AFM-Raman Characterization of Pharmaceutical Tablets

Similar documents
Characterization of Materials with a Combined AFM/Raman Microscope

Application Note. Raman Spectroscopy Analysis of Crystalline Polymorphs for Pharmaceutical Development

Supplementary material 1: DNA tracing

Raman Spectroscopy and Photoluminescence Mapping. of Diamonds with Multiple Fluorescence Zones

A Study of the Formation Modes of Nanosized Oxide Structures of Gallium Arsenide by Local Anodic Oxidation

A Study of the Formation Modes of Nanosized Oxide Structures of Gallium Arsenide by Local Anodic Oxidation

Application Note. Introduction. Analysis of crystal polymorphism by Raman Spectroscopy for Medicine Development

Scanning Probe Microscopes

Carbon Black At-line Characterization. Using a Portable Raman Spectrometer

Laser Raman Spectrometer

Raman Spectroscopy for Pharmaceutical Applications

Magnetic Force Microscopy: nanoscale magnetic imaging and lithography

If you were sick, say with cancer, would you not want a drug that has a way

Microstructural Characterization of Materials

ASPECTS REGARDING THE QUALITY OF SURFACES OBTAINED BY USING THE SELECTIVE LASER SINTERING TECHNOLOGY

Evaluation of Mechanical Properties of Hard Coatings

Supplementary Information. The substrate matters in the Raman spectroscopy analysis of cells

Advantage of handheld Raman spectrometer with 1064 nm excitation in pharmaceutical raw material identification

Satoshi Kawata. Near-Field Optic s and Surface Plasmon Polaritons

The Raman effect, discovered in 1928 by C.V. Raman in his

NanoTA2 Sub-100nm Local Thermal Imaging and Analysis

The Scanning Kelvin Probe Technique for Assessing Coating Degradation

Near-field. Raman microscopy by Neil Anderson *, Achim Hartschuh, and Lukas Novotny

Repetition: Adhesion Mechanisms

Nano Wear Testing Polymer Coated Glass

Electronic Supplementary Information

Material Identification Through Packages using 1064nm Excitation Raman Spectroscopy

Raman mapping to identify dry and wet states of pharmaceutical components in a hydroxypropyl methylcellulose (HPMC) hydrophilic matrix tablet

Examination of Analytical Conditions for Trace Elements Based on the Detection Limit of EPMA (WDS)

In situ semi-quantitative assessment of single cell viability by resonance

CONTENTS. Introduction. NSOM Optical Fiber Probes

Sub-micron scale patterning of fluorescent. silver nanoclusters using low-power laser

Chapter 3: Powders Production and Characterization

Confocal Raman microscopy for noncontact and nondestructive characterization of carbon fibers

OPTIMIZING XRD DATA. By: Matthew Rayner

Department of Chemistry, Center for Photochemical Sciences, Bowling Green State University,

Application of the interference method of studying the surface for quality control and internal structure of the luminescent crystals and

Advanced Materials Technology Key Expertise Theme. astutewales.com

Study on Estimation Methods of Applied Stress using Fractography Analysis

Global Journal of Engineering Science and Research Management

Supporting Information

Phys. Low-Dim. Struct. 3/4, 223 (2001). Surface modifications of sapphire single crystals and PET polymer induced by swift heavy ions.

Laser Processing and Characterisation of 3D Diamond Detectors

Skills and excellence formation on basis of Laboratory of Plasma Physics & Atomic Spectroscopy Institute of Spectroscopy (ISAN) of Russian Academy of

CHAPTER 5. HIGH PRESSURE MICRO RAMAN STUDIES ON SINGLE CRYSTAL Yb 2 O 3

Feature Article. Non-Destructive Evaluation of SiC wafer for Power Device Defect detection in μm~nm scale using optical analytical technique

NV High Brightness Series

Giant Gap-Plasmon Tip-Enhanced Raman Scattering of MoS 2 Monolayers on Au Nanocluster Arrays

Crystallographic Characterization of GaN Nanowires by Raman Spectral Image Mapping

Tip-enhanced Raman spectroscopic detection of aptamers

ARC RECIPROCATING WEAR AT HIGH TEMPERATURE

Carbon Nanotube Material Quality Assessment

SUPPLEMENTARY INFORMATION

Shaped Femtosecond Laser Pulse Spectroscopy for Nuclear Forensics. Phyllis Ko ANS Student Conference 2011

CORROSION SURFACE ANALYSIS USING 3D PROFILOMETRY

Supporting Information. Two-Photon Luminescence of Single Colloidal Gold NanoRods: Revealing the Origin of Plasmon Relaxation in Small Nanocrystals

Title: Localized surface plasmon resonance of metal nanodot and nanowire arrays studied by far-field and near-field optical microscopy

SUPPLEMENTARY INFORMATION

Synthesis and Characterization of Cadmium Sulfide Nanoparticles

Combined fluorescence and AFM imaging of cells

EFFECT OF LOCAL PLASTIC STRETCH OM TOTAL FATIGUE LIFE EVALUATION

Supplementary Information. Capacity fade in high energy silicon-graphite electrodes for lithium-ion batteries

A New Deep UV Raman & Photoluminescence Spectrometer System. The DUV Raman/PL 200 by Photon Systems, Inc.

Preparation and properties of PTFE anti-friction coating

R. L. Aggarwal, L. W. Farrar, S. Di Cecca, and T. H. Jeys. MIT Lincoln Laboratory, Lexington, MA

CHAPTER 5 EFFECT OF POST DEPOSITION ANNEALING ON THE SURFACE MORPHOLOGY OF THE DLC FILM

B&W IRUG Mobile Spectroscopy Solutions. Copyright 2016 B&W Tek.

Production of Few-Layer Phosphorene by Liquid Exfoliation of Black Phosphorus

Imperfections, Defects and Diffusion

Ionscope SICM. About Ionscope. Scanning Ion Conductance Microscopy. Ionscope A brand of OpenIOLabs Limited

In the Proceedings of the Second Asia-Pacific Workshop on Near-field Optics, Beijing, China, October 20-23, 1999.

Study the Structure, Morphology and Vibration Modes for K 2 CrO 4 and K 2 Cr 2 O 7

Page 1 of 5

Building, 75 Montrose Street, G1 1XQ, Glasgow 3 Strathclyde Institute of Pharmacy & Biomedical Science (SIPBS), University of Strathclyde, 161

Application of Atomic Force Microscopy (AFM) in Polymer Materials

Fabrication and application of high quality diamond coated. CMP pad conditioners

Investigation of high voltage induced damage of GaN grown on Si substrate by terahertz nano-imaging and spectroscopy 1.

Microscope Analysis for the Study of the Ageing Processes of Solid Oxide Fuel Cells Fueled by Blends of Hydrogen and Natural Gas.

Femtosecond micromachining in polymers

Fracture. Brittle vs. Ductile Fracture Ductile materials more plastic deformation and energy absorption (toughness) before fracture.

Cluster Ion Imaging of the Paris Meteorite

Micro and nano structuring of carbon based materials for micro injection moulding and hot embossing

Diamond Coated Wire Cutting of Solar Si Ingots: New Insights Using Raman Microspectroscopy

Preliminary Investigation of Near Infrared Spectroscopy for Green Sand Component Identification

Chapter Outline: Failure

The strategy. using Atomic Force Microscope; Biomolecules and Neutraceuticals examples

Surface Roughness Investigations on Nb Samples using Optical Profilometry

Noncontact Photo-Acoustic Defect Detection in Drug Tablets

Fs- Using Ultrafast Lasers to Add New Functionality to Glass

Tribological Characterization of Ti-WS2 Coating

Supporting Information for

ECE 541/ME 541 Microelectronic Fabrication Techniques

Observation in the GB (Gentle Beam) Capabilities

FT-IR. varian, inc. 660/670/680-IR.

Particle characterization of Metal Powders with Dynamic Image Analysis

Tablet Coating Failure Using Micro Scratch Testing

CONFOCAL SPECTROMICROSCOPY OF AMORPHOUS AND NANOCRYSTALLINE TUNGSTEN OXIDE FILMS

HYPERSPECTRAL MICROSCOPE PLATFORM FOR HIGHLY MULTIPLEX BIOLOGICAL IMAGING. Marc Verhaegen

Hysitron TI 980 TriboIndenter. Innovation with Integrity. Tribology and Mechanical Testing

Hysitron TI 980 TriboIndenter. Innovation with Integrity. Tribology and Mechanical Testing

Transcription:

AFM-Raman Characterization of Pharmaceutical Tablets Compound Distribution Studies in Pharmaceutical Tablets by Integrated AFM-Raman Instrument 1,2 1 Sergey Shashkov and Pavel Dorozhkin, 1 NT-MDT Co., Zelenograd, Russia 2 QuantumDesign Japan, Tokyo Raman microscopy is a widely used technique in pharmaceutical industry [1]. It allows identifying and rapidly characterizing chemical compounds, functional groups, molecular conformers, and authenticating various drugs. It is also useful in revealing the presence of impurities and structural disorder in materials, studying stress distributions, and temperature effects. Integration of Raman spectroscopy with Atomic Force Microscopy (AFM) opens a wide range of new capabilities in imaging and characterizing pharmaceutical products. For example, a) AFM topographic imaging provides information on the size of grains, their shape, orientation and distribution. In addition, advanced AFM techniques also allow high resolution imaging of various physical properties of micro-scale objects: local hardness, friction coefficient, electrical conductivity, surface potential and many others. In this application note an integrated AFM Raman instrument is used for a comprehensive study of a representative pharmaceutical tablet to demonstrate the capabilities of the technique. Sample scanning direction b) Fig. 1. (a) Integrated AFM-Raman instrument and its focus track featur e. Sample surface always stays in focus due to AFM feedback mechanism. This provides true information about sample chemical composition even for very rough surfaces. ( b ) Standard confocal Raman/fluorescence imaging sample is scanned in X&Y directions; Sample gets out of focus, providing incorrect data about optical properties of the surface. http:///device/ntegra-spectra

The working p rinciple of the AFM Raman setup is shown in Fig. 1a. Anatomic force microscope is integrated with a high resolution objective lens in a top-illumination geometry. The objective is connected to a confocal Raman/fluorescence microscope. The optical part of the setup is used to focus the excitation laser to a very small spot at the apex of the AFM cantilever and to collect the optical signal from a local area on the sample in the confocal regime. Raman scattering, fluorescence, Rayleigh scattering and other optical signals can be measured. Cantilevers with an elephant-trunk shape are used to avoid obstruction of laser light by the cantilever. While the sample is scanned (in X, Y& Zdirections), AFM and optical images are obtained simultaneously from exactly the same sample area. Alternatively, Raman and AFM images (from the same sample area) can be obtained independently. In this case, the Raman image is obtained in a standard configuration without the presence of an AFM cantilever (Fig. 1b). More details of the AFM-Raman instrument operation can be found in [ 2]. ne of the important advantages of simultaneous AFM-Raman mapping is the possibility to image very rough surfaces which is important, for example, when pharmaceutical tablets are studied. The connoted focus track capability of the integrated AFM-Raman instrument is demonstrated in Fig. 1 ab,. When a rough sample is scanned in a standard mapping regime (X&Y sample movement only), the surface of the sample comes in and out of focus of the objective while sample is moving (Fig. 1b). This results artifacts in the confocal Raman imaging that may lead to erroneous interpretation of the data. For example, observed variations of Raman signal intensity can be due only to the sample topography (surface coming in and out of focus) ; not to changes in the chemical composition of the surface. In the focus track regime the AFM cantilever is placed under the objective (Fig. 1 a) and the excitation laser is focused on the apex of the cantilever ( within the optical resolution of the lens). When the sample is scanned, the AFM feedback mechanism adjusts the sample height to keep it in controlled contact with the AFM cantilever. This guaranties that surface of the sample always stays precisely in the laser spot focus. Thus, the optical signal is always obtained exactly from the sample surface, independent of the sample roughness. Therefore, when focus track is used, all variations of the Raman signal are from the sample composition and not from topographic roughness. H Aspirin CH 3 H N Paracetamol CH 3 H Fig. 2. Raman spectra on the ANADIN Tablet: Aspirin (green color), Paracetamol (red color). http:///device/ntegra-spectra

As a pharmaceutical sample, an ANADIN EXTRA tablet (Pfizer Consumer Healthcare Ltd) was selected for characterization by the AFM-Raman technique. ANADIN is a n analgesic medication, consisting of three active components: Aspirin, Paracetamol, and Caffeine. Each tablet contains approximately 300 mg of Aspirin, 200 mg of Paracetamol and 45 mg of Caffeine. These active ingredients should be combined uniformly to produce a quality tablet. Homogeneous distribution of the components will improve compression characteristics of the tablets, hardness, robustness, lifetime, biocompatibility, assimilability, reduce segregation and defects. Measuring the distribution of the ingredients in the tablet is important for monitoring the manufacturing process and for impurity testing. The tablet was prepared for our measurements by slicing it in half with a steel razor blade so that a flat surface was produced. A fresh clean razor blade was used to avoid sample contamination. The sample exhibits two characteristic types of Raman spectra at different places on the tablet, shown in Fig. 2. These spectra correspond to the two main components of ANADIN: Aspirin and Paracetamol. We did not examine in detail the distribution of Caffeine or the other ingredients of ANADIN. Caffeine is widely spread across the tablet, but present only in small discrete areas. Each ingredient will produce a Raman spectral component with a relative intensity proportional to the ingredient s local concentration. Spectral positions of Raman peaks are different for the different tablet components due to the chemical structure of compounds. The main peaks of Paracetamol can be identified as the C= stretch at 1651 cm, NH deformation mode at 1612 cm, HN-C= bend-stretch at 1559 cm. ther Raman modes in the 1370 to 1166 cm spectral region are due to both the N-H bending and C-H deformation vibrations [ 3]. Raman spectra of aspirin have the characteristic bands at 1606 and 1622 cm (shoulder), which can be assigned to the symmetric aromatic ring CC-stretching vibration and Cstretching vibration of the carboxyl group, respectively. There are several additional bands in the spectral range below 1500 cm. The strongest features are at 1296 and 1045 cm.the first one is attributed to the H-bending vibration. Around 3000 cm, several CH-streching vibrations on different carbons are observed [ 3]. Characteristic Raman spectra of Aspirin and Paracetamol were used to map the distribution of chemical compounds in the ANADIN tablet. Focus Track must be used on these types of samples to avoid confocal signal variations due to profile irregularities a c e 4 µm Fig. 3. Raman mapping: Focus track (a, b) and without Focus track (c, d). Green color corresponds to Aspirin distribution, red color corresponds to Paracetamol distribution. AFM topography image (e), optical image (f). Intensity variations are observed in the marked areas, if Raman measurement is done with and without focus tracking. f b d http:///device/ntegra-spectra

b d f a 5 µm Fig. 4. ANADIN tablet measurements with NTEGRA Spectra: (a) optical image of tablet; (b) AFM height, (c) AFM phase, (d) AFM mag, (e) Raman mapping Paracetamol distribution; (f) Raman mapping - Aspirin distribution; (g) components on the tablet (red color corresponds to Paracetamol, green color corresponds to Aspirin); which are comparable to the axial resolution of the Raman microscope (sample roughness measured by the AFM is about 2 µm). The difference between confocal Raman maps of the c e g tablet taken with and without Focus Track is illustrated in Fig. 3 where the chemical distribution of Aspirin and Paracetamol is presented. Fig. 3 a, b show data measured with Focus Track feature. Fig. 3 c, d show conventional Raman maps taken from the same sample area without using Focus Track. Data measured without Focus Track represents variation of Raman signal intensity due to both variations in chemical composition and sample height. The combination of these two different contributions is not possible to separate. Data measured with Focus Track feature reflects a more accurate mapping of the sample composition. For example, measurements with Focus Track show relatively uniform Paracetamol distribution in the areas marked on Fig. 3 b. Measurements from the same area taken without Focus Track (Fig. 3 d) show non-uniform Paracetamol distribution an artifact due to the variations of the sample height in this area, see Fig. 3 e. The aspirin distribution also shows strong differences, especially in the selected areas, Fig. 3 a, c, when measured with and without Focus Track. Fig. 4 shows Raman maps taken with Focus Track together with corresponding AFM images. The Raman maps reveal a more accurate spatial distribution of the compounds of the ANADIN tablet free from topography artifacts. A phase separation of Aspirin and Paracetamol compounds was observed. Distribution of the Anadin tablet components on the micro level is in accordance with their percentage composition. The amount of Aspirin in the ANADIN tablet is larger, than the amount of Paracetamol. An optical image of the tablet (Fig. 4 a) shows many microcrystalline grains dark and bright areas on the tablet. AFM topography images can provide much deeper insight into the grain structure on the surface (Fig. 4 b-d). Individual grains (not seen on optical images) are perfectly visualized. The smallest particle size of different components can be estimated as 1 5 µm. Phase and magnitude of cantilever oscillation recorded during scanning provide complimentary information to the AFM topography. Phase imaging shows a clear contrast when there is a detectable http:///device/ntegra-spectra

variation of interaction forces between the cantilever and the surface. Thus, phase images highlight grain edges and are not affected by large-scale height differences, providing clearer observation of the sample fine features (Fig. 4c). Magnitude ( cantilever oscillation amplitude signal) provide s additional contrast (Fig. 4 d ); grain edges are also clearly observed because of instantaneous, sharp, changes in the sample height. A clear correlation between AFM and Raman images is observed. Characteristic domains on the tablet with high Paracetamol concentrations seen in the Raman images ( marked with ovals on Fig. 4) has corresponding specific features the AFM images. Acknowledgement: NT-MDT is grateful to Renishaw K.K. (Tokyo) for providing Raman invia Raman spectrometer for the integrated AFM-Raman instrument used in this work. References: [1] Williams AC. Handbook of Raman Spectroscopy: from the Research Laboratory to the Process Line. Practical Spectroscopy Series, vol. 28, Lewis IR, Howell G, Edwards M (eds). Marcel Dekker: New York, 2001; 575. [ 2] http:///device/ntegra-spectra [ 3] Pestaner JP, Mullick FG, Centeno IA. Characterizationof acetaminophen: Molecular microanalysis with Raman microprobe spectroscopy. J Forensic Sci 1996;41(6):1060063. Conclusion Raman microscopy integrated with Atomic Force Microscopy is a powerful analytical tool for pharmaceutical applications. AFM images of tablets provide information about sample topography, grain structure, orientation, and grain boundaries. Raman maps provide distribution of chemical components without the need for complex sample preparation. The Focus Track feature of the NTEGRA Spectra AFM- Raman instrument keeps the sample surface exactly in laser focus even for very rough surfaces, due to the AFM feedback. This allows Raman imaging of rough surfaces without any artifacts coming from sample height variations. In this study, the distribution of Aspirin and Paracetamol components within the ANADIN tablet was studied with high spatial resolution and free of any artifacts due to sample roughness. Correlation between sample chemical composition and AFM image s is observed. http:///device/ntegra-spectra

AFM - Raman - SNM - TERS NTEGRA Spectra Interdisciplinary Research at the Nanometer Scale 100x high NA objective 100x high NA objective Atomic Force Microscopy (>30 modes) Confocal Raman / fluorescence microscopy Wide-field microscopy Scanning near-field optical microscopy (SNM) Tip Enhanced Raman Scattering (TERS) and other tip-assisted optical techniques (s-snm, TERM etc.) Controlled Environment Temperature Humidity Gases Liquid Electrochemical Magnetic Field http:///device/ntegra-spectra