SUPERIOR PRODUCTS INTERNATIONAL II, INC.

Similar documents
Superior Products International II, Inc. VTEC LABS certified penetration of 18 layers of existing lead-based paint

Innovative Coatings Technologies

Eagle Coatings provides a unique array of durable, problem solving coatings for industry and commercial needs.

Rust Grip. Seal off corrosion with a coating made for any environment. Distributor: Venergy Group, LLC

SUPERIOR PRODUCTS INTERNATIONAL LEAD-BASED PAINT ABATEMENT ENCAPSULATION METHOD THAT ELIMINATES SANDBLASTING FOR STEEL STRUCTURES

GULF COAST PAINT MFG., INC

CORLAR 2.1 ST SATIN HIGH SOLIDS EPOXY MASTIC (formerly Corlar 25P )

POLYTHANE CP-500 SERIES

SECTION High Performance Coatings Field Applied Acrylic Urethanes (Solid Color, Pearl and Metallic Finishes)

Tnemec Fluid Applied Thermal Break Long Form Specification

80648R StoColor Acryl Plus Acrylic-Based, Vertical Above-Grade Exterior Wall Coating for Recoating Prepared, Previously Painted Surfaces

80201R StoColor Acryl Flat Acrylic-Based, Vertical Above-Grade Exterior Wall Coating for Recoating Prepared, Previously Painted Surfaces

SECTION BARRIER COAT FIREPROOFING. Display hidden notes to specifier. (Don't know how? Click Here)

80648R StoCoat Acryl Plus Acrylic-Based, Vertical Above-Grade Exterior Wall Coating for Recoating Prepared, Previously Painted Surfaces

Vapor-Clear. The high-performance, low-cost, eco-friendly, aesthetically-pleasing alternative to high-build epoxy floors and boring

TT-P-1757B Type I, Class C, Aerosol Zinc Chromate Primer. A one component, alkyd base, corrosion inhibiting zinc chromate primer.

80212R StoColor Lastic Acrylic-Based, Elastomeric Vertical Above-Grade Exterior Wall Coating for Recoating Prepared, Previously Painted Surfaces

Standard Specification for Non-Reinforced Liquid Coating Encapsulation Products for Leaded Paint in Buildings 1

SECTION Arisfor WallGuard

Corlar 2.1 PR-P High Solids Productive Epoxy Primer

Unmatched Liquid Coating Performance! Specify the Best! Liquid Storage Potable Water Wastewater Fire Protection Industrial Liquids

BAYBLOCK HT/BAYBLOCK HT BASE

Section COATING RESTORATION

Refer to Substrates & Surface Preparation.

TECHNICAL DATA SHEET HYDROPOX #4 QD 1:1 EPOXY WATERWHITE CLEAR

DUR-A-FLEX, Inc. Page 1 of 5

PAINTS AND ENAMELS. Package the paint in new containers marked with the following information:

Steel Panel Frame. Exterior Steel Sheeting. Optional Rigid Insulation. Optional Steel Insulation Liner

Carboguard 890 PRODUCT DATA SHEET SELECTION & SPECIFICATION DATA. Generic Type. Cycloaliphatic Amine Epoxy

80657R StoColor Texture Fine Textured Acrylic-Based, Vertical Above-Grade Exterior Wall Coating for Recoating Prepared, Previously Painted Surfaces

80657R StoColor Texture Fine Textured Acrylic-Based, Vertical Above-Grade Exterior Wall Coating for Recoating Prepared, Previously Painted Surfaces

05030 METAL FINISHES/09800 SPECIAL COATINGS ZRC COLD GALVANIZING COMPOUND

Imron 1.5 PR Waterborne Polyurethane Primer

80648 StoColor Acryl Plus Acrylic-Based, Vertical Above-Grade Exterior Wall Coating for New Concrete, Stucco, and Masonry Construction

1/16 Single Broadcast Polymer Flooring System

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method F (30 C) calculated VOC-US/Hong Kong

Laboratory Testing of Three Above Ground Paint Systems for Canadian Applications

05030 METAL FINISHES/09800 SPECIAL COATINGS COLD GALVANIZING COMPOUND

TECHNICAL DATA SHEET HYDROPOX #2 4:1 EPOXY (MPI #115)

Unmatched Coating Performance! DRY BULK STORAGE

SILICONE ROOF COATING RESTORATION (RCR) SYSTEM OVER METAL ROOF PANEL

Section COATING RESTORATION

POLYURETHANE COATINGS ON STEEL OR DUCTILE IRON PIPE

ADVANTAGES OF SUPER THERM

In accordance with documents prepared by: The Worcester Housing Authority.

Corlar 2.1 PR-P High Solids Productive Epoxy Primer For Use With FG-040, FG-041 or FG-042 Activators

Elastocoat Protective Coatings APPLICATION GUIDE

RENEW ELASTOMERIC ACRYLIC COATING (PAINT GRADE) MANUFACTURERS SPECIFICATION / SECTION

introducing the most complete and durable protective coating system for the heavy industry

Thermal Spray Coating

Ganicin 2.8 ZR-E Zinc-Rich Epoxy Primer

StreetBondSR Specification Help

Florock Seamless Flooring Systems

Florock Seamless Flooring Systems

One-component, heat-resistant silicone acrylic topcoat primarily for the PPG HI-TEMP 1027 primer or the PPG HI-TEMP 222 G primer

PPG HI-TEMP 1000 VS. PRODUCT DATA SHEET December 10, 2014 (Revision of June 30, 2014) DESCRIPTION

SECTION REFLECTIVE-FACED, MASONRY CAVITY WALL INSULATION

1.4 kg/l (11.4 lb/us gal) Maximum 295 g/kg (Directive 1999/13/EC, SED) Maximum 420 g/l (3.5 lb/gal) 50 to 63 μm (2.0 to 2.

A. This Section includes traffic coatings for the following applications:

Testing Results for SUPER THERM Coating After 1000, 2000, and 5000 Hours of Exposure in Ultraviolet and Salt-Spray Chambers

80230 StoColor Coat Sand Acrylic-Based, Vertical Above-Grade Exterior Wall Coating for New Concrete, Stucco, and Masonry Construction

Ganicin 2.8 ZR- U Zinc-Rich Polyurethane Primer

PPG HI-TEMP 1000 V (AMERCOAT 873) PRODUCT DATA SHEET December 10, 2014 (Revision of June 30, 2014) DESCRIPTION

Technical Data Sheet EpoGlass PU Code: 65

Refer to Substrates & Surface Preparation.

Florock Seamless Flooring Systems

Florock Seamless Flooring Systems

1.4 kg/l (11.4 lb/us gal) Maximum 272 g/kg (Directive 1999/13/EC, SED) Maximum 420 g/l (3.5 lb/gal) To 650 C (1200 F) To 538 C (1000 F)

One component, heat-resistant, universal silicone topcoat for use in elevated temperature systems. Replaces HI-TEMP 1000 V / VS / VHA

APPLICATION GUIDELINE FOR

SECTION COMMERCIAL CURB-MOUNT ACRYLIC DOUBLE DOME SKYLIGHTS

How Passive Fire Protection (PFP) Works

1/8 DECORATIVE BROADCAST FLOORING SYSTEM

FOR STEEL POTABLE WATER TANKS INTERIOR AND EXTERIOR CORROSION PROTECTION. Hydro-Zinc

Pacific Polymers Elasto-Deck 5000MR Guide Specification

TECHNICAL REQUIREMENTS AND SPECIFICATIONS. PROTECTIVE COATING OF STEEL (As Provided by Raven Lining Systems) FOREWORD

Section Page 2 Specification No. PG F

EVOCOAT HYBRID

SECTION INSULATED METAL ROOF PANELS. ATAS International, Inc. General Specification for Commercial/Industrial and Architectural Applications

SC-113 STRONGCOTE VEHICULAR GRADE TRAFFIC DECK MEMBRANE SYSTEM SECTION 07570

SPECIAL SPECIFICATION. Transparent Noise Barrier Panels

Florock Seamless Flooring Systems

Bridge Preservation Product Advantages:

Zinc Silicate (Inorganic)

SECTION A. American Society for Testing and Materials (ASTM):

Property Test/Standard Description. US EPA method 24 (tested) (CARB(SCM)2007, SCAQMD rule 1113, Hong Kong)

Protective Coatings for Steel and Concrete Bridge Components

Photo: Anette Ask /Armed Forces. Naval Coatings Guide

Rust-Oleum Industrial Brands Specification

SIGMAZINC 160. Revision of March 2007 DESCRIPTION. two component moisture curing inorganic zinc (ethyl) silicate primer PRINCIPAL CHARACTERISTICS

CeRam-Kote Products by Freecom, Inc.

Florock Seamless Flooring Systems

MAKE ROOFS LAST LONGER

TECHNICAL INFORMATION. 331 and PENNCOAT 340 LINING INSTALLATION. CES /01 Supersedes 04/00 PAGE 1 of 7 1. SURFACE PREPARATION. 1.

SECTION SELF-ADHERING SHEET WATERPROOFING

80201 StoColor Acryl Flat Acrylic-Based, Vertical Above-Grade Exterior Wall Coating for New Concrete, Stucco, and Masonry Construction

STRONGCOTE SC-111 PEDESTRIAN GRADE TRAFFIC DECK COATING SYSTEM SECTION 07570

Corlar 2.8 HG High Solids Epoxy

Innovative Coatings and Linings Technology for Rail Cars. Vijay Datta MS, International Paint LLC and Mike O Donoghue, PhD

Frank D. Rea Director of Coatings Services / Chief Chemist

Transcription:

SUPERIOR PRODUCTS INTERNATIONAL II, INC. RUST GRIP Patent #5,695,812 Method for Abating Bio-Hazardous Materials Found in Coating Such as Lead Based Paint RUST GRIP was developed in the field to stand up against the harshest environments and has a twelve-year history of excellent performance. RUST GRIP is a moisture cure polyurethane coating with special additives and resins. It is these additives and resins that separate RUST GRIP from the thousands of other moisture cure urethanes on the market today. Specifically, what are these advantages? ONE-COAT SYSTEM RUST GRIP was designed as a one-coat system. It serves as both a primer and topcoat. Most urethanes are part of a three coat system and individually don t have the wicking ability to serve as a primer or the overall strength to serve as a stand-alone coating. LIMITED SURFACE PREPARATION RUST GRIP was designed with special resins and additives that allow it to be applied directly over existing firmly bonded paint or rust without any loss of performance. Urethanes in a three-part system normally require surface preparation of a white metal blast (SSPC SP-5) or a near white metal blast (SSPC SP-10). Since the greatest expense in the coating process comes from surface preparation and the containment of that residue, RUST GRIP will greatly reduce the overall cost of a project. ENCAPSULATION RUST GRIP is patented (patent # 5,695,812) as an encapsulant of bio-hazardous materials including lead based paints and rust. I know of no other urethane coating that has a similar patent. RUST GRIP has passed ASTM E1795, which is the EPA test for encapsulation. One of the requirements is that the coating last for twenty years or more. The ability to encapsulate allows RUST GRIP to go directly over lead based paint without removal or exotic containment. This is a major savings in projects involving lead based paint. SURFACE TENSILE STRENGTH After twenty-one days, RUST GRIP will achieve a surface tensile strength of 6,780 psi and over 12,000 psi when fully cured. Normal urethanes will have a surface tensile strength of between 1,000 and 2,000 psi. A BETTER ALTERNATIVE TO THE TRADITIONAL THREE-COAT SYSTEM FOR STEEL AND OTHER STRUCTURES Encapsulates Lead Based Paint One Coat System No Sandblasting Cost-Effective 10835 W. 78 th Street Shawnee, Kansas 66214 Phone: 913-962-4848; Fax: 913-962-6767 Website: www.spicoatings.com Email: sales@spicoatings.com

Characteristics: * Silver gray in color * Aluminum metallic base * Moisture-cure polyurethane * Dries to touch in 2 hours * Recoat window: 4 hours at 70ºF and up to 14 days * 50% solid by weight * Currently used to encapsulate lead-based paint * 51.37% solid by volume Testing Performed: Patent for encapsulating bio-hazardous materials (asbestos, lead-based paint, and many hazardous materials) and existing rust surfaces. Patent #5,695,812. Patented 12/09/97. Performed a window-cycling test on a lead-based wood window and casing, wherein Rust Grip was coated over the wooden window and sliding sill. The window was attached to a motorized opener, which opened and closed the window over 20,000 cycles. The coating rubbed against itself during these cycles, which would be the equivalent of opening and closing a window once a day for 54 years. After the test was stopped, a wipe was made of the abrasion surfaces and checked for released lead-based particles. Even after 20,000 cycles of abrasion, the surface of Rust Grip did not wear down and, no lead-based particles were released into the environment. ASTM E84-89 Surface Burn Test was performed and Rust Grip passed the fire test with 0 flame spread and a 5 smoke development. ASTM E1795 Test was performed on Rust Grip and was passed. This test outlined a Standard Specification for a Non-Reinforced Liquid Coating Encapsulation Products for Leaded Paint in Buildings, Type III, either Interior or Exterior use. This is the EPA Certification test to qualify this coating for encapsulation. ASTM E1795 Exterior Surface Tensile Strength: Minimum 6,870 ASTM 3273, 3274 Mildew Resistance: 10=Excellent ASTM D2486 Scrub Resistance: 2,500 minutes plus=excellent ASTM 3359 Adhesion Test: 5A=Excellent ASTM D522 Mandrel Bend Test for flexibility was passed ASTM D2794 Direct Impact Resistance Test was passed ASTM D1653 Water Vapor Transmission was passed Weathering Test (2,000 hours) was passed Penetration of existing oil-based layers: Rust Grip penetrated through 18 existing coats of oil-based paint and could not be removed or lifted from the substrate under the layers USDA (United States Dept of Agriculture) approval for use in and around food preparation and service Certifications: o o o o o o EPA Encapsulant Approved US Coast Guard Approval ABS (American Bureau of Shipping) Approved IMO (International Marine Organization) Approved DNV (DetNorske Veritas) Approved USDA Approved Page 2 of 12

Traditional Three-Coat System Versus Rust Grip s One Coat System 500,000 SQ. FT. BRIDGE (OVER WATER) WITH LEAD BASED PAINT DESCRIPTION THREE-COAT SYSTEM RUST GRIP Surface Preparation (Including containment and disposal of lead based paint) SSPC, SP-6 OR SP-10 $8.00 - $10.00/sq.ft. SSPC, SP-2 OR SP-3 Encapsulation @ $2.00-$3.00/sq.ft. Coating Cost Ten Mils DFT @ $0.78/sq.ft. Four Mils DFT @ $0.75/sq.ft. Application Costs ($0.25 - $0.40/sq.ft.) Three Coats @ $0.90/sq.ft. One Coat @ $0.35/sq.ft. Traffic Control $0.30/sq.ft. $0.20/sq.ft. Clean-up $0.10/sq.ft. $0.10/sq.ft. TOTAL COST PER SQ.FT. $11.08 $3.90 TOTAL DOLLAR COST $5,540,000 $1,995,000 500,000 SQ. FT. BRIDGE (NOT OVER WATER) WITH LEAD BASED PAINT DESCRIPTION THREE-COAT SYSTEM RUST GRIP Surface Preparation (Including containment and disposal of lead based paint) SSPC, SP-6 or SP-10 $6.00 - $8.00/sq.ft. SSPC, SP-2 or SP-3 Encapsulation @ $1.50-$2.50/sq.ft. Coating Costs Ten Mils DFT @ $0.78/sq.ft. Four Mils DFT @ $0.75./sq.ft. Application Costs ($.25 - $.40/sq.ft.) Three Coats @ $0.90/sq.ft. One Coat @ $0.35/sq.ft. Traffic Control $0.30/sq.ft. $0.20/sq.ft. Clean-up $0.10/sq.ft. $0.10/sq.ft. TOTAL COST PER SQ.FT. $9.08 $3.40 TOTAL DOLLAR COST $4,540,000 $1,700,000 500,000 SQ. FT. BRIDGE (OVER WATER) WITH NO LEAD BASED PAINT DESCRIPTION THREE-COAT SYSTEM RUST GRIP Surface Preparation (Including containment and disposal of lead based paint) SSPC, SP-6 OR SP-10 $6.00 - $8.00/sq.ft. SSPC, SP-2 OR SP-3 Encapsulation @ $1.50-$2.50/sq.ft. Coating Cost Ten Mils DFT @ $0.78/sq.ft. Four Mils DFT @ $0.75/sq.ft. Application Costs ($.25 - $.40/sq.ft.) Three Coats @ $0.90/sq.ft. One Coat @ $0.35/sq.ft. Traffic Control $0.30/sq.ft. $0.20/sq.ft. Clean-up $0.10/sq.ft. $0.10/sq.ft. TOTAL COST PER SQ.FT. $9.08 $3.40 TOTAL DOLLAR COST $4,540,000 $1,700,000 500,000 SQ. FT. BRIDGE (NOT OVER WATER) WITH NO LEAD BASED PAINT DESCRIPTION THREE-COAT SYSTEM RUST GRIP Surface Preparation (Including containment and disposal of lead based paint) SSPC, SP-6 or SP-10 $5.00 - $7.00/sq.ft. SSPC, SP-2 or SP-3 Encapsulation @ $1.00-$2.00/sq.ft. Coating Costs Ten Mils DFT @ $0.78/sq.ft. Four Mils DFT @ $0.75./sq.ft. Application Costs ($.25 - $.40/sq.ft. Three Coats @ $0.90/sq.ft. One Coat @ $0.35/sq.ft. Traffic Control $0.30/sq.ft. $0.20/sq.ft. Clean-up $0.10/sq.ft. $0.10/sq.ft. TOTAL COST PER SQ.FT. $8.08 $2.90 TOTAL DOLLAR COST $4,030,000 $1,450,000 Page 3 of 12

Test Listings for Rust Grip ASTM TESTING: B 117 15,000 Hour Salt Spray (Fog) - Salt Spray Fog Testing - RUST GRIP over Steel D-257-99 D 522 D 610 D 714 D 1654 DG 20-88 D 3359 D 4060 D 4541 D 6904 D 7088 E-108-00 E 903-96 E 1795 D-C Resistance of Insulating Materials - Surface Resistivity = 5.237E+15 - Volume Resistivity = 5.263E+15 Mandrel Bend - Penetration through 18 layers of Lead Base Paint - Rated 5A = Excellent Percentage of surface rusted = rating 9 No blistering = rating 10 No loss of adhesion = rating 10 Chemical resistance = excellent Adhesion and Penetration - Penetration through 18 layers of Lead Base Paint - Rated 5A = Excellent Tabor Abrasion Resistance - 1000 Cycles with a CS 17 Wheel, 1000 gram Load - 18 milligram loss per 1000 Cycles, rated Excellent Standard Method for Pull-0ff Strength - Pull-Off Strength = 1467 Resistance to Wind-Driven Rain for Exterior Coatings Applied to Masonry Resistance to Hydrostatic Pressure for Coatings Used in Below Grade Applications Applied to Masonry Spread of Flame Tests on Pitched Roofs - Class A Non-combustible Spectral Reflectance - Average of 3 Tests = 44.6% Solar Reflectance 55.5% Solar Absorption Encapsulation of Leaded Paint in Buildings - Direct Impact Resistance (ASTM D 2794) - Adhesion (ASTM D 3359, D 4541) - Dry Abrasion Resistance (ASTM D 4060) - Water Vapor Transmission (ASTM D 1653) - Flexibility Mandrel Bend (ASTM D 522) - Distilled Water Resistance Immersion 24 hours -.010 Tinplated Steel (ASTM D 1308, D 3359) - ¼ Steel or Aluminum (ASTM D 1308, D 4541) - Chemical Resistance 24 Hours- 12 Reagents - Spot Test on Glass (ASTM D 1308) - Surface Burning Characteristics (E 84) - Volatile Organic Content (VOC) - (ASTM D 2369, D 4017, D 3960, D 1475) - Weathering (1000 hours) - Aging (interior and exterior) - Scrub Resistance (ASTM D 2486) - Black Plastic No Break thru after 12 cycles) - Mildew Resistance (ASTM D 3273, 3274) - Paint / Repair Ability (ASTM D 3359) - Tensile Properties (6780psi after 3 weeks) - Visco-Elastic Properties (ASTM D 2370) ASTM TESTING CONTINUED F 963 Compliance with maximum soluble limits of - Antimony, arsenic, barium, cadmium, chromium - Lead, mercury, and selenium G 20 Chemical Exposure - 5% Ammonia - 5% Urea - 1500 Hour Salt Fog G 85 Prohesion (Louisiana DOT) - 1500 Hour Salt Fog - Rated 9 (out of a possible 10 rating) Testing for ABS (American Bureau of Shipping), IMO (International Maritime Organization) and U.S. Coast Guard Approval. IMO A 653 (16) Flame Spread [A 653 (16) MSC 41 Smoke Toxicity - ASTM B117, D163, D522, D3359, & E1795 Rame-Hart Static Contact Angle (Young s Equation): Static contact angle of Rust Grip is lower than water demonstrating that Rust Grip has exceptional wettability, adhesiveness, and high solid surface free energy for greater penetration into the substrate. China Center for Technical Testing: National Measurement M0729 GB/T 1771-91 - Resistance to Salt Fog (2000 hours) GB/T 1866-88 - Manuel Aging (2000 hours) GB/T 10834-88 - Resistance to Salt Water (1000 hours) GB/T 5219-85 - Adhesion (pulling apart method) Window Recycling Test for Encapsulation of Lead Based Paint:. Testing was done for encapsulating existing lead based paint on windows for HUD - Window coated with RUST GRIP. - Coated surface showed no wear, friction burn, or leadbased paint exposure - Window was cycled a total of 29,700 times before test concluded. Maximum Temperature Exposure Test: Thermal analysis testing was performed on RUST GRIP to determine maximum temperature exposure during application and operation -Maximum temperature is 600 degrees F (315 degrees C) Complete Test Results Are Available Upon Request Page 4 of 12

Certifications and Registrations for Rust Grip 1. AMERICAN BUREAU OF SHIPPING Passed SOLAS 1974 (as amended) requirements for paints/finish materials Requiring compliance with Parts 2 (Smoke & Toxicity) and 5 (Surface Flammability) of the IMO FTP Code, Res. MSC.61 (67) U.S. Type Approval Certificate No. SL520997-X E.C. Type Approval Certificate No. 04-HS 458158-EC U.S. Coast Guard Product Approval No.: 164.112/0729/458158 2. USDA (UNITED STATES DEPARTMENT OF AGRICULTURE) USDA Approved Letter of Authorization from USDA Product Safety Branch Letter of Written Certification as Accepted by USDA from Manufacturer 3. FACTORY MUTUAL APPROVAL Tested and Approved for Metal Roofing 4. LOUISIANA DEPARTMENT OF TRANSPORTATION Approved for Use on Qualified Products List Passed Salt Fog Test for 1500 hours 5. MISSISSIPPI DEPARTMENT OF TRANSPORTATION Approved for Use on Qualified Products List 6. TENNESSEE DEPARTMENT OF TRANSPORTATION Acceptable for encapsulation of galvanized guardrail 7. UNIVERSITY OF KENTUCKY Acceptable for encapsulation of steel bridges for Kentucky Department of Highways 8. SAUDI ARABIAN OIL COMPANY Tested and approved by Saudi Aramco for encapsulation of bio hazardous materials Page 5 of 12

Huey P. Long Bridge New Orleans, Louisiana November 2003 A pull test done in February 2005 demonstrated Rust Grip s ability to penetrate into the substrate. The result of a pull test on panel not coated with Rust Grip was 200 psi. Then two pull tests were done on a panel coated with Rust Grip and the results on one panel was 540 psi and the other panel was 580 psi. Page 6 of 12

Louisiana Bridge at Exit 8 Vinton Exit, Louisiana April 1, 1996 This Louisiana bridge was coated with Rust Grip, which resulted from the R-9 rating out of a possible R-10 received from the 1500 hour salt fog test. After 9 years, the coating is in excellent condition. Other competing corrosion coatings had previously failed on this bridge. Page 7 of 12

Page 8 of 12 Army Corps of Engineers Danville, Pennsylvania June, 2005

For this project, the rusty surface is power-washed at approximately 3,500 psi and then primed with Rust Grip. NO SANDBLASTING REQUIRED. Blue Chip Casino Michigan City, Indiana April 2005 Bridge Deck Flooring: Power-washed Power-Washed Surface Bow of Boat: Power-Washed Surface Primed with Rust Grip (uncoated area for welding of appendages) Power-Washed Surface Primed with Rust Grip Pilot House: Power-washed Surface Coated with Rust Grip Rust Grip Coated with Super Therm (for insulative protection) Page 9 of 12

For this project involving oil and gas storage tanks, the rusty surface was power-washed and then primed with Rust Grip and topcoated with Enamo Grip Chevron Pacific Indonesia. PT Indonesia May 2008 Before Application Rust Grip Application Enamo Grip (green) Application Completed Project - Rust Grip and Enamo Grip Page 10 of 12

For this project involving oil and gas storage tanks, the rusty surface was power-washed and then primed with Rust Grip and topcoated with Enamo Grip Chevron Pacific Indonesia. PT Indonesia May 2008 Oil Storage Tanks Coated with Rust Grip and Enamo Grip (black) Completed Project - Rust Grip and Enamo Grip (black) Page 11 of 12

Chevron Pacific Indonesia. PT Indonesia May 2008 For this project involving corrosion from condensation on natural gas pipelines, the surface was power-washed and then primed with Moist Metal Grip and topcoated with Enamo Grip Before Application Cleaning of Surfaces Application of Moist Metal Grip Application of Enamo Grip (safety yellow) Page 12 of 12