Techniques for Measuring Oil in Water

Similar documents
Determination of Hydrocarbons in Environmental Samples with Spectrum Two

Development of an industrial standard method for Total Petroleum Hydrocarbon (TPH) analysis

A NEW APPROACH TO THE DETERMINATION OF OIL AND GREASE IN WATER AND WASTES

InfraCal 2 Analyzer. User s Guide. Model ATR-SP. WilksIR.com

Total Petroleum Hydrocarbons By Gas Chromatography in Colombian Waters and Soils

Utility of Variable Bandwidth Monochromators for Quantification of Fluorescent Probes in Produced Effluent Water

SpeedExtractor E-916 Determination of Total Petroleum Hydrocarbons in Soil, Sediment, and Waste Samples using the SpeedExtractor E /2009

OTC PP. Measuring Oil in Water: A Sanity Check Lew Brown, Mason Ide, and Peter Wolfe, Fluid Imaging Technologies, Inc.

Greenhouse Gas Measurement Technology

Detection, Analysis, and Remote Sensing of Oil Spills

Development of Colorimetric Analysis for Determination the Concentration of Oil in Produce Water

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS IAPMO GUIDE CRITERIA FOR

Industrial Solutions

Hydrocarbon Processing Industry Gas Chromatographs. Standard GC Analyzer Solutions

Improved Gas Chromatograph Method for the Analysis of Trace Hydrocarbon Impurities in 1, 3-Butadiene

Determination of Diesel Range Organics (DROs) Using SPE and GC/FID by Method 8015D*

Carbonyl compounds and VOCs analysis from vehicle exhaust: Conventional and alternative methods of detection, analysis and quantification

How to Choose Proper FTIR Spectroscopic Techniques to Analyze Petroleum Products. Presented by: Dr. Yanqia Wang

DIDANOSINE ORAL POWDER Final text for addition to The International Pharmacopoeia

Determining Diesel and Oil Range Organics in Water using Automated Solid Phase Extraction


City of Muskogee Pollution Control Department POLICY STATEMENT FOR GREASE AND OIL CONTROL

Chambers and Instrumentation CHAMBERS. STORA: 22 m 3 chamber

Fast Detailed Hydrocarbon Analysis by Modified ASTM Method D6730

Hydrocarbons Analysis for Risk Assessment in Polluted Soils

The Importance of High Speed Data Acquisition in the Design and Implementation of GC/MS Applications

SOURCES OF ERROR IN OIL IN WATER MEASURERMENTS AND THEIR IMPACT ON COMPARING OIL IN WATER MONITORS

Chlorinated DNAPL Identification using the Membrane Interface Probe (MIP)

Guide to Measuring Water in Oil

Turnkey configurations for gas chromatographic analysis, including instrumentation, methods, supplies and service. Analysis of Natural Gas

Microwave Pyrolysis of C6 Non-aromatic Hydrocarbons

Automated Solid Phase Extraction of PAH Compounds Utilizing the SPE-DEX 5000

SSENTIALS RESTEK. Must-Have Solutions for Your Lab Leverage 3-in-1 Technology for Outstanding Inertness Low Bleed High Reproducibility

INDUSTRIAL EMISSION MONITORING: METHODS AND EMERGING TECHNIQUES

Orono Spectral Solutions, Inc.

Attenuated Total Reflectance (ATR)

This document is a preview generated by EVS

4002 Synthesis of benzil from benzoin

Final Exam. Physical Constants and Conversion Factors. Equations

Mach-RGA. The Fast Refinery Gas Analyzer. Analyzer

Optimization of Volatile Petroleum Hydrocarbons Analysis by Automated Headspace Using Method Development Tools

Triad Case Studies from the Navy. Tim Shields and Adrianne Saboya U.S.Navy PWC Environmental Department San Diego, CA

2.1 This procedure provides steps and conditions for the determination of Vapor Space Organic Compounds in ground waters, and industrial waste waters.

July 27, A NEW EPA APPROVED METHOD FOR TURBIDITY ANALYSIS 360 x 90, Turbidity Method TURBIDITY MEASUREMENT HISTORY

Research and Reviews: Journal of Chemistry

3015 Synthesis of iodocyclohexane from cyclohexane and iodoform

Optimizing Productivity and Reliability for Monocyclic Aromatic Hydrocarbon Purity Analysis According to ASTM D7504 on the Agilent 8890 GC System

Comparison of Shake and Column Silica Gel Cleanup Methods for Groundwater Extracts to Be Analyzed for TPHd/DRO

Fast Analysis of Extended Natural Gas using the New Transportable INFICON Micro GC Fusion

Standard Test Methods for Aromatics in Mineral Spirits by Gas Chromatography 1

Orono Spectral Solutions, Inc.

GC Troubleshooting. Frank Michel, Katherine K. Stenerson T HCE

1001 Nitration of toluene to 4-nitrotoluene, 2-nitrotoluene and 2,4-dinitrotoluene

A Guide to Oil in Water Monitoring for Environmental Compliance

Field test at Gehrkescher Hof in Wilmshagen/Germany

EPA APPROVED METHOD FOR TURBIDITY ANALYSIS 360 x 90, Turbidity Method 10258

Measurement and Characterization of Tars using the SPA Method

Stack Sampling. requires airflow through the sampling probe to be at the same rate as that flowing in the waste gas stream isokinetic

3005 Synthesis of 7,7-dichlorobicyclo[4.1.0]heptane (7,7-dichlornorcarane) from cyclohexene

SUMMARY OF QUALIFICATIONS

Lecture 7 Water Quality Monitoring: Estimation of fecal indicator bacteria

Spectroscopy Fiber Optic Probes for In-line Analytical Analysis

Determination of organochlorine pesticide residues in eggs by gel-permeation chromatography (GPC) cleanup and GC-ECD

Maximizing Sample Recovery on the ACCQPrep HP125

Resolving False PHC Detections in Crude Contaminated Amazon Rainforest Peat Soils

Crystallization & Filtration

Soil Vapor Surveys for Cost Cutting Site Characterization

Chemical Analysis. DHA Analyzer Family. Optimized Solutions for Detailed Hydrocarbon Analysis. Gas Chromatography. think forward

Protocol for Quantitative Determination of Residual Solvents in Cannabis Concentrates Prepared by: Amanda Rigdon, May 23 rd, 2016

Speaker Biography. Matthew DeVay Quality Assurance Director Trace Analytics

HARNETT COUNTY NC OIL & GREASE CONTROL ORDINANCE

Chem 321 Lecture 23 - Liquid Chromatography 11/19/13

ISO 3656 INTERNATIONAL STANDARD. Animal and vegetable fats and oils Determination of ultraviolet absorbance expressed as specific UV extinction

Investigating the Extraction Efficiency of Dioxins in Several Types of Aqueous Matrices by Automated Solid Phase Extraction Utilizing Disks

Oil & Grease Removal. OWEA Collection System Committee HANDS-ON WORKSHOPS 9/13/07 10/11/07 Tom Horn Industrial Fluid Management, Inc.

Resin screening for solvent impregnated resins in industrial wastewater treatment applications

Hydrogen Generators for Fuel Gas

Analysis of Permanent Gases and Extended Hydrocarbons in Natural Gas and Natural Gas Liquids by Capillary Gas Chromatography

RECOGNIZING that oil refineries are one of the main source of oil discharges,

Residual Solvents in medical cannabis analysis using the SRI 8610C FID GC June 2014

NWTPH-Gx. Volatile Petroleum Products Method for Soil and Water

New advances in mine site gas analysis using gas chromatographs

Gas Chromatography Assignment Chem 543/443

Enhanced biodegradation of carbamazepine after UV/H 2 O 2 advanced. oxidation

Dan Deatsch Thompson Environmental Consulting

Agilent 490 Micro GC. The Measure Anywhere Micro GC February 2011

Identification and determination of PAHs compounds in Anzali International Wetland

Agilent Ultimate Plus Fused Silica Tubing

Development of Tar Removal Technologies for Biomass Gasification using the By-products

LABORATORY á SCALE APPARATUS TO ASSESS FEASIBILITY OF SOIL VENTING PROJECTS Application at the Jet-Fuel Polluted Air Base

Experiment 3: The Chromatography of Organic Compounds

SCION GC Series. The Gas Chromatographers Choice for Separations

SCION GC Series. The Gas Chromatographers Choice for Separations

Module 12: Laboratory Overview Answer Key

Environmental Express. Joe Boyd. Solids and BOD Analyses: Pitfalls and Troubleshooting

Onsite FTIR quantitative analysis of water in mineral-based oils using a novel water stabilization technique

2008 Acid catalyzed esterification of propionic acid with 1-butanol to propionic acid 1-butyl ester

Capillary GC Troubleshooting: a Practical Approach

Monitoring Quality of Wastewater and Storm Water Data Dealing with Multiple Permits, States, and Analytical Laboratories

A Class I Permit is issued to any user who meets any one of the following conditions:

Transcription:

WHITE PAPER Techniques for Measuring Oil in Water Background Oil in water analysis is a global issue that crosses many industries, analytical methods, and regulatory agencies. Due to the negative effects of oil on the environment, there are strict limits on the amounts of oil allowed in water. Failure to meet these limits can lead to heavy fines. While any industry that discharges produced water needs to test for oil in water, their specific needs can differ from industry to industry. The petroleum industry is most concerned with measuring Total Oils and Grease (TOG) in both their upstream and downstream wastewater. For industrial pretreatment of wastewater, public water treatment plants, and most other nonpetroleum industries discharging produced water, it is most important to test for Fats, Oils and Grease (FOG) in their effluent. FOG differs from TOG in that it tends to contain large amounts of animal and vegetable components in the oil. FOG can be especially concerning in effluent streams because it can lead to clogged sewer lines which causes Sanitary Sewer Overflows (SSOs). The people responsible for conducting oil in water measurements understand that the measurement can be quite challenging. Wastewater from different sources can contain many different types of hydrocarbons, each with different chemical make-ups. On top of the lack of chemical uniformity in different oils, there has been a large variety of methods developed to quantify the oil in the wastewater. While none of the following methods is perfect, each will have its own advantages and disadvantages for oil in water analysis.

Techniques for Measuring Oil in Water 2 NON-DISPERSIVE/FIXED FILTER IR ANALYZER Non-dispersive/fixed filter IR analyzers are the most common method used in the field for analyzing oil in water. The use of a fixed filter enables the instrument to be simple, inexpensive and rugged. The technology requires an extraction of the oil in water sample where the solvent used depends on the type of non-dispersive/fixed filter analyzer. The extract is then dried and Figure 2: Infrared Spectrum of mineral oil using a 3.44 µm fixed filter measured on the instrument which uses a filter centered in the region between 3.4-3.5 µm (figure 2). Although the filter is centered over the CH2 absorption peak, the bandwidth of the filter will also allow the instrument to detect the CH3 absorption peak and any aliphatic hydrocarbons attached to aromatic compounds. However, this means that high concentrations of aromatics in the sample will lead to inaccurate results. Currently there are two different types of non-dispersive/fixed filter IR analyzers that are used. Spectro Scientific InfraCal 2 ATR-SP Analyzer Spectro Scientific InfraCal 2 TRANS-SP Analyzer Horizontal Attenuated Total Reflection (HATR) While HATR style instruments do not comply with any international standards, they correlate well with both EPA 1664 and ASTM D7066. Since the procedure is very similar to that of EPA 1664, HATR instruments are commonly used to pre-check the compliance of samples before they are submitted to the EPA. These instruments measure samples by evaporating a portion of the extract on the HATR crystal. This is a simple procedure for non-technical users which has the benefit of using volatile hydrocarbons such as hexane or pentane as the solvent. These volatile hydrocarbons tend to be much less expensive than CFC solvents used on transmission instruments. However, since the method requires evaporation, any volatile hydrocarbons in the oil will not be detected. Transmission Transmission style instruments follow an ASTM accepted method (ASTM D7066) which requires the use of a CFC solvent for extraction. While many CFC solvents have been banned, tetrachloroethylene and S-316 are still allowed for use in oil in water analysis. While these solvents are expensive and not the most environmentally friendly option, they do provide the ability to measure volatile hydrocarbons since the extract is measured directly, as opposed to measuring the residue after the solvent (and any volatile components in the sample) has evaporated. Also, the use of a transmission cell extends the level of detection of the instrument to lower levels of oil in water compared to the HATR instruments. (rugged and simple) Inexpensive equipment Simple sampling procedure Inexpensive solvents Correlates to ASTM D7066 and EPA 1664 Does not detect volatile hydrocarbons Does not comply with any international standards (rugged and simple) Inexpensive equipment Can measure volatile hydrocarbons Complies to ASTM D7066 Solvents are expensive Solvents are not environmentally friendly Sampling procedure is more cumbersome

Techniques for Measuring Oil in Water 3 Methods for Measuring Oil in Water Typical setup for EPA 1664 GRAVIMETRIC ANALYSIS (EPA 1664) Gravimetric analysis measures any material extracted from an oil in water sample by a solvent and is the EPA accepted method (EPA 1664) for oil in water analysis. This means that any industry producing oil in water is required to submit samples for testing by EPA 1664 in order to avoid fines. EPA 1664 requires 1 liter of sample that is acidified to a ph of 2. The sample is then extracted 3 times with hexane and those extracts are combined and dried. The method may also use a solid phase extraction (SPE) where the sample is passed through a specific filter and then the trapped oil is dissolved into hexane. The collected extracts are distilled at 85 C and weighed in order to determine the value. The extracts may also be filtered through silica gel in order to provide a total petroleum hydrocarbon (TPH) value as well. The sample preparation required for gravimetric analysis precludes the use of this technique in the field. This means companies are required to EPA accepted method (EPA 1664) Can use SPE in order to use less solvent Can determine TPH value separately Analysis can only be done in a lab Procedure is long and cumbersome Requires large amount of solvent Expensive and time consuming for companies to send in samples send in samples to a lab which is both time consuming and expensive. While this is acceptable for regulatory agencies, the companies producing oil in water need field methods to keep up operations without delay. www.brown.edu/research/evchem/facilities/shared Agilent GC-FID GAS CHROMATOGRAPHY FLAME IONIZATION DETECTION (GC-FID) GC-FID is an ISO (ISO 9377-2) approved method for the determination of oil in water. Unlike other methods, GC-FID analysis can provide details on different types of hydrocarbons in a sample as well as the total amount of oil in water. The GC-FID method first requires the sample to be acidified and extracted by a solvent (hexane or pentane). The extract is then dried/purified and injected into the GC instrument where a carrier gas moves the extract through the column. Once the GC column separates the different types of hydrocarbons, each type is burned and detected by the Flame Ionization Detector (FID). The sum of all the Provides details on different hydrocarbons present Follows ISO 9377-2 Precise Mainly suitable for lab use Equipment is expensive Equipment requires trained personnel responses from each of the hydrocarbon types is calculated in order to determine the total oil in water. While GC-FID is a precise method for oil in water analysis, it is mainly suitable for lab use due to the expense of the equipment and the need for technical users.

Techniques for Measuring Oil in Water 4 Advanced Sensors UV Fluorescence Analyzer UV FLUORESCENCE UV Fluorescence is a common field technique for oil in water analysis which typically uses either a UV lamp or a Laser Induced Fluorescence (LIF) as a light source. Because it does not require a solvent extraction, the technology is ideal for online analysis of a wastewater stream. UV fluorescence works by illuminating an oil in water sample with UV light. The aromatic hydrocarbons in the sample emit fluorescent light that the instrument can detect. The amount of oil in water in the sample is based on the intensity of the light emitted. Instruments that contain a UV lamp typically use a by-pass stream for analysis, however LIF instruments can Requires no solvent Can be setup as an online system Inexpensive Only detects aromatic hydrocarbons Does not follow any international method use probes that are fitted in-line with the produced water stream so that a by-pass stream is not required. While UV fluorescence is a great technology for detecting aromatic hydrocarbons, it will not detect any aliphatic compounds. Since typical oil in water samples are mainly aliphatic, any change in the ratio of aliphatic to aromatic hydrocarbons can drastically affect the results. QUANTUM CASCADE LASER INFRARED (QCL-IR) Eralytics QCL-IR Analyzer QCL-IR is a new infrared method being used to measure the content of oil in water. This method differs from other technologies in that it is measuring the CH3 absorption peak located in the region 1350-1400 cm -1 (Figure 1). This means that a cyclic hydrocarbon such as cyclohexane can be used as an extraction solvent. The advantage of a cyclic hydrocarbon as a solvent is that it is more environmentally friendly and much cheaper than chlorofluorocarbon (CFC) solvents. The method works by first extracting and drying the oil in water sample with cyclohexane or cyclopentane. The extract is then measured on the instrument and the intensity of the absorbance in the region of 1350-1400 cm-1 is correlated to a concentration value. The extract may also be filtered in order to measure TPH separately. While the measurement in this region of the spectrum allows for more ideal solvents, it limits the instrument to detecting only CH3 compounds. This means that any aromatic or cyclic hydrocarbons in the oil will not be detected. However, most oil hydrocarbons contain CH3 and this method has shown to correlate very well with other international standards such as EPA 1664, ASTM D7678 and ISO 9377-2. Figure 1: Measurement of oil in water by QCL-IR Does not require CFC solvent Can be used in the lab or field Correlates to internationally approved methods Can measure TPH separately Only detects CH3 compounds Does not follow any international standards More expensive than other types of IR equipment

Techniques for Measuring Oil in Water 5 Summary There are several methods available for both laboratory and field analysis of oil in water. The choice of methods depends on budget, location of testing, time, and other factors. The most important thing is to consistently test for the amount of oil in water in your wastewater stream in order to avoid any regulatory fines and prevent potential damage to environment. Resources ASTM International D7066-07: Standard Test Method for dimer/trimer of chlorotrifluoroethylene (S-316) Recoverable Oil and Grease and Nonpolar Material by Infrared Determination EPA Method 1664, revision A (1999): N-Hexane Extractable Material (HEM; Oil and Grease) and Silica Gel Treated N-Hexane Extractable Material (SGT-HEM; Non-polar material) by Extraction and Gravimetry ISO ISO 9377-2:2000 (2000) Water quality determination of hydrocarbon oil index Part 2: Method using solvent extraction and gas chromatography Spectro Scientific One Executive Drive, Suite 101, Chelmsford, MA 01824-2563 978-431-1120 www.spectrosci.com sales@spectrosci.com An ISO 9001:2008 company Copyright 2016 Spectro Scientific. All rights reserved. While every effort is made to assure the information in this document is accurate, Spectro Scientific does not accept liability for any errors or mistakes that may arise. Specifications are subject to change without notice. WP_Measuring Oil in Water_2016-05-03