ASSESSMENT T-STRIPE. Rautenweg Wien

Similar documents
Observation of Liquid-filled Window without Presence of Liquid in Test Chamber

Certified Passive House Components: Spacers in Low-e Glazing Version 0.32, kk

Validation of a zonal model to capture the detailed indoor thermal environment of a room heated by a stove

Window Standards Compared:

Chapter 6. Space heating load

Assessing the energy performance of modern glass facade systems

INFOTEXT. OKALUX Light Diffusing Insulating Glass. Physical properties

OKALUX GmbH Marktheidenfeld Germany Tel.: +49 (0) Fax: +49 (0)

Report for the U-value of a Door System in Accordance with BS EN ISO :2006. Product description:

Curtainwalls. Brussels Window. Objectives. Windows & Curtainwalls. Curtainwalls. 1 R2 R3. High tech? Low tech?

ADVANCED FAÇADES AND HVAC SYSTEMS: PRELIMINARY RESULTS OF FULL-SCALE MONITORING

Brussels Window. Good Windows. Windows. Objectives. Why Good Windows? Windows. Need to control. Learn. Functions: Same as wall - plus.

Warm Edge Glazing Systems. High-Performance Insulated Glass Packages

Selecting Energy Efficient New Windows in Tennessee

Selecting Energy Efficient New Windows in Nevada

Selecting Energy Efficient New Windows in Illinois

Selecting Energy Efficient Replacement Windows in Arizona

Impact of Insulated Concrete Curb on Concrete Balcony Slab

European Timber Windows & Doors

Q-Air detailed physical properties

Residential Energy Code Update

Characterization and performance evaluation of solar shading devices

SMART SOLUTIONS DOUBLE GLAZING SOLAR COMFORT TINTING GLASS ASK OUR SALES REPRESENTATIVES ABOUT. Reduce your 23% energy costs * by as much as

A well-planned building envelope is a requirement for achieving high user comfort and low energy costs.

Selecting Energy Efficient Replacement Windows in Florida

The more intelligent way to insulate Thermix TX.N Warm edge spacers for insulating glass

Available online at ScienceDirect. Procedia Engineering 146 (2016 ) 60 68

STEADY STATE AND DYNAMIC THERMOPHYSICAL PARAMETERS OF TRANSPARENT BUILDING COMPONENTS

Energy Saving Benefits of Daylighting Combined with Horizontal Exterior Overhangs in Hot-and-Humid Regions

Sound insulation Capillary slabs decouple the panes of the insulating glazing and provide improved sound insulation.

3-Dimensional Thermal Analysis of Lenmak EnvaTherm and SpandrelTherm Backpan Assemblies

BC Energy Efficiency Act - Regulatory Proposal for Window and Door Products

REAL-TIME CONTROL OF OCCUPANTS THERMAL COMFORT IN BUILDINGS. Galway, Ireland

CONTENTS. Abbreviations: LT: Daylight Transmittance LR ext: Reflectance Outdoor SF: Solar Factor

JOTUN Cool Shades. Impact of the TSR Value on the Users Comfort and the Energy Performance of Buildings. ai³ Werner Jager

PHPP Report. Beattie Passive Inchkeith Drive

U-Factor, Solar Heat Gain Coefficient, Visible Transmittance and Condensation Resistance Calculation Report

Performance Standards of Glass Products Manufactured by Pilkington IGP

GLASS SELECTION GUIDE

FEDERATION TOWER MOSCOW DIFFERENT ROOM CLIMATES UNDER ONE ROOF

Thermal Bridge Analysis

Thermal Performance of Northern Facades ISO Clip System Summary

TREES Training for Renovated Energy Efficient Social housing. Section 1 Techniques 1.2 Replacement of glazing

The more intelligent way to insulate: Thermix TX.N plus Warm edge spacers for insulating glass

Simulation Performance, Solar Heat Gain Coefficient, Visible Transmittance and Condensation Resistance Calculation Report

Effect of energy renovation on thermal sensation and comfort

CEN/TC 89 - Thermal performance of buildings and building components

o C Think of why air and water is heated at home? To what temperatures do You need to heat? What about humidity? Which air velocities are accepted?

Lecture 3: Utilization of Passive Solar Technology

Windows for new and existing housing

Fit Thermawood Retro-fit Double Glazing for a warmer, healthier, drier home. Reduce energy costs, add value.

SGG PLANITHERM TOTAL New generation advanced performance low-e glass

U-Factor, Solar Heat Gain Coefficient, Visible Transmittance and Condensation Resistance Calculation Report

Evidence of Performance Calculation of thermal transmittance

High Performance Roof Daylighting

SOUTH AFRICAN NATIONAL STANDARD

Analysis of different shading strategies on energy demand and operating cost of office building

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

Passive House Northwest

THE INFLUENCE OF ENVELOPING ON ENERGETIC AND ECOLOGICAL EFFICIENCY OF PASSIVE HOUSES

WEEDOO - SA CONSTRUCTION TECHNOLOGY

Built-up metal walls. Built-up metal wall design. 3.3 Built-up Metal Walls

Insulated double and triple glass units, custom-built to specification and manufactured to the highest standards. Insulated glass units

ADAPTIVE LOW-E DOUBLE GLAZING WINDOW

April Section 3.3. Built-up Metal Walls

SUMMER THERMAL COMFORT IN TYPICAL FRENCH RESIDENTIAL BUILDINGS: IMPACT ASSESSMENT OF BUILDING ENVELOPE INSULATION ENHANCEMENT

Evaluation methods for indoor environmental quality assessment according to EN15251

Product information Vertical window element VIU

Creating Synergies 1. Increase temperature of surfaces 2. Reflect heat 3. Regulate moisture

LightBridge High performance residential double glazing for superb comfort and natural light in your home

Elegance Pro High quality windows & doors

Energy Performance of Windows: Navigating North American and European Window Standards

Aalborg Universitet Investigation of Different Configurations of a Ventilated Window to Optimize Both Energy Efficiency and Thermal Comfort

Product information Vertical window element VFE

CHAM Case Study Heat Transfer. within a Solar Panel

The Importance of Slab Edge & Balcony Thermal Bridges

Cost-Benefit Analysis of Dwelling Retrofit Options

FRAME AND SPACER MATERIALS

SIGMA GLASS PACK The Sigma glass pack combines a warm-edge Super G glass spacer system with two panes of glass to achieve an R-value of 1.89.

Repairing Windows and Doors. Mon

Improving Energy Efficiency in Buildings (IEEB) Energy Quarter, Ritaharju Monitoring

New window system: PRO TEC 7. Exceptional insulation More design solutions Passive house option

National Fenestration Rating Council. Incorporated NFRC [E1A6]

Glazing with Integral Sun Control Louvres

CAE 331/513 Building Science Fall 2017

This document is a preview generated by EVS

ENERGY EFFICIENT GLASS LESS ENERGY, MORE SAVINGS, BETTER FUTURE

Passive House in Canada and around the world

Architectural Testing, Inc. 849 Western Avenue North Saint Paul, Minnesota Dan Johnson, Director - Regional Operations

Thermal optimization of curtain wall façade by application of aerogel technology

SunSpots. Tests to determine accelerated aging effects on. A Closer Look at Airbag System Testing Techniques. In This Issue.

Technology & Style In Perfect Harmony

slimlite Double Glazed Units BS EN 1279 Certificate Double Glazed Units

Product information Additional window element GIL

TRR U-value calculator

Insulation - History. Heat Flow, in 2 and 3 D. Insulation - History. Insulation - History

Constructions Database User Guide IES Virtual Environment 6.3

Attaining Thermal Comfort in. Buildings with Predominantly. Glazed Facades. presented to: ANSYS Boston Regional Conference

Product information Additional window element GIU

Interpretation Variables and Common Areas of Confusion. Of the 2009 IECC

Transcription:

ASSESSMENT T-STRIPE for T-STRIPE Ltd. Rautenweg 8 1220 Wien www.t-stripe.com IBO - Austrian Institute for Healthy and Ecological Living Alserbachstraße 5/8 1090 Vienna www.ibo.at Authors DI (FH) Felix Heisinger DI Thomas Zelger Shortened version of the final document dated 15. September 2010 1

1. Goal Goal of this assessment is to study the principles behind the T-STRIPE window heating system, its structural-physical effects as well as energy consumption and influence on room climate. 2. Constraints To ensure realistic simulations the variants are being limited to 2 different window types. These types correlate to T-STRIPE's current main field of application. 1. Ceiling-high window (i.e. patio door) without radiator nearby 2. Skylight (at 45 ) without radiator nearby The criteria for the windows were as follows: U Glass = 1,1 W/m²K - double-glazed windows U Frame = 1,6 W/m²K - plastic frame Psi Bezel = ~0,06 W/mK, spacer: Aluminium Filling: Inert gas filling All calculations use heat transfer coefficients of glass pane and window frame according to ÖNORM EN ISO 10211, ÖNORM EN ISO 10077 or ÖNORM B 8110-2: Alpha inside= 7,7 W/mK equalling Rsi= 0,13 mk/w Alpha outside= 25 W/mK equalling Rse= 0,04 mk/w Measurements regarding the skylight are the same for all simulations in order to accommodate differences in vertical and angular installation. 2

Preface: All results are based on the assumption that a hygienic airflow is being maintained at all times. Possibilities of air flow and airings dropping under the hygienically necessary limit are not being considered. Solar irradiation is not being factored into the calculations. This results in calculations that are neutral to specific window orientations and coinciding energy costs or radiation factors. Convective energy passing is subject to a multitude of conditions and never a uniform constant, especially not when T-STRIPE is being applied. For this assessment the information provided in ÖNORM B 8110-2 - for instance the heat transfer coefficient - are being used. Due to these simplifications the simulations illustrate a 'worst-case' scenario'. 3. Calculations regarding the heat bridge effect To illustrate the very principles behind T-STRIPE we calculated the heat bridge effect in the 'ANTHERM' software. Surface temperatures and modifications caused by T-STRIPE were of prime interest. The results for these calculations are valid for both window types, since in both cases the calculations only illustrate a certain point in time accompanied by a distinct outdoor temperature. 3.1. Assumptions Temperatures: Calculations regarding the heat bridge effect assume an indoor temperature of 20 C and an outdoor temperature of -12 C (standard design temperature for construction parts without storage mass in Vienna) and -1,6 C (average temperature of construction parts during January). In regards to condensate, results of simulations with very low temperatures are considered more important. Materials: Designation Application Heat transmission W/mK Glass Glass panes 1 Gas fillung Gas filling between panes 0.0178 Sealant Sealant beneath spacer 0.4 PVC frame Window frame PVC 0.1 Zeolite Core material - spacer 0.13 Aluminium Cladding material - spacer 200 3

3.2. Results of the simulation at -12 C outdoor temperature Without T-STRIPE the lowest measured temperatures on the inside surface of the window pane were seven (7 ) degrees along the edges of the pane. With T-STRIPE the lowest recorded temperature on the glass surface was sixteen (16 ) degrees in the middle of the window pane. During these tests the T-STRIPE heating element itself reached a temperature of 38.9 degrees. 3.3. Results of the simulation at -1,6 C outdoor temperature Without T-STRIPE the lowest measured temperatures on the inside surface of the window pane were twelve (12 ) degrees along the edges of the pane. With T-STRIPE the lowest recorded temperature on the glass surface was seventeen and a half (17.5 ) degrees in the middle of the window pane. During these tests the T-STRIPE heating element itself reached a temperature of 42.7 degrees. 4

3.4. Main findings The simulations clearly show the difference in surface temperature of the window pane along the window frame. By using the T-STRIPE heating system the temperature factor f RSI can be raised significantly. Limit for Condensation Limit for Mold Value Without T-STRIPE 0.59 >=0.69 >=0.71 With T-Stripe 0.88 >=0.69 >=0.71 By using T-STRIPE both limits for mold and condensation are being surpassed, effectively preventing any condensation or mold from occuring! Due to the significant raise in surface temperature along the window frame the increase in warm air flow contributes to an overall increase in surface temperature of the window pane. The simulations have also shown how much of the thermal energy spent contributes to room climate and temperature: 63.2% of thermal energy will be reflected back into the room, while 37.6% dissipate outdoors. T-STRIPE therefore contributes to the heating of the room since window panes reflect parts of the thermal energy. 5

4. Comparison between different methods of condensate prevention In order to reduce the risk of condensation along the edges of the window frame the following methods are considered viable: Reduction of relative humidity by increasing airflow o Excess humidity can be released o Condensate cannot be ruled out o Energy consumption dependent on type of heating o Up to a certain temperature possible increase in comfort o Increase in air quality indoors Increase of indoor air temperature o Manipulation of the dew point o Condensate cannot be ruled out o Energy consumption dependent on type of heating o Up to a certain temperature possible increase in comfort Installation of T-STRIPE o Condensate can be prevented upon correct calibration o Electric power consumption o Increase in comfort since the surface temperature of the window pane is being raised 6