HEMOCHRON. Whole Blood Coagulation Systems

Similar documents
ITC Hemochron Signature Elite

Procedure. Prothrombin Time with INR (PT/INR) Hemochron Signature+ Hemochron Signature Elite. Page 1 of 19. UAMS pt-inr-clsi-procedure

University of Arkansas for Medical Sciences 4301 W Markham Little Rock, AR 72205

Laboratory Monitoring of Unfractionated Heparin Therapy

Note: The taller 100 x 13 mm tube is not designed to run on the ACL TOP. Plasma after centrifugation of these tubes must be placed in sample cups.

PERFUSION TECHNOLOFISTS OF GREATER CHICAGO, INC. POLICY AND PROCEDURE MEDTRONIC HEMOTEC ACTIVATED CLOTTING TIME (ACT) OPERATING PROCEDURE

Coagulation. Coagulation Limited CGL, CGDF Surveys & Anatomic Pathology Education Programs. Coagulation 117

Stability of Plasma for Add-On PT and APTT Tests

PROTHROMBIN TIME WHY USE LOW ISI (HIGH SENSITIVITY)

Sysmex Educational Enhancement & Development

Please consult the Product Package Insert before running the test

QUICK USER GUIDE CAPILLARY BLOOD INR TESTING FOR USING THE THROMBI-STAT MC1 WB INSTRUMENT MANCHESTER CAPILLARY REAGENT INTRODUCTION AND

TECHNICAL BULLETIN. ACT Test Result Calibration Options: PREWARMED vs. NON-PREWARMED Result Calibration BACKGROUND

i-stat iccnet CHSA Edition 1.2 Page 1 of 7 i-stat Rosy Tirimacco / Paul Simpson

Implementation Guide. 3a. Skills Checklist. 3b. Competency Exam. 3c. Answer Key: Competency Exam. 3d. Competency Assessment Checklist

Special Specimen Collection Procedures for Coagulation Testing

I-STAT POCT System PRINCIPLE:

Marcia L. Zucker, Ph.D. ZIVD LLC

High level of agreement between CP3000 and five other coagulation analyzers for INR in a multicenter study

Please consult the Product Package Insert before running the test

Marcia L. Zucker, Ph.D. ZIVD LLC

Marcia L. Zucker, Ph.D. ZIVD LLC

Hemoglobin HemoCue Hb method

Modified Microsample ACT Test for Heparin Monitoring

PAB PRINCIPLE. Kit Reorder # ANNUAL REVIEW Reviewed by: Date. Date INTENDED USE

Department of Laboratories St. Louis, MO ISSUE DATE: June 2007 REVISION DATE: May 2012 REVIEWED DATE: May 2018 PRINCIPLE:

Anti- Tissue Transglutaminase TTG IgG ELISA Kit

Date. Albumin measurements are used in the diagnosis and treatment of numerous diseases primarily involving the liver and/or kidneys.

UK NEQAS FOR BLOOD COAGULATION: Programmi EQAS nel laboratorio di coagulazione

For certification, manufacturers must perform a sample comparison with a Secondary Reference Laboratory (SRL) following the NGSP protocol.

Best Practices in Sample Handling: Part 1 Responses to Participant Questions

Brad Dickinson MSc. MIBMS Chief Biomedical Scientist Leeds Anticoagulant Service

Title: Hemoglobin HemoCue Hb 301 method

Coagulation analyzers POC, self-monitoring

AAG PRINCIPLE SPECIMEN. REF (150 tests) ANNUAL REVIEW Reviewed by: Date. Date INTENDED USE

For the preparation of purified mononuclear immune cells directly from whole blood PACKAGE INSERT. For In Vitro Diagnostic Use PI-TS-IVD-UK-V3

PACKAGE INSERT. For use in the preparation and isolation of purified lymphocytes directly from whole blood. For In Vitro Diagnostic Use

WORTHAM LABORATORIES, INC. DRAFT Thrombin Reagent

CARTRIDGE AND TEST INFORMATION

For the preparation of purified mononuclear immune cells directly from whole blood PACKAGE INSERT. For In Vitro Diagnostic Use PI-TS-IVD-UK-V4

Haemostasis Laboratory, University of Glasgow, Glasgow Royal Infirmary. Prepared by Ann Rumley, Estelle Poorhang. 03/05/05

Same, fewer, small, and single companies in step with latest needs

Falsely Elevated INR Results Due to the Sensitivity of a Thromboplastin Reagent to Heparin

APB PRINCIPLE SPECIMEN. REF (300 tests) ANNUAL REVIEW Reviewed by: Date. Date INTENDED USE

On-Site Specialty Analyzer

Human Bordetella Pertussis IgG ELISA kit

High Five for venous blood collection for immunoassays

SAMPLE PROCEDURE , 11/07

IQCP for the Akers Bio PIFA PlussPF4 Rapid Assay

NGSP Level II Laboratory Information Packet

Canine Cortisol(COR)ELISA Kit

Medical Staff, House Staff, Patient Care Centers, Outpatient Clinics and UC Med Labs Clients

Department of Laboratories St. Louis, MO ISSUE DATE: February 2002 REVISION DATE: August 2011 REVIEWED DATE: May 2017 PRINCIPLE:

The International Haemostasis External Quality Control Program

Sysmex CS-2500 Hemostasis System Unrestricted Siemens Healthcare Diagnostics Inc All rights reserved.

Comparison of Several Activated Partial Thromboplastin Time Methods

DOACs: When and how to measure their anticoagulant effect

SAMPLE H21-A5. January 2008

I-SPOT Laboratory Manual Log of Changes from Version 3 to Version 4

Applicable To Employees of the Gundersen Palmer Lutheran Hospitals and Clinics laboratories.

PCR / RT-PCR Kit User s Manual (48T)

Date. Alkaline phosphatase measurements are used in the diagnosis and treatment of liver, bone, parathyroid, and intestinal diseases.

For In Vitro Diagnostic Use

IQCP for the Akers Bio PIFA Heparin Platelet Factor 4 Rapid Assay

CLSI C60: Assay Validation & Post-Validation Monitoring

All data should be sent by from the laboratory and from the SRL by directly to the NGSP Network Coordinator (above address).

ACT Plus. Automated Coagulation Timer. Precise, reliable the trusted standard.

Point of Care Testing

What it takes to make a new state of the art diagnostics platform for Point of Care use.

For In Vitro Diagnostic Use

LabNotes. Blood Testing: A Newsletter from BD Vacutainer Systems, Preanalytical Solutions

Rat Cortisol(CORTISOL)ELISA Kit. Instruction. Sample Types Validated Serum, blood plasma,saliva, Urine, and other related tissue Liquid.

With Stago, discover an outstanding Routine range

Laboratory Quality Control Management System. A New Approach to Quality Control

General News. Product Notes. Instrument Notice HELENA SALES FORCE TO: FROM: SUBJECT: HELENA POINT OF CARE ROUND-UP/US DOMESTIC DATE: 9/1/2009

GENERAL INFORMATION ORDERS AND RESULTS

Physician Orders - Adult

Automated Coagulation Analyser product list 2018

2009 LAP Audioconference Series. Simple Tests, Tough Problems Patient Care and Laboratory Inspection in Coagulation

Sheep oxytocin (OT) ELISA Kit

Coagulation analyzers (point of care, self-monitoring)

Hawaii Island Rat Lungworm Working Group Jarvi Lab Veterinary Sample Submission Protocol. Non-human animal blood and CSF Protocol

COLORIMETRIC SANDWICH ELISA KIT INSTRUCTION MANUAL

Hamster follicle stimulating hormone (FSH) ELISA Kit

General Principles of. Hemostasis. Kristine Krafts, M.D.

Human placenta lactogen (HPL) ELISA Kit

UW Medicine Alternative Monitoring for Antithrombotic Agents

Human CRP Precoated ELISA kit

The Lifecycle of a Sample

Mouse Collagen Type III ELISA

Bovine anti-mullerian hormone (AMH) ELISA Kit

Human Hyperglycosylated Chorionic Gonadotropin (hcg) ELISA Kit

Human Hyperglycosylated Chorionic Gonadotropin (hcg) ELISA Kit

Bovine Prostaglandin E2 (PG-E2) ELISA Kit

Mouse thyroxine(t4) ELISA Kit

RxDx Analysis Module Heparin and Protamine Dosing. Operator s Manual English. Response TABLE OF CONTENTS

Dry Hematology Analyzer Fast, Simple CBC Analysis Designed for the Point of Care

Human ferritin(fe) ELISA Kit

Fish Estradiol(E2) ELISA Kit

Discussion. Objectives:

Transcription:

HEMOCHRON Whole Blood Coagulation Systems Activated Partial Thromboplastin Time (APTT) Cuvette Correlation Protocol for HEMOCHRON Microcoagulation Instruments MSIG: 49 10/06

Dear Medical Professional: Thank you for your interest in evaluating the HEMOCHRON Jr. Microcoagulation system for your near patient coagulation testing needs. The HEMOCHRON Jr. offers a simple, one-step procedure using fresh whole blood samples to evaluate essential coagulation parameters: the ACT+, ACT-LR, APTT and PT. Test results are reported in plasma equivalent values and INR for PT, plasma equivalent values for APTT and in celite ACT equivalent values when performing the ACT+ or ACT-LR. By converting whole blood results into traditional, laboratory test value form, the HEMOCHRON Jr. delivers results in familiar clinical parameters facilitating accurate clinical data interpretation. In this way, near-patient testing can truly become an extension of the clinical laboratory. Because of the varying sensitivities of different brands and lots of plasma based APTT reagents, and because of different methodologies used on coagulation instrumentation, results obtained using various combinations of instrument/reagent systems will differ. Studies have shown that in the majority of instances clinical interpretation of test results is similar even if the actual results are not identical. The inherent value of point-of-care hemostasis monitoring, namely timeliness of test results, must be supplemented by determination of correlation with your current method. While no two coagulation instrument/reagent systems produce results that match exactly, systems can be correlated to provide statistically acceptable results so as not to alter the overall clinical interpretation of the test results. To perform a correlation between two systems, ideally, samples would be tested simultaneously on each system using the same blood sample. Logistically, this becomes difficult when one system performs tests using a whole blood sample at the bedside, and the other system uses a plasma based sample and is performed in the laboratory. ITC suggests the attached recommended correlation protocol and data collection form to minimize the data collection variables (such as time elapsed between blood sample collection and test performance) when performing a correlation between whole blood and plasma-based coagulation systems. The protocol is segmented into parts to allow the user to become familiar with the HEMOCHRON Jr. test procedures prior to actual data collection for correlation. Obtaining a good correlation between the two systems requires that the operator be proficient at both procedures prior to beginning data collection, and that strict adherence to the guidelines be followed. We recommend that you fax us a copy of your correlation data once you have completed the protocol. Often, upon examination of the data, we find the correlation between the two systems can be improved (i.e. by performing a few more tests in a sensitivity range where there may not be many data points). Together, we are certain that a good correlation can be obtained between the HEMOCHRON Jr. and your laboratory system. If at any time during the correlation process you require assistance, do not hesitate to contact our in-house Technical Service staff at 1-800-631-5945. Thank you for your interest in evaluating our point-of-care analyzers. We are certain you will find them to be an important supplement to the diagnostic protocols you currently employ.

HEMOCHRON Jr. APTT Clinical Correlation Protocol Prior to clinical use, a correlation study comparing the HEMOCHRON Jr. APTT test and standard laboratory assay will assist in determining any necessary target time adjustments. Prior to initiating the Clinical Correlation, review all package inserts and the HEMOCHRON Jr. operator s manual for complete instructions. Review this entire protocol before beginning a test. Patient Population: 1. A sufficient number of samples must be obtained to span the entire normal and therapeutic range. 2. The table at the bottom of the attached data collection form indicates the breakdown of the number of paired samples required in each sensitivity range. 3. The normal range samples (volunteer normal donors) should be done first, prior to collecting specimens from anticoagulated patients. Material Preparation: 1. Bring all cuvettes to room temperature. This may require up to 1 hour. 2. Perform instrument quality control (as per the HEMOCHRON Jr. Operator s Manual) using the HEMOCHRON Jr. EQC test cartridges, or directcheck Quality Control test products. Test Procedure: 1. Insert the appropriate cuvette into the HEMOCHRON Jr. analyzer. The instrument will display a number of messages (i.e. pump warming...) while performing a series of internal tests. Do not collect any blood sample until the analyzer display reads ADD SAMPLE PRESS START. Once displayed, you have 5 minutes to collect the fresh whole blood sample and add it to the cuvette. Blood Collection: 1. Collect 5 ml of fresh whole blood. (When using a 2 syringe technique, make sure to use the second draw.) 2. Using the collection syringe, immediately add the blood sample to the center well of the HEMOCHRON Jr. cuvette. Fill the center well of the cuvette flush to the top (if a large dome forms on top of the well, push it over into the outer well). Depress the START button on the analyzer. Note: If the blood sample is collected and added to the cuvette prior to the analyzer being ready, a fault message will most likely be displayed, and the result will be invalid. If sample collection exceeds the 5 minute time limit, the analyzer will display a START TIMEOUT message, and you will need to discard the cuvette and replace it with a new cuvette, according to the package insert instructions.

3. Immediately fill an evacuated blue top tube containing sodium citrate using either the blood sample remaining in the syringe, a new syringe or butterfly collection device. This sample is to be used in the clinical laboratory to perform the plasma test. Note: Either 3.2% or 3.8% sodium citrate tubes may be employed. However, differences exist between laboratory test results with each citrate concentration. It is therefore critical that only one concentration be used by a single medical facility. 4. Immediately label the citrated blood sample with STAT CORRELATION STUDY and patient ID and immediately transport to the clinical laboratory. 5. Record the HEMOCHRON Jr. results upon completion of the test (indicated by an audible beep). 6. The comparative plasma test is to be performed using the standard lab procedure. The laboratory assay must be performed within 60 minutes of specimen collection. Recording Results: Record all information on attached data sheets. 1. Record specimen draw time and time that laboratory result was obtained. 2. Record HEMOCHRON Jr. results: plasma equivalent result for APTT 3. Record the corresponding laboratory plasma APTT result. 4. Once a minimum of 30 sets of data points distributed over the desired clinical range have been collected, call ITC Technical Service (800-631-5945) and arrange to have the collected data faxed to them for review and analysis. 5. Once analysis is complete, Technical Services will contact you to discuss whether your correlation is acceptable, or whether additional data is required. Interpretation of results: Clinical correlations demonstrate the statistical similarity of the two test systems. Data is analyzed using a linear regression model. The correlation coefficient (r) indicates the degree to which data points deviate from the line of best fit. A perfect correlation of 1.0 indicates each data point is matched to the control method, measured against a line of best fit. The slope of the regression line indicates a bias in either test method. In order to have two tests be identical, both the correlation coefficient (r) and the slope of the regression line must be 1.0. Correlations of HEMOCHRON whole blood assays to laboratory method are generally 0.88 or greater. This indicates the tests are statistically similar, yet actual differences of individual data points are expected.

HEMOCHRON Jr. APTT CORRELATION PROTOCOL DATA SHEET Hospital: Investigator: Address: Jr. APTT Cuvette lot number: Date: Title: Phone: Jr. model/serial number: Patient # Draw Time HEMOCHRON Jr. Whole Blood Result Plasma Equiv. Result Time tested in lab Lab Plasma Value Comments/ Indicate if patient is on heparin 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 Sensitivity Range Target Plasma APTT Range Number of Patients Normal min. of 9 35-54 min. of 8 55-74 min. of 7 75-95 min. of 6