Quick-Start Operating Guide Document No Process Gas Cooler Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010

Similar documents
92831 TEL: (714) FAX:

92831 TEL: (714) FAX:

Installation Guide Document No Transaction Windows Copyright 2017 Terra Universal Inc. All rights reserved. Revised October 2017

Installation Guide Document No BioSafe Cleanroom Windows Copyright 2017 Terra Universal Inc. All rights reserved. Revised December 2017

92831 TEL: (714) FAX:

Quick-Start Operating Guide Document No Exhaust Fume Hood Copyright 2010 Terra Universal Inc. All rights reserved. Revised September 2010

Installation Guide Document No Fire-Rated Pass-throughs Copyright 2017 Terra Universal Inc. All rights reserved. Revised Sept.

Installation and Operating Guide Document No SmartDesiccator Copyright 2017 Terra Universal Inc. All rights reserved. Revised February 2017

92831 TEL: (714) FAX:

Smart WhisperFlow Document No Horizontal Laminar Flow Station Copyright 2016 Terra Universal Inc. All rights reserved. Revised April 2016

92831 TEL: (714) FAX:

Quick-Start Operating Guide Document No ValuLine Vertical Laminar Flow Station

92831 TEL: (714) FAX:

Quick-Start Operating Guide Document No Explosion-Proof Hood Copyright 2014 Terra Universal Inc. All rights reserved.

CONTENTS. Safety Storage Cabinet Features 3. Model. Warranty 12. Flammable Safety Cabinets 5. Corrosive Safety Cabinets 6

TL-600 MOBILE PHASE HEATER

Thermoelectric Cooler

Thermoelectric Coolers. All Models INSTRUCTION MANUAL. Rev. G 2016 Pentair Equipment Protection P/N

CONTENTS. Wet Scubber Features 3. Parts 4. Models 6. Technical Specification. Warranty MiniLab 7 - MaxiLab MaxiLab

3601 E. 34th St. Tucson, AZ USA Tel Fax Web:

10810 W. LITTLE YORK RD. #130 - HOUSTON, TX VOICE (713) FAX (713) web: IMPORTANT!!!

10810 W. LITTLE YORK RD. #130 - HOUSTON, TX VOICE (713) FAX (713) web: IMPORTANT!!!

Owner s Manual & Safety Instructions

FROST TOP - WF SERIES

Beach House Cargo Lifts Branded Product of Cargo Lift Distributors

OWNER S MANUAL SERIES MDS-96-BK, SM, DR

OWNER S MANUAL SERIES MDS-96-BK, SM, DR

Installation, Operating and Maintenance Instructions Incognito Series Air Curtain

4300 WINDFERN RD #100 HOUSTON TX VOICE (713) FAX (713) web: twrlighting.com IMPORTANT!!!

OPERATION AND INSTALLATION MANUAL

INSTALLATION PROCEDURE

6 Closet light. Model Due to continuing improvements, actual product may differ slightly from the product described herein.

10810 W. LITTLE YORK RD. #130 - HOUSTON, TX VOICE (713) FAX (713) web: IMPORTANT!!!

OptoLum MegaLine RGBW Luminaire

Maintenance Bypass Breaker Cabinet Series Configuration 5. Installation and Operation Manual

PD6770 VANTAGEVIEW LOOP-POWERED PROCESS METER

Maintenance Bypass Breaker Cabinet Series Configuration 2. Installation and Operation Manual

MTTC User Manual. Innovative Technology for a Connected World. General Description. Specifications and features

3M Water Filtration Products Model SGLP-RO Reverse Osmosis System- Quick Installation Guide

Rocker Tool Post ASSEMBLY AND OPERATING INSTRUCTIONS

V 2.0 ASSEMBLY GUIDE. TS Platform Scale Series 2

VWR Zero Air Generator Models , Installation, Operation, and Maintenance Manual. Bulletin TI-ZAG3500-L1466

MODELS MB1K-1, MB1K-2 MB2K-1, MB2K-2 MB3K-1, MB3K-2

OPERATOR S MANUAL Model 56A Prefeed / Dereeler

Installation and Operation Manual

T1000 Transformer INSTRUCTION SHEET. for Magnetic-Field Susceptibility Testing. Features

PAGODA SERIES OPERATOR'S MANUAL

4 rotary milling table

Drag Chain Conveyor Installation and Operation Manual

CONTENTS. Standard Hood Features 3. Laboratory Fume Handling 4. Stainless Steel Fume Hood -AD Series 5. Models 6. Parts 7. Options and Accessories 8

Ecologix Environmental Systems, LLC

MODEL LMO-P MINI PROOFER INSTALLATION, OPERATION & MAINTENANCE MANUAL RETAIN THIS MANUAL FOR FUTURE REFERENCE

DRYWALL DOLLY 900 LB. CAPACITY

Dynatronics Parallel Bars

INSTALLATION PROCEDURE

WheelTime Exchange Standard Terms and Conditions. ZF Services North America, LLC (ZFSNA) 9/1/2015 ZF SACHS Heavy Duty Clutch and Shocks

New Advanced Environmental Air Treatment System

L505 VISUAL LEVEL INDICATOR. Dip-Tape Visual Level Indicator INSTALLATION AND OPERATIONS MANUAL

7 PIECE TUBE FLARING KIT

Miniglaze/2. Owner & Operator's Manual PORCELAIN STAINING AND GLAZING FURNACE. Model No: Voltage: V 50/60Hz V 50/60Hz

Precision Automatic Vacuum Control (PAVC+)

Mechanical Post Lift. Owner s Manual

Hayward Flow Control

INSTALLATION PROCEDURE

Stainless steel rolling cabinet

C60 Standby UPS. 800VA Models. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

Introduction TMD Warnings and Cautions Caution: Caution: Caution: Caution: Caution: Caution: Modification

User Manual. PAT-Stand-16 Docking Station. Release 1.3. November EL-CELL GmbH

REF DOC # STANDARD IMAGING, INC Murphy Drive Middleton, WI TEL TEL FAX

Carbon Canister Vapor Polisher

USER'S GUIDE TO OPERATION

NOVELLA. Installation Instructions for Wall Mount Lavatory with Corner Cabinet and Storage System INTRODUCTION

1-300 SERIES Endover Rotator Operator s Manual for Morse End-Over-End Drum Rotators Series

Standard Hood Features 3. Laboratory Fume Handling 4. Walk In Fume Hood -AD Series 5. Models 6. Technical Specification 7. Options and Accessories 8

LOAD RAMP 1000 LB. CAPACITY

LIGHT CONTROLLER LC 500

Gerber Scientific Products

KPHE20 SERIES WATER-TO-AIR HEAT EXCHANGER

CFL Series User Manual

Mobile Hot Food Merchandiser Series. Series: MM Operation Manual

STEEL PIPE NIPPLES SEAMLESS Price Sheet PNS-9.16C Effective: September 5, 2016 Cancels Price Sheet PNS-10.15C of October 5, 2015

Sby SR Instruments, Inc.

8 DIAL CALIPER. Model Diagrams within this manual may not be drawn proportionally.

Miniature Helium Purifier and Nitrogen Purifier Instruction Manual

MODEL GEK E3 Guard Enclosure Kit. Operator s Manual for Morse Guard Enclosure Kit Model GEK E3 for Can Tumbler Model E3

MODEL GEK E1 Guard Enclosure Kit. Operator s Manual for Morse Guard Enclosure Kit Model GEK E1 for Can Tumbler Model E1

Gerber. Scientific Products. Dear Gerber Sabre Customer:

SUBJECT ADTC TO U11 CONTROLLER FIELD RETROFIT

Wash Down Duty Non-Contact Sensor

POWER PINNER BENCH HAND WELDER 7250 OPERATOR S MANUAL

Model 3185E DUAL TONE DECODER INSTRUCTION MANUAL

78-RK VARIABLE SPEED HEAVY DUTY VIBRATOR OPERATING MANUAL

XBDM-HW63. 63A Model. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

CONTENTS. Standard Hood Features 3. Laboratory Fume Handling 4. Polypropylene Fume Hood -AD Series 5. Models 6. Parts 7. Options and Accessories 8

Owner s Manual & Safety Instructions

Dancer Duty Potentiometer

Model 292A. Surface Resistance Test Kit. Instruction Manual

Quick Start Guide WaveMaster

KNHE20 SERIES WATER-TO-AIR HEAT EXCHANGER

DIAPHRAGM BRAKES MODELS ''J'' AND ''K''

Transcription:

Document No. 1800-56 Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010 Terra Universal, Inc. TerraUniversal.com 800 S. Raymond Ave. Fullerton, CA 92831 TEL: (714) 578-6000 FAX: (714) 578-6020

Proprietary Notice This manual pertains to proprietary devices manufactured by Terra Universal, Inc. Neither this document nor any portion of it may be reproduced in any way without prior written permission from Terra Universal. Safety Notice A thorough familiarity with all operating guidelines is essential to safe operation of the product. Failure to observe safety precautions could result in poor performance, damage to the system or other property, or serious bodily injury or death. Terra Universal makes no warranties applying to information contained in this manual or its suitability for any implied or inferred purpose. Terra Universal shall not be held liable for any errors this manual contains or for any damages that result from its use. CAUTION Cautions are used when failure to observe instructions could result in significant damage to equipment. The following symbols are intended to call your attention to two levels of hazard involved in operation: The information presented here is subject to change without notice. WARNING Warnings are used when failure to observe instructions or precautions could result in injury or death. 1.0 Introduction This manual provides information on installing and operating your Terra. By studying this document carefully, you can be assured of a long, efficient service life from your system. 2.0 Description Terra Universal s cools compressed air to within the range of 35 to 50 F, condensing the water vapor in the compressed air to form liquid. Removal of water vapor allows you to keep any airoperated device cool, reducing down-time and maintenance. s work best when sized close to the rated load for cubic feet per minute. (See Section A for controller operation). Air Inlet Air Outlet 5 Pin Din Socket Fig. I: System Connections Sensor Probe Power Cord Terra Universal, Inc. TerraUniversal.com 800 S. Raymond Ave. Fullerton, CA 92831 TEL: (714) 578-6000 FAX: (714) 578-6020 2

The comes complete with a temperature controller with digital LCD readout and 3/8" compression inlet/outlet fittings for gas tubing. GAS IN COOLANT GASTO CABINET PROCESS GAS COOLER SENSOR IN CABINET CABINET 1/8" fitting threaded into cabinet wall Temperature Probe inside cabinet Compression nut Probe Cable to cooler Fig. II: Sensor WARNING: Do not exceed pressure rating of cooler, nor any air system component Do not exceed 120 F inlet air to this cooler Before installation, repair or maintenance of this cooler or component, release all pressure Disconnect electrical power source before repairing or maintaining this cooler Terra Universal, Inc. TerraUniversal.com 800 S. Raymond Ave. Fullerton, CA 92831 TEL: (714) 578-6000 FAX: (714) 578-6020 3

Standard equipment is supplied w/nema electrical enclosures and is not intended for installation in hazardous environments Air treated by this equipment may not be suited for breathing without further purification. Refer to OSHA Std. 1910.134 TO REMOTE ALARM HICH TEMP WARNING R FAN SWITCH ON/OFF SWITCH POWER G FAN OVERLOAD L LINE 1 2 ON/OFF SWITCH RELAY M S GROUND START CAPACITOR S L R Fig. IlI: Wiring Diagram COMPRESSOR TERMINLS 3.0 Installation Note: Before installing Terra Universal's, carefully unpack the unit and check for signs of damage or missing parts. Any damage should be reported immediately to the freight company. Plug the power cord into an electrical outlet and make sure that the controller "ON" indicator lights up. 1. Care should be taken in placement of compressor intake to avoid introduction of contaminants. 2. Install cooler in an area that allows air to pass through the refrigeration section. Ambient temperatures as high as 110 F can be tolerated, but capacity will be reduced 6%. Coolers should not be operated in ambient temperatures below 35 F. 3. Installing the sensor requires that a 1/8" NPT stainless steel fitting first be threaded into the enclosure wall, near the gas exhaust or RB valve. Install the sensor as shown in Figure 2 above. Terra Universal, Inc. TerraUniversal.com 800 S. Raymond Ave. Fullerton, CA 92831 TEL: (714) 578-6000 FAX: (714) 578-6020 4

Checkpoints 1. Condensation is being discharged to the drain. After several hours of operation, some sign of condensation discharge should be visible. 2. Green power light is illuminated. 3. Red high temperature warning light is out. The red light is a high-outlet air temperature warning light. When the light is ON the temperature of the air leaving the cooling coil is higher than normal. When the air is cooled down satisfactorily, the red light will be OFF, usually in 30 minutes. If it comes back ON after being off for several hours of normal continuous operation, one of the following conditions could be the cause: a. The unit is overloaded. b. The refrigeration section of the cooler may have lost refrigerant. c. The unit is functioning normally, but the thermostatic switch is malfunctioning or has lost contact with the copper tubes 4. A hot by-pass valve installed in the refrigeration systems controls the pressure on the suction side. This allows the refrigeration system to run continuously. 4.0 Specifications Model 3Z528 Flow capacity 35 F 10 SCFM 50 F 16 SCFM For use with Air Compressor size 2 & 3 HP Max. working pressure 175PSG Max. Inlet temp. 120 Air connection inlet/outlet 3/8 SS bulkhead compression fitting Horse power 1/6 Electric rating 115V, 60 Hz, 1 phase Full load amps, 115V 3.4 Locked rotor amps, 115V 18.5 Recommended fuse protection Overload protection (Auto reset) 15 AMPS Thermal and current Dimensions 16 1/4 x 15 x 14 Weight 57 lbs. Terra Universal, Inc. TerraUniversal.com 800 S. Raymond Ave. Fullerton, CA 92831 TEL: (714) 578-6000 FAX: (714) 578-6020 5

5.0 Warranty Products Manufactured by Terra: Terra Universal, Inc., warrants products that it manufactures to be free from defects for a period of 12 months for parts and 90 days for labor, commencing from the date of shipment. Terra s sole responsibility is to repair or replace, at its option, any part of the product that proves defective or malfunctioning during this time limit. In some cases, components incorporated in Terra Universal products are covered by additional warranties from component manufacturers; obtain specific information from Terra sales representatives. This warranty is void if the equipment is abused or modified by the customer, is operated outside Terra s operating instructions or specifications, or is used in any application other than that for which it is specified. This warranty does not include routine maintenance or service procedures, breakage of quartz baths after 60 days, shipping damage, nor damage from misuse, intentional or unintentional abuse, neglect, natural disasters, or acts of God. Products Manufactured by Others: Terra Universal, Inc., warrants that, to the best of its ability, Terra s representations of products that are manufactured by others reflect the manufacturer s representations, subject to change without notice. Sole warranty for these products is the original manufacturer s warranty that is passed forward to the purchaser and constitutes the customer s sole remedy for these products. Detailed warranties for distributed products are available through Terra sales representatives. Freight Shortage or Damage: Upon receipt of any equipment from Terra Universal, Inc., customer shall immediately unpack and inspect for damage or shortage. The customer shall not accept a damaged package or a short shipment until the carrier makes a "damage or shortage" notation on both the carrier's and customer's copy of the freight bill or delivery receipt. Service title passes when the shipment is loaded, so customer is responsible for filing and collecting a freight claim. Any replacement products must be ordered and paid for separately. For Terra's "Policy and Procedures for Returning Goods," see Terra's Internet site: www.terrauniversal.com. Generally, customers can improve the chance of collecting on a freight claim by following these procedures: 1) formally requesting that the carrier inspect the shipment immediately upon suspecting damage or shortage to verify condition; 2) notifying the carrier upon discovery of concealed damage and requesting an inspection within 15 days of receipt, both in person or phone and following up via mail; 3) keeping the shipment as intact as possible, including retaining original packaging materials and keeping the product as close to the original receiving location as possible; 4) holding salvage for disposition by the carrier. All Claims: Terra Universal expressly disclaims all other warranties, expressed or implied or implied by statute, including the warranties of merchantability or fitness for intended use. Terra Universal is not responsible for consequential or incidental damages arising out of the purchase or use of the products supplied by Terra Universal. Terra Universal is not liable for damage to facilities, other equipment, products, property or personnel of others, or of their agents, suppliers, or affiliated parties, which is caused or alleged to have been caused by products supplied by Terra Universal. In any event or series of events, Terra Universal s total liability for any and all damages whatsoever is limited to the lesser of the actual damages or the original invoice cost of the items alleged to have caused the damage. The customer s sole and exclusive remedy for any cause of action whatsoever is repair or replacement of the non-conforming products or refund of the actual purchase price, at the sole option of Terra Universal. All claims must be made in writing within 90 days of the date the product was shipped. Any claims not made within this time limit shall be deemed waived by the customer. Terra Universal is not responsible for any additional costs of repair caused by poor packaging or in-shipment damage during return. Warranty Returns: All warranty returns must be authorized in advance by Terra Universal and approved under an RMA. Unless approved in advance for good reason, all returns must be in original condition, including all manuals, and must be packaged in original packaging materials. All returned goods are to be shipped to Terra Universal, freight prepaid at customer s expense. See Terra s Policy and Procedure for Returned Goods. Thank you for ordering from Terra Universal! Terra Universal, Inc. TerraUniversal.com 800 S. Raymond Ave. Fullerton, CA 92831 TEL: (714) 578-6000 FAX: (714) 578-6020 6

Terra Universal, Inc. TerraUniversal.com 800 S. Raymond Ave. Fullerton, CA 92831 TEL: (714) 578-6000 FAX: (714) 578-6020 7