An Introduction to the Worldwide Regulatory Framework for Medical Devices. Elizabeth Malo M.S., Director, Regulatory Affairs

Similar documents
By: Clay Anselmo COO, DLLS, Founder Reglera and Terry J. Dagnon M.S., Vice President Regulatory Affairs, DLSS

Introduction to the FDA. Historical Context. Changes over Time FDA - BE-200 9/23/2004. Copyright C. S. Tritt, Ph.D. 1

Paths to Market & FDA Product Lifecycle Regulation. Patricia Kaeding Design of Medical Devices University of Minnesota April 14, 2005

Disclosures. Laboratory Stakeholders. IVD vs. LDT. FDA Regulation of Laboratory Developed Tests 10/2/2015. FDA Regulation of LDTs

Copyright. Jeremiah J. Kelly (2015). All rights reserved. Further dissemination without express written consent strictly prohibited.

Contents. Regulatory Bodies... 13

The Institutional Review Board (IRB) Manual

MEDICAL DEVICE. Technical file.

FDA s Center for Devices and Radiological Health: Strategic Priorities for 2017 and Beyond

INVESTIGATIONAL DEVICES & DRUGS. What is an IRB to do?

Device research sponsors, whether companies or investigators, are held responsible for meeting the same regulations.

3.1. Overall Principal Investigator (PI), who holds the IDE and/or is the Sponsor

Confronting MedTech Start-Ups Three Biggest Challenges: Initiating Regulatory & Quality

Title: Review of Medical Devices Page: 1 of 5 Written by:

U.S. Food and Drug Administration (FDA) Regulatory Pathways for Medical Devices

Medidée Services SA. Nano-Tera.ch. 05 February 2015 part 8. PMA, 510k, IDE. Pierre-Alain Sommer

Pre-Clinical Testing for Devices and Diagnostics

ASQ Tappan Zee Section Medical Devices, New Regulations and Standards. 26 th September / V. Fischer / Rev. 01

Health Industry Alert

was published. February 21, 2017

Regulation of software a medical device

Navigating the FDA, and understanding Medical Device Preemption. Special Counsel Foulston Siefkin

U.S. FDA CENTER FOR DEVICES AND RADIOLOGICAL HEALTH UPDATE. Jeff Shuren Director Center for Devices and Radiological Health

Combination Products at US FDA

Draft Guidance for Industry, Clinical Laboratories, and FDA Staff. In Vitro Diagnostic Multivariate Index Assays

Developing a Companion Diagnostics in parallel to a medicinal product Legal and Regulatory requirements in Europe and in the US

Ready or Not: The New Medical Device Regulations Are Here!

The Children s Hospital of Philadelphia Committees for the Protection of Human Subjects Policies and Procedures Determination of IND/IDE Requirement

MCW Office of Research Standard Operating Procedure

Evolving Regulatory Pathways for Medical Devices FDLI Annual Conference Access materials at fdli.org/annual2018

RE: Docket No. FDA 2017 N 0041: Agency Information Collection Activities; Proposed Collection; Comment Request; Safety Assurance Case

Medical Device Regulatory Framework 9 SEPTEMBER 2015 FUNDISA CONFERENCE JANE ROGERS

Medical Device Regulatory Roadmap SAMED Conference 2-3 December 2015

ATELIER RÈGLEMENTAIRE DM US/CANADA

FDA Regulation of Testing

Self-Care Medical Devices Framework. Dr. Simone Breitkopf Head HEOR, Governmental and Public Affairs

Support for the National Accreditation Centre MOLDAC to successfully undergo the EA peer evaluation process. Twinning Project MD14/ENPI/TR/20

Regulatory Framework for Medical Device

CBER Regulation of Devices for Cell Therapy

Standard and Directives on Medical Devices

Regulatory Overview of Proposed LDT Framework. FDA Concerns. Background. FDA Proposed Regulatory Approach. By Ben Berg, Meaghan Bailey, RAC

Course Title ID Duration Basic Premium. Biological Evaluation of Medical Devices: A Risk-Based Approach N mins

The FDA/CDRH Perspective in the Regulation of Surgical Mesh

IVD Regulation Update

Medical Device Regulatory Roadmap SAMED Conference 2-3 December 2015

Role of the WHO IVD Prequalification Programme in Light of National Regulatory Authority Approval

The Long and Winding Road of Unique Device Identifier (UDI) Implementation: A Small Company Perspective

fix Menu FDA Pharm 411 Medical Devices Overview of Device Regulations

Bioresearch Monitoring Inspections in Vitro Diagnostics Devices

October 25, Division of Dockets Management (HFA-305) Food and Drug Administration 5630 Fishers Lane, Room 1061 Rockville, MD 20852

De Novo Classification Process (Evaluation of Automatic Class III Designation) Guidance for Industry and Food and Drug Administration Staff

Med-Info. Directive 98/79/EC on in-vitro diagnostic medical devices. TÜV SÜD Product Service GmbH

Medical Devices; Immunology and Microbiology Devices; Classification of the Automated

Bridging gaps: medical device directive vs regulation. Geert Corstens 1 November 2018

Impact of the IVD Regulations. Barbara Fallowfield Managing Director

Molecular Diagnostics: The Shift to Complexity. Molecular Diagnostics Regulation: Where do we go from here? David W Feigal, Jr.

Digital Health A PRAGMATIC REGULATORY APPROACH

January 3, AtriCure Inc. Melissa Smallwood Associate Regulatory Affairs Specialist 7555 Innovation Way Mason, Ohio 45040

Incorporating FDA Regulatory Thinking into Plans for Medical Devices

CRNs as Foundational Blocks of the National Evaluation System for Medical Devices: A Call to Action

The In Vitro Diagnostic CRO

Perspective: New European IVD Regulations New Concepts for Market Authorizations and Product Launch Schedules

CDRH Device Approval

David W Feigal, Jr., MD MPH

Medical Device Accessories: Defining Accessories and Classification Pathway for New Accessory Types. Draft Guidance for Industry and

Medical Devices; Exemption From Premarket Notification; Class II Devices; Autosomal

MEDICAL DEVICE CLINICAL INVESTIGATIONS AND ISO 14155

The Intersection of Genomics Research and the IDE Regulation

Research Involving FDA Regulated Devices Policy 606 Version: 1.1 POLICY

Issues in Clinical Trial Designs for Devices

Real World Evidence Generation in the 21 st Century: National Evaluation System for health Technology (NEST)

Deciding When to Submit a 510(k) for a Change to an Existing Device Guidance for Industry and Food and Drug Administration Staff

Draft Guidance for Industry and FDA Staff Premarket Notification [510(k)] Submissions for Medical Devices that Include Antimicrobial Agents

11.0 FDA-Regulated Research Research Involving Investigational Drugs and Biologics

Due diligence in the European medical devices industry

DRUG DRAFT GUIDELINE FOR REGISTRATION OF MEDICAL DEVICES FOR HUMAN USE IN UGANDA, SEPTEMBER 2009

Medical Device Labeling HealthPack 2004 Program

IVDR Breakout. Copyright 2017 BSI. All rights reserved.

Research: Ethics, Informed Consent, FDA, Off Label Use

Current Topics in NYS Clinical Laboratory Oversight

GUIDELINES ON MEDICAL DEVICES. IVD GUIDANCE : Research Use Only products A GUIDE FOR MANUFACTURERS AND NOTIFIED BODIES

11.0 FDA-Regulated Research Research Involving Investigational Drugs and Biologics

Regulatory Challenges of Combination Products in EU and US. Afternoon seminar, 24 January 2018 by COBIS and IWA Consulting

OMBU. Ombu Enterprises, LLC Ombu The Operational Excellence Company Ph: Fax: ENTERPRISES, LLC

Niccolo Machiavelli (1523)

Structure and Mandate of FDA

Office for Human Subject Protection. University of Rochester

Points to Consider for Marketing of Computerized Surgical Systems in the U.S.

GENEESS Guideline. Best Practices for Electronics in Medical Devices. V1.3 October 2016

IVD Regulation What you need to know. Erica Conway 5 th May 2017

CANADA (HEALTH CANADA)

ABRIDGED PREQUALIFICATION ASSESSMENT. Prequalification of In Vitro Diagnostics

GUIDANCE NOTE FOR MANUFACTURERS OF CUSTOM-MADE MEDICAL DEVICES

UCI Medical Device Regulatory Awareness - Implications for Start-ups - Copyright 2017 Noblitt & Rueland. Contact Information.

General Comments. May 30, Division of Dockets Management (HFA-305) Food and Drug Administration 5630 Fishers Lane, Room 1061 Rockville, MD 20852

Software Regulation: The Transfusion Medicine Experience

AAMI Quality Systems White Paper

Changes to the Regulation of IVDs in Europe. Copyright 2012 BSI. All rights reserved.

Title: Department: Approved by: Director, Human Research Review and Compliance

DRAFT GUIDANCE. This guidance document is being distributed for comment purposes only. Document issued on: December 27, 2011

Transcription:

An Introduction to the Worldwide Regulatory Framework for Medical Devices Elizabeth Malo M.S., Director, Regulatory Affairs

Course Outline / Agenda» Overview Device Regulatory Framework» US/EU/Canada Premarket Requirements & Submissions Comparison» 510(k) / PMA Detailed Explanation» Introduction to Design Controls» Understanding Clinical Trials» RA / QMS Strategy Development» Question / Answer Session» Additional Items» FDA and Pre Market Clearance Impact EU Medical Device Regulation Dohmen 2017. All rights reserved. May not be copied or distributed. 2

US FDA Medical Device Regulatory Definition» Medical devices range from simple tongue depressors and bedpans to complex programmable pacemakers with micro chip technology and laser surgical devices.» Medical devices include in vitro diagnostic products, such as general purpose lab equipment, reagents, and test kits, which may include monoclonal antibody technology.» Certain electronic radiation emitting products with medical application and claims meet the definition of medical device. Examples include diagnostic ultrasound products, x ray machines and medical lasers. Dohmen 2017. All rights reserved. May not be copied or distributed. 3

US FDA Medical Device Regulatory Definition» If a product is labeled, promoted or used in a manner that meets the following definition in section 201(h) of the Federal Food Drug & Cosmetic (FD&C) Act it will be regulated by the Food and Drug Administration (FDA) as a medical device and is subject to premarketing and postmarketing regulatory controls. A device is:» "an instrument, apparatus, implement, machine, contrivance, implant, in vitro reagent, or other similar or related article, including a component part, or accessory which is: recognized in the official National Formulary, or the United States Pharmacopoeia, or any supplement to them, intended for use in the diagnosis of disease or other conditions, or in the cure, mitigation, treatment, or prevention of disease, in man or other animals, or intended to affect the structure or any function of the body of man or other animals, and which does not achieve its primary intended purposes through chemical action within or on the body of man or other animals and which is not dependent upon being metabolized for the achievement of any of its primary intended purposes." Dohmen 2017. All rights reserved. May not be copied or distributed. 4

Device Classification SIMILAR BUT Not Global» In one country a product might be regulated as drug in another country regulated as a device (example LVP Balanced Intra Ocular Saline Solution (BSS) Drug in the US, CE Marked medical device in Europe» In some countries a product is prescription and in other Over The Counter (OTC) Dohmen 2017. All rights reserved. May not be copied or distributed. 5

Intended Use» The Intended Use of the medical device is the objective intent of the person legally responsible for labeling of a device» Indications for Use of a medical device identify the patient population(s) for which a device can be used, or general or specific conditions a device is intended to treat or diagnose The intended use is the driving force behind medical device classification and often specifies one or more of the following specifications:» Outcome measured (Ex: clearance of blockage by stent)» Purpose for measurement (determine safety and efficacy)» Intended population» Indication for use» Qualitative vs. quantitative clinical endpoints» Testing matrices» Adjunctive or stand alone tests Dohmen 2017. All rights reserved. May not be copied or distributed. 6

Common Global Regulatory Framework Stages» Pre Market Conception and Development Manufacture Packaging and Labeling» Placing on the Market Advertising/Sale» Post Market Surveillance / Vigilance Use Disposal Dohmen 2017. All rights reserved. May not be copied or distributed. 7

US Regulatory Submissions Regulatory Applications for Devices United States 510(k) Substantial Equivalence w/ Predicate(s) Intended Use / Indications for Use Similar Technology Assumed Safety and Effectiveness PMA Proves Safety and Effectiveness No Predicate Requires Animal and Human Trials De Novo Risk & Evidence based Classification Process Low to Moderate Risk Devices Paths: 510(k) with NSE followed by De Novo Application or straight De Novo Request Others 513(g) Request for Classification RFD Request for Designation (combination products) IDE Investigational Device Exemption Dohmen 2017. All rights reserved. May not be copied or distributed. 8

EU & Canada Regulatory Submissions Canada License Application QMS Certification CAN/ ISO 13485:2003 Canadian Registrar Additional CMDCAS Requirements Others Most developed nations have requirements for investigating and marketing medical devices Europe CE Marking Product Approval QMS Approval Compliance with Appropriate Directives (MDD, IVDD, AIMDD) Technical File / Design Dossier ISO 13485 Notified Body Audit Dohmen 2017. All rights reserved. May not be copied or distributed. 9

US vs. the E.U. and Canada Similarities Risk Based Device Categorization Schemas US Class I to Class III EU Class I, Class IIa, Class IIb, Class III Canada Class I to Class IV Premarket Clearance / Approval Required Significance of Process Based on Risk Clinical Data Required for High Risk Devices Quality Management System Required cgmp and ISO 13485:2003 are very similar Post Market Monitoring and Adverse Event Filing Required Audits are performed to verify compliance Clinical Trials Require Pre Approval US IRB + IDE for Significant Risk, IRB only for Non Significant Risk EU Ethics Board + Competent Authority for non CE devices, Ethics Board only for CE devices Canada Ethics Board + ITA for Class II Class IV devices, Ethics Board only for Class I devices Dohmen 2017. All rights reserved. May not be copied or distributed. 10

US vs. the E.U. and Canada Differences Risk Based Device Categorization Schemas Canada and EU use Rules Based approach, not lists of devices and associated classifications (pro codes) Dramatic Differences in resulting Device Classifications (i.e. US Class III could be EU Class I) Premarket Clearance / Approval Required Canada and EU have a single, scalable application type vs. US with two distinct dissimilar applications (tech file and design dossier vs. 510(k) and PMA) Canadian Review done by Governmental Agency EU Review done by Third Party (Notified Body) or Self Declaration US Review done by both FDA and Third Parties ISO 13485 Cert required PRIOR to pre market approval in EU and Canada Dohmen 2017. All rights reserved. May not be copied or distributed. 11

US vs. the E.U. and Canada Differences (Cont.) Quality Management System Required Enforcement of ISO 13485 and QSR are very different FDA acts as a law enforcement agency to gather evidence of non compliance Non compliance with ISO results in CE loss, FDA non compliance can result in civil and criminal penalties Clinical Trials EU All Devices Require Clinical Evaluation Report (Annex X) Allows a combination of Literature Review, Clinical Information, and Clinical Data Class IIb and Class III typically require Clinical Trail Canada Class III and Class IV typically require clinical data US Class III PMA Devices require Clinical Data. Some 510(k) devices require clinical data to support Substantial Equivalence. Dohmen 2017. All rights reserved. May not be copied or distributed. 12

US Premarket Submission Concepts Product Codes Used to Categorize Devices (~1700 Generic Device Types in 16 Medical Specialties) Specifies Device Class / Classifying Regulation TPLC Report GMP Exemptions Submission Type Mandatory Standards Predicate Devices Same Intended Use Same or Similar Technology No Predicate = Automatic Class III Designation Device Classifications Class I Low Risk, General Controls Most 510(k) Exempt Some QSR (cgmp) Exempt Most Design Control Exempt Class II Medium Risk, Special Controls Few 510(k) Exempt None QSR (cgmp) Exempt May Require Human Clinical Data Class III High Risk, Special Controls or PMA Most Require PMA None QSR (cgmp) Exempt None Design Control Exempt All PMAs Require Clinical Data Dohmen 2017. All rights reserved. May not be copied or distributed. 13

Typical US Premarket Submissions PMA Three Flavors Standard PMA Supplement Significant Changes PMA Amendment Amends an unapproved PMA or PMA Supplement Demonstrate Safety and Effectiveness in Class III Devices No Predicate Device Exists Requires Human Clinical Data One or More Pilot Studies Significant Pivotal Study Includes Significant Manufacturing Information Requires Pre Approval Inspection 180 Day Review Target Pre Market Notification 510(k) Three Flavors Traditional Special (Device Modification) Abbreviated (consensus standards & special controls) Substantial Equivalence One or More Predicate Devices Intended Use Comparison Technology and Specification Comparison Technology Differences may drive Bench, Animal or Human Testing to address Human Clinical Data Typically NOT Required 90 Day Review Target Dohmen 2017. All rights reserved. May not be copied or distributed. 14

Traditional 510(k) Submission Required Components» Description of Medical Device Photographs Engineering (CAD) drawings» Proposed Labeling Promotional Materials (Drafts, not Final required)» Identification of Predicate Device(s)» Narrative and tabular comparison to Predicates» Predicate Device(s) Intended use, Indications for Use» Technological Characteristics» Principles of Operation» Software Documentation» Sterility information» Biocompatibility Testing» Statement or Declarations of Conformance (to applicable Standards and FDA Guidance Documents)» Performance testing (bench, animal, clinical) based on Standards. Ex: Risk Assessment (ISO 14971 Standard) Electromagnetic Compatibility and Electrical Safety (ISO 60601 1 Standard)» Administrative requirements Truthfulness and accuracy statement 510(k) summary Payment of User Fee Dohmen 2017. All rights reserved. May not be copied or distributed. 15

De Novo Process The De Novo Process establishes new device type along with classification, regulation, necessary controls and product code where the cleared device is eligible to serve as a predicate for new medical devices, where appropriate [510(k) process] 2 Paths: 1. De Novo Request: devices which do not fall within any classification regulation, where the de novo requester either determines that there is no predicate device (consider pre-sub) 2. Upon NSE determination on a 510(k) submission where no predicate exists with following criteria:» low to moderate risk and should appear, based on what is known about the device, to meet the statutory standards for classification into class I or class II» Sufficient understanding and presentation of Strong risk-benefit analysis and risk mitigation Device effectiveness through general and/or special controls Dohmen 2017. All rights reserved. May not be copied or distributed. 16

FDA Pre Submission Program & Q Subs» Pre Submissions» Informational Meetings» Study Risk Determinations» Early Collaboration Meetings» Submission Issue Meetings» PMA Day 100 Meetings 510(k) summaries, decision summaries, or summaries of safety and effectiveness (SSEDs) for similar legally marketed devices, may be helpful resources, and are available on FDA websites. Dohmen 2017. All rights reserved. May not be copied or distributed. 17

Design Control Overview 21 CFR 820.30 Design Control Requires a SYSTEM including policies and procedures intended to control the product development process Applies to Nearly All Medical Device Except: Some Class I Devices (US / EU / Canada) Some Class IIa Devices (EU) Intended to Provide Structure to the Development Process to Ensure Outputs meet Input Requirements Provides Documentation to Support Pre Market Submission 510(k) / PMA Technical File / Design Dossier License Applications Etc. Is Not Intended to be Executed Retrospectively Dohmen 2017. All rights reserved. May not be copied or distributed. 18

Design Control Overview (cont.) Required Elements Design and Development Planning Design Input Design Output Design Output Design Review Design Verification Design Validation Risk Analysis Software Validation Design Transfer Design Changes Design History File Other Elements for Consideration Control of Design and Development Subcontractors and Consultants Software Lifecycle Configuration Management Bug Tracking System Configuration Management Equipment Maintenance and Calibration Document Controls Test Method Validation Purchasing of R&D Materials Dohmen 2017. All rights reserved. May not be copied or distributed. 19

Process Overview (Industry View) Dohmen 2017. All rights reserved. May not be copied or distributed. 20

Clinical Trials Overview» Approvals to Conduct Human Clinical Studies US / EU / Canada» All require Institutional Review Board (IRB) / Ethics Board / Ethics Committee Approval PRIOR to Study Initiation» In MOST cases IRB, EB, or EC may determine the necessity for other Regulatory Involvement (FDA, Competent Authority)» High Risk Studies / High Risk Devices generally require direct regulatory body involvement via an Application Process» Requirements in the EU vary Country by Country Other Countries» Nearly ALL First and Second World Countries Require some type of Approval to Initiate Human Clinical Studies» Clinical Studies MAY be discoverable by Regulatory Authorities regardless of where conducted (e.g. Truthful and Accurate Statement) Dohmen 2017. All rights reserved. May not be copied or distributed. 21

Clinical Trials Overview (cont.) Things To Know about FDA and Device Trials OUS Studies MAY be acceptable to Support a 510(k) or PMA BUT; Use the Pre IDE Process BEFORE Initiating the OUS Trial Choose a Country whose Demographics and Clinical Practices are comparable to the US (Canada / EU most readily accepted) Pre IDE Process Non Binding on FDA Helps Understanding of FDA Expectations Is NOT generally a Pre Submission Meeting but.. Establishes Company s willingness to Work with FDA Don t Ignore what FDA tells you! Don t Assume a US Trial is Non Significant Risk without confirmation from FDA Reliance solely on IRB can bring unpleasant surprises More 510(k) Devices are likely to require significant Clinical Data Dohmen 2017. All rights reserved. May not be copied or distributed. 22

Regulatory / QA Strategy Overview What Is A Regulatory Strategy? A Path for Regulatory Clearance / Approval in a Market Understanding of the Requirements to Obtain Clearance or Approval Application Type Requirements for Bench Testing Requirements for Animal Testing Requirements for Human Testing Quality Management System Requirements Quality Management System Certifications Understanding the Sequence of Events and Timing Understanding the Integration of Business and Regulatory Activities Understanding of Expected Regulatory / QMS Costs Dohmen 2017. All rights reserved. May not be copied or distributed. 23

Regulatory / QA Strategy Overview How Do I Know If My Current Strategy Is Good Enough? Your Strategy Should Answer All Of The Following: Where will the product be distributed in the first 36 months after launch? What Regulatory Applications will be required in each country? Which applications require clinical or animal data? If Clinical Data is required, where will trials be conducted and what applications / approvals are required for the clinical trial? How long is the average review time for my application type and product type in each country? Are there fees associated with the Regulatory Application? For each application, what is the likelihood of approval / clearance and what are the risk areas? Do any of the applications require corresponding QMS inspections / certifications (pre-approval inspection, ISO certification, etc.)? Do Design Controls apply to my product and if so, how will I meet these requirements? Where the finished product will be manufactured? Dohmen 2017. All rights reserved. May not be copied or distributed. 24

RA/QA Strategies and Valuation Potential Investors Becoming More and More Educated About Medical Products Understand that the Regulatory Strategy, along with IP Protection and Re-imbursement Strategy are key to Medical Device Company Success Often Require both QA and RA due diligence by an expert prior to large round investing Potential Acquirers Large US Device Companies Have a history of QA / RA problems w/ Acquisitions Massive Cost Product Liability Problems with FDA Are looking for easily integratable QA / RA systems w/o major risk Want QMS systems designed to comply with US cgmp requirements Don t want RA surprises (i.e. poor submissions, off-label-use, etc.) Dohmen 2017. All rights reserved. May not be copied or distributed. 25

Additional Items

Current Events in FDA Device Regulations

510(k) Process Challenges» More Burdensome Additional Information Process More Questions Requests for More Detail NSE Decisions Based on Lack of Performance Data» Longer Total Review Times» More Influence by Medical Officers and Clinical Reviewers» Process can be Unpredictable Device Bench Testing Requirements Need for Animal or Human Data Changing of Requirements Mid- Process» Increase in Data Requirements Biocompatibility Verification and Validation Animal and Clinical» More Scrutiny of Predicates Dohmen 2017. All rights reserved. May not be copied or distributed. 28

FDA A List for Final Guidances in 2017» Postmarket Management of Cybersecurity in Medical Devices» Medical Device Accessories: Describing Accessories and Classification Pathway for New Accessory Types» Design Considerations and Pre market Submission Recommendations for Interoperable Medical Devices» Factors to Consider When Making Benefit Risk Determinations for Medical Device Investigational Device Exemptions» Suggested Format for Developing and Responding to Deficiencies» Benefit Risk Factors to Consider When Determining Substantial Equivalence in Premarket Notifications [510(k)] with Different Technological Characteristics» Use of Standards in FDA Regulatory Oversight of Next Generation Sequencing (NGS) Based In Vitro Diagnostics (IVDs) Used for Diagnosing Germline Diseases» Use of Public Human Genetic Variant Databases to Support Clinical Validity for Next Generation Sequencing (NGS) Based In Vitro Diagnostics» Infectious Disease Next Generation Sequencing Based Diagnostic Devices: Microbial Identification and Detection of Antimicrobial Resistance and Virulence Markers» Use of Real World Evidence to Support Regulatory Decision Making for Medical Devices510(k) Third Party Review Program» New or revised procedural guidances for MDUFA IV implementation Dohmen 2017. All rights reserved. May not be copied or distributed. 29

CDRH 2016 2017 Strategic Priorities Establish a National Evaluation System for medical devices» Increase access to and use of real world evidence to support regulatory decision making Thus far, gained access to more than 28 million electronic patient records (from national and international clinical registries, claims data, and EHRs) with device identification using a variety of mechanisms, such as cooperative agreements and access through regulatory process. Partner with patients» Promote a culture of meaningful patient engagement by facilitating CDRH interaction with patients» Increase use and transparency of patient input in regulatory decision making Identify/define the various pre and post market regulatory uses of patient reported outcome measures (PROMs) and issue a report summarizing current PROM regulatory usage patterns and gaps. Work with members of the medical device ecosystem to develop a framework for patient input to inform clinical study design and conduct, with a goal of reducing barriers to patient participation and facilitating recruitment and retention. Promote a culture of quality and organizational excellence» Strengthen FDA s culture of quality within CDRH In FY 2016, CDRH tripled the number of staff with quality credentials by providing on site quality training and certification examinations.» Strengthen product and manufacturing quality within the med device ecosystem Dohmen 2017. All rights reserved. May not be copied or distributed. 30

Medical Device Webinars & Workshops Webinars» Regulatory Overview for Developers and Sponsors of Neurological Devices: An Introduction to the De Novo Pathway» Factors to Consider When Making Benefit Risk Determinations for Medical Device Investigational Device Exemptions Final Guidance» Final Guidance on Medical Device Accessories: Describing Accessories and Classification Pathway for New Accessory Types Public Workshops» The Role of Hospitals in Modernizing Evidence Generation for Device Evaluation: Harnessing the Digital Revolution for Surveillance» CDRH Veteran Amputee Device Workshop» Refurbishing, Reconditioning, Rebuilding, Remarketing, Remanufacturing, and Servicing of Medical Devices Performed by Third Party Entities and Original Equipment Manufacturers» Controlling the Progression of Myopia: Contact Lenses and Future Medical Devices» Adapting Regulatory Oversight of Next Generation Sequencing Based Tests Dohmen 2017. All rights reserved. May not be copied or distributed. 31

EU Medical Device Regulations Current Events

EU s new Medical Device Regulations EU Graphics borrowed from BSI Medical Devices Regulation Update Dohmen 2017. All rights reserved. May not be copied or distributed. 33

Key Changes from MDD to MDR Dohmen 2017. All rights reserved. May not be copied or distributed. 34

Key Changes (cont.) Dohmen 2017. All rights reserved. May not be copied or distributed. 35

Changes in Medical Device Classification Rules Dohmen 2017. All rights reserved. May not be copied or distributed. 36

Classification & Conformity Assessment Regulation Dohmen 2017. All rights reserved. May not be copied or distributed. 37

MDR CE Marking on a Single Slide Dohmen 2017. All rights reserved. May not be copied or distributed. 38

Contact Information Eliza Malo, M.S. RA Director, Regulatory Affairs Dohmen Life Science Services 11925 W. I 70 Frontage Rd. North, Suite 900 Wheat Ridge, CO 80033 eliza.malo@dlss.com http://www.dlss.com/ Phone: 303 952 7267 Cell: 520 334 0959 Dohmen 2017. All rights reserved. May not be copied or distributed. 39