X-HVB shear connectors

Similar documents
General information Material specifications Carbon steel shank: HRC 58 Zinc coating: 8 16 µm Recommended fastening tools Single nail:

DECLARATION OF PERFORMANCE according to Annex III of the Regulation (EU) Nr. 305/2011 (Construction Products Regulation)

X-U General Purpose Nails for Concrete and Steel

Hilti X-HVB system. Hilti X-HVB system Solutions for shear connections

X-EM6H, X-EW6H, X-EF7H, X-EM8H, X-EM10H, X-EW10H Threaded Studs for Steel

Figure 1 shows a typical composite beam for reference. The beam shown is a rolled beam section from the built-in section database.

Advanced Eurocode Training. EN : Composite Structures

Eurocode Training EN : Composite Structures

X-FCM Grating Fastening System

COMPOSITE STRUCTURES PREPARED BY : SHAMILAH

DIVISION: METALS SECTION: METAL FASTENINGS SECTION: STEEL DECKING REPORT HOLDER: HILTI, INC.

The following excerpt are pages from the North American Product Technical Guide, Volume 1: Direct Fastening, Edition 15.

Design Guidance for TAB-Deck Composite Slabs using SMD Metal Decking reinforced with ArcelorMittal Steel Fibres

UNIVERSITY OF BOLTON WESTERN INTERNATIONAL CENTRE FZE. BEng (HONS) CIVIL ENGINEERING SEMESTER ONE EXAMINATION 2015/2016

Multideck 146. Contents

Technical Manual. The difference is.

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICES EVALUATION CRITERIA FOR

Structural Products. Multideck 50-V3 Galvanised Steel Floor Decking System

The Steel Construction Institute

Talk to us, THE SMART DECKING PEOPLE Visit or Global Roofing Solutions Bond-Dek Composite Deck

Structural Steel Products UK & Ireland. Multideck Technical Handbook

COMPOSITE STEEL-CONCRETE FLOORS

FROM: SUBJECT: HILTI X-ENP-19, X-HSN 24 or X-U POWDER-ACTUATED FASTENER SUBSTITUTION REQUEST

LEWIS Dovetailed sheeting. Dovetailed Sheeting

Agricultural Hall and Annex East Lansing, MI. Structural Design. Gravity Loads. 1- Based on US Standards

English translation prepared by DIBt Original version in German language

ST7008 PRESTRESSED CONCRETE

Contents. Tables. Notation xii Latin upper case letters Latin lower case letters Greek upper case letters Greek lower case letters. Foreword.

HST3 Metal expansion anchor

Basic Concepts. Introduction to Composite Design

The following excerpt are pages from the North American Product Technical Guide, Volume 1: Direct Fastening, Edition 15.

MasterSeries Composite SlimFloor Beam Design Sample Output

ComFlor decking system

The New SDI Diaphragm Design Manual

ANALYSIS AND DESIGN OF MULTI-STOREY COMPOSITE BUILDING

Metal Decking Specialists

LEWIS Dovetailed sheeting. Dovetailed Sheeting

The difference is Guidance for the preparation of Deck Manufacturing Schedules

Composite Steel Deck - Slabs

3.4.2 DESIGN CONSIDERATIONS

ASSIGNMENT 1 ANALYSIS OF PRESTRESS AND BENDING STRESS BFS 40303

Location Where Effective Slab Width is Checked

DIVISION: METALS SECTION: METAL FASTENINGS DIVISION: STEEL DECKING REPORT HOLDER: HILTI, INC. EVALUATION SUBJECT:

FROM: PROPOSED SUBSTITUTION: Use HILTI X-U instead of fillet weld or arc spot puddle weld

ComFlor manual Composite floor decking design and technical information

Bjorhovde, R. Stub Girder Floor Systems Structural Engineering Handbook Ed. Chen Wai-Fah Boca Raton: CRC Press LLC, 1999

CHAPTER 3 BEHAVIOUR OF FERROCEMENT HOLLOW SLABS

Flexure and Serviceability Limit State

Copyrighted material. Licensed to on 22/05/2014

Report No Originally Issued: 05/2013 Revised: 07/17/2014 Valid Through: 05/2015

2016 DESIGN AND DRAWING OF REINFORCED CONCRETE STRUCTURES

Introduction 17/05/2015. How prestressing force transmitted to concrete?

Level 6 Graduate Diploma in Engineering Structural analysis

Manual Composite Beam Design

REPORT HOLDER: BLUE POINT FASTENING, INC YORBA COURT CHINO, CALIFORNIA EVALUATION SUBJECT:

R-Group Finland Oy. RTA, RWTL and RWTS Lifting anchors Design instructions

HKD Push-in anchor, Single anchor application

Composite Beam Design Manual AISC

PC Beam Shoe. Corbel system to support beams. Technical Manual. Version: DK 4/2012 Design standard: DS EN Eurocodes + NA (Denmark)

FORMDECK. constructions. constructions

Metal Decking Specialists

SINGLE ANCHOR USE FOR NON-CRACKED CONCRETE

ESR-2269 Reissued November 1, 2008 This report is subject to re-examination in one year.

HUS3-H 8 / 10 / 14 Carbon steel concrete screw with hexagonal head. HUS3-C 8 / 10 Carbon steel concrete screw with countersunk head

UNIVERSITY OF BOLTON WESTERN INTERNATIONAL COLLEGE FZE. BEng (HONS) CIVIL ENGINEERING SEMESTER ONE EXAMINATION 2018/2019

HRD Frame anchor, Redundant fastening

CLT Structural Design Sylvain Gagnon, Eng. February 8, 2011 Vancouver

eight plates and grids APPLIED ACHITECTURAL STRUCTURES: DR. ANNE NICHOLS SPRING 2018 lecture STRUCTURAL ANALYSIS AND SYSTEMS ARCH 631

Comparative Study on Effect of Powder Actuated Nail and Stud Welding on Steel Member

xiii Preface to the Fifth Edition Preface to the Second Edition Factors for Conversion to SI Units of

HKD Push-in anchor, Single anchor application

Hilti North America Installation Technical Manual Technical Data MI System Version

HRD-U 10 / - S 10 / -U 14 Frame anchor

midas Gen MIDAS On-Demand Service midas Gen Advanced Webinar Steel Structure Design

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT:

Manual Composite Beam Design

R-Group Finland Oy. REA Lifting Inserts Technical Manual According to Eurocodes, EU Machinery directive 2006/42/EC and VDI/BV-BS 6205 CE Approved

eight plates and grids Plates, Slabs & Grids Plates, Slabs & Grids Term Project plates horizontal plane, rigid slabs thin, flat, rigid

Originally Issued: 05/20/2013 Revised: 07/07/2017 Valid Through: 05/31/ Design

Schöck Isokorb type KS

Application nr. 6 (Connections) Strength of welded connections to EN (Eurocode 3, Part 1.8)

HOLLOW CORE FLOORS SPEED AND STRENGTH

PROFILED SHEETING NP EN COLD FORMED SECTIONS STANDARD

Trusted SECTION: 04 HILTI, INC. TULSA, Conformity! ICC-ES Evaluation. not specifically. Copyright 2015

TECHNICAL MANUAL. PETRA Slab Hanger. Hollow-Core Support for Slab Openings

Features and Benefits

DESIGN OF RC BEAMS AND FLOORS, BRACING

HKD Push-in anchor, Single anchor application

Steel Design Guide Series. Steel and Composite Beams with. Web Openings

SMD. Structural Floor and Roof Solutions. Product Selector Steel Floor & Roof Decking

Anchor HSA Fastening. Technology Manual HSA. Stud anchor. Version /

Composite Beam Design Manual. AISC-ASD89 Specification

Modeling stiffener distortion in orthotropic bridge decks with FEM using superelements

EN DK NA:2007

STRUT METAL FRAMING SYSTEMS


HOLORIB /SUPERHOLORIB

Diploma in Civil Engineering. Term-End Examination June, BCE-041 : THEORY OF STRUCTURES II

Route 360 Inverted T-beams. Carin Roberts-Wollmann Virginia Tech Tommy Cousins Clemson University Fatmir Menkulasi Louisiana Tech

HLC. Hex head nut with pressed-on washer HLC-H. Bolt version with washer HLC-L. Torx round head HLC-SK. Torx Counter sunk head HLC-EC

Transcription:

X-HVB shear connectors Product data Dimensions X-HVB 140 X-HVB 15.5 51 63 14.5 0.6 31.5 51 63 X-HVB 110 X-HVB 95 51 63 11.5 X-HVB 80 50 60 80 X-HVB 40 0.6 31 4.3 43 50 60 17.5 95 X-HVB 50 50 88 5 0.6 31 4.3 4.3 X-ENP-1 HVB Ø7.4 General information Material specifications X-HVB arbon steel: R m = 95 350 N/mm Zinc coating: 3 μm X-ENP-1 HVB arbon steel shank: HR58 Zinc coating: 8 16 μm Recommended fastening tools Tool DX 76 DX 76 PTR Fastener guide X-76-F-HVB X-76-F-HVB-PTR Piston X-76-P-HVB X-76-P-HVB-PTR artridges 6.8/18M black, red (for details see application limit X-ENP-1 HVB) See Tools and equipment for more details. Approvals and design guidelines SOOTE (France) DIBt (Germany) MLIT / BJ (Japan), Rom. Ministry AT 016-01/14-010 (Roma), TZÚS (zech) Note: technical data presented in these approvals and design guidelines reflect specific local conditions and may differ from those published in this handbook. If the fastening is subject to an approval process or where a design guideline must be used, technical data in the approval or design guideline has precedence over data presented here. Approval copies are available from your Hilti technical advisory service. 50 99 4.3 Ø4.5 5.8 Ø15 06 / 015 111

Applications Examples Typical application of X-HVB shear connector with steel deck, e.g. new construction. Typical application of X-HVB shear connector with jack arch system (without steel deck), e.g. rehabilitation project. Design data Designation LW 1) / NW ) haracteristic shear resistance, P 3) Rk Design shear resistance, P Rd 4) X-HVB 40 LW 5 kn 0 kn N.A. X-HVB 50 LW 5 kn 0 kn N.A. X-HVB 40 NW 8 kn 3 kn N.A. X-HVB 50 NW 8 kn 3 kn N.A. X-HVB 80 NW 8 kn 3 kn 14 kn X-HVB 95 NW 35 kn 8 kn 17.5 kn X-HVB 110 NW 35 kn 8 kn 17.5 kn X-HVB 15 NW 35 kn 8 kn 17.5 kn X-HVB 140 NW 35 kn 8 kn 17.5 kn 1) LW: lightweight concrete with density of 1800kg/m3 and class L0- ) NW: normal weight concrete with density of 400kg/m3 and class 0-5 3) As defined in EN1994-1-1 (nominal strength in AIS-LRFD) 4) As defined in EN 1994-1-1 5) Allowable shear in AIS-ASD Allowable horizontal shear 5) 11 06 / 015

Reduction factors for profile metal decks 1 x 1,5 Ribs transverse to beams Note: k t 1.0 k t = K N r h sc EN 1994-1-1 designs: K = 0.70 N r = X-HVBs / rib ( in the calculation even if 3 are placed in a rib) AIS, IS, BS 5950, other design codes: K = 0.85 N r = X-HVBs / rib (1, or 3) Ribs parallel to beams for 1.8 k p = 1.0 for < 1.8 k p = 0.6 x h sc Note: k p 1.0 06 / 015 113

Engineering advice onnector placement along the beam The X-HVB is a flexible connector and may be uniformly distributed between critical sections. These critical sections, where large changes in shear flow occur, may be at supporting points, points of application of point loads or areas with extreme bending moments. Partial shear connection Strength: The minimum connection depends on the design code used: a) In EN 1994-1-1 design, N/N f must be at least 0.4. This increases depending on span length and decking geometry. b) In AIS, N/N f must be at least 0.5. c) In IS, N/N f must be at least 0.50. Deflection control only: If the shear connection is needed for deflection control only, there is no minimum degree of connection. However, minimum allowable connector spacing applies and the steel beam must have enough strength to carry the self-weight and all imposed loads. 114 06 / 015

Application requirements Thickness of base material Thickness of fastened material 8 Minimum thickness of steel base material t II = 8 mm In rehabilitation projects, application to thin beam flanges of minimum 6 mm is possible in order to take the use of small I-sections (e.g. IAO 100 or IPN 80) into account. Please refer to Socotec approval or contact Hilti for detailed information. 1 x 1.5 Maximum thickness of decking t I = 1.5 mm onnector positioning, spacing and edge distances General positioning or or Position the X-HVBs so that the shear force is transferred symmetrically to the beam. X-HVB orientation parallel to the axis of the beam is preferred. Positioning on metal decks - ribs transverse to beam 1) One, two or three X-HVBs per rib Parallel to beam Perpendicular to beam 06 / 015 115

a) Position in the rib : 1 X-HVB per rib leg centred in the rib or 40 mm clearance = = 40 mm b) With or 3 X-HVBs per rib legs centred in the rib or alternated about the center = = 3) Spacing along the ribs basic minimum spacing, a 50 mm a 100 mm for: b o /m < 0.7 and b o / < 1.8 SDI 3 composite decking (USA) 50 mm a m = rib spacing Positioning on solid slabs and metal decks ribs parallel to beam 4 hc 600 mm 100 mm 4 hc 600 mm 100 mm 50 mm hc hc With 1 connector per row, alternate direction of connectors from X-HVB to X-HVB. In case of multiple rows (parallel to the beam axis), X-HVBs must be placed with the same direction inside of each row and alternate from row to row. 116 06 / 015

learance to metal decking b o 60 mm Split decking if necessary for spacing / clearance orrosion information The intended use only comprises fastenings which are not directly exposed to external weather conditions or moist atmospheres. Application limits Application limits are valid only if correct cartridge and power setting are used! Application limits X-ENP-1 HVB Steel thickness, tii [mm] >0 10 18 17 16 15 14 13 1 11 10 Applicable range of base materials 9 S 35 8 S 75 7 S 355 6 350 400 450 500 550 600 650 700 750 Steel strength, R m [N/mm ] Thermo-mechanically rolled construction steel In thermo-mechanically rolled construction steel, e.g. S 355M per EN 1005-4 the application limit is reduced by 50 N/mm artridge preselection and power setting Steel thickness tii [mm] >0 10 18 17 16 15 14 13 1 11 10 9 8 Black 4 from 10 mm Red 4 Black 4 from 10 mm Black 3 Black S 35 S 355 Fine adjustment by carrying out installation tests on site 06 / 015 117

Fastener selection h c h sc onnector 8 mm Maximum decking height [mm] Designation Item no. / 1.8 / < 1.8 X-HVB 40 1156 Not for use with profiled decking X-HVB 50 56467 Not for use with profiled decking X-HVB 80 39357 45 45 X-HVB 95 348179 60 57 X-HVB 110 348180 75 66 X-HVB 15 348181 80 75 X-HVB 140 34831 80 80 All connectors with two nails X-ENP-1 HVB 8351 1 x 1,5 Fastening quality assurance Fastening inspection h NVS X-HVB Metal decking Structural steel X-ENP-1 HVB h NVS = 8. 9.8 mm 118 06 / 015