DIVISION: CONCRETE SECTION: CONCRETE ACCESSORIES SECTION: REINFORCING STEEL REPORT HOLDER: TENDON SYSTEMS, LLC

Similar documents
DIVISION: CONCRETE SECTION: CONCRETE ACCESSORIES SECTION: REINFORCING STEEL REPORT HOLDER: SRL INDUSTRIES LTD.

DIVISION: CONCRETE SECTION: CONCRETE ACCESSORIES SECTION: REINFORCING STEEL REPORT HOLDER: EVALUATION SUBJECT:

DIVISION: CONCRETE SECTION: CONCRETE ACCESSORIES DIVISION: CONCRETE SECTION: REINFORCING STEEL REPORT HOLDER:

DIVISION: CONCRETE SECTION: CONCRETE ACCESSORIES SECTION: REINFORCING STEEL REPORT HOLDER: PJ S REBAR INC.

DIVISION: CONCRETE SECTION: CONCRETE ACCESSORIES SECTION: REINFORCING STEEL REPORT HOLDER: PEIKKO GROUP, INC.

DIVISION: METALS SECTION: METAL FASTENINGS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

DIVISION: METALS SECTION: METAL FABRICATIONS REPORT HOLDER: AKRON PRODUCTS COMPANY

DIVISION: CONCRETE SECTION: CONCRETE ACCESSORIES REPORT HOLDER: NELSON STUD WELDING, INC WEST RIDGE ROAD ELYRIA, OHIO 44036

DIVISION: METALS SECTION: METAL FASTENINGS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 100 PLANO, TEXAS 75024

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: NAILS REPORT HOLDER: BOSTITCH FASTENING SYSTEMS

DIVISION: METALS SECTION: METAL FABRICATIONS REPORT HOLDER: QUALITY WAY PRODUCTS, LLC 407 HADLEY STREET HOLLY, MICHIGAN 48442

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT:

DIVISION: FINISHES SECTION: GYPSUM BOARD ACCESSORIES REPORT HOLDER: GRABBER NAILS FOR GYPSUM WALLBOARD INSTALLATION

REPORT HOLDER: JAACO CORPORATION NE 68 TH STREET, SUITE C 130 REDMOND, WASHINGTON EVALUATION SUBJECT:

DIVISION: METALS SECTION: METAL RAILINGS REPORT HOLDER: ULTRALOX 2955 LONE OAK DRIVE, SUITE 180 EAGAN, MINNESOTA 55121

REPORT HOLDER: BLUE POINT FASTENING, INC YORBA COURT CHINO, CALIFORNIA EVALUATION SUBJECT:

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT: HILTI LOW-VELOCITY POWER-ACTUATED FASTENERS

DIVISION: OPENINGS SECTION: VENTS/FOUNDATION FLOOD VENTS REPORT HOLDER: SMARTVENT PRODUCTS, INC.

DIVISION: CONCRETE SECTION: REINFORCING STEEL REPORT HOLDER: SAS STRESSTEEL INC. 100 NEW DUTCH LANE FAIRFIELD, NEW JERSEY 07004

DIVISION: METALS SECTION: METAL RAILINGS REPORT HOLDER: CPG INTERNATIONAL LLC DBA THE AZEK COMPANY LLC EVALUATION SUBJECT:

DIVISION: METALS SECTION: METAL FASTENINGS REPORT HOLDER: GRABBER CONSTRUCTION PRODUCTS, INC.

DIVISION: METALS SECTION: METAL FASTENINGS REPORT HOLDER: CLARKDIETRICH BUILDING SYSTEMS LLC

REPORT HOLDER: FASTENING SPECIALISTS, INC. 726 CENTRAL FLORIDA PARKWAY ORLANDO, FLORIDA EVALUATION SUBJECT:

Trusted ICC ES HILTI, INC. Evaluation. report, or as to any. ICC-ES Evaluation

DIVISION: OPENINGS SECTION: VENTS/FOUNDATION FLOOD VENTS REPORT HOLDER: FLOOD FLAPS, LLC

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: ITW BUILDEX 700 HIGH GROVE BOULEVARD GLENDALE HEIGHTS, ILLINOIS 60139

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: APPLIED FIREPROOFING REPORT HOLDER: FLAMEOFF COATINGS, INC. EVALUATION SUBJECT:

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT: HILTI LOW-VELOCITY POWER-ACTUATED FASTENERS

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP FABRICATED WOOD TRUSSES REPORT HOLDER: MITEK USA, INC.

DIVISION: CONCRETE SECTION: REINFORCING STEEL REPORT HOLDER: MMFX TECHNOLOGIES A COMMERCIAL METALS COMPANY

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CLAY ROOF TILES REPORT HOLDER: BORAL ROOFING LLC

DIVISION: OPENINGS SECTION: VENTS/FOUNDATION FLOOD VENTS REPORT HOLDER: FLOOD FLAPS, LLC EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL WALL PANELS REPORT HOLDER: FCP, INC.

REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CONCRETE ROOF TILES REPORT HOLDER: BARTILE ROOFS, INC. EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: KAYCAN LTD.

REPORT HOLDER: GRABBER CONSTRUCTION PRODUCTS, INC. EVALUATION SUBJECT: GRABBER FASTENERS FOR USG STRUCTURAL PANELS

DIVISION: METALS SECTION: METAL RAILINGS REPORT HOLDER: ULTRALOX EVALUATION SUBJECT:

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH 5000 SERIES FASTENERS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: KP BUILDING PRODUCTS

DIVISION: CONCRETE SECTION: REINFORCING STEEL REPORT HOLDER: DEXTRA MANUFACTURING CO., LTD. EVALUATION SUBJECT:

DIVISION: CONCRETE SECTION: REINFORCING STEEL REPORT HOLDER: DEXTRA MANUFACTURING CO., LTD.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER: MITEK USA, INC.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: NAILS REPORT HOLDER: PASLODE, AN ILLINOIS TOOL WORKS COMPANY

REPORT HOLDER: CLARKDIETRICH BUILDING SYSTEMS 9050 CENTRE POINTE DRIVE, SUITE 400 WEST CHESTER, OHIO EVALUATION SUBJECT:

ESR-2036 Reissued May 1, 2013 This report is subject to renewal June 1, 2015.

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH 3000 SERIES FASTENERS

DIVISION: CONCRETE SECTION: MAINTENANCE OF CONCRETE REPORT HOLDER: STRUCTURAL TECHNOLOGIES, LLC

DIVISION: METALS SECTION: COLD FORMED METAL FRAMING REPORT HOLDER: AEGIS METAL FRAMING, A DIVISION OF MITEK

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH BRAND FASTENERS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CLAY ROOF TILES REPORT HOLDER: TEJAS BORJA USA EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: CERTAINTEED CORPORATION

DIVISION: MASONRY SECTION: MANUFACTURED BRICK MASONRY SECTION: MANUFACTURED STONE MASONRY REPORT HOLDER:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: NAILS REPORT HOLDER: HY-TEK FASTENERS INC. EVALUATION SUBJECT: HY-TEK NAILS

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT EVALUATION SUBJECT:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PLASTICS SECTION: PLASTIC DECKING REPORT HOLDER:

Trusted ICC ES MILAN ITALY SYSTEMS. Look. Conformity! Evaluation. ICC-ES Evaluation

DIVISION: CONCRETE SECTION: REINFORCING STEEL REPORT HOLDER: BARSPLICE PRODUCTS INC WEBSTER STREET DAYTON, OHIO

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: NCFI POLYURETHANES

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING FELT AND UNDERLAYMENT REPORT HOLDER: ENVIRONMENTALLY SAFE PRODUCTS, INC.

Trusted ICC ES. Conformity! Look. Evaluation. ICC-ES Evaluation

Trusted SECTION: 04 HILTI, INC. TULSA, Conformity! ICC-ES Evaluation. not specifically. Copyright 2015

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: PLASTIC DECKING REPORT HOLDER: SILCA SYSTEM

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PLASTICS REPORT HOLDER: HB&G BUILDING PRODUCTS, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: NCFI POLYURETHANES EVALUATION SUBJECT:

REPORT HOLDER: HILTI, INC. EVALUATION SUBJECT: HILTI LOW VELOCITY X-U AND X-U 15 UNIVERSAL FASTENERS AND X-P CONCRETE FASTENERS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: SIDING REPORT HOLDER: SHAKERTOWN 1992, INC.

DIVISION: CONCRETE SECTION: POST-TENSIONED CONCRETE REPORT HOLDER: GENERAL TECHNOLOGIES, INC.

REPORT HOLDER: HILTI, INC. EVALUATION SUBJECT: HILTI LOW-VELOCITY POWER-ACTUATED FASTENERS

DIVISION: METALS SECTION: METAL FASTENINGS DIVISION: FINISHES SECTION: FASTENERS REPORT HOLDER: HILTI, INC.

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS REPORT HOLDER: PAREX USA, INC.

DIVISION: METALS SECTION: COLD FORMED METAL FRAMING REPORT HOLDER: AEGIS METAL FRAMING, A DIVISION OF MITEK

REPORT HOLDER: GEORGIA PACIFIC GYPSUM LLC 2861 MILLER ROAD DECATUR, GEORGIA EVALUATION SUBJECT: DENSELEMENT BARRIER SYSTEM

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP-FABRICATED WOOD TRUSSES REPORT HOLDER: EAGLE METAL PRODUCTS

DIVISION: EARTHWORK SECTION: BORED PILES REPORT HOLDER: GEOTECH ENTERPRISES, INC.

REPORT HOLDER: PAREX USA, INC EAST LA PALMA AVENUE, SUITE 250 ANAHEIM, CALIFORNIA EVALUATION SUBJECT:

Trusted ICC ES TEK USA, Evaluation. report, or as to any. ICC-ES Evaluation

REPORT HOLDER: STEEL STUD MANUFACTURERS ASSOCIATION (SSMA) 35 EAST WACKER DRIVE, SUITE 850 CHICAGO, ILLINOIS EVALUATION SUBJECT:

REPORT HOLDER: SOPREMA, INC. 310 QUADRAL DRIVE WADSWORTH, OHIO EVALUATION SUBJECT:

DIVISION: CONCRETE SECTION: POST-TENSIONED CONCRETE REPORT HOLDER: PRECISION-HAYES INTERNATIONAL

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP-FABRICATED WOOD TRUSSES REPORT HOLDER: MITEK USA, INC.

DIVISION: CONCRETE SECTION: SPECIALTY PLACED CONCRETE REPORT HOLDER: EMMEDUE S.P.A.

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: POWERS FASTENERS, INC. 701 EAST JOPPA ROAD TOWSON, MARYLAND 21286

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP FABRICATED WOOD TRUSSES REPORT HOLDER: MITEK USA, INC.

REPORT HOLDER: OLMAR SUPPLY INC RESEARCH DRIVE LIVERMORE, CALIFORNIA EVALUATION SUBJECT:

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP FABRICATED WOOD TRUSSES REPORT HOLDER: MITEK USA, INC.

REPORT HOLDER: BASF CORPORATION EVALUATION SUBJECT: MASTERSEAL AWB 660 I VAPOR RETARDER, AIR AND WATER-RESISTIVE BARRIER AND FLEXIBLE FLASHING

REPORT HOLDER: CALIFORNIA EXPANDED METAL PRODUCTS COMPANY (CEMCO) CROSSROADS PARKWAY NORTH, SUITE 325 CITY OF INDUSTRY, CALIFORNIA 91746

DIVISION: MASONRY SECTION: CONCRETE UNIT MASONRY REPORT HOLDER: 3B CONSTRUCTION SOLUTIONS, INC.

DIVISION: CONCRETE SECTION: MAINTENANCE OF CONCRETE DIVISION: MASONRY SECTION: MAINTENANCE OF UNIT MASONRY

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT:

DIVISION: METALS SECTION: COLD FORMED METAL FRAMING REPORT HOLDER: AEGIS METAL FRAMING, A MITEK COMPANY

DIVISION: FINISHES SECTION: SUSPENSION SYSTEMS SECTION: ACOUSTICAL CEILING SUSPENSION ASSEMBLIES REPORT HOLDER:

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: 5956 WEST LAS POSITAS BOULEVARD PLEASANTON, CALIFORNIA 94588

Transcription:

0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 42-6587 (562) 699-054 www.icc-es.org ESR-900 Issued 08/2017 This report is subject to renewal 08/2018. DIVISION: 0 00 00 CONCRETE SECTION: 0 15 00 CONCRETE ACCESSORIES SECTION: 0 21 00 REINFORCING STEEL MIDLAND, GEORGIA 1820 Look for the trusted marks of Conformity! 2014 Recipient of Prestigious Western States Seismic Policy Council (WSSPC) Award in Excellence A Subsidiary of ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as Copyright 2017 ICC Evaluation Service, LLC. All rights reserved.

ICC-ES Evaluation Report ESR-900 Issued August 2017 This report is subject to renewal August 2018. www.icc-es.org (800) 42-6587 (562) 699-054 A Subsidiary of the International Code Council DIVISION: 0 00 00 CONCRETE Section: 0 15 00 Concrete Accessories Section: 0 21 00 Reinforcing Steel MIDLAND, GEORGIA 1820 678-85-1100 www.tendonllc.com 1.0 EVALUATION SCOPE Compliance with the following codes: 2015 International Building Code (IBC) 2012, 2009 and 2006 International Building Code * 201 Abu Dhabi International Building Code (ADIBC)* *Codes indicated with an asterisk are addressed in Section 8.0. Property evaluated: Structural 2.0 USES The TSSR Shearails are used as shear reinforcement in reinforced concrete slabs to replace stirrups, drop panels or column capitals to increase the punching shear resistance of the slabs..0 DESCRIPTION.1 General: The TSSR Shearails are reinforcement assemblies that are formed by welding large-headed shear studs to steel base rails. The studs are provided in -, 1 / 2 -, 5 - and / 4 -inch (9.5, 12.7, 15.9, and 19.1 mm) diameters. The stud dimensions are given in Table 1 and base rail dimensions are given in Table 2. The assembly configuration is shown in Figure 1. The TSSR Shearails comply with the provisions of ASTM A1044..2 Materials:.2.1 Studs: Studs are produced from ASTM A29 Grade 1010 through 1020 steel and conform to the following physical and mechanical requirements prescribed in Table 1 of ASTM A1044. Tensile strength, min, psi [MPa]: 65,000 [450] Yield strength, min, psi [MPa]: 51,000 [50] Elongation in 2 in. [50 mm], min, %: 20 Reduction of area, min, %: 50.2.2 Base Rails: Base rails are produced from steel plates conforming to ASTM A6 and the following physical and mechanical requirements prescribed in Table 2 of ASTM A1044. Tensile strength, min, psi [MPa]: 65,000 [450] Yield strength, min, psi [MPa]: 44,000 [00] Elongation in 8 in. [200 mm], min, %: 20 4.0 DESIGN AND INSTALLATION 4.1 Design: 4.1.1 General: Structural design and installation of TSSR Shearails used as punching shear reinforcement in reinforced concrete slabs must comply with the applicable provisions of ACI 18-14 (2015 IBC). The specified yield strength of transverse reinforcement, f yt, must not exceed the specified yield strength of the shear studs defined in Section.2.1. 4.1.2 Design Considerations: The structural design of TSSR Shearails must determine and specify the following items, based on design requirements in this report: a. The number of studs per rail. b. Stud shank diameter. c. Base rail length. d. Shear rail assembly overall height (OH), which must comply with Section 8.7.7.1.1 of ACI 18-14. e. Stud spacing (s). f. Distance between column face and first peripheral line of studs (S o ). g. Arrangement of headed shear stud reinforcement, which must comply with Section 8.7.7.1.2 of ACI 18-14. 4.1. Earthquake Loads: The TSSR Shearails TM may be used at slab-to-column connections of concrete structures where the flat slab is used together with the primary seismic force resisting systems in structures assigned to Seismic Design Categories C, D, E and F, such as concrete shear walls, under the following conditions: 4.1..1 General: Lateral force resisting elements of the structure are designed using the IBC. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as Copyright 2017 ICC Evaluation Service, LLC. All rights reserved. Page 1 of 4

ESR-900 Most Widely Accepted and Trusted Page 2 of 4 4.1..2 Shear Strength: The nominal shear strength provided by the concrete in the presence of the headed shear stud reinforcement, referenced in Section 22.6.6.1 of ACI 18-14, must be revised as follows: VV cc = 1.5λλ ff cc bb oo dd This revision requires revisions to the nominal shear strength, V n, and the maximum shear stress, v n. Two-way slabs without beams designated as part of the seismic-force-resisting system, must comply with the provisions in Section 18.4.5.8 of ACI 18-14, except that V c must be limited as set forth in this section. Two-way slabs without beams, which are not designated as part of the seismic-force-resisting system, must comply with the provisions in Section 18.14.5.1 of ACI 18-14, except that V c must be limited as set forth in this section and the design story drift ratio specified in Section 18.14.5.1 of ACI 18-14 must not exceed the drift ratio referenced in Table 12.12-1 of ASCE/SEI 7. 4.2 Installation: Installation of the TSSR Shearails must comply with the applicable code and the approved engineering plans. The TSSR Shearails must be positioned correctly around columns and set in accordance with the IBC and the approved construction documents. Concrete cover must comply with Section 20.6.1..5 of ACI 18-14. See Figure 2 for a typical installation detail. 4. Special Inspection: Special inspection of TSSR Shearails TM and their installation at the jobsite is required in accordance with IBC Section 1705.. The special inspector is responsible for verifying identification of the TSSR Shearails TM per Section 7.0 of this report, verifying the condition of the TSSR Shearails TM, and verifying that the location, positioning, clearances, and concrete cover for the TSSR Shearails TM comply with the approved engineering plans and the applicable code. 5.0 CONDITIONS OF USE The TSSR Shearails described in this report comply with, or are suitable alternatives to what is specified in, those codes listed in Section 1.0 of this report, subject to the following conditions: 5.1 The TSSR Shearails TM must be designed, manufactured, and installed in accordance with this report and the approved plans. In the event of a conflict between this report and the approved plans, this report governs. 5.2 Calculations and plans must be in compliance with the design requirements of Section 4.1 of this report, must demonstrate that the resistance of the reinforced concrete structure equals or exceeds the applied loads and must be approved by the code official. The calculations and plans must be prepared by a registered design professional when required by the statutes of the jurisdiction in which the project is to be built. 5. Special inspections must be provided in accordance with Section 4. of this report. 5.4 The TSSR Shearails TM are manufactured at the Tendon Systems facility in Midland, Georgia, under a quality-control program with inspections by ICC-ES. 6.0 EVIDENCE SUBMITTED Data in accordance with the ICC-ES Acceptance Criteria for Headed Shear Stud Reinforcement Assemblies for Concrete Slabs and Footings (AC95), dated October, 2008 (editorially revised February 2016). 7.0 IDENTIFICATION Pallets of TSSR Shearails are identified by production order attached to the pallet, which includes the manufacturer s name (Tendon Systems), the product name, the product dimensions, and the evaluation report number (ESR-900). Individual TSSR Shearails are identified by a label with the manufacturer s initials (TS) and paint color indicated on the production order. 8.0 OTHER CODES 8.1 Scope: In addition to the 2015 IBC, the products described in this report were evaluated for compliance with the requirements of the following codes: 2012, 2009 and 2006 International Building Code (IBC) 201 Abu Dhabi International Building Code (ADIBC) The ADIBC is based on the 2009 IBC. 2009 IBC code sections referenced in this report are the same sections in the ADIBC. 8.2 Uses: See Section 2.0. 8. Description: See Section.0. 8.4 Design and Installation: 8.4.1 Design: 8.4.1.1 General: Structural design and installation of TSSR Shearails used as punching shear reinforcement in reinforced concrete slabs must comply with the applicable provisions of ACI 18-11 for the 2012 IBC or AC18-08 for the 2009 IBC, as applicable. Under the 2006 IBC, compliance must be with ACI 18-05 and Sections.5.5, 7.7.5 and 11.11.5 of ACI 18-08. The specified yield strength of transverse reinforcement, f yt, must not exceed the specified yield strength of the shear studs defined in Section.2.1. 8.4.1.2 Design Considerations: The structural design of TSSR Shearails must determine and specify the following items, based on design requirements in this report: a. The number of studs per rail. b. Stud shank diameter. c. Base rail length. d. Shear rail assembly overall height (OH), which must comply with Section 11.11.5 of ACI 18-11 (for the 2012 IBC) or -08 (for the 2009 and 2006 IBC). e. Stud spacing (s). f. Distance between column face and first peripheral line of studs (S o ). g. Arrangement of headed shear stud reinforcement, which must comply with Sections 11.11.5.2 and 11.11.5. of ACI 18-11 or -08. 8.4.1. Earthquake Loads: See Section 4.1.. 8.4.1..1 General: See Section 4.1..1. 8.4.1..2 Shear Strength: The nominal shear strength provided by the concrete in the presence of the headed shear stud reinforcement, referenced in Section 11.11.5.1 of ACI 18-11 or -08, must be revised as shown in Section 4.1..2.

ESR-900 Most Widely Accepted and Trusted Page of 4 This revision requires revisions to the nominal shear strength, V n, and the maximum shear stress, v n. Two-way slabs without beams designated as part of the seismic-force resisting system, must comply with the provisions in Section 21..6.8 of ACI 18-11 (for the 2012 IBC) or -08 (for the 2009 and 2006 IBC), except that V c must be limited as set forth in Section 4.1..2. Two-way slabs without beams, which are not designated as part of the seismic force resisting system, must comply with the provisions in Section 21.1.6 of ACI 18-11 (for the 2012 IBC) or -08 (for the 2009 IBC), or Section 21.11.5 of ACI 18-05 for the 2006 IBC, as applicable, except that V c must be limited as set forth in Section 4.1..2 and the design story drift ratio specified in Section 21.1.6 ACI 18-11 or -08 or Section 21.11.5 of ACI 18-05, as applicable, must not exceed the drift ratio referenced in Table 12.12-1 of ASCE/SEI 7. 8.4.2 Installation: Installation of TSSR Shearails must comply with the applicable code and the approved engineering plans. The TSSR Shearails must be positioned correctly around columns and set in accordance with the IBC and the approved construction documents. Concrete cover must comply with Section 7.7.5 of ACI 18-11 or -08. See Figure 2 for a typical installation detail. 8.4. Special Inspection: See Section 4., except reference Section 1705. of the 2012 IBC and Section 1704.4 of the 2009 and 2006 IBC. 8.5 Conditions of Use: See Section 5.0. 8.6 Evidence Submitted: See Section 6.0. 8.7 Identification: See Section 7.0 TABLE 1 TSSR SHEARAIL STUD DIMENSIONS SHANK DIAMETER, D 1 / 2 (12.7) 5 (15.9) / 4 (19.1) HEAD DIAMETER, H 1.19 (0.1) 1.58 (40.2) 1.98 (50.2) 2.7 (60.2) H/D RATIO.17.16.17.16 SHANK AREA, S A [in. 2 (mm 2 )] 0.110 (71) 0.196 (127) 0.07 (199) 0.442 (287) HEAD AREA, H A [in. 2 (mm 2 )] 1.112 (712) 1.961 (1,269).079 (1,979) 4.412 (2,846) H A /S A RATIO 10.1 HEAD THICKNESS, T 0.26 (6.6) 0. (8.4) 0.40 (10.2) 0.47 (11.9) TABLE 2 BASE RAIL DIMENSIONS STUD SHANK DIAMETER, D 1 / 2 (12.7) 5 (15.9) / 4 (19.1) PLATE WIDTH, W 1.25 (1.8) 1.25 (1.8) 2.00 (50.8) 2.00 (50.8) PLATE THICKNESS, t 0.250 (6.4) 0.250 (6.4) 0.75 0.75 PLATE LENGTH Determined by the registered design professional FIGURE 1 FIGURE 2 TYPICAL TSSR SHEARAIL PLACEMENT

ICC-ES Evaluation Report www.icc-es.org (800) 42-6587 (562) 699-054 ESR-900 FBC Supplement Issued August 2017 This report is subject to renewal August 2018. A Subsidiary of the International Code Council DIVISION: 0 00 00 CONCRETE Section: 0 15 00 Concrete Accessories Section: 0 21 00 Reinforcing Steel MIDLAND, GEORGIA 1820 (678) 85-1100 www.tendonllc.com 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that TSSR Shearails, recognized in ICC-ES master evaluation report ESR-900, have also been evaluated for compliance with the code noted below. Applicable code edition: 2014 Florida Building Code Building 2.0 CONCLUSIONS The TSSR Shearails, described in Sections 2.0 through 8.0 of the master evaluation report ESR-900, comply with the Florida Building Code Building, provided the design and installation are in accordance with the 2012 International Building Code (IBC) provisions noted in the master report. Use of the TSSR Shearails for compliance with the High-Velocity Hurricane Zone provisions of the Florida Building Code Building has not been evaluated and is outside the scope of this supplemental report. For products falling under Florida Rule 9N-, verification that the report holder s quality-assurance program is audited by a quality-assurance entity approved by the Florida Building Commission for the type of inspections being conducted is the responsibility of an approved validation entity (or the code official, when the report holder does not possess an approval by the Commission). This supplement expires concurrently with the master report, issued August 2017. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as Copyright 2017 ICC Evaluation Service, LLC. All rights reserved. Page 4 of 4