Excerpts from: International Residential Code 2009

Similar documents
FRAMING INSPECTION GENERAL

WINDOW AND DOOR REPLACEMENT SAMPLE PLAN

CITY OF DANA POINT WINDOW REPLACEMENTS FOR R-3 B030 WINDOWS

General Residential Code Requirements

RESIDENTIAL STAIRWAYS, HANDRAILS,

General Residential Code Requirements

General Residential Code Requirements

311.7 Stairways Width Headroom. Exception: Walkline Stair treads and risers Tread depth.

Inspection Checklist Residential Building Final July 2016

Minimum Requirements for Residential Occupancy Codes and FAQs

BUILDING PERMIT APPLICATION

2018 IRC Sections R303 through R310 Building Planning II

RESIDENTIAL BUILDING REQUIREMENTS

Inspecting the Means of Egress Course

2003 INTERNATIONAL BUILDING CODE 521

STAIRWAYS, HANDRAILS, AND GUARDRAILS (RESIDENTIAL)

EGRESS AZMIR SULTANA NICOLAS MIMU SAKUMA EDWIN VEGA CHAMORRO

CITY OF OCEANSIDE. Single Family Dwelling Stairways/Guards. Informational Bulletin

Section numbers refer to the 2018 International Residential Code (IRC), as modified, unless otherwise noted. Revised Effective Sept.

HOW TO USE THIS GUIDE:

CHAPTER 24 GLASS AND GLAZING

2003 International Residential Building Code

One and Two Family Additions

Visual Interpretation Of The

Adult Family Home Inspections

City of Santa Monica Building and Safety Division

Comparison of the IRC and IEBC in Relation to One- and Two- Family Dwellings and Townhouses

TOWN OF PERINTON 1350 TURK HILL ROAD. FAIRPORT, NEW YORK (585) , Fax: (585) ,

LINCOLN COUNTY REQUIRED INSPECTIONS (Last updated August 23, 2017)

* RESIDENTIAL PLAN REVIEW *

RESIDENTIAL REMODELING AND BASEMENT FINISH

2012 IRC Sections R303 R310 Building Planning II

General Building Information

SUBJECT: NEW 2000 INTERNATIONAL RESIDENTIAL CODE (IRC) DATE:

Village of Lombard Community Development Department/Building Division 255 E. Wilson Avenue Lombard, IL Tel: Fax:

ORDINANCE NO BE IT ORDAINED BY THE GOVERNING BODY OF THE CITY OF MANHATTAN, KANSAS: Section Adoption of the International Building Code.

ARTICLE 12 INTERNATIONAL RESIDENTIAL CODE 2012 International Residential Code Modification Summary (Statutory Authority: 1976 Code Section )

2006 INTERNATIONAL RESIDENTIAL CODE PLAN ATTACHMENT

2015 BUILDING CODES APPENDIX Q TINY HOUSES. Routt County Regional Building Department

GENERAL BUILDING CODE AND ZONING REQUIREMENTS: Post and spread footings shall be designed and constructed below the minimum frost depth of 42 inches

Data Accuracy. Below Ground Finished* Square Footage: Measured below ground level as it appears from the front view of the building.

Doors, Windows, Stairs & Fireplaces Doors Doors Outdoor Entry Outdoor Entry Doors Doors Outdoor Entry Outdoor Entry

Village of Glen Ellyn Basement Remodeling Project Guidelines

Municipal Code of Chicago CHAPTER EXIT REQUIREMENTS

Single Family Dwelling Documents Preparation and Plan Review Guidelines California Residential Code (CRC).

ADDITIONS BUILDING AND ZONING REQUIREMENTS (REVISED 4/22/2008)

Milgard Windows & Doors. Training Module Building Codes and Ratings

EGRESS WINDOWS st Ave. NE East Bethel, MN Phone: (763) Fax: (763)

(Statute, Rule, FBC, Industry) FBC 406.3, see also FBC No provisions in FBC or FS

The permit holder is ultimately responsible for compliance with all aspects of the building code.

Advanced Ventilation for Residential applications FBC Res 2010.

Typical Deck Details. Albemarle County, Virginia. Based on the 2012 Virginia Residential Code

INTERIOR ENVIRONMENT

CTC MEETING #25 CHILD WINDOW SAFETY REPORT

Floor Plan. *The floor plan represents a section view of a residence which has had an imaginary cut made approximately 4 feet above the floor line.

Building Department Informational Handout. Residential Window Replacement Requirements

2012 Code Update Training

-=== Building Safety Departnlent 'Neil Avenue, Room 202 Cheyenne, WY Phone: (307) Fax: (307) RAMPS

Plan Review Checklist-2015 International Residential Code

Report of project list/proposed changes for Dec. 5 and 6, 2017 BCAC face-to-face committee meeting and

Work Group Item Stairways serving an occupant load of less than 50 shall have a width of not less than 36 inches (914 mm).

Appendix GENERAL INFORMATION TECHNICAL INFORMATION BUILDING CODES INDEX

CODE COMPLIANCE GUIDELINE GENERAL BUILDING

Stairs have many potential violations this Newsletter is Part 1 of two parts.

Standard for Bleachers, Folding and Telescopic Seating, and Grandstands

Typical Deck Details. Shenandoah County, Virginia. Based on the 2012 International Residential Code

Typical Deck Details. Shenandoah County, Virginia. Based on the 2012 Virginia Residential Code

Screen & 3-Season Porches

&02.1. Level 3 Alterations. Level 3 Alterations shall comply with Sections & and &

HILLSBOROUGH TOWNSHIP CODE ENFORCEMENT

BASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/6/2018)

Typical Finished Basement Details

IRC 2015 Significant Changes

APPLICATION NUMBER:, TAX MAP KEY: STREET ADDRESS:, PRPOJECT: APPLICANT:, PHONE NO: MAILING ADDRESS:, FAX NO:

By James Tente, MCP, CBO,CFM

RESIDENTIAL BUILDING CODE HANDOUT REFERENCES: 2015 Michigan Residential Code

Lonsdale Building Inspections Department 415 Central Street W. PO Box 357 Lonsdale, MN (507) fax (507)

Introduction 2 The Guidance Existing Buildings Technical Specifications Materials and Workmanship Interpretation. Part K : The Requirement 3

Residential Deck Guide

R vertical and horizontal.

BUILDING CONSTRUCTION PERMIT PERMIT CONDITIONS AND INSPECTIONS

Width (2012 IRC SectionR ) Exception: The width of spiral stairways shall be in accordance with the section for spiral stairways.

RESIDENTIAL NEW CONSTRUCTION PLAN REVIEW CHECKLIST

Subchapter XI I nstallation of M anufactured Homes SPS Installation standards.

INFORMATION GUIDE SECOND DWELLING UNITS BUILDING CODE BASICS

MEANS OF EGRESS CHAPTER 10

BROCHURE # 108 CONSTRUCTION PLAN COMPONENTS

Pulaski County, Virginia

Americans with Disabilities Act Accessibility Survey

RESIDENTIAL BASEMENT ALTERATIONS GUIDE

INTERNATIONAL CODE INTERPRETATIONS

SUMMARY OF RESIDENTIAL CODE GENERAL PROVISIONS 2004 Florida Building Code

Residential Plan Review for New One and Two Family Dwellings

Charter Township of Garfield Building Department 3848 Veterans Drive Traverse City, MI Telephone (231) FAX (231)

2009 IECC with St Louis Amendments. Fenestration U-factor Skylight U-factor Glazed fenestration SHGC NR 0.

WATERGATE COMMUNITY ASSOCIATION 8 Captain Drive Emeryville, California Office: / Fax: WINDOW REPLACEMENT GUIDELINES

CHAPTER 10 MEANS OF EGRESS

TOWN OF HAGUE GUIDELINES FOR PERMIT APPLICATION

Administrative Changes

Schedule A. a representative appointed from among persons nominated by the Nova Scotia Accessibility Advisory Board.

Transcription:

LUMBER & MILLWORK Excerpts from: International Residential Code 2009 R310.1 Emergency escape and rescue required. Basements, habitable attics and every sleeping room shall have at least one operable emergency escape and rescue opening. Where basements contain one or more sleeping rooms, emergency egress and rescue openings shall be required in each sleeping room. Where emergency escape and rescue openings are provided they shall have a sill height of not more than 44 inches above the floor. Where a door opening having a threshold below the adjacent ground elevation serves as an emergency escape and rescue opening and is provided with a bulkhead enclosure, the bulkhead enclosure shall comply with Section R310.3. The net clear opening dimensions required by this section shall be obtained by the normal operation of the emergency escape and rescue opening from the inside. Emergency escape and rescue openings with a finished sill height below the adjacent ground elevation shall be provided with a window well in accordance with Section R310.2. Emergency escape and rescue openings shall open directly into a public way, or to a yard or court that opens to a public way. Exception: Basements used only to house mechanical equipment and not exceeding total floor area of 200 square feet (18.58 m2). R310.1.1 Minimum opening area. All emergency escape and rescue openings shall have a minimum net clear opening of 5.7 square feet (0.530 m2). Exception: Grade floor openings shall have a minimum net clear opening of 5 square feet (0.465 m2). R310.1.2 Minimum opening height. The minimum net clear opening height shall be 24 inches (610 mm). International Residential Code Emergency Egress Minimum Opening Size 20 minimum AREA = 5.7 square feet 24 minimum 44 finished floor to top of stool cap maximum The lowest part of the clear opening of the window shall be a minimum of 24 above the finished floor. Finished Floor R310.1.3 Minimum opening width. The minimum net clear opening width shall be 20 inches (508 mm). R310.1.4 Operational constraints. Emergency escape and rescue openings shall be operational from the inside of the room without the use of keys, tools, or special knowledge NOTE: For casement egress sizes refer to product catalogs Excerpts from: State Board of Building Regulations and Standards Massachusetts 8th Edition Building Code EMERGENCY ESCAPE AND RESCUE OPENINGS R310.1 Emergency Escape and Rescue Required. Basements with habitable space and every sleeping room shall have at least one openable emergency escape and rescue opening. Where basements contain one or more sleeping rooms, emergency egress and rescue openings shall be required in each sleeping room, but shall not be required in adjoining areas of the basement. Where emergency escape and rescue openings are provided they shall have a sill height of not more than 44 inches (1118 mm) above the floor. Where a door opening having a threshold below the adjacent ground elevation serves as an emergency escape and rescue opening and is provided with a bulkhead enclosure, the bulkhead enclosure shall comply with 780 CMR 5310.3. The net clear opening dimensions required by 780 CMR5310 shall be obtained by the normal operation of the emergency escape and rescue opening from the inside. Emergency escape and rescue openings with a finished sill height below the adjacent ground elevation shall be provided with a window well in accordance with 780 CMR 5310.2. R310.1.1 Minimum Opening Area. All emergency escape and rescue openings shall have a minimum net clear opening of 5.7 square feet (0.530 m2). 1. Grade floor openings shall have a minimum net clear opening of five square feet (0.465 m2). 2. Double hung windows used for emergency escape shall be permitted to have a net clear opening of 3.3 square feet (0.31 m2) provided that at least one operable sash meets the minimum heightand width required by 780 CMR 5310.1.2 and 5310.1.3 and operational constraints defined by 780 CMR 5310.1.4. R310.1.2 Minimum Opening Height. The minimum net clear opening height shall be 24 inches (610 mm). R310.1.3 Minimum Opening Width. The minimum net clear opening width shall be 20 inches (508 mm). R310.1.4 Operational Constraints. Emergency escape and rescue openings shall be operational from the inside of the room without the use of keys or tools. R303.1 Habitable Rooms. All habitable rooms shall be provided with aggregate glazing area of not less than 8 percent of the floor area of such rooms. Natural ventilation shall be through windows, doors, louvers or other Massachussetts Emergency Egress Minimum Opening Size 36 March 2016 20 minimum AREA = 3.3 square feet D.H. only Casement = 5.7 sq. ft. 24 minimum 44 finished floor to top of stool cap maximum The lowest part of the clear opening of the window shall be a minimum of 18 above the finished floor. Finished Floor approved openings to the outdoor air. Such openings shall be provided with ready access or shall otherwise be readily controllable by the building occupants. The minimum openable area to the outdoors shall be 4 percent of the floor area being ventilated. Exception: 1. The glazed areas need not be openable where the opening is not required by Section R310 and an approved mechanical ventilation system is provided capable of producing 0.35 air change per hour in the room or a whole-house mechanical ventilation system is installed capable of supplying outdoor ventilation air of 15 cubic feet per-minute (cfm) (7.08L/s) per occupant computed on the basis of two occupants for the first bedroom and one occupant for each additional bedroom. 2. The glazed areas need not be provided in rooms where Exception 1 above is satisfied and artificial light is provided capable of producing an average illumination of 6 foot candles (6.46 lux) over the area of the room at a height of 30 inches (762 mm) above the floor level. 3. Use of sunroom additions and patio covers, as defined in Section R202, shall be permitted for natural ventilation if in excess of 40 percent of the exterior sunroom walls are open, or are enclosed only by insect screening

LUMBER & MILLWORK Excerpts from: International Residential Code 2009 and Massachusetts State Building Code One & Two Family Dwelling 8th Edition Garage Fire Doors R302.5.1 Opening protection. Openings from a private garage directly into a room used for sleeping purposes shall not be permitted. Other openings between the garage and residence shall be equipped with solid wood doors not less than 13 8 inches (35 mm) in thickness, solid or honeycomb core steel doors not less than 13 8 inches (35 mm) thick, or 20-minute fire-rated doors. R311.1 Means of egress. All dwellings shall be provided with a means of egress as provided in this section. The means of egress shall provide a continuous and unobstructed path of vertical and horizontal egress travel from all portions of the dwelling to the exterior of the dwelling at the required egress door without requiring travel through a garage. R311.2 Egress door. At least one egress door shall be provided for each dwelling unit. The egress door shall be side-hinged, and shall provide a minimum clear width of 32 inches (813 mm) when measured between the face of the door and the stop, with the door open 90 degrees (1.57 rad). The minimum clear height of the door opening shall not be less than 78 inches (1981 mm) in height measured from the top of the threshold to the bottom of the stop. Other doors shall not be required to comply with these minimum dimensions. Egress doors shall be readily openable from inside the dwelling without the use of a key or special knowledge or effort. R308.4 Hazardous locations. The following shall be considered specific hazardous locations for the purposes of glazing: 1. Glazing in all fixed and operable panels of swinging, sliding and bifold doors. 1. Glazed openings of a size through which a 3-inch diameter (76 mm) sphere is unable to pass. 2. Decorative glazing. 3. Glazing in an individual fixed or operable panel adjacent to a door where the nearest vertical edge is within a 24-inch (610 mm) arc of the door in a closed position and whose bottom edge is less than 60 inches (1524 mm) above the floor or walking surface. 1. Decorative glazing. 2. When there is an intervening wall or other permanent barrier between the door and the glazing. 3. Glazing in walls on the latch side of and perpendicular to the plane of the door in a closed position. 4. Glazing adjacent to a door where access through the door is to a closet or storage area 3 feet (914 mm) or less in depth. 5. Glazing that is adjacent to the fixed panel of patio doors. 3. Glazing in an individual fixed or operable panel that meets all of the following conditions: 3.1. The exposed area of an individual pane is larger than 9 square feet (0.836 m2); and 3.2. The bottom edge of the glazing is less than 18 inches (457 mm) above the floor; and 3.3. The top edge of the glazing is more than 36 inches (914 mm) above the floor; and 3.4. one or more walking surfaces are within 36 inches (914 mm), measured horizontally and in a straight line, of the glazing. 1. Decorative glazing. 2. When a horizontal rail is installed on the accessible side(s) of the glazing 34 to 38 inches (864 to 965) above the walking surface. The rail shall be capable of withstanding a horizontal load of 50 pounds per linear foot (730 N/m) without contacting the glass and be a minimum of 11/2 inches (38 mm) in cross sectional height. 3. outboard panes in insulating glass units and other multiple glazed panels when the bottom edge of the glass is 25 feet (7620 mm) or more above grade, a roof, walking surfaces or other horizontal [within 45 degrees (0.79 rad) of horizontal] surface adjacent to the glass exterior. 4. All glazing in railings regardless of area or height above a walking surface. Included are structural baluster panels and nonstructural infill panels. 5. Glazing in enclosures for or walls facing hot tubs, whirlpools, saunas, steam rooms, bathtubs and showers where the bottom exposed edge of the glazing is less than 60 inches (1524 mm) measured vertically above any standing or walking surface. Exception: Glazing that is more than 60 inches (1524 mm), measured horizontally and in a straight line, from the waters edge of a hot tub, whirlpool or bathtub. 6. Glazing in walls and fences adjacent to indoor and outdoor swimming pools, hot tubs and spas where the bottom edge of the glazing is less than 60 inches (1524 mm) above a walking surface and within 60 inches (1524 mm), measured horizontally and in a straight line, of the water s edge. This shall apply to single glazing and all panes in multiple glazing. 7. Glazing adjacent to stairways, landings and ramps within 36 inches (914 mm) horizontally of a walking surface when the exposed surface of the glazing is less than 60 inches (1524 mm) above the plane of the adjacent walking surface. 1. When a rail is installed on the accessible side(s) of the glazing 34 to 38 inches (864 to 965 mm) above the walking surface. The rail shall be capable of withstanding a horizontal load of 50 pounds per linear foot (730 N/m) without contacting the glass and be a minimum of 11/2 inches (38 mm) in cross sectional height. 2. The side of the stairway has a guardrail or handrail, including balusters or in-fill panels, complying with Sections R311.7.7 and R312 and the plane of the glazing is more than 18 inches (457 mm) from the railing; or 3. When a solid wall or panel extends from the plane of the adjacent walking surface to 34 inches (863 mm) to 36 inches (914 mm) above the walking surface and the construction at the top of that wall or panel is capable of withstanding the same horizontal load as a guard. 8. Glazing adjacent to stairways within 60 inches (1524 mm) horizontally of the bottom tread of a stairway in any direction when the exposed surface of the glazing is less than 60 inches (1524 mm) above the nose of the tread. 1. The side of the stairway has a guardrail or handrail, including balusters or in-fill panels, complying with Sections R311.7.7 and R312 and the plane of the glass is more than 18 inches (457 mm) from the railing; or 2. When a solid wall or panel extends from the plane of the adjacent walking surface to 34 inches (864 mm) to 36 inches (914 mm) above the walking surface and the construction at the top of that wall or panel is capable of withstanding the same horizontal load as a guard. R311.1 and R311.2 R311.1 Means of Egress. All dwellings shall be provided with two means of egress as provided in this section. The means of egress shall provide a continuous and unobstructed path of vertical and horizontal egress travel from all portions of the dwelling to the exterior of the dwelling at the required egress doors without requiring travel through a garage. For townhouses all see the Architectural Access Board s regulations at 521 CMR. Exception. Egress through the secondary egress door, required in subsectionr311.2, may include travel through garage provided the garage has an exit door meeting the requirements of a secondary egress door. R311.2 Egress Door. At least two egress doors shall be provided for each dwelling unit, remote as possible from each other, at the normal level of exit. 1. In multi-level dwellings, including but not limited to townhouse, split-level and raised ranch style layouts, the two separate egress doors requires by 311.2 are permitted to be located on different levels. 2. Where site topography prevents direct access at two remote locations to grade from the normal level of entry, the two separate egress doors required by 311.2 are permitted to be located on different levels. The primary egress door shall be side-hinged, and shall provide minimum clear width of 32 inch (813mm) when measured between the face of the door and the stop, with the door open 90 degrees (1.57 rad). The secondary egress door shall be side-hinged or sliding, and shall provide a minimum clear width of 28 inches (711mm) when measured between the face of the door and the stop, with the door open at 90 degrees (1.57 rad). The minimum clear height of the primary and secondary egress door opening shall not be less than 78 inches (1981mm) in height measured from to of the threshold to the bottom of the stop. Other exterior doors shall not be required to comply with these minimum dimensions. Egress doors shall be readily openable from inside the dwelling without the use of key or special knowledge or effort. March 2016 37

20 Minute Rated Entry Doors LUMBER & MILLWORK Steel ISFD Standard Lock Prep 3'0" - 2 3/4" BS 2'8" - 2 3/8" BS Molded IWFD Standard Lock Prep All Widths 2-3 /8" BS Wood IWFD Standard Lock Prep 3'0" - 2 3/4" BS 2'8" - 2 3/8" BS Garage Fire Doors Flush 6 Panel 4 Panel MHD-2S MHD-2 3/0 2/6 2/8 3/0 Winslow 6PNL20MINSM 4PNL20MINSM 2PNL20MINSM 2/8, 3/0 2/6, 2/8, 3/0 2/8, 3/0 2/8, 3/0 Flat Panel Lincoln Park Logan Rockport Cheyenne Roman Flat Panel Flat Panel F9130 F9244 F9255 1-7/16 Fire Rated Raised Panel Ovolo Sticking F9220 F9282 3/4 Fire Rated Flat Panel Ovolo Sticking R302.5.1 Opening protection: Openings from a private garage directly into a room used for sleeping purposes shall not be permitted. Other openings between the garage and dwelling shall be equipped with either solid wood doors not less than 1-3 /4 inch (45 mm) in thickness or 20-minute fire-rated doors. Self closing devices and fire resistive rated door frames are not required. All door openings between the garage and the dwelling shall be provided with a raised sill with a minimum height of four inches. Local building codes may require self closing hinges and or fire rated jambs. Stock Standard Features for Frame: Primed FJ Jamb & Casing Premium Aluminum Sill Weatherstripped 4 x 4 STD Hinges US4 20 Minute Label Frame 4-3 /4 or 6-3 /4 Wall Thickness These maybe ripped down for narrower jamb requirements. 41 U Value Standard Lock Prep 2-6, 2-8= 2-3 /8 BS 3-0 = 2-3 /4 BS Options: Applied Interior Casings Oak Sill Oak Threshold Aluminum Threshold 1 Way Viewer 4 x 4 Self Closing Hinges Choice of Hardware Color Rough Openings: 2-6 x 6-8 R.O. 32-1 /2 x 82-1 /2 2-8 x 6-8 R.O. 34-1 /2 x 82-1 /2 3-0 x 6-8 R.O. 38-1 /2 x 82-1 /2 Rough opening with carpet shim 83 Label Affixed to Frame March 2016 61

Interior Door Unit Rough Openings Single Door Bi-Fold Slider (Bi-Pass) Pair Cased Double Pocket Door Opening Acting 2-Door Units Specify Left Hand or Right Hand When Ordering * 1-0 14-1/2 1-2 16-1/2 1-3 17-1/2 1-4 18-1/2 1-6 20-1/2 1-8 22-1/2 Left Hand Right Hand 1-10 24-1/2 2-0 26-1/2 *26-1/2 26-1/2 * Available with Ball Catch Roller Latch Magnetic Catch T-Astragal w/ Head & Foot Bolt (must specify handing when ordering w/ T-Astragal) 26 1/2 49 2-2 28 1/2 28 1/2 53 2-4 30-1/2 *30-1/2 30-1/2 * 30-1/2 57 2-6 32 1/2 *32-1/2 32-1/2 * 32-1/2 32-1/2 61 2-8 34-1/2 *34-1/2 34-1/2 * 34-1/2 34-1/2 65 2-10 36-1/2 36-1/2 36-1/2 69 3-0 38-1/2 *38-1/2 38-1/2 * 38-1/2 38-1/2 73 3-4 42-1/2 * 42-1/2 3-6 44 1/2 44-1/2 3-8 46-1/2 * 46-1/2 3-10 48-1/2 4-0 50-1/2 49-1/2 50-1/2 * 4-4 53-1/2 54-1/2 * 4-8 58-1/2 57-1/2 58-1/2 * 5-0 62-1/2 61-1/2 62-1/2 * 5-4 66-1/2 65-1/2 66-1/2 * 5-8 69-1/2 70-1/2 * 6-0 74-1/2 73-1/2 74-1/2 * * Note: Add 7/16 to UD unit pair when using T-AST In between sizes also available 50-1/2 96 54-1/2 104 58-1/2 112 62-1/2 120 66-1/2 128 70-1/2 136 74-1/2 144 Interior Doors R311.2.1 Interior Doors: All doors providing access to habitable rooms shall have a minimum nominal width of 30 inches and a minimum nominal height of six feet six inches. 1. Doors providing access to bathrooms are permitted to be 28 inches in nominal width. 2. Existing Buildings: Doors providing access to bathrooms are permitted to be 24 inches in nominal width. Rough Opening Formula Add to Door Width Add to Door Height Interior Door 2-1/2 2-1/2 Bi-Fold 2-1/2 2-1/2 Slider (Bi-Pass) 1-1/2 2-1/2 Unit Pair 2-1/2 2-1/2 Cased Opening 2-1/2 2-1/2 Pocket Door Single (Door Width x 2) + 1 4-1/2 Pocket Door Pair (Door Width x 4) 4-1/2 * All pre-hung door units are built with a 1-1 /8 clearance at the bottom of the door. 62 March 2016

Attic Scuttle R-6.7 Attic Scuttle 1" Foil/Foam BD 1/2" MDO PANEL 5 4-8 " 7 2-8 " Panel Options: 1/2" Oak 1/2" Birch 1/2" Bead Board Features for all Scuttles: 1/2 Primed MDO Panel Single Rabbet Jamb Compression Weather-stripping Casing 4 Sides (Picture Frame) Order by Rough Opening Maxmium Size is 80 U.I. U.I. = Sum of 1 Width & 1 Length CODE = APS R - 18.6 Attic Scuttle R-18.6 Attic Scuttle 3" 5-1/2" R - 37.2 Attic Scuttle R-37.2 Attic Scuttle 6" 9-1/4" R-55.8 Attic Scuttle R - 55.8 Attic Scuttle 9" 11-1/4" Access Panel 5 4-8 " 1/2" MDO PANEL Features: 1/2 Primed MDO Panel 4-5/8 Finger Joint Primed Jamb Wood knob Lift & Pull to remove panel Order by Rough Opening 36 maxium width CODE = APS 41 maxium height Access to crawl spaces: Access shall be provided to crawl spaces by an opening not less than 18 inches by 24 inches. Options: Foam Insulation Board 1" = R 6.75 2" = R 12.9 4" = R 25.8 Weather-stripping Panel Options 1/2" Oak 1/2" Birch 1/2" Bead Board Casing Option 3 sides 4 sides R807.1 Attic Access. An attic access opening shall be provided to attic areas that exceed 30 square feet and have a vertical height of 30 inches or greater. The rough-framed opening shall not be less than 22 inches by 30 inches and shall be located in a hallway or other readily accessible location. A 30-inch minimum unobstructed headroom in the attic space shall be provided at some point above the access opening. See 780 CMR 6305.1.3 for access requirements where mechanical equipment is located in attics. All attic access doors, trap doors, etc., separating conditioned from unconditioned space shall be fitted with suitable gaskets, weather strips, etc., and fit and close tightly to ensure minimal air leakage between conditioned and unconditioned space (also see 780 CMR 61.00). 78 March 2016

36 6 8 Width Minimum width of stairs is normally 36. These codes usually do not include handrail projections, which are discussed at right. Note: For two people to pass comfortably and for allowance of the passage of furniture, 42 or wider stairs are recommended. Rail must be continous on full length of stairway. Headroom Minimum headroom codes vary but are generally measured vertically from the lowest portion of the ceiling to a point along the imaginary line connecting the tread nosings. C Hand Rail A 6" 6" B C A Winder A. Width of the tread at a point not more than 12 from side where tread is narrowest must be equal to the tread depth of a straight run tread. B. The minimum depth of any tread is no less than 6. C. The continuous rail must be on the side where the treads are narrowest. D. Rail must be continuous. E. Within any flight of stairs, the largest winder tread depth at 12 walk line shall not exceed the smallest by more than 3/8. Always check and understand local building codes before specifying ANY stair parts. 80 March 2016

Building Code Stairways 43/8 4 Min 36 Min 34 Max 38 Max 1-1/4 IRC MA Code 10 Min 9 Min Run Rake Rail Height Rake rail heights are measured from top of the leading edge of the nosing to the point at the top of the rail directly above. Baluster Spacing A sphere 4-3/8 in Dia. cannot pass through. Balcony Rail Height Balcony rail heights are measured from the finished floor surface to the top of the level rail. Baluster Spacing A sphere 4 in Dia. cannot pass through. IRC 7-3/4 Max MA Code 8-1/4 Max Rise The individual rise measurement of a stair is measured from tread surface to tread surface. Some codes continue by specifying the greatest individual rise within any stair should not exceed the smallest by more than 3/8. Individual tread run measurements are from riser line to riser line and do not include the overhang portion of the tread. In addition, most codes require a 3/4 to 1-1/4 tread overhang. Individual measurements of tread run (as well as measurements of tread overhang) cannot vary by more than 3/8 from the smallest to largest. Handrail Grip Size Round Rail 6 Min. 1-1/4 Dia. Max. 2 Dia. Min 1-1/2 Max 4-1/2 Profile Rail Max. Diameter 2-3/4 2 3/4" A related sphere code relates to a stair that uses shoe rail on an open stair. The size of the triangle formed by the tread, risers, and the bottom of the shoe rail is also governed by a sphere size, usually 6. Handrail Projection Projection of the handrail into the stair, measured from the edge of the rail to the wall, is generally listed at a maximum of 4-1/2. Handrail Clearance Handrails adjacent to a wall require a space between the wall and the handrail (usually not less than 1-1/2 ). This distance must also be kept between a handrail that passes the landing tread of a balcony rail section that returns on the stair. Always check and understand local building codes before specifying ANY stair parts. March 2016 81