Energy self-sufficiency as a feasible concept for wastewater treatment systems

Similar documents
Integration of Wastewater Treatment Plants into Regional Energy Supply Concepts

THE DEMON ANAMMOX PROCESS: RESOURCE SAVINGS THROUGH SIDE STREAM TREATMENT, AND THE STEPS TOWARDS AN ENERGY NEUTRAL WWTP PRESENTED AT: NC AWWA-WEA 97

THE ENERGY AUTONOMOUS SEWAGE TREATMENT PLANT ONCE A DREAM, NOW A REALITY

Feedforward aeration control of a Biocos wastewater treatment plant

Post-Aerobic Digester with Bioaugmentation Pilot Study City of Meridian, ID WWTP PNCWA 2010

Discussion about Cause of Nitrous Oxide (N 2 O) Emission in Wastewater Treatment Plant, Based on Long-Term Continuous Measurement

Carbon Heat Energy Assessment and. (CHEApet) Tutorials: Carbon Footprint Primer

A Battle to Be the Best: A Comparison of Two Powerful Sidestream Treatment Technologies: Post Aerobic Digestion and Anammox

INFLUENCE OF ACTIVATED SLUDGE SRT ON ANAEROBIC EXCESS SLUDGE DIGESTION

ENHANCING THE PERFORMANCE OF OXIDATION DITCHES. Larry W. Moore, Ph.D., P.E., DEE Professor of Environmental Engineering The University of Memphis

Introduction to the Energy performance and Carbon emissions Assessment and Monitoring Tool (ECAM-Tool)

(c) Tertiary Further treatment may be used to remove more organic matter and/or disinfect the water.

Biological Phosphorous Removal Is Coming! Michigan Water Environment Association Annual Conference, June 23, 2008; Boyne Falls MI

Optimisation of the WWTP performance and design using computer simulation

Managing the Risk of Embracing Disruptive Technology

CSR Process Simulations Can Help Municipalities Meet Stringent Nutrient Removal Requirements

Sludge ozonation and intermittent aeration through the OSCAR controller: A combined strategy for OPEX minimization in wastewater treatment

Resource recovery from waste and wastewater «new» challenge for the cities

Efficient Design Configurations for Biological Nutrient Removal

AMMONIACAL NITROGEN REMOVAL FROM SLUDGE LIQUORS OPERATIONAL EXPERIENCE WITH THE DEMON PROCESS

Removal of High C and N Contents in Synthetic Wastewater Using Internal Circulation of Anaerobic and Anoxic/Oxic Activated Sludge Processes

FROM ENERGY CONSUMING TO ENERGY PRODUCING WASTEWATER TREATMENT PLANTS. VIENNA MAIN WASTEWATER TREATMENT PLANT (VMWWTP) AS AN EXAMPLE

Solved scaling problems for implementing deammonification of rejection water

Innovative Use of Dissolved Air Flotation with Biosorption as Primary Treatment to Approach Energy Neutrality in WWTPs

Nitrogen Removal in Large Scale Plants. Dimitri Katehis PhD, PE

OPERATING RESULTS FROM THE FIRST FULL SCALE AEROBIC GRANULAR SLUDGE NEREDA PLANT EPE WWTP

Shortcut Biological Nitrogen Removal for sustainable wastewater treatment and achieving energy neutrality

Carbon Redirection and its Role in Energy Optimization at Water Resource Recovery Facilities

FEASIBILITY REPORT OF 250 KLD SEWAGE TREATMENT PLANT

IWA TG on Benchmarking of Control Strategies for WWTPs How to generate realistic input data?

Department of Civil Engineering-I.I.T. Delhi CVL723 Problem Set_2_Feb6_15

JEDDAH INDUSTRIAL CITY

Innovations in Nitrogen and Phosphorus Removal

Application of the AGF (Anoxic Gas Flotation) Process

Towards energy neutrality of wastewater treatment plants via deammonification process

NEW BIOLOGICAL PHOSPHORUS REMOVAL CONCEPT SUCCESSFULLY APPLIED IN A T-DITCH PROCESS WASTEWATER TREATMENT PLANT

SIMPLE and FLEXIBLE ENERGY SAVINGS And PERFORMANCE ENHANCEMENT for OXIDATION DITCH UPGRADES

SBR PROCESS FOR WASTEWATER TREATMENT

Emerging Issues in the Water/Wastewater Industry. Austin s Full-Scale Step-BNR Demonstration

PHOSPHORUS RECOVERY FROM SEWAGE SLUDGE USING THE AQUACRITOX SUPERCRITICAL WATER OXIDATION PROCESS

New Developments in BioWin 4.0

Feasibility Report on Sewage Treatment Plant (STP)

SIMULATING THE EFFECTS OF INTRODUCTION OF MEMBRANE FILTRATION AT A MUNICIPAL BNR PLANT

ADVANCING NOVEL PROCESSES FOR BIOLOGICAL NUTRIENT REMOVAL

Modelling of Wastewater Treatment Plants

Greenhouse Gas Emissions From Wastewater Treatment A Comprehensive Review

AMPC Wastewater Management Fact Sheet Series Page 1

AMPC Wastewater Management Fact Sheet Series Page 1

HWEA Conference March 16, 2010 ThermAer : A New Day for ATAD Thermal Process Systems

PROCESS SIMULATOR FOR WASTEWATER TREATMENT PLANT

Energy management at Sundet WWTP

Colsen Group 2012

Filtrate Treatment Facility Update

Optimization of Anaerobic Digestion with Bio- Organic Catalyst Compositions (BOCs)

Discussion Paper for a Wastewater Treatment Plant Sector Greenhouse Gas Emissions Reporting Protocol

Municipal Wastewater Engineering

CTB3365x Introduction to Water Treatment

Anaerobic process. An introduction. Ecochemicals UAB

Improving energy efficiency in waste water treatment: What emerging countries can learn from experience gained in the developed world

ETHANOL DOSING OPTIMISATION IN BIOREACTOR. Blake Schneider. Blake Schneider, Duty Operator, Thakshila Balasuriya, Process Engineer, City of Gold Coast

Technologies for Sustainable Wastewater Treatment. Nitrogen Removal from Sludge Dewatering Liquor

Advances in Multiobjective Optimization In Practice

TWO YEARS OF BIOLOGICAL PHOSPHORUS REMOVAL WITH AN ADVANCED MSBR SYSTEM AT THE SHENZHEN YANTIAN WASTEWATER TREATMENT PLANT

Andrea Nifong, World Water Works (formerly HRSD) Stephanie Klaus, VT & HRSD

CASE STUDY: BREAKTHROUGH CENTRATE TREATMENT AT REDCLIFFE WASTE WATER TREATMENT PLANT

Renovation of secondary treatment facility into the Step-feed Biological Nitrogen Removal Process by the effective use of the existing structure

ANNEXES WASTEWATER TO ENERGY

WP 3.3: Policy Roadmap for large-scale biogas implementation in Latvia

Southside Wastewater Treatment Plant Renewable Energy Leasing Project

BOOSTING ENERGY PRODUCTION THROUGH CO-DIGESTION

Contents General Information Abbreviations and Acronyms Chapter 1 Wastewater Treatment and the Development of Activated Sludge

WWTP Side Stream Treatment of Nutrients Considerations for City of Raleigh s Bioenergy Recovery Project. Erika L. Bailey, PE, City of Raleigh

Impacts of blackwater co-digestion upon biogas production y in pilot-scale UASB and CSTR reactors

Six years of experience with N 2 O emission from wastewater treatment

Presentation Outline

Waste water treatment

Applications of Variable Environmental Conditions on Biological Sludge Production in Wastewater Treatment

Struvia Technology for Phosphorus Recovery. o Re-Water Braunschweig November 2015

Efforts for use of methane gas in wastewater treatment of Japan

ONSITE TREATMENT. Amphidrome

Covered Anaerobic Ponds for Anaerobic Digestion and Biogas Capture: Piggeries

A Study on the Use of Sewage Treatment Plant as a Base for Circulation of Materials and Energy

Altoona Westerly Wastewater Treatment Facility BNR Conversion with Wet Weather Accommodation

COMPARISON OF SBR AND CONTINUOUS FLOW ACTIVATED SLUDGE FOR NUTRIENT REMOVAL

Advanced Oxidation Ditch Process and Screw Press Dewatering

OPTIMIZATION OF AN INTERMITTENTLY AERATED AND FED SUBMERGED MEMBRANE BIOREACTOR

Environmental Biotechnology Cooperative Research Centre Date submitted: March 2008 Date published: March 2011

Proprietary AquaTron technology incorporates three (3) innovative features that increase its efficiency and reduces cost:

2017 Annual Performance Report

Estimation of Carbon dioxide and Methane Emissions Generated from industrial (WWT) plants

Deammonification for Cost-Effective Sidestream Treatment

concep pts and results Heidelberg-Neurott Dipl.-Wirtsch.-Ing. Tosca Zech, Dipl.-Ing. Marius Mohr

Aerobic biological treatment of thermophilically digested sludge

BIOLOGICAL WASTEWATER BASICS

Adaptating dynamic simulation to a wastewater treatment plant reconstruction

NITROGEN REMOVAL GRANT WEAVER, PE & WWTP OPERATOR PRESIDENT THE WATER PLANET COMPANY. Create Optimal Habitats

Biothane Anaerobic Technology Memthane 2.0 WATER TECHNOLOGIES

Upgrading Lagoons to Remove Ammonia, Nitrogen, and Phosphorus *nutrient removal in cold-climate lagoon systems

An Innovative Approach to Retrofitting for Nitrogen Removal

The Fate of Ammonia in Facultative Lagoon Sludge Treatment Processes: An Investigation of Methods for Reducing Ammonia in Recycle Streams:

Transcription:

Energy self-sufficiency as a feasible concept for wastewater treatment systems B. Wett*, **, K. Buchauer**, C. Fimml*** * Institute of Infrastructure/Environmental Engineering, University of Innsbruck Technikerstr.13, A-62 Innsbruck, Austria, (e-mail: bernhard.wett@uibk.ac.at) ** ARAconsult, Unterbergerstr.1, A-62 Innsbruck, A, (e-mail: buchauer@araconsult.at) *** AIZ Wastewater Association, Strass 15, A-6261 Strass, A, (e-mail: fimml@aiz.at) Abstract Both cost issues on a microeconomic level and concerns about greenhouse gas emissions on a global level have become major driving forces towards a more efficient usage of energy in wastewater treatment WWT. This presentation describes Central European initiatives for operational optimisations, which came up with average energy saving potentials of about 3-5 % for existing utilities. A close-up on performance data of the WWTP Strass (Austria) is given a case study that demonstrates large-scale feasibility of energy self-sufficiency. An annual net surplus in electric energy of 8 % of the total demand of the plant is fed to the public grid. Following key factors for energy-efficiency have been identified: Two-stage biological WWT optimises the transfer of less stabilised organics from the liquid train to the digesters. On-line control of intermittent aeration for enhanced nitrogen removal reduces demand for air supply. Latest generation of coupled-heat-power plants generates an average yield of 38 % electric power. Finally, deammonification proves highest efficiency for side-stream treatment of sludge dewatering liquors. In total an electricity generation of 11% of the calorific energy captured in influent organics proves to be sufficient to supply the whole plant (i.e. 54 Wh/PE). Key words energy balance, energy efficiency, wastewater treatment, digestion, biogas, Demon INTRODUCTION In general wastewater treatment systems are implemented to reduce harmful emissions to receiving water bodies. So far reductions of fossil energy consumption and greenhouse gas emissions to the atmosphere have been out of scope for wastewater utilities. Now Kyoto and subsequent protocols intend to impact these systems significantly by specific regulations and/or penalties associated with emissions of methane and nitrous oxide (Greenfield and Batstone, 25). Any measures that impose mandatory limitations on the release of greenhouse gases will also impact the operation of treatment facilities. Selection of treatment technology, process operation, post-processing and disposal of residual solids influence the GHG contribution of the wastewater treatment utilities (Keller and Hartley, 23; Insam and Wett, 27). Anaerobic digestion provides an on-site renewable energy source and is widely applied in sludge treatment in medium and large scale plants. The following work puts a focus on energy efficiency of this standard scheme of municipal wastewater treatment biological nitrogen removal BNR and anaerobic sludge stabilisation. Wastewater treatment plants frequently are ranked as the top individual energy consumers run by municipalities. Therefore energy consumption for wastewater treatment is a matter of concern on a microeconomic scale and saving potentials need to be explored. Potential in energy savings in WWTPs Central Europe features several thousand state of the art nutrient removal WWTPs, predominantly activated sludge systems. Given the region s fondness for technical perfection and innovation, it is to assume that energy saving potentials are scarce. Nonetheless, in 1994 the Swiss Ministry for Environment, Forest & Landscape (BUWAL, 1994) published an Energy Manual for WWTPs. And in 1999 the most populous German state of North Rhine Westphalia followed suite with a rather

similar Energy Manual (MURL, 1999). The declared objectives of these efforts are knowledge transfer related to the use of energy at WWTPs, the definition of a standardised approach for energy optimization, a reduction of operation cost and last but not least a reduction of CO 2 emissions. Hence in either case the Energy Manuals include (i) an elaborate manual describing the background of energy consumption at WWTPs, both as what refers to electricity and to thermal energy; (ii) a clear-structured guiding strategy for the implementation of energy optimization at WWTPs. The suggested strategy is a two-stage approach. The first stage represents a screening phase: Operation data is collected and a small number of key parameters are derived thereof. For instance, for large WWTPs MURL (1999) targets electricity consumption according to Figure 1, a specific biogas yield of > 475 l/kg volatile dry solids entering sludge digestion, as well as self-sufficiency for electric and thermal energy of 9% and 99%, respectively. This is not yet complete energy selfsufficiency, but it clearly indicates that full self-sufficiency is not out of reach. 3 optimum target guide number electricity consumption [kwh/pe/a] 25 2 15 1 5 Total Biological stage Figure 1. Targets for electricity consumption at WWTPs according to MURL (1999) The findings of the screening stage often enable the definition of short-term optimization measures, which typically do not even incur any investment cost. Finally, after screening a decision has to be taken on the need for a subsequent more detailed optimization stage. In such a case there will be an in-depth analysis of each and every treatment stage and of all electro-mechanical installations. Both short-, medium- and long-term measures for energy optimization are defined and their respective economic viability is assessed. Now, after about 1 years practical application of these Manuals, a large number of WWTPs has undergone such energy optimizations. And the results are highly surprising: Switzerland (Müller et al., 26): Two thirds of all WWTPs in Switzerland have already undergone energy analysis. Because of that, energy cost has been reduced by an astounding average of 38% so far. 2/3 of this cost reduction is due to increased electricity production from biogas, 1/3 is due to real savings. Major efficiency increases were realised in the biological stage and with improved energy management. Current savings amount to 8 million EUR/a. Over an investment life-span of 15 years this equals 12 million EUR. Germany (Müller and Kobel, 24): So far 344 WWTPs in North Rhine Westphalia (NRW) have undergone energy analysis. And the findings indicate that energy cost can be reduced by an even higher margin than in Switzerland, that is by an average of 5%! Energy optimisation typically proves financially attractive for WWTPs, with potential savings being larger than the required investments. Extrapolation of findings in NRW leads to an overall savings potential in Germany equalling 3 to 4 billion EUR over 15 years.

Austria: There, a somewhat different path has been followed than in the two above cited countries. Austria did not produce another Energy Manual, but instead promoted benchmarking. That is, all existing about 95 WWTPs with a total of about 2 million design PE were invited to take part in a benchmarking process, which annually compares individual cost figures with the overall national performance. Participation is voluntary and any individual data remains unknown to all other participants. Thus a participating WWTP is informed just about its own data in comparison to the overall benchmarks, medians, etc. The first such benchmarks were developed for the year 1999 (LFUW, 21), the latest publicly available data refers to the year 24 (Lindtner and Ertl, 26). The comparison stimulates a kind of competition between WWTPs and the ambition to improve. For practical advice on possible energy optimizations, of course, the Swiss and German Energy Manuals could be used advantageously. Just how much key figures changed within this short 5-year period is depicted in Figure 2. The presented total operation cost numbers include all kinds of operation cost, that is WWTP staff, administration, cost for third parties, chemicals and materials, disposal of sludge, sand and screenings, other cost and not least energy cost. Within that 5-year period the relative contribution of energy cost to the benchmark has shrunk by about 3%, and thus constitutes the single most relevant factor for overall reduction of the operation cost benchmark. Consequently, the median of energy cost for large WWTPs has meanwhile fallen to about 1, EUR/PE/a, with the best performing WWTPs already approaching zero energy cost. 16 14 12 1 8 6 4 2 [EUR/PE/a] 1999 24 median of all participating WWTPs benchmark for large WWTPs Figure 2. Total operation cost for Austrian WWTPs participating in benchmarking [EUR/PE/a] In sum, those allegedly perfect European WWTPs offer an astounding average energy saving potential of about 3-5% without the need to compromise on treatment efficiency. It is hence to assume that the worldwide existing energy saving potential at WWTPs is enormous. In the light of discussions about global warming and a need for reduced CO 2 emissions, thus wastewater treatment definitely is a sector where action is needed, effective and financially attractive. Energy balance of WWTPs It is a known fact that the potential energy available in the raw wastewater influent exceeds the electricity requirements of the treatment process significantly. Energy captured in organics entering the plant can be related to the COD load of the influent flow. Based on calorific measurements presented by Shizas and Bagley (24) a capita specific energy input of 176 kj per PE in terms of 12 g COD of organic matter can be calculated. This specific organic load is subjected to aerobic and anaerobic degradation processes, partly releasing the captured energy. Three different categories of energy from carbo-hydrate degradation are differentiated E T thermal energy, E S syntheses energy and E E electricity.

aerobic metabolism CH 2 O + O 2 CO 2 + H 2 O + E T + E S activated sludge ------------------------------- ------------------------------------------------------------ anaerobic metabolism CH 2 O.5*CH 4 +.5*CO 2 + (E T +E S ) digester ------------------------------- ------------------------------------------------------------ cogeneration in CHP.5*CH 4 + O 2.5*CO 2 + H 2 O + E T + E E CHP Aerobic metabolism yields a large amount of energy which can hardly be put to good use. Syntheses energy generation means high excess sludge production and biogenic heat as a byproduct of microbial growth is consumed for wastewater heating without significant impact due to high dilution. Anaerobic digestion generates much less syntheses energy therefore minor biomass production and less thermal energy, which shows more impact because of high concentrations in the solids train. A major part of the energy content remains captured in methane. This amount of energy is easily accessible for incineration technology and can be transformed by a coupled heat power plant CHP to both electrical and usable thermal energy. These energy products can be recycled to the origin of the process chain and on one hand drive the aeration system and on the other hand heat the digesters. Obviously there are two treatment trains with different metabolism pathways and with different energy yields. The process engineering goal is a diversion of as much organics, i.e. energy, from the aerobic liquid train to the anaerobic solids train. Compliance with nutrient removal requirements remains the overriding objective, of course. In Figure 3 the main energy fluxes separately for calorific and thermal energy related to wastewater, sludge and biogas are displayed. The PEspecific calorific energy input to the plant of 176 kj/pe corresponds to 12 g COD/PE and the thermal energy flux of 141 kj/pe corresponds to 2 L/PE at 16.8 C (see case study Strass). The specific biogas yield from mesophilic digestion is assumed to 26 L/PE (575 kj/pe) and electrical cogeneration efficiency is 38%. The assumed biogas potential equals 33% of the influent calorific energy and electricity 12% of it. Significantly higher heat losses in calorific energy balance in the liquid train of about 22% compared to the digester (3%) underline difference in microbial synthesis. thermal energy balance calorific energy balance E T influent 1%=141kJ liquid train E T effluent 14% E C influent 1%=176kJ liquid train E C effluent 5% 2% 1% 1% 74% E T 1-2% digester heating solids train CHP cogeneration E T export 1-2% E E 11% aeration solids train 33% CHP cogeneration E E export 1% E C solids 37% Figure 3. Flow scheme of the potential calorific and thermal energy content of wastewater in comparison with energy fluxes between the liquid train, the solids train and the CHP, respectively

METHODS Already in the introductory section energy values have been related to person equivalents PE in order to generate comparable performance figures. The same procedure applies to the operational data of WWTP Strass, a case study of an energy balance without relevant sources and demands of extra energy. The plant operators are much aware of measuring electricity consumptions of individual unit processes. Measured states of COD and nitrogen compounds have been analysed by means of the acknowledged biokinetic model ASM1 implemented in the SIMBA process simulator. CASE STUDY WWTP STRASS The municipal WWTP Strass provides a two stage biological treatment (A/B plant) to treat loads varying from 9 to more than 2 PE weekly averages depending on tourist seasons. In total 31 communities are draining their sewage to this plant. The high loaded A-stage with intermediate clarification and a separate sludge cycle eliminates 55-65 % of the organic load. The A-stage is operated at half a day sludge retention time SRT, while in the B-stage the target SRT is about 1 days. N-elimination in the low loaded B-stage is operated by pre-denitrification to achieve an annual N-removal efficiency of about 8 % at maximum ammonia effluent concentration of 5 mg/l. All activated sludge tanks can be aerated for maximum load flexibility of the system. Airflow and aeration periods are controlled by on-line ammonia measurement. Figure 4 resumes the COD fluxes between the main subsystems of the treatment plant Strass. influent A-stage B-stage effluent SBR thickener dewatering digester biosolids Figure 4. Simulated COD-balance of the WWTP Strass based on a 2 weeks measurement campaign in summer 24 (average load 119866 PE 12COD ; average flow 23771 m 3 /d; Temperature 16.8 C). Maximum transfer of organics to digesters The biological 2-stage approach supports high-rate entrapment of organics without excessive aerobic stabilization. Within a hydraulic retention time.5 hours organic compounds are removed mainly by adsorption and rapidly introduced to thickening and digestion. In the B-stage a minimum SRT is required in order to establish a stabile population of nitrifying organisms. Aeration energy demand depends on F/M ratio, which again is governed by excess sludge flux to the digesters. Figure 5 depicts the correlation between increasing F/M ratio, decreasing energy demand for air supply and higher specific biogas yield (see fall 24). F/M ratio obviously does not exhibit a stringent control pattern and the model predicts a saving potential of 3% in case minimum SRT depending on temperature is properly adjusted.

[kg COD/kg VSS], [m3/kg VSS] 1..9.8.7.6.5.4.3.2.1. 1/1/4 F/M ratio specif.gas-yield specif.energie B 31/1/4 1/3/4 31/3/4 3/4/4 3/5/4 29/6/4 29/7/4 28/8/4 27/9/4 27/1/4 26/11/4 26/12/4 2 18 16 14 12 1 8 6 4 2 [Wh/PE] Figure 5. F/M ratio in [kg COD per kg aerobic VSS] is plotted against specific aeration energy demand and the biogas yield. Intermittent aeration controlled by on-line effluent ammonia Air supply needs to be governed by nitrification performance while heterotrophic growth should be predominantly based on nitrate reduction. That is why aerated reactor volume is stepwise increased on costs of denitrification volume depending on the actual load. Intermittent aeration is operated between two set-points of the on-line ammonia control strategy leading to extended aeration intervals in the afternoon (in Figure 6 DO of 2 mg/l in aeration zones of circulation tanks partial depletion in-between). In case ammonia concentration continues to climb to the maximum threshold value the complete denitrification volume gets aerated. Nitrogen profiles in Figure 6 indicate stable low ammonia (right top) and fluctuating nitrate in the effluent (right bottom). Figure 6. Simulated DO-profile during one day of on-line ammonia controlled intermittent aeration and dynamics in ammonia and nitrate concentrations during a 14 days run.

[kwh/d] 1, 9, 8, 7, 6, pumping station mechanical treatment A-stage SBR-reject water B-stage sludge treatment off-gas treatment buildings total consumption electricity production 8,848 8,241 8,377 8,461 8,422 8,6 7,65 7,869 7,359 7,154 95 77 1,1 1,15 1,1 1, 95 1,25 1,5 8 5, 4, 3, 3,632 3,424 3,432 3,38 3,684 4,221 4,45 3,862 3,951 3,53 2, 272 35 317 363 285 444 367 41 196 1, 751 818 691 767 864 85 847 99 764 758 1996 1997 1998 1999 2 21 22 23 24 25 Figure 7. Energy demand of individual unit processes of the WWTP Strass. High electrical efficiency from cogeneration In average the electricity demand of the B-stage is still the biggest player representing 47% of the total consumption (Figure 7). Relatively high consumption rates for influent pumping (9%) and for off-gas treatment (13%) due to site constraints should be noted. The percentage of energy selfsufficiency was steadily improved starting from 49% in 1996 to 18% in 25 by many individual measures. A big step forward in energy production was the installation of a new 8 cylinder CHP unit which provides power of 34 kw in 21. The data in Figure 8 shows an increase in gas production due to higher load and corresponding reduction in digester s SRT, while the specific gas yield was maintained fairly constant. This high gas yield of about 26 L/PE is converted to electrical energy by the CHP unit at an average efficiency of 38%. 1 total gas production specif.gas yield CH4 content retention time SRT 5, 4,5 specific gas yield [L/PE], SRT [d] 8 6 4 2 average 25.7 L/PE 4, 3,5 3, 2,5 2, 1,5 1, total gas yield [Nm³/d] 5 Jan-96 Jul-96 Jan-97 Jul-97 Jan-98 Jul-98 Jan-99 Jul-99 Jan- Jul- Jan-1 Jul-1 Jan-2 Jul-2 Jan-3 Jul-3 Jan-4 Jul-4 Jan-5 Jul-5 Jan-6 Jul-6 Figure 8. Specific biogas yield and methane content in correlation with retention time. Energy savings from side-stream treatment Probably the most significant individual optimisation step regards the side-stream treatment for filtrate from sludge dewatering. From 1997 to 24 a SBR-strategy for nitritation/denitritation was

operated and excess sludge of the A-stage served as a carbon source. Then the DEMON -process for deammonification without any requirements of carbon (Wett, 26) was implemented. Higher portion of high-rate sludge in the feed to the digesters increased the methane content from about 59 to 62%. The total benefit in terms of savings in aeration energy and additional methane sums up to about 12% of the plant-wide energy balance (Wett and Dengg, 26). Wh/PE 1 9 8 7 6 5 4 3 2 1 production [kwh/pe] consumption [kwh/pe] self-sufficiency [%] implementation DEMON Aug. 3 Oct. 3 Dec. 3 Feb. 4 Apr. 4 Jun. 4 Aug. 4 Oct. 4 Dec. 4 Feb. 5 Apr. 5 Jun. 5 Aug. 5 Oct. 5 Dec. 5 Feb. 6 Apr. 6 Jun. 6 Aug. 6 Oct. 6 Dec. 6 Figure 9. Percentage of plant-wide energy self-sufficiency as the difference of demand and production of electrical energy after implementation of deammonification CONCLUSIONS Wastewater treatment facilities will increasingly claim their role as resources recovery plants instead of nutrient removal systems recovery not only in terms of water and nutrients but also of energy. The presented experiences from Central Europe point towards large energy saving potentials of typically 3-5%, which are just gradually being exploitet nowadays. What is feasible to reach in large-scale municipal WWTPs is underlined by the case study Strass, which already reached a positive energy balance without any relevant co-substrates. REFERENCES BUWAL Swiss Federal Ministry for Environment, Forest & Landscape (1994): Energy in WWT (in German). ISBN 3-95232-49-9. Bern, Switzerland. Greenfield, P.F., Batstone, D.J. (25). Anaerobic digestion: Impact of future greenhouse gases mitigation policies on methane generation and usage. Water Science & Technology, 52/1-2, 39-47. Insam H.; Wett, B. Control of GHG emission at microbial community level. Waste Management, in press. Keller, J., Hartley, K. (23). Greenhouse gas production in wastewater treatment: Process selection is the major factor. Water Science & Technology, 47/12, 43-48 LFUW Austrian Federal Ministry for Environment (21): Benchmarking in water management acquisition and comparison of technological and economical key figures (in German). Final Report. Vienna, Austria. Lindtner S., Ertl T. (26): OEWAV-Wastewater-Benchmarking Field Report 25 (in German). Österr. Wasser- und Abfallwirtschaft, 58/5-6, a16-a18. Müller E.A., Kobel B. (24): Energy-analysis at utilities in Nordrhein-Westfalen representing 3 millions PE energy-benchmarking and saving potentials (in German). Korrespondenz Abwasser, 51/6, 625-631. Müller E.A., Schmid F., Kobel B. (26): Activity Energy in WWTPs 1 years of experience in Switzerland (in German). Korrespondenz Abwasser, 53/8, 793-797. MURL Ministry for Environment, Nature Protection, Agriculture & Consumer Protection in the German State of North Rhine Westphalia (1999): Energy in WWTPs (in German). Düsseldorf, Germany. Shizas, I.; Bagley, D.M. (24): Experimental Determination of Energy Content of Unknown Organics in Municipal Wastewater Streams. J. Energy Engineering, 13/2, 45-53 Wett, B. (26). Solved upscaling problems for implementing deammonification of rejection water. Water Science & Technology, 53/12, 121-128 Wett, B. and Dengg, J. (26): Process- and operation optimization exemplified by case study WWTP Strass (in German). Wiener Mitteilungen, 195, 253-288 % 125 1 75 5 25