FRICTION-BASED SLIDING BETWEEN STEEL AND STEEL, STEEL AND CONCRETE, AND WOOD AND STONE

Similar documents
Investigation of the sliding behavior between steel and mortar for seismic applications in structures

EXPRIMENTAL AND ANALYTICAL STUDY ON SEISMIC BEHAVIOR OF TRADITIONAL WOODEN FRAMES CONSIDERING HORIZONTAL DIAPHRAGM DEFORMATION AND COLUMN SLIPPAGE

Research on seismic behavior of Wood-Concrete Hybrid Structure

FULL SCALE STATIC LOADING TESTS FOR TWO STORIED PLANE FRAME OF TRADITIONAL TOWN HOUSE IN KYOTO, JAPAN

VIBRATION RESPONSE CHARACTERISTICS OF ROCKING PILLAR BASE ISOLATION SYSTEM SUITABLE FOR MASONRY HOUSES

DYNAMIC LOADING TEST ON RC FRAME RETROFITTED BY OUTER CES FRAME

COMPARISON OF SEISMIC PERFORMANCE OF BASE-ISOLATED HOUSE WITH VARIOUS DEVICES

Development of Cylindrical Passive Damper using High Damping Rubber

SEISMIC FORCE RESISTING MECHANISM OF THE MULTI-STORY PRECAST CONCRETE SHEAR WALL SUPPORTED ON PILES

Friction Force of Fastener-Typed Frictional Damper Applied to Pre-cast Concrete Curtain Wall

E-DEFENSE EXPERIMENTS ON FULL-SCALE WOODEN HOUSES

THE APPLICATION OF RESPONSE CONTROL DESIGN USING MIDDLE-STORY ISOLATION SYSTEM TO HIGH-RISE BUILDING

SEISMIC DESIGN OF STRUCTURE

SEISMIC PERFORMANCE OF CONCRETE TILT-UP BUILDINGS: CURRENT WALL-TO-SLAB CONNECTIONS

DEVELOPMENT OF ADVANCED FRICTION SLIDING DAMPER

DYNAMIC CHARACTERISTICS ASSESSMENT OF STEEL BEAM-COLUMN CONNECTIONS WITH FLOOR SLAB

Cu-Al-Mn Super-elastic Alloy Bars as Dissipative Brace System in Structural Steel Frame

COMPARISON OF SEISMIC PERFORMANCE OF BASE-ISOLATED HOUSE WITH VARIOUS DEVICES

Application of Isolation Technology in High-voltage Electrical Equipments

SEISMIC BEHAVIOR OF HYBRID SYSTEM WITH CORRUGATED STEEL SHEAR PANEL AND RC FRAME

CHAPTER 4. 1:6-Scale Frame: Stiffness and Modal Testing 4.1 OVERVIEW

EXPERIMENTAL STUDY ON SEISMIC BEHAVIOR OF REINFORCED CONCRETE CORE WALL

INELASTIC SEISMIC RESPONSE ANALYSES OF REINFORCED CONCRETE BRIDGE PIERS WITH THREE-DIMENSIONAL FE ANALYSIS METHOD. Guangfeng Zhang 1, Shigeki Unjoh 2

Seismic Performance and Modeling of Post-Tensioned, Precast Concrete Shear Walls

Literature Review of Wood-frame Structure Tests

Mechanical behavior and design method of weld-free steel structure with knee brace damper using square tube column

1458. A preliminary study on the dynamic friction behavior of a one-third scale-down vertical cylindrical cask

Hybrid Shake Table for the Testing of Midlevel Seismic Isolation Systems

Floating Type Isolation System Using Earthquake Early Warning

Seismic Collapsing Process Analysis of One-story Thatched Roof Wooden Structure under Strong Earthquake Ground Motion

RETROFITTING METHOD OF EXISTING REINFORCED CONCRETE BUILDINGS USING ELASTO-PLASTIC STEEL DAMPERS

Dynamic response of interlocking structures due to harmonic ground motions

Title. Author(s)KANATA, T.; MATSUMURA, M.; NAKANISHI, Y.; YAMAGUCHI, Issue Date Doc URL. Type. Note. File Information STRUCTURES

composite elements, lateral loads, strain analysis, behavior Composite steel concrete elements made by steel and concrete are used in world wide almos

Effect of plastic hinge, soil nonlinearity and uplift on earthquake energy in structures

Effective Length of RC Column with Spandrel Wall

Experimental investigation of the use of CFRP grid for shear strengthening of RC beams

SEISMIC COLLAPSING BEHAVIOUR OF ONE-STORY WOODEN STRUCTURE WITH THATCHED ROOF UNDER STRONG EARTHQUAKE GROUND MOTION

PRECAST PRESTRESSED PORTAL FRAMES WITH CORRUGATED STEEL PANEL DAMPERS

SHAKING TABLE TEST USING MULTIPURPOSE TEST BED

Seismic Damage-Resistant System for Multi-Storey Modular Light Steel Framed Buildings

Osamu Takahashi, Hiromasa Aida 1 Junji Suhara, Ryoichiro Matsumoto 2 Yasuo Tsuyuki 3 Takafumi Fujita 4. Kozo Keikaku Engineering 2

one structural behavior, systems, and design ARCHITECTURAL STRUCTURES: FORM, BEHAVIOR, AND DESIGN DR. ANNE NICHOLS SUMMER 2015 lecture

Page 1 of 46 Exam 1. Exam 1 Past Exam Problems without Solutions NAME: Given Formulae: Law of Cosines: C. Law of Sines:

Seismic Performance Evaluation on Historical Timber Frame Structures with Large Hanging Walls

Development and Realization of Base Isolation System for High-Rise Buildings

Analysis of Lateral Loads for a Framed Model with Tuned Liquid Damper

STUDY ON SHAKING TABLE TESTS OF ISOLATED BRIDGE MODEL WITH LRB

one structural behavior, systems and design Course Description Course Description Syllabus & Student Understandings statics mechanics of materials

Seismic Collapsing Analysis of Two-Story Wooden House, Kyo-machiya, against Strong Earthquake Ground Motion

Tests of R/C Beam-Column Joint with Variant Boundary Conditions and Irregular Details on Anchorage of Beam Bars

Wataru Goto. NTT FACILITIES, INC. in Japan. 15th World Conference on Earthquake Engineering 24 to 28 September 2012 LISBON PORTUGAL

PSEUDO DYNAMIC TESTS AND IMPLEMENTATION OF SLIDING BRIDGE ISOLATORS WITH VERTICAL MOTION

EXPERIMENTAL STUDY OF SEISMIC BEHAVIOR OF SCALED NON-ENGINEERED MASONRY STRUCTURES RETROFITTED BY PP-BAND MESH

Fagà, Bianco, Bolognini, and Nascimbene 3rd fib International Congress

An experimental study of structural plastic hinge development and nonlinear soil deformation

EFFECT OF THE GRID-SHAPED STABILIZED GROUND IMPROVEMENT TO LIQUEFIABLE GROUND

EXPERIMENTAL STUDY ON DYNAMIC BEHAVIOR OF WOODEN FRAMES WITH PASSIVE CONTROL SYSTEM AND INNER-AND-OUTER WALLS USING SHAKING TABLE

Southeast University, Nanjing, Jiangsu , China. *Corresponding author

sixteen seismic design Earthquake Design Earthquake Design Earthquake Design dynamic vs. static loading hazard types hazard types: ground shaking

Frictional Properties of Non-Metallic Materials for Use in Sliding Bearings: An Experimental Study

INELASTIC SEISMIC PERFORMANCE OF RC TALL PIERS WITH HOLLOW SECTION

Seismic Evaluation of the Historic East-Memorial Building Retrofitted with Friction Dampers, Ottawa, Canada

Mechanisms of Bond Failure Between Existing Concrete and Sprayed Polymer Cement Mortar with CFRP Grid by Acoustic Emission

SHEAR OF CONCRETE MASONRY WALLS

Damage Assessment of Reinforced Concrete Columns Under High Axial Loading

Gravity Load Collapse of Reinforced Concrete Columns with Brittle Failure Modes

Research on Seismic Behavior of honeycomb composite beamcolumn

Structural characteristics of column with precast wing walls as energy absorption elements

Integrated Optimal Life Cycle Design of Super Tall Buildings with Viscous Dampers

STRESS CHARACTERISTICS OF PILE GROUP DURING EARTHQUAKE BASED ON CENTRIFUGE LARGE SHEAR BOX SHAKING TABLE TESTS

SEISMIC-FORCE-RESISTING MECHANISMS OF MULTI-STORY STRUCTURAL WALLS SUPPORTED ON PILES ABSTRACT

Experimental Study on the Outrigger Damping System for High-Rise Building

STRUCTURAL PERFORMANCE OF MIXED MEMBER COMPOSED OF STEEL REINFORCED CONCRETE AND REINFORCED CONCRETE

EXPERIMENTAL VALIDATION OF THE STRUCTURAL FUSE CONCEPT

THE DESIGN AND INSTALLATION OF A FIVE-STORY NEW TIMBER BUILDING IN JAPAN

SOFIE Project - Cyclic Tests on Cross-Laminated Wooden Panels

Collapsing Simulation of Wooden House Retrofitted by ACM Braces During Seismic Ground Motion

Dynamic Stability of Elastomeric Bearings at Large Displacement

EXPERIMENTAL INVESTIGATION OF PRECAST CONCRETE BEAM TO COLUMN CONNECTIONS SUBJECTED TO REVERSED CYCLIC LOADS

STUDY ON SEISMIC PERFORMANCE OF LOW EARTHQUAKE RESISTANT MASONRY BUILDINGS RETROFITTED BY PP-BAND MESH

SHEAR BEHAVIOR OF MULTI-STORY RC STRUCTURAL WALLS WITH ECCENTRIC OPENINGS

Seismic Evaluation of a 1930 Steel Bridge with Lightly Reinforced Concrete Piers

Investigation into Crack Phenomena of Unreinforced Concrete Structures for Aseismic Evaluation of Concrete Dams

Assistant Professor, Applied Mechanics Department, Government College of Engineering, Amravati, India 2

Effect of Seismic Reinforcement of Sheet Pile Quay Wall Using Ground Anchor

Pseudo-dynamic Testing of Self-centering Steel Plate Shear Walls

Dynamic Analysis of Large Steel Tanks

BEHAVIOR OF PRECAST CES COLUMNS FOR MIDDLE AND LOW-RISE HOUSES

Basic Characteristics and Durability of Low-Friction Sliding Bearings for Base Isolation

OPTIMUM INSTALLATION OF VISCOUS LIQUID DAMPERS IN HIGH-RISE BUILDINGS

LOW-CYCLE FATIGUE FAILURE MECHANISM OF WIND TURBINE FOUNDATION DUE TO VIBRATION OF UPPER STRUCTURE

BI-DIRECTIONAL PSEUDO-DYNAMIC TEST OF CIRCULAR SECTIONAL CFST BRIDGE PIERS

1554. Influence of friction variability on isolation performance of a rolling-damper isolation system

LATERAL LOAD BEHAVIOR OF UNBONDED POST-TENSIONED HYBRID COUPLED WALLS. Qiang SHEN Graduate Research Assistant. Yahya C. KURAMA Assistant Professor

STRENGTH AND DUCTILITY OF RETROFITTED R/C BUILDING BY MULTI-STORY STEEL-BRACED FRAME SUBJECTED TO TRI-LATERAL EARTHQUAKE LOADING

A seismic reinforcement method for an existing pile foundation in soft ground and liquefiable ground

Seismic damage prediction of old Japanese-style wooden house using predominant period distribution of ground surface layer

Responses of Base-Isolated Buildings in Tokyo during the 2011 Great East Japan Earthquake

A SEICMIC UPGRADING TECHNIQUE FOR TIMBER STRUCURE WITH VISCO-ELASTIC TAPE

Transcription:

FRICTION-BASED SLIDING BETWEEN STEEL AND STEEL, STEEL AND CONCRETE, AND WOOD AND STONE Peng-Cheng Zhang 1, Takuya Nagae 2, Jason McCormick 3, Masahiro Ikenaga 4, Mika Katsuo 4, Masayoshi Nakashima 5 1 Associate Professor, Dept. of Architecture & Civil Engineering, Xiamen University, Xiamen. China 2 Researcher, National Research Institute for Earthquake Science and Disaster Prevention, Hyogo, Japan 3 Assistant Prof., Dept. of Civil and Environmental Engineering, The University of Michigan, Michigan, USA 4 Graduate Student, Dept. of Architecture and Architectural Engineering, Kyoto University, Kyoto. Japan 5 Professor, Disaster Prevention Research Institute, Kyoto University, Kyoto. Japan Email: zpcchina@ yahoo.com.cn ABSTRACT : This paper presents a series of shaking table studies on the friction coefficients between steel and mortar, steel and steel, and wood and stone. The sliding behavior suggests that the characteristics of the materials, such as the hardness and roughness, affect the friction coefficients during sliding motion. For the steel to steel tests, the local material damage changes the contact condition. Plowing of the two surfaces along with heat generated during sliding provided a wide range of friction coefficients. For the steel to mortar tests, the mortar is damaged locally as a result of scraping during the initial sliding, but soon the behavior becomes stable. The friction coefficient is about 0.5 initially and raised to a stable value of about 0.8. Tests of wood columns sitting on a stone base plate exhibit stable friction coefficient of about 0.5, with almost no damage on the base plane. KEYWORDS: Friction coefficient, steel and concrete, steel and steel, wood and stone

1. INTRODUCTION Friction is a form of resistance in connecting elements and members. Applications of friction devices also increase recently particularly in combination with base-isolation and passive damping systems. For base-isolation, friction with low friction coefficients is preferred, all the while in passive damping systems friction with medium to high friction coefficients are often adopted. Although much research has been done in the examination into the friction coefficients for materials used in base-isolation and passive damping systems, the friction characteristics of conventional materials, say, steel versus steel, steel versus concrete, or wood versus stone, have not been explored extensively except for few (Nagae et al 2005). In particular, information on sliding and dynamic friction of such combinations of materials is very limited. These combinations, however, do exist in real applications. In old wood houses such as temples, main wood columns are often placed directly on top of the foundation stone without any physical connection between the wood column and foundation stone. In steel building structures, steel column bases are often supported by concrete and mortar underneath the column base. They are normally connected by anchor bolts, but friction between the steel place and the underneath concrete or mortar is often counted for the horizontal resistance. Metal touch is common in building contents made of steel that are placed on top of steel plank. This paper examines the dynamic friction characteristics, including the friction coefficients corresponding to the initiation of sliding and the changes of the coefficients by repeated sliding. The study is experimental, and shaking table tests are conducted to obtain the necessary information. 2. SHAKING TABLE TEST FOR FRICITON BEHAVIOR OF STEEL AND MORTAR A large-scale shake table study was conducted to determine the fundamental sliding characteristics between steel and mortar and steel and steel under dynamic loads. The six degree of freedom shake table (3 m by 5 m) owned by the Disaster Prevention Research Institute of Kyoto University, Japan, was used. The shake table can provide a maximum acceleration and velocity of 1.0 g and 1.5 m/s in each direction. All shaking was performed in the direction parallel to the long dimension of the shake table. The test specimen used to evaluate the sliding behavior consisted of three main elements: the lower friction surface (either mortar or steel), the upper friction surface (steel), and the rigid mass as shown in Figure 1. The test specimen had four points of contact.

3850 295 250 318 75 400 Mortar Base Plane Concrete Mass Stainless Steel Column Foot 750 1500 750 2000 750 1500 750 2.1 Test for Combination of Steel and Mortar Figure 1 Test specimen used to evaluate the sliding behavior In the tests for the combination of mortar and steel, the mortar surfaces were cast on top of Japanese steel H-Sections (similar to U.S. I-sections) and secured to the H-sections using steel studs. Steel angles attached to the H-section were used to border the mortar surface to provide a stable and immobile block. The H-sections were the only portion of the test specimen which was directly bolted to the shake table. The dimensions of the mortar surface were 550 mm by 1020 mm allowing for approximately 300 mm of sliding in either direction when the steel surface is placed at the center of the mortar surface. Material tests showed that the mortar had compression strength of 35 N/mm 2 at the time of testing. The steel friction elements adopted as the upper friction surface consisted of 250 mm by 250 mm by 60 mm blocks of steel which were tapered on one side down to a 75mm by 75 mm square. This smaller square had a polished surface and represented the contact area with the lower friction surface. The steel friction element was held in place under the load cells and connected to the rigid mass. Vertical and horizontal bolts allowed for adjustment of the slope of the steel friction surface to ensure full contact with the mortar and equal distribution of the gravity load between each of the four points of contact. The rigid mass consisted of a 68.6 kn concrete block sitting on top of a 9.2 kn horizontal steel frame. The concrete mass was connected to the steel frame using PC bars at four points. Combining the weight of the concrete block, steel frame, load cells, and steel friction blocks provided a total specimen weight of 82.0 kn. This overall weight results in a pressure of 14.6 N/mm 2 on the mortar surface at the contact points. Further details and dimensions of the test specimen can be seen in Fig. 1. The test specimen was instrumented with tri-axial load cells to measure both the vertical load at each contact point and the shear force generated by the contact between the steel and mortar. Laser displacement transducers were used to measure the absolute displacements of both the mortar surface and rigid frame while strain potentiometers were used to directly measure the relative sliding between the two. Accelerometers were also installed on the concrete mass and on the surface of the shake table in order to obtain both relative and absolute acceleration values. Sliding occurred from the inertial acceleration rose to 0.5g, and the concrete base plane surfaces were damaged locally by repeated mortar scraped off, as shown in Fig 2. The steel column scrapes into the mortar surface with even obtuse edges, as shown Fig. 3. These changed the contact condition. Accordingly, the friction coefficient, defined as the horizontal shear force divided by the weight, changed, from about 0.5 initially to about 0.8 afteward. It is notable, however, that the coefficient becomes rather stable after a few cycles and for further repeated cycles, the coefficient value remained relative unchanged. Figure 4 shows an example of the friction coefficient time history.

Fig 2 Scraped mortar plane surface Fig 3 Scraped steel plane surface Shear-Axial Ratio vs Displacement for Run (061214_X_1Hz500_Z_1Hz300) 0.6 0.4 Shear Force/Axial Force 0.2 0-180 -160-140 -120-100 -80-60 -40-20 0 20-0.2-0.4-0.6 Relative Displacement (mm) -0.8 2.2 Test for Combination of Steel and Steel Fig 4 Change in friction coefficient with repeated sliding

Two rounds of shaking table test were conducted to determine the sliding characteristics between steel and steel under dynamic loads. The test setup was the same as that used for the tests for the combination of steel and mortar. In the first round, the steel surfaces were polished intestinally. A steel place instead of mortar was placed for the lower friction surface. Sliding occurred from the inertial acceleration rose to 0.15g, but the polished steel base plane surfaces also were damaged locally even more severely by repeated adhesion and prow or wedge formation. Double-sided adhesive wear occurred easily, at interface built-up edge rose the friction coefficient higher and higher, shown in Fig 5. For example, the initial static friction coefficient was 0.15, with this value increasing to 0.6. Fig 5 The adhesion and prow or wedge formation on friction surface between polished steel plates The second round of test was conducted for the combination steel and steel with the black-skin left as it was. Until the black skin was removed locally by reciprocated friction sliding, the coefficient was relatively stable and constant. The thin and stiff black skin was soon penetrated through, and afterward, almost the same phenomena observed as in the polished steel specimen replayed (Fig. 6). On the damaged base plate surface, some adhesion bonding points looked like flamed scar, which showed that the frictional heat was concomitant. Fig 6 Adhesion on friction surface between steel plates left with black-skin 3. SHAKING TABLE TEST FOR FRICITON BEHAVIOR OF WOOD AND STONE Another shaking table study was conducted to determine the fundamental characteristics of a Chinese palace timber frame structure. The columns of the frame were placed on the stone block without tight connection (Fig. 7). The specimen was an exact replica designed and constructed based on YIN ZAO FA SHI, then the national civil engineering code of the Song dynasty of 1011. Following the code, smooth and stiff stone blocks were used as the base plates. The shake table used in the test is owned by the Xi an University of Architecture & Technology, China, with a plan dimension of 2 m by 2.2 m. The shake table can provide a maximum acceleration and velocity of 1.0g and 1.0 m/s in the horizontal direction. The test specimen used to evaluate the sliding behavior consisted of three main elements: the stone base plate surface, the wooden column bottom surface, and the frame as can be seen in Fig. 7. The test specimen had four points of contact where

sliding occurred to roughly simulate four column bases in a building structure. roof mass 250 joist beam 180 Brackets 270 ring beam 75 frame beam wooden column 1500 stone base plate wooden column foot 1400 80 ends of wood fibre stone baseplate Fig 7 Shake table test specimen of Chinese timber frame The scale ratio of specimen was adopted to be 1/3.52, to follow a precise scale with which each member could be made easily using the code. The roof mass consisted of a 36 kn concrete block sitting on top of a 4 kn timber frame. The diameter of the each column was 210 mm, the total weight 40 kn of the superstructure made about 0.29 N/mm 2 average compressive stress at the column bottom. The specimen frame had a natural frequency of 2.44 Hz. The static friction coefficient between the wood column and stone plate was observed to be 0.4 to 0.5 from a previous test. Further details and dimensions of the test specimen are shown in Fig. 7 and reported in Zhang et al (2002).

The specimen was excited by sinusoidal waves having a frequency close to the natural frequency of the specimen. The excitation rose from zero to a value of about 4 m/s 2 in the acceleration amplitude, when the structure sustained significant drifts, and continued for 200 s. The friction behavior between wood and stone was very stable. The tail-end of wood fibers at the bottom of the columns apparently acted as cushions, and this flexible material neither dig nor plowed into the stiff stone. The damage to the stone was nearly none, too. 1000 The Acceleration Conducted by Sympathetic Vibration f=2.44 800 600 Acceleration (gals) 400 200 0 1 20 39 58 77 96 115 134 153 172 191 210 229 248 267 286 305 324 343 362 381 400 419 438 457 476 495-200 -400-600 -800-1000 Time(Sample Frequency=200 ) Exciting Acceleration of Shake Table Responding Inertial Acceleration of the Roof Mass Fig 8 Response of timber frame subjected to sinusoidal input motion Fig 9 Displaced wood column without damage to stone base 4. CONCLUSION Dynamic friction behavior for the combination of conventional materials, i.e., steel versus mortar, steel versus steel, and wood versus stone, was examined by multiple shaking table tests. For the combination of steel and

mortar, the friction coefficient increased in the initial stage of repeated cycles (from about 0.5 to 0.8), but soon (after few cycles) it became stable and remained relatively unchanged for many more succeeding cycles. The initial increase was attributed to the damage to the mortar induced by the counterpart steel. For the combination of steel and steel, the friction coefficient continued to rise from a small value of about 0.15 to nearly 0.6 primarily due to the severe local damage caused by repeated adhesion and prow or wedge formation. The friction coefficient was most stable for the combination of wood and stone, maintaining a constant value of 0.5 for many repeated cycles. REFERENCES Nagae, T., Ikenaga, M., Nakashima, M., and Suita, K. (2005) Shear Friction between Base Plate and Mortar in Exposed Steel Column Base. Trans. of AIJ Journal of Structural and Construction Engineering, 606(8), 217-223. (in Japanese) ZHANG peng-cheng ZHAO hong-tie XUE jian-yang GAO da-feng(2002) Shaking Table Test on Building Models of Chinese Ancient Timber Structure WORLD EARTHQUAKE ENGINEERING 2002.4,35-41(in Chinese)