Cardok Sàrl CP37 CH-1295 Tannay Switzerland Phone:

Similar documents
Cardok Carlift with Rigid Chains Data Sheet

Cardok Carlift Data Sheet

Tender specification KLAUS Multiparking MultiBase U1 EB / MultiBase U1 DB

Data Sheet Wöhr Combilift 552-2,0

PRODUCT DATA kg / 2600 kg

PRODUCT DATA kg / 2600 kg

Data Sheet Wöhr Combilift 552-2,6

Data Sheet WÖHR COMBILIFT 552-2,6

Three-sided barrier compliant to DIN EN ISO Depending on location, design also as wind protection. Clear height (DH) Three-sided barrier

Barrier. Delimitation. Water drainage

Carlift Series PHP 222C

QUADROPARKER SERIES QUADROPARKER N4904 THE IDEAL SOLUTION FOR THE EXTERIORS; ON 4 LEVELS CAR STACKERS

Stack Parking Surface Mounted Stackers

Barrier. Delimitation. Water drainage

PRODUCT DATA kg

Tender specification KLAUS Multiparking MultiBase 2072 outdoor installation EB MultiBase 2072 outdoor installation DB

PE/PH. Product Data Parking Pallet. longitudinally shifting. Parking Pallet PE/PH

KLAUS Multiparking GmbH Hermann-Krum-Straße 2 D Aitrach Fon+49 (0) Fax +49 (0)

Water drainage 11 G82-165/295 G82-165/310 G82-185/310. car height car height height. car height upper (L) G82-185/325 G82-195/315 G82-195/335

PRODUCT DATA kg / 2600 kg

Delta Level 1000 Hinged Lip Pit Mounted & Suspended Frame Dock Leveller

Read Only Copy Not For Distribution. Chapter 17. Private Potable Water Supply Systems 17.1 GENERAL REGULATIONS 17.2 QUANTITY OF WATER REQUIRED

RSA Series Dock Levellers Hinged Lip Suspended Frame. Technical Characteristics nr. 3258

Product Datasheet. Hydraulic Dock Leveller with Telescopic Lip (PT) Load capacity: 150 KN ANSI NORM. Contact:

SECTION The specification section is organized by placing information in three standard parts:

Tender specification KLAUS Multiparking TrendVario 4300

PARKLINE SERIES UNIPARKER N5202 THE SEMI-AUTOMATIC PARKING SYSTEM WITH PIT AND WITHOUT COLUMNS AT THE ENTRY SEMI AUTOMATICS

Reinforced concrete double walls

Introduction. Disclaimer. Table of contents

DOCK LEVELLER USER MANUAL

FLORIM MATERIAL STONES OF CERIM EXTRA-THICK FLOOR

Technical Description For MK-CTX Office Cabins

i. Supplier may visit to the site and get familiarized with the exact requirements

Reinforced concrete double walls

CIBES A 5000 Platform Lift

Available in 5 platform widths from 7'-7" to 8'-11" Available in 2 headroom heights: 5'-9" and 6'-11" Available in 4400 lbs or 5060 lbs load capacity

The better way to build TM. Installation Manual FOUNDATION SIPs & FROST WALLS SIPs

STORM DRAINAGE CHAPTER 11

LOADING DOCK SYSTEMS HIGH SPEED DOORS LIFT TABLES DOCK SHELTERS SECTIONAL DOORS COMPL. FOOD INDUSTRY L O A D I N G D O C K S Y S T E M S

STORM DRAINAGE CHAPTER 11

V1504 VERTICAL PLATFORM LIFT PLANNING GUIDE

With CE certificate EN USER MANUAL BORA-CLEAN FILTER 5

Freight Elevator Series GFM-T

COPYRIGHT C 2008, SHANGHAI ZHONGLU INDUSTRIAL CO., LTD.

FLAT. The system: it supports 3 load classes (A15, B125, C250) in compliance with Standard EN 1433

Freight Elevator Series GFM-T

Adjustable decking pedestals. Technical documentation

CARPARX Pit Construction Guide

SECTION VEHICLE LIFTS. B. Section Basic Electrical Materials and Methods: Power and controls wiring.

Technical Documentation

Product Data TrendVario

ELVORON LU/LA ELEVATOR

Swimspa and fitness pool installation Guide

ADDRESS: 122 LIPSCOMBE ROAD, DECEPTION BAY, QLD,

DRAINAGE GUTTERS FOR DRAIN ASPHALT 2012 TECHNICAL CATALOGUE

SERENUS LULA PLANNING GUIDE

ADVANTAGES THE LIGHTEST FILLING SOLUTION HIGH LOAD-BEARING CAPACITY

The system: it supports 3 load classes (A15, B125, C250) in compliance with Standard EN 1433

Product Systems EXTERNAL WATERPROOFING OF BELOW GROUND CONCRETE WALL & SLAB. AQUAFIN-IC CRYSTALLINE WATERPROOFING Schematic sketches

CORRUGATED DRAINAGE PIPES FOR DRAINING UNDERGROUND AND SURFACE RUNOFF WATER 01 / 2017 CATALOGUE

11. Construction processes and materials Power House Maintenance Building Fuel Treatment Building...

HAZOP Checklist for Sewage Treatment Plant

REQUIREMENTS FOR INDOOR INSTALLATION OF PADMOUNTED TRANSFORMERS

PRODUCT DATA kg / 2600 kg

Limelight Pulse Spa Installation Instructions

Product Selection Guide

V1504 VERTICAL PLATFORM LIFT PLANNING GUIDE

Multilift Vertical Platform Lift OWNER S MANUAL

Underground Exhaust System

DEFENDER. Installation Manual

ESSERGULLY. Safe conventional drainage. Gully systems for flat roofs, balconies and terraces

FirstEnergy Program Overview

VERTICAL RECIPROCATING CONVEYOR HYDRAULIC EQUIPMENTS CONVEYOR

Elevators and Lifts

VERTICAL PLATFORM LIFT PLANNING GUIDE

ELVORON STELLA HOME ELEVATOR

VPL-3200B Residential Vertical Platform Lift Technical Specifications

Division 14 Conveying Systems

Division 16 Sections for electrical service for elevators to and including disconnect and fused switches at machine room.

SECTION OPERABLE ROADWAY EQUIPMENT

RAISED ACCESS FLOOR SYSTEM TECHNICAL SPECIFICATION

NUM THAVEER RUNG. Benefits: Huatong anti-static or conductive raised access floor panels are widely used in computer rooms and clean rooms.

VPL-3300B Commercial Vertical Platform Lift Technical Specifications

SYSTEM 600 BILL CHANGER INSTALLATION INSTRUCTIONS Congratulations...

VPL-3300B Commercial Vertical Platform Lift Technical Specifications rev: (5) ILS-01100

Xtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade)

AQUATEK rainwater harvesting systems can reduce mains water consumption in the average domestic dwelling by up to 50%."

Reinforced concrete slot channel

RAPID-EPS PATENT PENDING

TEMPORARY EDGE PROTECTION SYSTEM DESCRIPTION CTS. Combisafe International AB

ELEVATORS & SERVICE LIFTS FREIGHT HOIST MAST LIFTS FREIGHT HOIST SCISSOR LIFTS ELEVATING DOCK SCISSOR LIFTS DOCK LEVELLERS

Stand construction regulations Horecava 2018:

Xtratherm Thin-R Thermal Liner (XT/TL Grade)

Sump Pumps Office procedures for the Drainage & Grading section

Americans with Disabilities Act Accessibility Survey

Introduction. Disclaimer. Table of contents

SECTION RESIDENTIAL ELEVATOR. (Freedom Green Residential Elevator)

Modular System Advantages

Xtratherm Thin-R Thermal Liner (XT/TL Grade)

ifix INSTALLATION MANUAL PV flat roof installation system Version

Transcription:

CARDOK CARLIFT with Rigid chains technology Very fast access to underground garages Fast, Silent, Discreet, Design, High-Tech Installation to replace an access ramp on private property

Dimensions: (Built to measure, all dimensions (in mm) can be changed and adapted upon request and following acceptance) For lift travel more than 3m we suggest our upper platform with our telescopic pillars. Technical zone: Need to provide a space of min. 2.0m 2 for technical area, accessible at all times for maintenance. When several Cardok systems are installed, one power pack will be sufficient to lift each platform separately. Need to install 1 watertight conduit for electric cables. The min diameter is 80mm (they can be cast in the concrete)

Characteristics: (in mm) Standard option Lower platform load: 3000kg 2000kg / 2500kg / other Upper platform load: 3000kg Static 2000kg / 2500kg / other (Dynamic movement available upon request) Dimensions available for lower platform: 2800 x 5800 mm 2700/3100 x 5000/6000 / other Dimensions available for upper platform: 3000 x 6000 mm 2900/3300 x 5200/6200 / other Available height: 2000-4500mm 4000-15000 / other Lift speed: 0.12m/s 0.15m/s Concrete pit: (built by customer) The thickness of the walls needs to be defined by an engineer depending on the quality of the land. The walls of the pit must be formed of concrete and must to be perfectly flat and vertical without any protrusions. The weight of the entire installation together with the maximum load is borne by the concrete pit floor in 4 areas of 400 x 400mm. The static force of each of them is +30kN. The size can be increased, upon demand. Concrete quality according to the static requirement of the building but for the dowel fastening we require a concrete quality of min. C20/25. It s important to ensure that the pit edge remains watertight to avoid water entering the concrete cast. This can be achieved with asphalt for example. If the land has low permeability we recommend installing a draining system. Provision of a watertight passage is necessary for electrical supply of min. 80mm in diameter. Provision of a watertight passage is necessary for water drainage. (see drainage ) (made to measure, all dimensions can be changed upon request and upon acceptance by Cardok) A1 A2 B C D E F : standard 5860mm : standard 2900mm : standard 2500-4500mm : standard 600mm

People transport: In option we can design the CarLift with the EN81 norm for people transport inside the car. Drainage: (to be performed by the customer) A circular gutter system around the upper platform will prevent water entering the pit. Need to install draining pipes in each corner. For locations with particularly exposed conditions we recommend an additional drainage changed around the outside pit. Need to install a drainage grid at the bottom of the pit. Where this is not possible, it s necessary to create a slope and a drainage area to install a small sump pump. The necessary dimensions are min 200x100mm and 50mm deep. To prevent any possibility of contamination of the ground water we recommend giving the pit floor an oil resistant coating as a means of protecting the environment and to facilitate cleaning. Installation: The client needs to provide a fixed or truck mobile crane which will serve to install the system in the pit as well as to unload the truck. Min. hook height and weight requirements are 4m / 6t. (Depend of the site configuration) Protection: (to be performed by the customer) It is necessary to install a manual or automatic gate in the underground, coordinated with Carlift to prevent access to the platform when it moves up or down. We recommend fast doors which need only 1.8-4 seconds to lift up. We can also recommend an option with protective bellows installed around the bottom part of the lift. Finish: The finishing of the upper platform is up to the customer s wish and is not included in the price. We recommend a coating matching the surrounding land which can be asphalt, tiles, gravel, grass or aluminium. It must be determined before the system is built as the weight and the thickness of the coating needs to be taken into account. The standard coating will be 40mm thick and its weight will not exceed 70kg/m2. Other options are possible upon request. Electricity: The electrical components supplied by the manufacturer must be connected in accordance with the appropriate wiring diagram and local regulations. 400VAC (without options) 3PH+N+ PE (three-phase current) protected by FI Power electrical motor 18kW to 37kW (depending lift travel and speed) Two electrical boxes must be installed outside with an emergency switch and key push buttons to lift or lower the platform. The boxes must be installed close to the platform. Noise: In option the electric motor can be equipped with a noise protection case. The lifting system does not produce any noise except for some friction noise.

Light: There are 4 LEDs lights installed on the lower platform. If the technical zone is installed away from the concrete pit, it is necessary to install additional lights for maintenance. Ventilation: We recommend providing a ventilation system in consultation with heating/ventilation/air conditioning engineers with the aim of obtaining continuous air exchange, reducing air humidity, preventing condensation and reducing moisture from cars (rain, snow, ice etc.). This helps considerably to reduce or to prevent corrosion and malfunctions due to corrosion. Maintenance: Regular maintenance by qualified personnel can be provided by means of an Annual Service Contract, included during the warranty period (without travel). Temperature: The installation is designed to operate between -5 C and +50 C. Atmospheric Humidity: 50% at +40 C. The electrical control panel must be installed in dry local between +3 C and +30 C Systems are designed for snow load zone II with up to 0.75 kn/m2 in accordance to DIN 1055-5. If the local circumstances differ from the above, please contact us to provide it. Conformity test: All our systems are checked according to EC machinery directive 2006/42/EC and EN 14010. Notes: In case higher loading is required e.g. passage for fire brigade or delivery fuel oil, please contact us. The manufacturer reserves the right to modify or alter above specifications.