Element Z General Design Requirements Room Standards

Similar documents
Element Z General Design Requirements Owner Standards and other Requirements

Accessible Toilet and Bathing Rooms

EVENT 29: November 15, 2017 THE DO-DOs AND DON Ts OF TOILET ROOM DESIGN

ACCESSIBLE REST ROOM Code Requirements

Texas Accessibility Standards for Restrooms

2018 IBC SECTION 1209 DRAFT TEXT Copyright 2017 International Code Council, Inc. SECTION 1209 TOILET AND BATHROOM REQUIREMENTS

Educational Course Application

SUPPLEMENTAL ACCESSIBILITY NO. 4 PLAN REVIEW CHECKLIST

Plan Check No. f) Where only half baths are provided, at least one half bath. g) Carports, garages or parking spaces. (1111B.4.2.

NC State University Design and Construction Guidelines Division 00 Planning & Design Space Planning

PUBLIC RESTROOMS, DESIGN INTENT Los Angeles World Airports

BUILDING/FACILITY ACCESSIBILITY CHECKLIST. Lessee. Lessor

Whitley Shower Locker Toilet Facilities

Element D Services Plumbing

Chapter 11. Dwelling Units and Sleeping Units

AGILITAS Property Development

DEPARTMENT OF PUBLIC SAFETY AND CORRECTIONS. Public Safety Services ADA-ABA COMMENT ASSISTANCE GUIDE

10155 Toilet Compartments

TENANT CRITERIA MANUAL INSERT PHOTO HERE

Alterations, disproportionality, and the 20% rule

University of North Carolina at Charlotte Design and Construction Manual Section 2, Division 11 Equipment SECTION 2 DIVISION 11 EQUIPMENT

SECTION 2 DIVISION 11 EQUIPMENT

STANDARD PLAN RELEASE SUMMARY(SPR) Facilities Management Department

SPACE TYPE: PHYSICAL FITNESS (EXERCISE ROOM)

Universal Design Standards

Site Accessibility Survey & Transition Plan

2013 California Building Code Advisory

Plumbing for People with Disabilities

DRAFT design development presentation. E x i s t i n g M a l l C o n d i t i o n s YOUNKERS COURT TARGET COURT SEARS COURT

RESTROOM/DRINKING FOUNTAIN REQUIREMENTS

Construction Standards PAGE

CITY OF LOS ANGELES. Title 24, California Code of Regulations Accessibility Regulations Supplemental Correction List No. 1 (Effective )

6 Holub Middle School Overall Site Plan Gymnasium Floor Plan Exterior Perspective Before Exterior Perspective - After

ACCESSIBILITY CHECKLIST

PHASE I ACADEMIC BUILDING CORE RENOVATIONS RCNJ Project No C

Division 09 FINISHES TABLE OF CONTENTS

Waikoloa Homesites. Kohala Coast, HI. Outline Specifications. Prepared By: 16 December 15

Facilities Feasibility Study Matthew A. Henson ES Condition Assessment

Nortrax Section David Manchester Road, Ottawa NON-STRUCTURAL METAL FRAMING 16 May 2014 Page 1

SECTION NON-STRUCTURAL METAL FRAMING

Minimum Requirements for Residential Occupancy Codes and FAQs

PROCEDURE PR California Building Code Accessibility Provisions as Alternate Means and Methods. Revised: October 3, 2013

SUBMISSION GUIDE FOR ARCHITECTS

.2 These guidelines should be read with the specific technical sections of McGill s Building Design and Technical Standards.

Facility Assessment Report, Montgomery Independent School District

A. All tackboards shall be mechanically fastened to walls; gluing shall not be allowed.

ACCESSIBILITY CHECKLIST

CITY OF LONG BEACH Department of Development Services BUILDING AND SAFETY BUREAU COMMERCIAL ACCESSIBILITY PLAN REVIEW CHECKLIST

PHYSICAL EDUCATION February 3, 2014

SECTION ALTERNATES

6'-0" G-4 ADJUSTABLE SHELVING 2'-0" 4'-5" MOP SINK STORAGE '-0" 2'-0" 26'-6" G-4 6' X 4' OPENING WITH SHUTTER BASE CABINETS 34" FOR ADA 20'-0"

PHYSICAL EDUCATION September 30, 2010

Design Aid for Barrier-Free Accessibility in Existing Buildings

Successful Restaurant. Accessibility. Accessibility. Did you sign in? Best Practices. Copyright Materials. Course Description

Florida Accessibility Code for Building Construction

DIVISION 10 SPECIALTIES SIGNAGE. A. Design Considerations

SANDTOWN CROSSING PROFESSIONAL OFFICE PARK Atlanta, GA

Budget Estimate Basic Tenant Improvement

PENNSAFE BUILDING INSPECTION SERVICES LLC NEW COMMERCIAL BUILDING UCC PLAN REVIEW HANDOUT AND CHECKLIST

Facilities Feasibility Study Frederick Douglass HS Condition Assessment

GUIDELINES FOR SANITARY DESIGN AND CONSTRUCTION OF MILK PRODUCTS PLANTS (rev )

CONTRACT DOCUMENTS REVIEW PACKAGE CHECKLIST

Incentives for Universal Design

GUIDELINES FOR THE DEVELOPMENT OF UNIVERSALLY DESIGNED UNITS. New Construction & Rehab

INTERIOR ENVIRONMENT

SANDTOWN CROSSING PROFESSIONAL OFFICE PARK Atlanta, GA

ACCESSIBILITY CHECKLIST

Accessible Plumbing Overview

Work Write-Up and Bid Document

SECTION PLASTIC TOILET COMPARTMENTS

Florida Accessibility Code for Building Construction

This section applies to service areas and loading docks for new construction and major renovations.

Memphis-Shelby County Airport Authority Memphis, Tennessee

NOTE: For construction other than new commercial or additions (renovations), only those areas below describing the scope of work will be applicable.

SECTION TOILET COMPARTMENTS SPEC WRITER NOTES:

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

JEFFERSON PARISH SHERIF S OFFICE

6 Bears and a Goat Brewery - Phase I

INFORMATION GUIDE SECOND DWELLING UNITS BUILDING CODE BASICS

Chapter Bottle Filling Stations. Bottle filling stations which shall comply with Sections and

SECTION PREFABRICATED SHOWER COMPARTMENTS

RFP P1319, Cobb Career Academy Questions and Answers

TILE TILE

C. Liquid Chalk Markerboards: Claridge Duracite LCS markerboard in No. 32 White finish on 3/8 inch-particle board.

Gerald Desmond Bridge Replacement

SECTION PLUMBING FIXTURES

CLARIFICATIONS. Item 3. Specification Sections and A. All finish wood shall have sealer coat and two coats of finish material REVISIONS

CITY OF BEVERLY HILLS DEPARTMENT OF COMMUNITY DEVELOPMENT DEVELOPMENT SERVICES DIVISION COMMERCIAL ACCESSIBILITY CORRECTION LIST

Appendix B University of Maine System Design Criteria

COMMERCIAL TENANT IMPROVEMENT PERMIT APPLICATION

PRESENTATION TO THE FARMINGTON CITY COUNCIL FOR THE PROPOSED FARMINGTON CIVIC CENTER EXPANSION SEPTEMBER 20, 2016

B. Surface, partition and recessed mounted toilet and bath accessories indicated on the Drawings and Schedules.

9/10/2009. Objectives ADA SURVEY TRAINING OFFICE BUILDINGS & COUNTY GARAGES. Training Schedule. Key Roles. Key Roles. Major Laws

DALLAS-FORT WORTH INTERNATIONAL AIRPORT

3. 21st Century Learning A. Districtwide Flexible Learning $600,000 Subtotal $600,000

VILLAGE OF MARATHON CITY MARATHON COUNTY WISCONSIN

UCC Permit Application Procedures

University of Toronto Cleaning Specifications

Americans with Disabilities Act Accessibility Survey

Estimate Form for Bathroom Design and Installation

Transcription:

Toilet Room Guidelines PART 1 - GENERAL 1.01 OVERVIEW A. This document provides design and construction criteria for public/patient, and staff toilet rooms at (Owner). PART 2 - DESIGN CRITERIA 2.01 GENERAL A. The 2012 Texas Accessibility Standards (TAS) of the Elimination of Architectural Barriers Texas Government Code, Chapter 469, and 2010 ADA Standards for Accessible Design (SAD) shall be adhered to for accessibility aspects of the design. In cases where requirements of the two Codes differ, the more stringent of requirements which provides compliance with TAS, shall be used. B. Where single-user toilet rooms meeting 1994 TAS requirements are present within a project area, Owner preference is to renovate to provide compliance with 2012 TAS toilet room requirements. Budget constraints and potential reduced functionality of adjacent spaces shall be considered in determining if toilet rooms will be enlarged to meet 2012 TAS standards. Confirm scope of work with Owner s Project Manager. C. Thresholds at entrance doors shall be low profile, solid surface material. Refer to Owner s Installation Detail Typical Restroom Door Threshold available on the Owner s Design Guidelines website: http://www2.mdanderson.org/depts/cpm/standards/details.html D. Refer to Part 4 of this Element for illustrations indicating tile joint layout requirements and special interior finish details at single and multi-user toilet rooms. E. In multi-user toilet rooms, the design shall incorporate features which limit sight lines into the space, and ensure user privacy. Design elements such as vestibules, screen walls, and carefully considered door placement/door swing can provide a measure of privacy. Under no circumstances shall lavatories and urinals be in direct view when the entry door is opened as typically required for passage. When entrance doors must be located adjacent to lobbies, waiting rooms, or other similar non- corridor public spaces, Owner preference is for the use of alcoves or other type of offsets for door placement. F. Where new/additional drinking fountains are required in the scope of work, locate them in close proximity to multi-user toilet rooms whenever possible. Use of hi/low units is preferred over individual drinking fountains. Recessing of units fully into an alcove is preferred in order to maintain usable corridor width. Where use of an alcove is not possible or appropriate, ensure TAS/SAD compliance is achieved through use of an apron at the high, non-accessible unit. G. For toilet room fixtures which are not subject to TAS/SAD, comply with International Plumbing Code (IPC) requirements for minimum stall size and fixture spacing. Plumbing fixture counts shall be based on IPC requirements. H. At accessible stalls, every effort shall be made to provide a design which locates the side grab bar on the wall, in lieu of the toilet partition. ODG041712 1 OF 7

Toilet Room Guidelines I. The distance that each toilet room accessory projects beyond the face of wall must be carefully considered when determining the adequacy of a design, as it relates to clear approach space required by TAS/SAD at doors and fixtures. J. Confirm with the Owner s Project Manager the type of lavatory/sink to be used in the design. Generally, individual wall hung lavatories are used in single-user toilet rooms, and solid surface material sinks and counter tops are provided in multi-user toilet rooms. These general guidelines vary however, depending on location of toilet room and user group. K. Where counter tops with integral sinks are provided, the design shall comply with Owner s Installation Detail, Counter Detail at Toilet available on the Owner s Design Guidelines website: http://www2.mdanderson.org/depts/cpm/standards/details.html L. Owner preference is to locate paper towel dispensers and waste receptacles near lavatories/sinks. Provide multiple dispensers and receptacles when more than two sinks are present. Where recessed motorized paper towel dispensers are used, sound attenuation blankets of minimum 3 thickness shall be provided in the wall surrounding all sides of the unit. M. Use of toilet room doors that swing out into corridors, creating a safety hazard, shall be avoided. If an out-swing corridor door is required, it shall be fully recessed in an offset. Ensure that the type of door lockset specified allows for entry by Owner in instances where the user requires emergency assistance. N. Refer to Design Guideline Elements C3010 Wall Finishes, C3020 Floor Finishes, C3025 Base Finishes, and C3030 Ceiling Finishes for material types at room envelope. O. Refer to the D series Design Guideline Elements for requirements relating to mechanical, plumbing, and electrical work. P. Toilet tissue dispenser mounting location shall be based on Owner s Installation Details. These are available on the Owner s Design Guidelines website: http://www2.mdanderson.org/depts/cpm/standards/details.html Q. Containers for sharps are required to be provided in various toilet rooms. Confirm with Owner s Project Manager and Owner s Environmental Health and Safety group all details regarding the furnishing, placement, installation and types of sharps containers. R. A floor drain shall be provided in multi-user toilet rooms. The slab shall be continuously sloped or dished in the vicinity of floor drain at these rooms. S. Where showers are provided, a drain shall be installed in each shower. The finished floor within showers shall be sloped at ¼ per foot to drain. A worst case location for the shower curtain, which may be attached to an outward curving rod, shall be anticipated when determining the extent of floor area to be sloped to shower drain. Additional floor drain(s) shall be located in adjacent areas so as to remove all water that may escape the shower(s). Owner approval is required for any design that does not provide a depressed slab for purposes of achieving required finished floor slope at both shower(s) and adjacent areas. T. Where operable seats are provided in showers, they shall be the type with outboard, folding legs, capable of supporting a weight of 800 pounds minimum. Cantilever type seats supported solely from the wall shall not be used. ODG041712 2 OF 7

Toilet Room Guidelines PART 3 - SPECIAL CONTRACT DOCUMENT REQUIREMENTS 3.01 GENERAL A. Include all applicable Owner s Installation Details referenced within this Element. B. Develop and include all other installation details required to clearly communicate design intent and insure constructability. C. Obtain approval from Owner s Project Manager/Planner Designer for all finish schedules prior to issuance of Construction Documents. D. Include in the specifications the requirement that Contractor confirm correct slope of floor to drain at toilet rooms and showers has been provided prior to starting installation of tile or other finish material. Include the requirement for leakage (flood) testing of shower pans, as well as membrane water proofing at toilet rooms and showers. PART 4 - INSTALLATION EXAMPLE ILLUSTRATIONS 4.01 TOILET ROOM WALL TILE LAYOUTS/PATTERNS/DETAILS A. Diagram 4.01A ODG041712 3 OF 7

Toilet Room Guidelines Walls at vestibule and nearby are painted. Ceramic Tile is started at/near the toilet fixture wall. The wall opposite the entry door typically receives full height/width accent green tile. The wall behind the toilet fixtures typically receives the accent medallions centered on the wall. PLAN TYPICAL WALL TILE LAYOUT IN TOILET FACILITIES ODG041712 4 OF 7

Toilet Room Guidelines B. Diagram 4.01B Strict adherence to the tile layout (shown at right) should be followed when wall tile is specified in toilet rooms. ELEVATION - TYPICAL WALL TILE LAYOUT C. Diagram 4.01C Center the accent tiles (medallions) on toilet fixture wall with two field (neutral) tiles between each accent (medallion) tile. D. Diagram 4.01D ELEVATION - TYPICAL WALL TILE LAYOUT AT FIXTURE WALL ODG041712 5 OF 7

Toilet Room Guidelines Accent wall tile (medallion) total size is 12 W X 12 H. Outer tile pieces are 3 X 9 and center tile piece is 6 W X 6 H. DETAIL ACCENT WALL TILE (MEDALLION) 4.02 MULTI-USER TOILET ROOM COUNTER TOPS AND INTEGRAL SINKS A. Diagram 4.02A PHOTO - TYPICAL COUNTER TOPS W/ INTEGRAL SINK BOWLS ODG041712 6 OF 7

Toilet Room Guidelines PART 5 - PRODUCTS 5.01 GENERAL A. For all projects (renovation and new), refer to Owner s Interior Finishes Standards. These are available on the Owner s Design Guidelines website: http://www2.mdanderson.org/depts/cpm/standards/interiors.html B. For renovation projects, refer to Owner s Master Construction Specifications. These are available on the Owner s Design Guidelines website: http://www2.mdanderson.org/depts/cpm/standards/specs.html C. Confirm with Owner s Project Manager the specific toilet room accessories to be used, and whether Owner or Contractor will provide/install each item. PART 6 - DOCUMENT REVISION HISTORY Issue Date Revision Description Reviser 12-11-07 Initial Adoption of Element Rev. 1 10-09-08 Added links to Installation Details, Master Construction Specifications and Interior Finishes Standards located on the Owner s Design Guidelines Internet site. Paragraphs 2.01 K., 2.01 P. and 4.01 A. Rev. 2 12-23-08 Added provisions for sharps containers, paragraph 2.01,Q. Added Part 4 Installation Example Illustrations JRC JRC, JT Rev. 3 07-08-10 Renumbered Element from Z2065. DOS Rev. 4 11-22-11 Deleted exclusion of facilities within in-patient rooms in 1.01. Revised 2.01 A, F, G, and I to include ADA. Added 2.01 R and S relating to drains at restrooms and showers. Added 3.01 D to require testing of floor slope and performance of membrane waterproofing. Rev. 5 04-17-12 Revised TAS reference in 2.01 A; Revised 2.01 B in its entirety; Added attenuation requirements in 2.01 L. ; Added 2.01 T. JRC JRC END OF ELEMENT ODG041712 7 OF 7