounter

Concrete Moisture Meter CM 1700

PMA 31-G. English. Printed: Doc-Nr: PUB / / 000 / 00

PRECAUTION. Thank you for purchasing our company Air Flow. This manual provides relative information on how to

RAUPEX SPEED SYSTEM Installation Guide

Flame Spread Performance of Wood Products Used for Interior Finish

Manual Rotary Heat Sealers. Type: F108TX. List of content : Introduction 2. General description 3. Application 4. Safety precautions 5

testo 206 ph / Temperature Measuring Instrument Bedienungsanleitung Instruction Manual Ðóêîâîäñòâî ïîëüçîâàòåëÿ

ZX70 & ZX80 SERIES PRECISION DECADE RESISTANCE BOX

KERN HDB-N Version /2016 GB

Operating Instructions. Supplementary electronics. For 4 20 ma/hart four-wire. Document ID: 42766

User Instructions for pin-less Ligno-Scanner S and Ligno-Scanner D

AXIS II RC DRONE WITH CAMERA

Dual Port isolated USB Charger

Operator Manual. OHAUS Aviator 7000

Contents. 1. About this edition of user instructions

Weighing Indicator YH-T3. User Manual

PE21 AMBER DOUBLE SWING OWNER S MANUAL

User Manual Agreto Heavy Duty Modules 5t/10t/15t

PE57 HOLT 2 DOUBLE SWING OWNER S MANUAL

INDEX Page SERVICE & GUARANTEE

PURE WATER METER Model : PWA-301

Owner s Manual & Safety Instructions

Instruction Manual ODY-1012

Operation Manual INCUBATOR2 Dual Dry Block Incubator

KANE510. Portable Oxygen Analyser. Stock No: April Kane International Ltd

User manual. AGRETO Soil Compaction Tester AGRETO electronics GmbH

Imperial Series. Model IMP-425/525/625/825/1000AP IMD-425/525/625/825/1000AP IMP-1025/1200/1500/2000AP IMD-1025/1200/1500/2000AP

j u n c k e r s i d e a l w i t h u n d e r f l o o r h e a t i n g

EL-USB-2-LCD Temperature, Humidity and Dew Point Data Logger with LCD Screen

USER S MANUAL release 1.0

testo 327 Flue gas analyser, country-specific version GB Instruction manual

DIGITAL PLATFORM SCALE

Moving money forward UV MG

DMC When Accuracy Counts

Coating Thickness Gauge Model: AX-CTG10 User s Manual

Quick Guide. ICS4 / ICS68_ Weighing systems

DUST FREE ACTIVE Total Home Air Purification

Accent Floor Heating. Tmat System Installation Manual. Floor heating system

testo 175-T1 testo 175-T2 1 channel temperature logger with internal sensor 2 channel temperature logger with internal sensor/external probe socket

Table Of Contents 1 Introduction Safety notes Description of machine Setting up the machine... 10

INSTALLATION INSTRUCTION IM 317 E

Instruction Manual ODY-1765

LEISTER WELDMAX Mini-Hand Extruder

Elcometer 118/2. Moisture Meter. Operating Instructions

1. About this edition of the operating manual

OCEANA AMPHIBIOUS RC DRONE

DS-520 Digital Indicator Operation Manual 73366

Acoustic Wood Ceiling & Wall Panel - Product Information and Data Sheets

OPERATING MANUAL. Conveyor belts. CB-/B-Conveyor

Subfloor heating and cooling instructions for Hakwood flooring products Duoplank 20mm (¾ ) and Duoplank 15mm (⅝ )

SAWDUST MOISTURE METER WTR-1E USERS MANUAL

Product certification HEAT-TREATED TIMBER TR

user guide CME4 concrete encounter 06/2014

Construction. Solvent free elastic adhesive for wood flooring. Product Description 1 1/6

PK-110. User Manual. American Weigh Scales. PK-110 (0-44lb x 0.05lb / lb x 0.1lb)

Transcription:

testo 616 Materialfeuchte-Messgerät Material moisture measuring instrument Appareil de mesure de l'humidité des matériaux. Bedienungsanleitung Instruction manual Mode d emploi

Content 17 Content General notes...18 1. Safety instructions...19 2. Intended purpose...20 3. Product description...21 3.1 Display and control elements...21 3.2 Voltage supply...22 3.3 Humidity measurement procedure...22 4. Commissioning...23 5. Operation...23 5.1 Switching the instrument on/off...23 5.2 Switching the display light on/off...24 5.3 Performing settings...24 6. Measuring...25 7. Care and maintenance...27 8. Questions and answers...28 9. Technical data...28 10. Tips and assistance...29 11. Accessories/spare parts...29 nl sv pt it es fr en de

18 General notes General notes This chapter provides important advice on using this documentation. This documentation contains information that must be applied if the product is to be used safely and efficiently. Please read this documentation through carefully and familiarize yourself with the operation of the product before putting it to use. Keep this document to hand so that you can refer to it when necessary. Identification Representation Meaning Comments Warning advice: Warning! Read warning advice carefully and take the precautionary measures indicated! Serious physical injury could occur if you do not take the precautionary measures indicated. Warning advice: Caution! Read warning advice carefully and take the precautionary measures indicated! Slight physical injury or damage to equipment could occur if you do not take the precautionary measures indicated. Note Offers helpful tips and information., 1, 2 Objective Denotes the objective that is to be achieved via the steps described. Where steps are numbered, you must always follow the order given! Condition A condition that must be met if an action is to be carried out as described., 1, 2,... Step Carry out steps. Where steps are numbered, you must always follow the order given! Text Display text Text appears on the instrument display. Taste Control key Press the key. - Result Denotes the result of a previous step. Cross-reference Refers to more extensive or detailed information.

1. Safety instructions 19 1. Safety instructions This chapter gives general rules which must be followed and observed if the product is to be handled safely. Avoiding personal injury/damage to equipment Do not use the measuring instrument and sensors to measure on or near live parts. Never store the measuring instrument/probe together with solvents and do not use any desiccants. pt it es fr en de Product safety/preserving warranty claims Operate the measuring instrument only within the parameters specified in the Technical data. Always use the measuring instrument properly and for its intended purpose. Do not use force. Do not expose handles and feed lines to temperatures in excess of 70 C unless they are expressly permitted for higher temperatures. Temperatures given on probes/sensors relate only to the measuring range of the sensors. Open the instrument only when this is expressly described in the documentation for maintenance and repair purposes. Carry out only the maintenance and repair work that is described in the documentation. Follow the prescribed steps when doing so. For safety reasons, use only original spare parts from testo. Ensure correct disposal Take faulty rechargeable batteries/spent batteries to the collection points provided for them. Send the product back to testo at the end of its useful life. We will ensure that it is disposed of in an environmentally friendly manner. sv nl

20 2. Intended purpose 2. Intended purpose This chapter gives the areas of application for which the product is intended. Use the product only for those applications for which it was designed. Ask testo if you are in any doubt. The product was designed for the following tasks/applications: Fast and non-destructive evaluation of material moisture courses in woods and building materials. Does not replace reference methods such as CM method or Darr-Wäge (dry-and-weigh) method. The instrument is not calibratable. The product must not be used in the following areas: Areas at risk of explosion. Materials subject to electrical voltage. Electric shock! If in doubt, check whether the materials are energized before the measurement (e.g. in the event of water damage in walls)

3. Product description 21 3. Product description This chapter provides an overview of the components of the product and their functions. 3.1 Display and control elements it es fr en de Overview Contact plates Display Control keys Battery compartment (rear) Key functions Key Functions Switch instrument on; switch instrument off (press and hold) Switch display light on/off Keep reading, display maximum/minimum value Open/leave configuration mode (press and hold); In configuration mode: Confirm input In configuration mode: Increase value, select option In configuration mode: Decrease value, select option nl sv pt Important displays Display Meaning Battery capacity (bottom right in display): 4 segments in the battery symbol are lit: Instrument battery is fully charged No segments in the battery symbol are lit: Battery is almost spent

22 3. Product description 3.2 Voltage supply Voltage is supplied by means of a 9 V monobloc battery (included in delivery) or rechargeable battery. It is not possible to run the instrument from the mains supply or charge a rechargeable battery in the instrument. 3.3 Humidity measurement procedure The non-destructive stray field measurement uses the ability of water molecules to dampen and thus change electromagnetic fields. The electric field penetrates the material via the contact plates and creates a measuring field with a depth of approx. 5 cm (2 ). The following factors can influence the measurement result: Factors Measurement depth Material surface Material properties Moisture distribution Metals and electric fields Ideal condition Material thickness > 5 cm (> 2 ). Caution: The upper layers of the material influence the measurement result more than the deeper layers. As level as possible as contact plates should lay flat against it. As homogeneous as possible with no air pockets. As even as possible. None, if possible.

4. Commissioning 23 4. Commissioning This chapter describes the steps required to commission the product. de en fr Removing the protective film on the display: Pull the protective film off carefully. Inserting a battery/rechargeable battery: 1 To open the battery compartment on the rear of the instrument, push the lid of the battery compartment in the direction of the arrow and remove it. 2 Insert a battery/rechargeable battery (9 V monobloc). Observe the polarity! 3 To close the battery compartment, replace the lid of the battery compartment in position and push it against the direction of the arrow. es it pt sv nl 5. Operation This chapter describes the steps that have to be executed frequently when using the product. 5.1 Switching the instrument on/off Switching the instrument on: Press. - The current reading is shown Switching the instrument off: Press and hold (for approx. 2 s) until the display goes out.

24 5. Operation 5.2 Switching the display light on/off Switching the display light on/off: The instrument is switched on. Press. 5.3 Performing settings 1 To open configuration mode: The instrument is switched on and is in measurement view. Hold, Max or Min are not activated. Press and hold (for approx. 2 s) until the display changes. - The instrument is now in configuration mode. You can change to the next function with. You can leave configuration mode at any time. To do so, press and hold (for approx. 2 s) until the instrument has changed to measurement view. Any changes that have already been made in configuration mode will be saved. 2 To set Auto Off: Configuration mode is opened, AutoOff is flashing. Select the desired option with / and confirm with : on: The measuring instrument switches off automatically if no key is pressed for 10 min. Exception: A recorded reading is shown on the display (Hold or Auto Hold is lit). off: The measuring instrument does not switch itself off automatically.

6. Measuring 25 3 To reset: Configuration mode is opened, RESET is lit. Select the desired option with / and confirm with : no: Instrument is not reset. Yes: Instrument is reset. The instrument is reset to the factory settings. - The instrument returns to measurement view. it es fr en de 6. Measuring pt sv This chapter describes the steps that are required to perform measurements with the product. Setting the material characteristic curve: 1 Switch between the display of wood moisture (F) and building moisture (M): or press. 2 Select the desired option with or and confirm with : Display Category Example F 1 Softwood lumber Spruce, larch, cherry, pine, poplar, meranti F 2 Hardwood lumber Beech, oak, maple, ash, Douglas-fir, walnut, birch F 3 Chipboard M 1 Cement screed M 2 Anhydrite screed M 3 Concrete M 4 Solid brick M 5 High-insulating brick M 6 Limestone M7 Gas concrete CAL Testing characteristic Not for on-site measurements! nl

26 6. Measuring Taking a measurement: The instrument is switched on and is in measurement view. Hold instrument horizontal to contact surface. Slowly increase contact pressure to 1 to 3 kg until a stable value is shown In order to be able to evaluate a moisture course, several measurements at different positions or at different times are necessary. In drying processes, the displayed measurement values can in individual cases also be negative. This occurs as a result of the material composition and the different moisture gradients. When negative measurement values are displayed, the drying process is nearly finished, i.e., the more negative the values, the drier the material. For better assessment of the contact pressure, the instrument can initially be pressed against a scale. Keep reading, display maximum/minimum value: The current reading can be recorded. The maximum and minimum values (since the instrument was last switched on) can be displayed. Press several times until the desired value is displayed. - The following are displayed in turn: Hold: The recorded reading Max: Maximum value Min: Minimum value Current reading Resetting the maximum/minimum values: Switching the instrument off and on again resets the maximum and minimum values.

7. Care and maintenance 27 7. Care and maintenance This chapter describes the steps that help to maintain the functionality of the product and extend its operating life. de en fr Cleaning the housing: Clean the housing with a moist cloth (soap suds) if it is dirty. Do not use aggressive cleaning agents or solvents! Changing the battery/rechargeable battery: The instrument is switched off. 1 To open the battery compartment on the rear of the instrument, push the lid of the battery compartment in the direction of the arrow and remove it. 2 Remove the spent battery/rechargeable battery and insert a new battery/rechargeable battery (9 V monobloc). Observe the polarity! 3 To close the battery compartment, replace the lid of the battery compartment in position and push it against the direction of the arrow. es it pt sv nl

28 8. Questions and answers 8. Questions and answers This chapter gives answers to frequently asked questions. Question Possible causes Possible solution is lit (bottom right Instrument battery is Replace instrument in display). almost spent. battery. Instrument switches Auto Off function Switch function off itself off. is switched on. Residual capacity Replace battery of battery is too low. Display reacts Ambient temperature Increase ambient sluggishly is very low. temperature. Display: uuuu Permitted measuring range Keep to permitted was undershot. measuring range. Display: oooo Permitted measuring range Keep to permitted was exceeded. measuring range. If we could not answer your question, please contact your dealer or testo Customer Service. Contact details can be found on the guarantee card or on the Internet under www.testo.com. 9. Technical data Characteristic Values Parameters Water content in weight percent of dry mass Measuring ranges Woods: < 50 % Building materials: < 20 % Resolution 0.1 % Probe Contact plate (integrated) Measuring rate 0.5 s Operating temperature 5 to 40 C (41 to 104 F) / 10 to 80 %RH Storage temperature -20 to 70 C (-4 to 158 F) Voltage supply 1x 9 V monobloc battery/rech. battery Life 60 h Protection class IP30 EC Directive 2004/108/EC Warranty 2 years (excepting wearing parts)

10. Tips and assistance 29 10. Tips and assistance Typical values for equilibrium moisture (air dryness in building materials 1 and woods). Material Softwood lumber Hardwood limber Chipboard Cement screed Anhydrite screed Concrete Solid brick High insulating brick Limestone Gas concrete Material moisture 9 ± 3 % by weight 9 ± 3 % by weight < 8 % by weight < 3 % by weight < 0,5 % by weight < 2,2 % by weight < 1 % by weight < 2,5 % by weight < 1,3 % by weight < 5 % by weight 1 In ambient conditions 20 C and 65 %RH nl sv pt it es fr en de 11. Accessories/spare parts Designation Article no. Case 0516 0210 For a complete list of all accessories and spare parts, please refer to the product catalogues and brochures or look up our website at: www.testo.com

30 Notes