Boulder City NV Prepared by (Print Name) Signature Date

Similar documents
2015 MICHIGAN UNIFORM ENERGY CODE Effective: February 8, 2016

Hardin County Planning and Development Commission

Town of Farragut RESIDENTIAL CONSTRUCTION ENERGY EFFICIENCY. LAST UPDATE: July 03, 2014

A Closer Look Inspection Service 2015 IECC Residential DFW area handout

General Contractor: Company Name: Location of Proposed Structure: Tax Map #: Lot #:

Charter Township of Washington

Town/City: State: Zip: Town/City: State: Zip: Phone: Cell: Phone: Cell:

2015 Michigan Residential Code Energy Worksheet for New Single-family Residential Building

2015 Michigan Residential Code Energy Worksheet for New Single-family Residential Building

Feature Zone IECC 2009 IECC

Table Air Barrier and Insulation Inspection Component Criteria

Presented by: Stephen Carr Regional Building Science Manager (386)

Performance Requirements and Options in the International Energy Conservation Code. Mike Turns, Senior Program Manager

Project Type: New Home Addition Alteration (Describe)

Town/City: State: Zip: Town/City: State: Zip: Phone: Cell: Phone: Cell:

2015 Michigan Residential Code Energy Worksheet for Single-family Additions, Alterations, Renovations and Repairs

Fenestration Components: Mechanical Summary. Water heater energy factor: Ef Fuel type: Gas Electric Other

Prescriptive Checklist for the 2015 Washington State Energy Code

FIELD COPY ATTACHMENT

Presented by: Stephen Carr Regional Building Science Manager (386)

2012 IECC Residential with State Adopted Changes

Michigan Energy Code Training and Implementation Program

REScheck Software Version Compliance Certificate

IRC 2012 Key Changes

Residential Data Collection Checklist 2009 International Energy Conservation Code Climate Zone 2

Air Sealing for 5 ACH 50

RESIDENTIAL ENERGY EFFICIENCY

PICK YOUR POISON AND HOW TO GET THERE. Presented By Robby Schwarz

SUSTAINABLE ENERGY ANALYTICS

2009 IECC with St Louis Amendments. Fenestration U-factor Skylight U-factor Glazed fenestration SHGC NR 0.

Standards for Jackson EMC s Right Choice Program Revised: June 2011

Residential Requirements of the Texas Energy Code 2009 IRC Chap 11

Insulation, Fireblocking, Draftstopping and Crawl Space Requirements REVISION DATE: JANUARY 2017

RESIDENTIAL ENERGY EFFICIENCY

2015 IECC Air Sealing Multifamily For Code Compliance Funding for Energy Code Training

Date Rater Verified. Rater Verified. Slab / Pre-Drywall / Thermal Inspection

Compliance Certificate

1. PREINSPECTION RESIDENTIAL ENERGY EFFICIENCY 7

Instructions for the Residential Building Data Collection Checklist 2009 International Energy Conservation Code with 2011 Georgia Amendments

IECC Residential Significant Changes Summary. Tier I

Compliance Certificate

Appendix RA Air Sealing and Insulation Key Points COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA

Project Name: Enforcement Agency: Permit Number:

Compliance Certificate

APPROVED. Acceptable to the code official for compliance with the provisions of the applicable Code or referenced Standard.

Montana Homebuilder Brief: Residential Energy Code 1

THE CITY OF FAYETTEVILLE ADOPTED THE 2009 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) ON JULY 17, 2012

Residential Buildings Energy Code Summary

Single Family Residence Building Permits

MECHANICAL INSPECTION DIVISION CITY OF NEW ORLEANS

RESIDENTIAL ENERGY EFFICIENCY

Air Sealing, Infiltration & Ventilation

A.ENVELOPE AIR SEALING

RESIDENTIAL ENERGY CODE. The 2015 International Energy Conservation Code (IECC) as modified below.

Energy Code Basics for Residential Buildings. Presented by Newport Ventures NEWPORT VENTURES

Development and Introduction to the 2012 North Carolina Energy Conservation Code

Plan Check & Field Inspection Guide

IECC Provisions for Multi-Family Buildings

The times are changing. Are you Ready?

REScheck Software Version Compliance Certificate

Michigan Energy Code Training and Implementation Program

1 Exam Prep Florida Building Code-Energy Conservation Edition Tabs and Highlights

Part IV Energy Conservation

2009 IECC Chapter 1 Additions, alterations, renovations or repairs.

1/17/2018. IECC Real World Applications. The look and layout of the 2015 IECC. The IECC covers both: Commercial (CE) chapters 1-6.

Major Texas Energy Code Changes (CZ3) TexEnergy Solutions August 30 th, 2016

Success with 2009 IECC in Georgia: Tech Tips for Builders. Insulation. Copyright 2014 Advanced Energy. All Rights Reserved

Quick Reference Guide for 2009 IECC Residential Energy Efficiency Climate Zone 2

ENERGY STAR Qualified Homes, Version 3 (Rev. 03) Inspection Checklists For National Program Requirements

THE GEORGIA ENERGY CODE: 2009 IECC + AMENDMENTS

INSULATION INSTALLATION

ORDINANCE NO. XXXX BE IT ORDAINED BY THE GOVERNING BODY OF THE CITY OF LAWRENCE, KANSAS:

Subject: Energy Subcode Compliance. Reference: N.J.A.C. 5: (f)1.vi, 2.18(b) and 3.18

Inspection of New One- and Two- Family Dwellings

SOUTHWEST ENERGY CODES CONFERENCE. This is how we do it! Getting to 3ACH50 and

Quick Reference Guide for 2009 IECC Residential Energy Efficiency Climate Zone 5 and Marine 4

Quick Reference Guide for 2009 IECC Residential Energy Efficiency Climate Zone 3

Quality Insulation Installation (QII) Insulation Installation (Page 1 of 4)

Quick Reference Guide for 2009 IECC Residential Energy Efficiency Climate Zone 6

Residential Codes FAQs: 2015 International Energy Conservation Code (IECC) with MA Amendments & MA Stretch Energy Code

A LOOK INTO THE 2015 IECC RESIDENTIAL PROVISIONS. Presented by: Shaunna Mozingo, Colorado Code Consulting

Effective Date: April 25, 2016 Revised: November 7, 2017

Overview of Presentation. Airflow Control: Why. Airflow Control: what kind?

Recommended Amendments to the 2012 International Residential Code (IRC)

2012 Washington Energy Code - Residential.

SAN MIGUEL COUNTY & TOWN OF MOUNTAIN VILLAGE BUILDING DEPARTMENTS PRESCRIPTIVE ENERGY CODE & GREEN BUILDING STANDARD

BUILDING ENERGY CODES UNIVERSITY

Pennsylvania Alternative Residential Energy Provisions

Vermont Residential Building Energy Code. Handbook. A Guide to Complying with Vermont s Residential Building Energy Standards (30 V.S.A.

New Hampshire Residential Energy Code

By James Tente, MCP, CBO,CFM

PREP + INSULATION. DISCLAIMER: These tools are for illustrative purposes only and

Article 14 - Indiana Residential Code, Chapter 11: Energy Efficiency

1. The 2018 NCECC shall regulate the design and construction of buildings for the effective use of.

1998 and 2000 International Energy Conservation Code Version 3.0 April 2000

Chapter 14 - Air Sealing

Initial House Assessments & Sealing Options:

Presentation Overview: NC Energy Code RESNET Standards HERS Index HERS Verification Process

Town of Derry New Residential Building Permit

Applying Energy Code to Existing Buildings

Transcription:

City of Boulder City Community Development Department Building & Safety Division 401 California Avenue Boulder City, NV 89005-2600 702-293-9282 (Main Line) 702-293-9392 (Fax) 2009 International Energy Conservation Code Prescriptive Compliance Requirements for Single-Family and Two-Family Dwellings, New Residences, Additions and Remodels This document does not include weighted averages for fenestration, unlabeled fenestrations, site-built fenestrations, mass walls, metal framing or crawl spaces. See IECC for additional information. Address Boulder City NV 89005 Permit Number Prepared by (Print Name) Signature Date Energy Code Requirements by Component The building thermal envelope, air barrier, fenestrations and systems shall meet the following: Component Your Residence (Check one box from each of the items below. If there is only one item in the box, it is a mandatory item with no other option.) Doors Each door has a maximum 0.50 U-Factor Fenestrations Windows Each window has a maximum 0.50 U-Factor and a maximum 0.30 Solar Heat Gain Coefficient Skylight Air Infiltration Unlabeled Fenestration Products Each skylight has a maximum 0.65 U-Factor and a maximum 0.30 Solar Heat Gain Coefficient No skylights are used Windows, skylights and sliding glass doors shall have a listing demonstrating an air infiltration rate of no more than 0.3 cfm per square foot, and swinging doors no more than 0.5 cfm per square foot All doors, windows and skylights will be labeled Site-Built Fenestration Products No site-built fenestration products are used Insulation Ceiling Minimum R-30 insulation tight to ceiling Minimum R-30 insulation tight to roof sheathing Wood Frame Wall Minimum R-13 insulation Floor (above garage and cantilevered) R-19 cavity insulation tight to underside of floor sheathing I do not have a floor assembly that is part of the building thermal envelope Page 1 of 6

R-5 minimum continuous insulating sheathing Basement Wall R-13 minimum cavity insulation on interior of wall Foundation Slab-on-Grade I do not have a basement The slab-on-grade is unheated The slab-on-grade is heated. I will provide R-5 perimeter insulation to the lesser of bottom of the footing or 24-inches deep I do not have a slab-on-grade I will hire a third party firm to provide air sealing testing Air Leakage Building Thermal Envelope Air Leakage Wood-Burning Fireplace I wish for the City of Boulder City to provide air sealing inspections. I will schedule these inspections at the appropriate time. (See Inspection Schedule for requirements) Provide gasketed doors, outdoor combustion air, and comply with IRC Chapter 10, including local amendments No wood-burning fireplace included Recessed Lighting Recessed lighting installed in the building thermal envelope shall be IC-rated and shall be sealed to the interior wall or ceiling covering I do not have recessed lighting in the thermal envelope HVAC Systems Heat Loss Calculations and Equipment Sizing Thermostat Duct Insulation Provide ACCA Manual S heating and cooling equipment sizing and ACCA Manual J heating and cooling calculations or other approved methodologies This is a remodel and/or addition without any new heating/cooling equipment installed Provide programmable thermostat for each system This is a remodel and/or addition without any new heating/cooling equipment installed Ducts shall be insulated supply ducts to a minimum of R-8 and all other ducts to a minimum of R-6 All ducts are located within the building thermal envelope, therefore, no duct insulation is required Duct Sealing Ducts, plenums, etc. shall be sealed Duct Testing The heating and cooling system on this project does not use any ductwork I will hire a third party firm to provide duct testing. The third party firm shall be a certified HERS rater or a firm listed on the Clark County Building Department Quality Assurance approved list of duct testing agencies This is a remodel and/or addition without any new heating/cooling equipment installed and I wish to utilize inspection exception Mechanical System Piping Insulated to a minimum of R-3 I have package units and no mechanical system piping Outside Air and Exhaust Provide automatic or gravity dampers on all outside air intake vents and exhaust terminations. Clothes dryer exhaust vents through the roof are exempt Page 2 of 6

Service Hot Water Electrical Lighting Sun Room Non-circulating System All service hot water piping installed in unconditioned spaces, including under-slab piping, shall be insulated to at least R-2 Circulating System All service hot water piping installed in unconditioned spaces, including under-slab piping, shall be insulated to at least R-2, and shall include an automatic or readily accessible manual switch that can turn off the hot water circulating pump when the system is not used This is a remodel and/or addition without any new hot water installed A minimum of 50 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps The sun room is not thermally isolated from the remainder of the building and will comply with all requirements The sun room is thermally isolated from the dwelling and shall comply as follows: R-19 minimum ceiling insulation R-13 minimum wall insulation 0.50 maximum U-Factor 0.75 maximum Skylight U-Factor I do not have a sun room Additional Requirements Standard Notes All materials, systems and equipment shall be installed in accordance with the manufacturer s installation instructions and the adopted codes. Submittal Requirements Prior to Final Inspection The contractor shall provide a certificate for energy conservation. The certificate shall: be permanently installed on a wall adjacent to the water heater be approved by the jurisdiction be completed by the builder or registered design professional have a heading stating DO NOT REMOVE in ½ minimum bold face letters list the predominant R-values of insulation installed in or on ceiling/roof, walls, foundations (slab, basement wall, crawlspace wall and/or floor) and ducts outside conditioned spaces list U-factors for fenestration list solar heat gain coefficient (SHGC) of fenestration list the types and efficiencies of heating, cooling and service water heating equipment list the value covering each area or component separately, where there is more than one value for each component The contractor shall provide maintenance instructions for equipment and systems that require preventative maintenance. Required regular maintenance actions shall be clearly stated and incorporated on a readily accessible label The title or publication number for the operation and maintenance manual for that particular model and type of product shall be included Provide report of test showing all duct assemblies located outside the conditioned space comply with Section 403.2.2. Provide building envelope air tightness test results showing compliance with Section 402.4.2.1 or visual inspection results showing compliance with Section 402.4.2.2 Page 3 of 6

Building Thermal Envelope and Insulation The building thermal envelope includes the basement walls, exterior walls, floor, roof, and any other building air barrier element(s) that enclose conditioned space. This boundary also includes the air barrier between conditioned space and any exempt or unconditioned space. The building thermal envelope shall comply with the minimum R-values in the table. R-values for walls represent the sum of cavity insulation plus insulated sheathing, if any. Do not count any other material. Mass walls shall be above grade walls of concrete bloc, concrete, insulated concrete form, masonry cavity, brick (other than veneer), earth (adobe, compressed earth block, rammed earth) and timber/logs. See IECC. A heated slab is slab-on-grade construction in which the heating elements, hydronic tubing, or hot air distribution system is in contact with, or placed within or under, the slab. Total UA average calculation is not included in this handout. See IECC. Access doors from conditioned spaces to unconditioned spaces (i.e., attics and crawl spaces) shall be weatherstripped and insulated to a level equivalent to the insulation on the surrounding surfaces. Provide a barrier to prevent loose fill insulation from spilling out of the attic when access is open. This is not required for batts and other fixed insulation. Catwalks and equipment platforms shall be constructed so as to not compress any insulation. Basement wall insulation must extend from the top of the wall down 10 feet below grade or to the basement floor, whichever is less. Insulation on exterior of building at or below grade shall be protected by rigid, opaque and weatherresistant covering to a minimum of six inches below grade. Insulation Marking, Certification and Labeling Requirements o Each piece of building thermal envelope insulation 12 inches or greater in width shall be installed such that the manufacturer s R-value identification mark is readily observable for inspection. For each element of the building thermal envelope, other than those that are more than 12 inches in width and the manufacturer s R-value mark is visible, the insulation installers shall provide a certificate listing the: Type Manufacturer, and R-value of insulation o Blow or sprayed roof/ceiling insulation (fiberglass or cellulose) shall be marked. Markers shall: Be fixed to the trusses or joists Be installed throughout the attic space Be installed at least one for every 300 square feet Face the attic access opening Indicate the minimum initial installed thickness Include the thickness written in inches Have numbers a minimum of 1 inch in height For blown or sprayed insulation (fiberglass and cellulose), the insulation installers shall provide a certification for: The initial installed thickness Settled thickness Settled R-value Installed density Coverage area, and Number of bags installed Fenestrations Fenestrations include skylights, roof windows, vertical windows (fixed or moveable), opaque doors, glazed doors, glazed block and combination opaque/glazed doors. Fenestration includes products with glass and non-glass glazing materials. All fenestration products shall be labeled from the manufacturer showing compliance. Window, door and skylight U-factors and SHGCs must be determined from a National Fenestration Rating Council (NFRC) rating that is independently certified and set forth on a label on the product. Solar Heat Gain Coefficient applies to each door, window, skylight or other fenestration product with 50 percent or more glazed area. Page 4 of 6

Air Leakage The building thermal envelope shall be durable sealed to limit infiltration. The sealing methods between dissimilar materials shall allow for differential expansion and contraction. The following areas shall be caulked, gasketed, weatherstripped or otherwise sealed with an air barrier material, suitable film or solid material: o All joints, seams and penetrations o Site-built windows, doors and skylights o Openings between window and door assemblies and their respective jambs and framing o Utility penetrations o Dropped ceilings or chases adjacent to the thermal envelope o Knee walls o Walls and ceilings separating a garage from conditioned spaces o Behind tubs and showers on exterior walls o Common walls between dwelling units o Attic access openings o Rim joist junction o Other sources of infiltration Sealing of these items shall be inspected or a door test shall be performed. o If the inspection option is used, inspections shall be completed by City of Boulder City Building Inspectors. The permit holder shall schedule energy inspections at the appropriate intervals during construction. See Energy Inspection Table for more information. o If the testing option is used, the testing shall be performed by a licensed HERS rating firm, hired by the permit holder. A report shall be submitted to the building inspector prior to any pre-final inspection. The firm shall be a certified HERS rating firm or shall be listed as an approved special inspection firm on the Clark County list. HVAC Systems Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on building loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculations methodologies. These calculations are typically performed by a contractor or an engineer. Exceptions include: o Same-for-same heating or cooling equipment change-outs. o Additions and remodels that utilize existing equipment and do not add any new equipment. Temperature Controls o At least one thermostat shall be provided for each separate heating and cooling system. o The thermostat shall be capable of controlling the heating and cooling system on a daily schedule to maintain different temperature set points at different times of the day. o This thermostat shall include the capability to set back or temporarily operate the system to maintain temperatures down to 55ºF or up to 85ºF. o The thermostat shall initially be programmed with a heating temperature set point no higher than 70ºF and a cooling temperature set point no lower than 78ºF. Ducts o Building framing cavities shall not be used as ducts. o All ducts, air handler connections at the plenum and filter boxes shall be sealed to comply with the Uniform Mechanical Code. o Duct tightness test. All duct assemblies including manufacturer s air handler enclosure must be tested for leakage. This test may be done during duct HVAC rough-in or when building is complete. The test shall comply with IECC Section 403.2.2. This test is not required if the entire duct assembly and air handler are located within the conditioned space. Permit holder shall hire firm to provide this test. The third party firm shall be a Certified HERS Rater, or Firm listed on Clark County Building Department Quality Assurance approved list of duct testing agencies. Duct Testing Exceptions are as follows: o New duct work is not installed. o o New heating and/or cooling units are not installed. Same-for-same heating or cooling equipment change-outs where ducts are not added and/or modified. Page 5 of 6

Electrical Power and Lighting Systems High-efficacy lamps include compact fluorescent lamps, T-8 or smaller diameter liner fluorescent lamps, or lamps with a minimum efficacy of: o 60 lumens per watt for lamps over 40 watts, o 50 lumens per watt for lamps over 15 watts to 40 watts, and o 40 lumens per watt for lamps 15 watts or less Air Barrier and Insulation Inspection Criteria and Codes All of the following components must be inspected and accepted by the City of Boulder City Building and Safety Division or the building must be tested in accordance with IECC Section 402.4.2.1 Air Leakage Door Fan Test Component Criteria Inspection to be Scheduled Exterior thermal envelope insulation for framed walls is installed in substantial contact and continuous alignment Air Barrier and Thermal with building envelope air barrier. Barrier Breaks or joints in the air barrier are filled or repaired. Air-permeable insulation is not used as a sealing material. Air-permeable insulation is inside of an air barrier. Air barrier in any dropped ceiling/soffit is substantially Ceiling/Attic aligned with insulation and any gaps are sealed. Attic access (except unvented attic), knee wall door or drop down stair is sealed. Walls Corners and headers are insulated. Junction of foundation and sill plate is sealed. Windows and Doors Space between window/door jambs and framing is sealed. Rim Joists Floors (including abovegarage and cantilevered floors) Crawl Space Walls Shafts, Penetrations Narrow Cavities Garage Separation Recessed Lighting Plumbing and Wiring Shower/Tub on Exterior Wall Electrical/Phone Box on Exterior Walls Rim joists are insulated and include an air barrier. Insulation is installed to maintain permanent contact with underside of subfloor decking. Air barrier is installed at any exposed edge of insulation. Insulation is permanently attached to walls. Exposed earth in unvented crawl spaces is covered with Class I vapor retarder with overlapping joints taped. Duct shafts, utility penetrations, knee walls and flue shafts opening to exterior or unconditioned space are sealed. Batts in narrow cavities are cut to fit or narrow cavities are filled by sprayed/blown insulation. Air sealing is provided between the garage and conditioned spaces. Recessed light fixtures are air tight, IC rated, and sealed to drywall. Exception-fixtures in conditioned space. Insulation is placed between outside and pipes. Batt insulation is cut to fit around wiring and plumbing, or sprayed/blown insulation extends behind piping and wiring. Showers and tubs on exterior walls have insulation and an air barrier separating them from the exterior wall. Air barrier extends behind boxes or air sealed-type boxes are installed. Common Wall Air barrier is installed in common all between dwelling units. HVAC Register Boots HVAC register boots that penetrate building envelope are sealed to subfloor or drywall. All Roughs Fireplace Fireplace walls include an air barrier. Page 6 of 6