NOVEL CYCLES FOR POWER AND REFRIGERATION

Similar documents
Thermodynamic Modeling of Binary Cycles Looking for Best Case Scenarios

Customized Absorption Heat Pumps for Utilization of Low-Grade Heat Sources

ABSORPTION/RESORPTION REFRIGERATION SYSTEMS WORKING WITH AMMONIA/WATER MIXTURES: MODELLING AND PERFORMANCE

Second Law of Thermodynamics

SOLAR COOLING: STATE OF THE ART, TECHNICAL ANALYSIS AND FIRSTS APPLICATIONS

Innovative Systems for Solar Air Conditioning of Buildings

Module 05 Lecture 35 : Low temperature process design Key words: Refrigeration system

Investigation of Separator Parameters in Kalina Cycle Systems

Revue des Energies Renouvelables Spécial ICT3-MENA Bou Ismail (2015) Numerical study of a single effect ejector-absorption cooling system

Eng Thermodynamics I: Sample Final Exam Questions 1

2 nd Law of Thermodynamics

Eng Thermodynamics I - Examples 1

Problems in chapter 9 CB Thermodynamics

THE SECOND LAW OF THERMODYNAMICS

Solar cooling plants: how to arrange solar collectors, absorption chillers and the load

Evaluation of the Impact of Off-Design Operation on an Air-Cooled Binary Power Plant. G. L. Mines. September 22, 2002 September 25, 2002

Theoretical analysis of an integrated thermoelectric-absorption cooling system

Project 3: Analysis of diverse heat recovery Steam Cycles Artoni Alessandro Bortolotti Alberto Cordisco Giuliano

GEOFAR : Innovative geothermal technologies Last modifications: BINARY PLANTS

DESIGN OF VAPOUR ABSORPTION REFRIGERATION SYSTEM OF 1.5TR CAPACITY BY WASTE HEAT RECOVERY PROCESS

Solutions to TUTORIAL-6 (10/03/2017) Thermodynamics for Aerospace Engineers (AS1300) Second Law of Thermodynamics

Organic Rankine Cycle Configurations

Eng Thermodynamics I - Examples 1

Modelling of an adsorption chiller with Modelica

Permanent City Research Online URL:

Thermoeconomic evaluation of combined heat and power generation for geothermal applications

GEOTHERMAL SPACE COOLING

THE CHOICE OF WORKING FLUID: (AND AN EFFICIENT TURBINE) Ennio Macchi Department of Energy - Politecnico di Milano

Research on Heat Conversion Systems for Power and Refrigeration

COMPARATIVE ANALYSES OF TWO IMPROVED CO 2 COMBINED COOLING, HEATING, AND POWER SYSTEMS DRIVEN BY SOLAR ENERGY

UNIT NO-03 [8 hrs] Second Law Of Thermodynamics: Introduction (Law of degradation of energy), Thermal energy reservoirs, Kelvin-Plank & Clausius

Chapter 10 POWER CYCLES. Department of Mechanical Engineering

Cool Producing Systems Based on Burning and Gasification of Biomass

Integration of Kalina Cycle in a Combined Heat and Power Plant, A Case Study

Parametric Study of a Double Effect Absorption Refrigeration System

Design and Optimization of Kalina Cycle for Geothermal Energy in Kenya

Solar Absorption Aqua-Ammonia Absorption system simulation base on Climate of Malaysia

Low temperature cogeneration using waste heat from research reactor as a source for heat pump

A Study Regarding the Performances of Trigeneration Systems

Chapter 6 THE SECOND LAW OF THERMODYNAMICS

Available online at Energy Procedia 4 (2011) Energy Procedia 00 (2010) GHGT-10

Lubrication-installation of screw engine applied in an Organic Rankine Cycle

Low Emissions gas turbine solutions

Refrigeration Cycle. Definitions , , 11-46, 11-49,

An assessment of renewable energy generation in a conventional steam power plant with geothermal feedwater preheating

HPC 2017 Performance simulation and exergy analysis on multi-stage compression high temperature heat pumps with R1234ze(Z) refrigerant

Evaluating the Potential of a Process Site for Waste Heat Recovery

A NOVEL APPLICATION OF A SCREW ROTOR ENGINE AS AN EXPANSION DEVICE IN AN ORGANIC RANKINE CYCLE

SIMULATION OF A THERMODYNAMIC CYCLE WITH ORGANIC ABSORBENTS AND CO 2 AS WORKING FLUID

Chapter 6 THE SECOND LAW OF THERMODYNAMICS

Chapter 8. Vapor Power Systems

Thermodynamic Analysis of Combined Power and Cooling Cycle Using Process Heat from a Passout Turbine as a Heating Source

Solar Powered Vapour Absorption Refrigeration (SPVAR) System as a rural microenterprise

LECTURE-15. Ideal Reverse Brayton Cycle. Figure (6) Schematic of a closed reverse Brayton cycle

High efficient heat reclaim with CO2

Combined Heat and Power

1. To improve heat exchange between a gas & a liquid stream in a heat exchanger, it is decided to use fins. Correct the suitable option.

Modeling and analyzing solar cooling systems in Polysun

- 2 - SME Q1. (a) Briefly explain how the following methods used in a gas-turbine power plant increase the thermal efficiency:

Comparative Efficiency of Geothermal Vapor-Turbine Cycles

Lecture No.1. Vapour Power Cycles

POLYGENERATION: TECHNOLOGIES & POSSIBILITIES. Prof.Emeritus S.Srinivasa Murthy Refrigeration & Clean Energy Technologies

OPTIMIZING THE GENERATOR AND ABSORBER THERMAL LOAD OF COMBINED ABSORPTION-EJECTOR REFRIGERATION SYSTEM

Design, modelling, performance optimization and experimentation of a reversible HP/ORC prototype.

Thermodynamic Modelling of a Vapor Absorption Cogeneration Cycle

MODELING THERMODYNAMIC ANALYSIS AND SIMULATION OF ORGANIC RANKINE CYCLE USING GEOTHERMAL ENERGY AS HEAT SOURCE

Exergy Analysis of a Ground-Source Heat Pump System. University of Cambridge, Department of Engineering, Cambridge, UK, 2

Recent U. S. R&D results from IEA HPP Annex 41

II. SYSTEM DESCRIPTION AND MATHEMATICAL MODELING

Improvement of distillation column efficiency by integration with organic Rankine power generation cycle. Introduction

Low-Grade Waste Heat Recovery for Power Production using an Absorption-Rankine Cycle

Dimensioning a small-sized PTC solar field for heating and cooling of a hotel in Almería (Spain)

Comparison of combined heat and power systems using an organic Rankine cycle and a low-temperature heat source

CO 2 Transcritical Cycle for Ground Source Heat Pump

W t. Strategy: We need to step through the equipments and figure out the inlets and outlets to allow us to calculate the work and heat terms.

HIGH EFFICIENCY POLYGENERATION APPLICATIONS (HEGEL) I,II

New Suggestions for Centrifugal Chiller Technologies to Realize High Efficiency and High Functionality

MAE 119 Professor G.R. Tynan Winter 2018 Homework 4. Assigned 6 Februrary 2018 Due 19 February 2018

System cost and efficiency optimization by heat exchanger performance simulations

A Scroll Expander with Heating Structure and Their Systems

Control strategies study of a complete solar assisted air conditioning system in an office building using TRNSYS.

Chapter 6. The Second Law of Thermodynamics. by Asst. Prof. Dr.Woranee Paengjuntuek and Asst. Prof. Dr.Worarattana Pattaraprakorn

COEFFICIENT OF PERFORMANCE OF TWO PHASE CONDENSING EJECTOR REFRIGERATION SYSTEM WITH R-22

Solar Cooling Technologies for Southern Climates - A System Comparison

Radial Turbine Preliminary Design and Modelling

Energy and Exergy Analysis of Combined Ejector-Absorption Refrigeration System

Second Law Analysis of a Carbon Dioxide Transcritical Power System in Low-grade Heat Source Recovery

Mathematical Modeling of Basic Parts of Heating Systems with Alternative Power Sources

31.3 GEOTHERMAL CYCLES

THEORETICAL STUDY AND DEVELOPMENT OF ABSORPTION CHILLERS WITH ENHANCED AUXILIARY WASTE HEAT RECOVERY

THE ALL-IN-ONE INLET AIR COOLING AND FILTRATION SOLUTION USING YOUR WASTE HEAT FREUDENBERG FILTRATION TECHNOLOGIES

Chapter 5: Thermodynamic Processes and Cycles

Introduction to Aerospace Propulsion. Prof. Bhaskar Roy. Prof. A. M. Pradeep. Department of Aerospace Engineering

Application of Exergy Analysis. Value and Limitations

Guidance page for practical work electricity production from geothermal energy

Application of Industrial Heat Pumps

Guidance page for practical work 5: OTEC closed and open cycle

DEVELOPMENT OF A GAS-FIRED DOMESTIC HEAT PUMP

Supersonic Nozzle Flow in the Two-Phase Ejector as Water Refrigeration System by Using Waste Heat

Design considerations for integration of two 5 MW vapour compression heat pumps in the Greater Copenhagen district heating system

Transcription:

st European Conference on Polygeneration NOVEL CYCLES FOR POWER AND REFRIGERATION Felix Ziegler Technische Universität Berlin, Institute of Energy Engineering Secr. KT, Marchstraße 8, D-587 Berlin, Germany felix.ziegler@tu-berlin.de ABSTRACT It is well known that cold can be produced from heat using sorption cooling cycles. It is also well known that low-grade heat can be converted into power also, although the efficiency is low. Considering the fact that both for producing power and cold sorption cycles may be used both conversion processes can be combined and a cogeneration of power and cold from heat can be envisaged. In this paper, the basic features and some cycle configurations with the potential of being feasible will be discussed, although practical experience is still lacking. The main obstacles for widespread use are the high cost for heat exchange, which defines a large research need. Also control may play an important part. INTRODUCTION Low temperature heat sources are abundant. Especially the industrial waste heat is attractive due to the fact that its disposal itself bears expenses because of investment for and operating of the necessary cooling equipment. It is interesting to note that the way of using low temperature heat is quite different, depending on its origin. Typically, for industrial waste heat, upgrading or production of cooling is discussed. In the case of geothermal heat, the conversion to electricity is very prominent today. This paper is supposed to combine these options, and it should demonstrate some development options for the future. Novel cycles for power and refrigeration 69

Tarragona (Spain), 6-7 October 7 We start off with some considerations about efficiency of individual production of cold and power from low-temperature heat sources. We continue with combining the production. Finally, we discuss some technical solutions. EFFICIENCY OF SEPARATE PRODUCTION Heat Driven Chillers Let us have a look at an absorption chiller in the conventional black-box manner (Figure a). It is characterised by the temperatures of the heat sink (environment) T and the respective heat flow,, the heat source (produced cold ) T, and the driving heat temperature T and heat flow,. The well-known cooling COP / results to: COP T T T ( T T T g [] ( ) ) Here, the thermodynamic quality g is the ratio between the real efficiency COP and the thermodynamic limit; it accounts for irreversibilities due to fluid restrictions (staging etc.) or design of the equipment. Let us now assume that the low temperature heat source exhibits a relatively large glide with temperature of the flow (in) and return (out), T i and T o (Figure b). We can still use equation [] if we substitute for T the thermodynamic mean temperature of the heat source, Ť, which is defined for constant heat capacities by: T Ti To lnt lnt i o [] 7 F. Ziegler (Technische Universität Berlin)

st European Conference on Polygeneration T T i T o T T T a) T b) Figure : Black-box representation of an absorption chiller; small (a) and large (b) glide in the heat source (supply T i, return T o );heat sink temperature (cooling water) T ; production of cold at T. The thermodynamic mean is reasonably near to the arithmetic mean (Ziegler, 998). We find immediately equation [3] which is displayed in Figure : T T T T T T T ( T T COP T T T i T o T o T T T i i i i i o ln g g [3] ( ) ( ) T ),5 C COP c C,75,5 8 C supply temperature T i,5 4 6 8 return temperature T o [ C] Figure. Coefficient of performance COP of a heat driven chiller according to equation [3] in dependence of the return temperature T o of the driving heat source. Parameter: Supply temperature T i of the driving heat source. heat sink temperature 3 C, driving temperature difference in the heat exchangers 5K, cold production at T 9 C, thermodynamic quality of the process g.7. Novel cycles for power and refrigeration 7

Tarragona (Spain), 6-7 October 7 Please note that in this Figure irreversibilities both for external heat exchange and internal features are contained. It is interesting to see that even with relatively low return temperatures acceptable COPs can be attained. The prerequisite, of course, is the availability of adapted machinery. In our equation, we assume that for any external temperature we can find an adequate cycle with only decent irreversibilities. This normally is not the case. Here we are only interested in the potential limits. Power Plants Let us now look at thermal power plants. If we use the well-known Carnotefficiency with the mean input temperature according to [] we find equation [4], which is displayed in Figure 3. It is obvious that the efficiencies are quite low in comparison with fossil fired plants, and even in comparison with the efficiency of a heat driven chiller. T T T ln T T g T i T T i T ( Ti T T ) g i o η [4] i o o i 7 F. Ziegler (Technische Universität Berlin)

st European Conference on Polygeneration η,5, C C supply temperature T i 8 C,5 4 6 8 return temperature T o [ C] Figure 3: Efficiency η of the power station according to equation [4] in dependence of the return temperature T o of the driving heat source. Parameter: Supply temperature T i of the driving heatsource. heat sink temperature 3 C, driving temperature difference in the heat exchangers 5K, thermodynamic quality of the process g.7. COMPARISON If we compare equation [3] to [4] we see that - even for real machines in order to calculate the COP for cooling under comparable circumstances (temperature of driving heat source and heat sink, quality) the power station efficiency η has to be multiplied by the coefficient of performance T /(T - T ) of a reversible compression chiller working between T and T : COP T T T η [5] ( ) The ratio T /(T - T ) typically is in the order of. The thermal efficiency of producing cold, therefore, is about one order of magnitude higher than the one of power plants. That means that from a given low temperature heat source - ten times more cooling energy than electrical energy can be produced. Novel cycles for power and refrigeration 73

Tarragona (Spain), 6-7 October 7 EFFICIENCY OF COMBINED PRODUCTION Basics The scheme of a combined cycle producing power and cold from a heat source with gliding temperature is displayed in Figure 4: we just have to add the power output, P. i Figure 4: Black-box representation of an absorption chiller according to Figure,but producing power P also The driving heat input,, is now the energy which is required to drive both the cooling and the power producing process. In order to describe the performance we need two different, independent numbers because we have two different outputs. These may be chosen from the electrical efficiency, P/, the cooling efficiency, /, and the power-to-cold ratio, P/. We find: P T ln T T i T o T T T + T i o g [6] P T T i ln T i T o T o T T + T P g [7] 74 F. Ziegler (Technische Universität Berlin)

st European Conference on Polygeneration With using the equations [3] and [4] we can write also: + COP T T T [8] P P + η T T T P [9],5 P/ /,75 P/.,5,5 P/ 4 6 8 return temperature T o [ C] supply temperature T i C Figure 5: Performance characteristic / according to equation [6] in dependence of the return temperature T o of the heat source. Parameter: ratio of power to cold, P/ supply temperature T i C. Heat sink temperature 3 C, cold production at T 9 C, driving temperature difference in the heat exchangers 5K, thermodynamic quality of the process g.7. Both equations are displayed in Figures 5 and 6. The ratio of cold production (heat flow ) to power output P or vice versa is used as a parameter. The uppermost curves in both cases denotes the case where merely cold and no power is produced (Figure 5) or vice versa (Figure 6). It is obvious - and also easily understandable from basic thermodynamics - that the cold output of the system responds much stronger to an increase in power output (Figure 5) than the power output responds to an increase in cold output (Figure 6). As a consequence we can Novel cycles for power and refrigeration 75

Tarragona (Spain), 6-7 October 7 immediately conclude that the co-production of cold in a power station will have only very little effect on the primary energy need of the system, whereas the coproduction of power from an absorption chiller will have significant consequences. P/,5, /P /P.5 /P,5 4 6 8 return temperature T o [ C] supply temperature T i C Figure 6: Performance characteristic P/ according to equation [7] in dependence of the return temperature T o of the heat source. Parameter: ratio of cold to power, /P supply temperature T i C heat sink temperature 3 C, cold production at T 9 C, driving temperature difference in the heat exchangers 5K, thermodynamic quality of the process g.7. Performance chart We can also combine equations [6] and [7] to give us the driving input heat flow which is required for a given output of cold,, and power, P: P T T + T T T i ln T i T o T o g P + T T T η [] Normalising, and using COP from [3] and η from [4] as parameters we arrive at the simple relationship: 76 F. Ziegler (Technische Universität Berlin)

st European Conference on Polygeneration P / / + η COP [] This relationship is displayed in Figure 7. It may be used as a performance chart of the cogeneration process because it gives the interdependence of taking both products from one heat source in a very simple way. As a parameter the return temperature of the driving heat source was chosen.,5 /,5 T o C T o 8 C,5,,5 P / Figure 7: Performance chart: / depending on P/ according to equation []. Parameter: return temperature T o of the heat source. supply temperature T i C heat sink temperature 3 C, cold production at T 9 C, driving temperature difference in the heat exchangers 5K, thermodynamic quality of the process g.7. The coefficient of power reduction with cold production, ß, gives us the change in power output, when the output of cold is increased at given driving heat input: ß P T T T [] The change in cold output, when the output of power is increased at given driving heat input is the reverse: Novel cycles for power and refrigeration 77

Tarragona (Spain), 6-7 October 7 P T T T [3] Cycle configurations By looking at the technology which is available today we note that in thermal cooling as well as low-temperature power plants sorption processes play a major role. There are some consequences: the know-how in absorption cooling technology has to be spread to the power plant engineers; the absorption cooling community should look over the fence and consider power plants. Finally, and this is our goal here, taking into account that absorption refrigerators and, e.g., Kalina cycles (Leibowitz et al., 999, Köhler, 5) make use of the same fluids, we can design new cycles combining the production of cold and power (Figure 8). T Figure 8: Graph of combined cooling-power plants in the pressure temperature plot. Heat input or output is indicated by vertical arrows;work output is indicated by horizontal arrows. The right hand cycle can be looked at as a Kalina-cycle to which a singleeffect chiller has been added. The left hand cycle is more complicated. It is a superposition of a Kalina-cycle and a double-effect absorption chiller. This cycle is especially valid if the temperature glide in the heat source is large. It needs, of course, more components and control. The right hand cycle is a quite simple one. Another somewhat simpler configuration of the left cycle of Figure 8 is displayed in Figure 9 in the form of a flow scheme. 78 F. Ziegler (Technische Universität Berlin)

st European Conference on Polygeneration G LWT W EM K EV EV LEV K/G LWT LP LEV V A Figure 9: Flow scheme of a double-effect absorption cooling-power plant, producing cold and power P from waste heat A: Absorber; EM: Exp. machine; EV: Exp. valve; G: Generator; K: Condenser; LEV: Solution valve; LWT: Solution hx; V: Evaporator This cycle, again, features a double-effect absorption chiller in which a turbine has been inserted in parallel to the throttling devices, i.e. between high and low pressure, or Generator G and Absorber A, respectively. The cycle is almost the same as in Figure 8 left, with only the heat exchange being different. However, the amount of power which can be produced is less in this cycle configuration. The performance chart of the cycle analogously to Figure 7 is plotted in Figure. For a heat input of MW the production of Cold can be almost. MW (pure chiller), whereas the power will be less than kw (pure sorption power cycle). Most Novel cycles for power and refrigeration 79

Tarragona (Spain), 6-7 October 7 important is the freedom to adjust the ratio between cold production and power production. Cold output / MW,5 Heat input MW,5 Heat input.5 MW,5, Work output / MW Figure : Performance chart of the cycle from Figure 9 CONCLUSION We have discussed the separate and combined production of cold and mechanical power from low-temperature heat sources. Before these combined cycles become mature technologies many technological obstacles mainly originating from the expanders have to be overcome. Research in this field has just started. We should note, moreover, that all low-grade heat technologies chillers and heat transformers as well as some power cycles (sorption power cycles, Kalina) may make use of sorption technology. So, disregarding which kind of energy service we want to procure, sorption cycles will play a major role. This should be enough reason for enhancing basic research in this field. As the largest fraction of cost is born by the heat exchangers, especially the area of heat transfer has to be promoted. 8 F. Ziegler (Technische Universität Berlin)

st European Conference on Polygeneration REFERENCES. Köhler, S. (5) Geothermisch angetriebene Dampfkraftprozesse - Analyse und Prozessvergleich binärer Kraftwerke. Dissertation Thesis at Technische Universität Berlin; 5.. Leibowitz HM, Mlcak HA (999) Design of a MW Kalina Cycle Binary Module for Installation in Husavik, Iceland In: Proceedings of Geothermal Resources Council Annual Meeting October 7-, 999, Reno, Nevada, p. 75-8. 3. Ziegler, F (998) Relationships between temperature differences in heat exchangers of heat transformation devices. Revue Générale du Thermique, Vol.37, 998, pp.549-555. Novel cycles for power and refrigeration 8