Figure 1: Longitudinal section of the gothic church with baroque tower curia [1]

Similar documents
Structural safety and rehabilitation of connections in wide-span timber structures - two exemplary truss systems

STUDY ON THE FLEXURAL BEHAVIOUR OF CFRP-GRID REINFORCED CONCRETE ONE-WAY SLABS

STRUCTURAL INTERVENTIONS TO MONUMENTAL BUILDINGS

Analysis and experimental studies of building glass facade

Repair and Retrofit of a 17 th Century Library Structure in Istanbul

SHEAR BEHAVIOR OF RC DEEP BEAMS WITH SOLID CIRCULAR CROSS SECTION UNDER SIMPLY SUPPORTED CONDITION AND ANTI-SYMMETRIC MOMENT

DESIGN OF PRECAST STEEL FIBRE REINFORCED TUNNEL ELEMENTS

Chapter 7. Finite Elements Model and Results

Nonlinear Models of Reinforced and Post-tensioned Concrete Beams

Scientific Seminar Design of Steel and Timber Structures SPbU, May 21, 2015

Application of Tensioned CFRP Strip Method to an Existing Bridge

Behaviour of deviated CFRP-Strips

INSTALLATION. General. Important Note. Design. Transport

ANALYSIS OF CARBON-FIBER COMPOSITE STRENGTHENING TECHNIQUE FOR REINFORCED BEAM

RECONSTRUCTION, SEISMIC STRENGTHENING AND REPAIR OF THE ST. ATHANASIUS CHURCH I LESHOK CASE STUDY

STRUCTURAL INTERVENTIONS ON MONUMENTAL BUILDINGS

one structural behavior and design ARCHITECTURAL STRUCTURES: FORM, BEHAVIOR, AND DESIGN DR. ANNE NICHOLS FALL 2016 lecture

PRESTRESSED CONCRETE STRUCTURES. Amlan K. Sengupta, PhD PE Department of Civil Engineering Indian Institute of Technology Madras

Reinforcement of glulam beams with FRP reinforcement

Nonlinear Finite Element Analysis of Composite Cantilever Beam with External Prestressing

Glass fibre reinforced textile composites strengthening solutions for masonry arches

CHAPTER 5 FINITE ELEMENT ANALYSIS OF GFRP COMPOSITE BRIDGE DECK PANELS

CHAPTER 5 FINITE ELEMENT MODELLING

Strengthening of Reinforced Concrete Beams using Near-Surface Mounted FRP Mohamed Husain 1, Khaled Fawzy 2, and Mahmoud Nasr 3

INFLUENCES OF ADVANCED COMPOSITE MATERIALS ON STRUCTURAL CONCEPTS FOR BRIDGES AND BUILDINGS. Introduction. Bridges

Finite Element Analysis of RC Beams Strengthened with FRP Sheets under Bending

Contents. 1.1 Introduction 1

QUASI-STATIC TESTS ON WALL ELEMENTS CONSTRUCTED DURING THE RECONSTRUCTION OF ST. ATHANASIUS CHURCH IN LESHOK

Offering a step-change in seismic technology

Strengthening of concrete members by means of carbon fiber reinforced polymers (CFRP)

DIN EN : (E)

VARIOUS TYPES OF SLABS

INFLUENCE OF PRSTRESS LEVEL ON SHEAR BEHAVIOR OF SEGMENTAL CONCRETE BEAMS WITH EXTERNAL TENDONS

BEHAVIOR OF REINFORCED CONCRETE BEAM WITH OPENING

Ultimate strength prediction for reinforced concrete slabs externally strengthened by fiber reinforced polymer (FRP)

SEISMIC STRENGTHENING AND REPAIR OF REINFORCED CONCRETE SHEAR WALLS

VALLIAMMAI ENGINEERING COLLEGE

Experimental and numerical validation of the technical solution of a brace with pinned connections for seismic-resistant multi-story structures

(a) Pin-Pin P cr = (b) Fixed-Fixed P cr = (d) Fixed-Pin P cr =

Product overview:

Contents. Short Report on Shear Strengthening with TRC under non predominantly static loading V 472

FLEXURAL AND SHEAR STRENGTHENING OF REINFORCED CONCRETE STRUCTURES WITH NEAR SURFACE MOUNTED FRP RODS

STRENGTHENING STEEL-CONCRETE COMPOSITE BRIDGES WITH HIGH MODULUS CARBON FIBER REINFORCED POLYMER (CFRP) LAMINATES

Introduction to Structural Analysis TYPES OF STRUCTURES LOADS AND

PRELOADING EFFECT ON LOAD CAPACITY AND DUCTILITY OF RC BEAMS STRENGTHENED WITH PRESTRESSED CFRP STRIPS

Seismic Evaluation and Retrofit of Beam- Column Joints of Mid-America Bridges Part 2: Steel Sheet and Plate Retrofit

THE DESIGN AND INSTALLATION OF A FIVE-STORY NEW TIMBER BUILDING IN JAPAN

VOLUNTARY - EARTHQUAKE HAZARD REDUCTION IN EXISTING HILLSIDE BUILDINGS (Division 94 Added by Ord. No. 171,258, Eff. 8/30/96.)

Introduction to Earthquake Engineering Behaviour of structures under earthquakes

Strengthening of hollow core precast slabs using FRP composite materials procedure, testing and rating

PRESENTATION OF NIKER EU PROJECT

Code No: R Set No. 1

Masonry and Cold-Formed Steel Requirements

Implementing an innovative renovation concept by using force and deformation measurement technology

EXPERIMENTAL STUDY REGARDING THE BEHAVIOR OF GLUE LAMINATED BEAMS DOUBLE REINFORCED WITH RECTANGULAR METAL PIPES (RMP)

Effect of Bar-cutoff and Bent-point Locations on Debonding Loads in RC Beams Strengthened with CFRP Plates

Stresses in bracings due to lateral torsional buckling of beams

Upgrading ductility of RC beam-column connection with high performance FRP laminates

AN EXPERIMENTAL STUDY ON ANCHORAGE OF TENSILE REINFORCEMENT OF WALL-COLUMNS AT THE TOP STORY OF RC WALL-FRAME STRUCTURES WITH FLAT-BEAMS

Numerical study of in-plane behavior of masonry walls strengthened by vertical CFRP strips

Core, Structure, Design

Optimal design solutions for structures using ANSYS software

EFFECT OF EXTERNAL PRESTRESSING ON STEEL ARCHES

Flexural strengthening of reinforced concrete beams using externally bonded FRP laminates prestressed with a new method

Analytical prediction of tension force on stirrups in concrete beams longitudinally reinforced with CFRP bars

LOAD BEARING CAPACITY OF TRADITIONAL ROOF STRUCTURES MODELLING OF JOINTS

REHABILITATION OF TWO HISTORICAL BRIDGES IN BAILE HERCULANE ROMANIA

Load-Carrying Behaviour of Connectors under Shear, Tension and Compression in Ultra High Performance Concrete

LOAD TESTS ON 2-SPAN REINFORCED CONCRETE BEAMS STRENGTHENED WITH FIBRE REINFORCED POLYMER

Analysis on Local Compression Bearing Capacity of Reinforced Concrete Corbels Constrained by Prestress YIN Xinsheng1,a, LIU Yang1,b,WANG Jing1,c

EXPOSURE TEST AND LONG-TERM CHARACTERISTICS FOR CFRP STRUCTURAL MEMBERS

DETERMINATION OF ULTIMATE FLEXTURAL CAPACITY OF STRENGTHENED BEAMS WITH STEEL PLATES AND GFRP INTRODUCTION

FINITE ELEMENT AND LIMIT ANALYSIS OF THE LARGE SCALE MODEL OF MUSTAFA PASHA MOSQUE IN SKOPJE STRENGTHENED WITH FRP

Reconstruction and Seismic Strengthening of the Blown Up Cathedral Church of the Holy Trinity in Mostar

Department of Civil Engineering, UIT, RGPV, Bhopal, India

Analytical study of a 2-span reinforced concrete beam strengthened with fibre reinforced polymer

NPTEL Course. GROUND IMPROVEMENT Factors affecting the behaviour and performance of reinforced soil

composite elements, lateral loads, strain analysis, behavior Composite steel concrete elements made by steel and concrete are used in world wide almos

Wood-based beams strengthened with FRP laminates Improved performance with pre-stressed systems

UHPC Connection of Precast Bridge Deck

EFFECT OF EMBEDMENT LENGTH ON THE PERFORMANCE OF SHEAR-STRENGTHENED RC BEAMS WITH L-SHAPED CFRP PLATES

Displacement Based Assessment and Improvement of a Typical New Zealand Building by an Average Engineer

Damage assessment of hollow core reinforced and prestressed concrete slabs subjected to blast loading

A Study on the Effect of Shear Connectors in Composite Beams

COMPOSITE BRIDGES WITH PRECAST CONCRETE SLABS

L Shaped End Anchors to Eliminate Premature Plate End Debonding in Strengthened RC Beams

Introduction. Structures may be classified on the basis of materials used for construction, as follows: Steel structures. Aluminium structures

SIGNIFICANCE OF SHEAR WALL IN FLAT SLAB MULTI STORIED BUILDING - A REVIEW. Vavanoor, India

PORTAL FRAMES 1.0 INTRODUCTION

STRENGTHENING OF CONCRETE SLAB, BEAM AND COLUMN

International Journal of Advance Engineering and Research Development ANALYTICAL INVESTIGATION OF ENCASED COMPOSITE BEAMS UNDER FLEXURE AND TORSION

AFRP retrofitting of RC structures in Japan

The Rendsburg High Bridge across the Kiel Canal

mortarless Design Manual Part 1 (AS 3600:2009) Section 1 Page 1 AS 3600:2009 PLAIN AND REINFORCED CONCRETE - CODE OF PRACTICE

Numerical Analysis of Strengthening R.C Slabs with Opening using Ferrocement Laminates

Optimized High-Performance Concrete in Grouted Connections

Reconstruction of Space Steel Constructions

CHAPTER 5 BEHAVIOUR OF BEAM-COLUMN JOINT UNDER CYCLIC LOADING

Structural Characteristics of New Composite Girder Bridge Using Rolled Steel H-Section

Finite Element Analysis of the Seismic Performance of a Historical Masonary Cistern

Transcription:

The stabilization of the gothic roof bearing structure of the Frauenkirche in MeiBen with CFRP-tension O. Kempe Ingenieurbuero Kempe GmbH, Dresden, Germany Email: olaf.kempe@t-online.de Abstract The historic, especially valuable gothic roof bearing structure of the Frauenkirche in MeiBen has been stabilized by the building in of Carbon fibre reinforced plastics - loops (CFRP) and therefore further deformation and damage to the whole church construction has been limited. Commencing from an analysis of the existing state, different versions for the stiffening of a historical bearing structure were simulated. Figure 1: Longitudinal section of the gothic church with baroque tower curia [1]

580 Structural Studies, Repairs and Maintenance of Historical Buildings 1 The Frauenkirche of the City of Meifien The Frauenkirche in the market square has been dominating the city centre of the more than 1000 years old town MeiBen. Therefore the reconstruction of this church has become of great importance during the complex town redevelopment. The Frauenkirche in its present form was built as a town church in the early 15th century. It was first mentioned in 1205. The roof truss was added to the churches aisle in about 1447 according to dendrochronological examinations. The church in its form and construction is a typical example of gothic style architecture within Saxony. Figure 2: Cross-section with principal rafter A5 [1]

Structural Studies, Repairs and Maintenance of Historical Buildings 581 Figure 3: Ground-plan with principal rafters A1-A5 [1]

582 Structural Studies, Repairs and Maintenance of Historical Buildings 2 The importance of the roof structure of the Frauenkirche Due to the importance of the gothic roof structure, as one of the last of its special kind in the east of Germany, the reconstruction was not a routine repair. The task was conceptional, reconstructing the roof truss with regards to current preservation orders. From a detailed analysis of the existing entire structure, a diagnosis was found. This was the basis for a therapy with minimal reconstruction measures [2]. In particular the historic roof bearing structure in its originality is a technical monument and should be preserved in its appearance. Therefore new stiffening had to be clearly identifiable as additional reconstruction measures. On the other hand they had to be in harmony with there surroundings but also reversibly, without destroying its aesthetics. To meet this challenge, which was also demanded by the Saxon Commission on Historic Monuments, extensive version examinations were developed in regard to the material, the shape and the technique of possible stiffening. 3 Damages and analysis The following substantial damages were discovered in the roof truss of the Frauenkirche MeiBen and resulting damages were found out the supporting masonry: a) Destroyed connections between the lower collar beam and the rafters and braces, b) Strong deformation of the framework in general, in particular, within the area between the lower collar beam and the base point, c) Damages caused by the infestation of insects and fungus, mainly in the bottom areas of the braces, truss posts, stubs of ceiling beams and wall plates, d) Constructive damages to the longitudinal framework within the choir area and damages caused by erroneous repairs in the past e) Cracks in the masonry between the load-bearing longitudinal walls and the connected transept vault over the nave (see Figure 3). 4 Diagnosis and existing construction From the analysis and static-calculated tests the following results derived: a) The gothic vault reaches into the roof truss with a strong camber in such a way, that the connecting anchorage beams (tension beams) are missing in the collar roof (see Figure 2-8). Therefore the lowest collar beams received tensile forces which they could not transfer to the rafters via their connections. At these points the treenail connections were overloaded by 250 %.

Structural Studies, Repairs and Maintenance of Historical Buildings 583 b) The maximum permissible stress of the rafters and braces was exceeded by c) The maximum horizontal displacement towards the outside caused by stress amounted to 6.1 cm at the rafter base. The calculations as well as the existing deformation state give evidence, that the roof truss was in motion and that the wooden timber fastener opened. The masonry of the nave received serious shearing forces from the roof. This fact is underlined by the filled in cracks of the transept vault of the nave, which are gaping again and which have a total width of up to 4 cm (!). Therefore it can be concluded, that the repair and reconstruction of the truss in its old form alone would not be sufficient enough to guarantee its entire stability and to prevent the masonry from other damages in the future. 5 Therapy and preplanning To strengthen or even better to relieve the load on the collar connections and to reduce the horizontal forces and displacements of the base points and the tensions inside the rafters and braces additional measures for the strengthening of the construction had to be taken. A three-dimensional model of the roof bearing structure with all details and deformations deriving from the analysis was established in the FEM-program ANSYS in order to weigh up alternative preliminary considerations and versions for the stiffening. Eight important load combinations where applied; temperature stress, wind stress, snow load (stress) and dead load according to DIN were used. Figure 4: Isometric of FE-model with CFRP-tension and horizontal bracing

584 Structural Studies, Repairs and Maintenance of Historical Buildings In order to realize the idea of a remedial reconstruction that is reversible and where the truss remains its status as a architectural listed building historical design weaknesses should be kept. Additional structures that shift loads from weak points should compensate and relieve the load from the historic system. The main points of the verification process for the constructive solution of this reinforcement were based on: Figure 6: Principal rafter type Bl a) the material to be use for the bracing and crossing of the truss; b) the shape of a bracing and crossing; c) the reinforcement of each brace level or just individual levels and the opportunity of directing the shearing forces of the unstrengthened levels into the neighbouring strengthened levels. Figure 7: Principal rafter type Cl Figure 5: Principal rafters type A1-C1-B1 Figure 8: Principal rafter type Al CFRP-tensioned

Structural Studies, Repairs and Maintenance of Historical Buildings 585 to a): A discreet form of steel, GFRP and CFRP for the strengthening, that fits into the historic construction, would be fundamentally possible. Due to the large crosssection a stiffening with timber would contradict this idea. A steel-bracing would efficiently relive the bearing structure. However, under a temperature stress of +50 C in summer and -20 C in winter, that means 70K, a displacement of the base points of the framework of 1.2 cm would occur. GFRPprestressing bars, in this case, had a very elastic behaviour and were not temperature neutral. A CFRP-bracing resulted in the best values of stress and deformation for all loading types. The reason for this are a neutral behaviour in terms of temperature and the high stiffness of the material. Moreover it has positive characteristics of corrosion resistance and the characteristic of having a minimal weight while having the highest stability. The necessary cross-section under use of TORAY M40J fibres for the loops accounts for only twice 5x30 mm. tob): Within the analyses it proved favourable to add the elements of the reinforcement, which are to be build in, to the existing joints of the trussed framework. The problem of connecting CFRP, that is sensitive to load was solved by the loop shape of the tension elements. toe): Each of the brace levels shows a different degree of stiffening in its historic state, that can partially be levelled out by the two amply sized wall plates. Because of the excellent material characteristics of CFRP, in particular because of the high tensile strength, it follows that the historic concept, where only every fourth level is reinforced, can be employed. The results of the version examinations underline this. In order to transfer forces of the neighbouring levels into the reinforced levels, it will be possible with a little expense to join the two wall plates to a trussed beam of horizontal location with a high stiffness. The described version indicates minimal displacements of the truss base point for different loads. Moreover it efficiently relieves the load on so far overloaded parts and connecting elements, and it fits appropriately into the existing roof truss. Therefore it is favourable as the most convenient solution.

586 Structural Studies, Repairs and Maintenance of Historical Buildings IfcL Figure 9: Realisation planning CFRP truss level Al, connecting detail of CFRPloop

Structural Studies, Repairs and Maintenance of Historical Buildings 587 6 Therapy / planning - realisation The aim of the detailed planning was to minimize the existing tensile strengths of the lower collar beams in such a way, that they can be supported by a dovetail plate with a firm (non-slipping) oak timber nail. At the same time the CFRP-bracing should be reduced in the cross-section, in order to economize material. For these reasons the CFRP-loops were partially prestressed, in order to anticipate the existing dead load of the roof structure. The induction of the prestress is done by the tightening of the turnbuckle nuts. As the CFRP-loops are linked (sometimes) at an angle within the historic timber roof truss the loops were borne with 1 mm neoprene as an intermediate layer at the drape points. The calculated deformations, in particular the deformations at the base points are minimal and they result from the elasticity of the stressed total system. The tension reaches a maximal value of 84 % of the permissible value within a wall plate segment. The rafters, collar beams, the head runners and brace beams have a remarkably low use of capacity, that does not exceed 50 %. The prove of stability is therefore produced for all parts. 7 Experimental stability test on CFRP-parts In order to ensure realistic examination of the CFRP-loops, that were produced by the German Institute of Air- and Universal Technic, the loops were examined separately and together with the connecting parts in 5 single tests in regard to their behaviour at the EMPA in Dubendorf [3]. The target was to determine the maximum load-bearing capacity of the single CFRP-loops and to find out the expansion characteristics of the whole arrangement. In test A the total arrangement with collar connection and bearing of 2x2 CFRP-loops were checked in neoprene stripes (70 Shore hardness) of 1 mm thickness up to a stress of 60 kn. In test D afracturetest up to 175 kn was carried out with a short loop of 1800 mm, whose lower base point had a deflection of 2 stiff and with neoprene-bearing.

588 Structural Studies, Repairs and Maintenance of Historical Buildings test A testd 12 j 10-- E 8-- /r 70 -H 60 - / 0,2 0,4 0,6 0,8 strain/1000 2,0 4,0 strain 1/1000 Figure 10: Stress-strain diagram of the test A and D The breaking tension of 175 kn with inclined bearing application in neoprene for a CFRP-loop lies with a certainty of 4.4 fare over the maximal occurring value of 39 kn. The module E results in approximately 190,000 N/mm^ from the analysis of the ingenious part results of the single tests. Therefore the material 'CFRP-loops' is suitable for use. 8 Conclusions During the redevelopment of the gothic roof bearing structure of the Frauenkirche in MeiBen the suitability of the material CFRP for the reinforcement of such timber roof structures could first be proved. Due to the specific characteristics of the material it opens up new opportunities in particular to curatorial respects, that show the employment of CFRP appears to be promising for the redevelopment of buildings in the future. References [1] Gurlitt, C, Beschreibende Darstellung der alteren Bau- und Kunstdenkmaler des Konigreiches Sachsen; Heft 39, Stadt Meifien, Meinholf & Sohne, Dresden 1917 [2] Wenzel, F., Konzeptionen SFB 315, University of Karlsruhe, Heft 9/1989, [3] EMPA-report No 15 T 060, Dachstuhl-Verspannung, EMPA Dubendorf, 3/1994