NUFLO Liquid Turbine Flow Meters

Similar documents
7000 Series Liquid Turbine Meters

BARTON Floco/Flotrac Meters, Floco Samplers and Pulse Transmitters

Calibration Laboratory

Model 5100 Model 5400 Insertion Turbine Flowmeters for Liquid and Gas

Severe Service Technology, Inc.

WYATT Orifice flow PrOducTs

12D SERIES THREE SCREW PUMPS ROTARY SCREW PUMPS

KRAL Volumeter - OME Series Economy Flowmeters

Target Inline Flowmeter

KRAL Volumeter - OMG Series Universal Flowmeters

VERIS Accelabar. Superior Flow Measurement Accuracy

Product Data Sheet. Turbine Flow Meters. Precision Series Gas Meters DESCRIPTION OPERATION APPLICATION CALIBRATIONS

LIQUID CONTROLS. Terminal and Bulk Plant Metering Applications. Application Brochure:

METAL BELLOWS SEAL 3604/3604HTC/3604HTCDP Technical Specification

Thermostatic Control Valve

Data Sheet ANO. Hygienic Type Turbine Flowmeter. Supplied by. .com. Call us on +44 (0)

1604/2609/3609 TYPE 1604/2609/3609. First Edition API 682 Type C Sealol Metal Bellows Seals. Product Description. Performance Capabilities

Not Just Tight Shut Off Very Tight Shut Off!

TURBINE METER SERIES FMT-S

Gilflo flowmeters. for steam, liquids and gases

COIN. Flow Meters. Segmented Wedge. Your First Choice in Intelligent Flow Management...

ABB Kent-Taylor. Turbine Meter PTF. PTF meter for guaranteed reliability and high accuracy in a turbine meter. Wide flow range up to 40:1

heliflu tm The Dedicated Turbine Flowmeter for Custody Transfer Measurement Proven Performance Main Applications

heliflu tm The Dedicated Turbine Flowmeter for Custody Transfer Measurement Proven Performance Main Applications

3.1 Rev Features. Horizon. Materials and Specifications. Horizontal Turbine Meters Sizes 1-1/2", 2"

VENTURI FLOWMETERS. Your First Choice in Intelligent Flow Management...

VIKING. Serving Applications For: Ambient-Temperature Solids Temperature-Critical Processes Extreme Environments

Diffused Aeration Piping Equipment

Handling Fluid Fertilizers Selecting the Right Equipment Components

1.2 REFERENCES.1 American National Standards Institute (ANSI)/American Society of Mechanical Engineers (ASME).

EUROPE S LARGEST SELECTION OF TEST & MEASUREMENT EQUIPMENT FOR HIRE INLEC.COM. Nationwide Low Call

LIQUID-SPECIFIC PRODUCT LINE: ABRASIVE LIQUID PUMPS SERIES DESCRIPTION OPERATING RANGE: IMPROVEMENTS NOMINAL FLOW RATES:

Valves For Heavy Oil Applications

Mark-II and Mark-IIE Turbo-Meters

The Unique Accelabar Flow Meter

Iron Check Valves & Y-Strainers Illustrated Index

Roxar Weight Loss Coupon Holder and Coupons 1 Retractable System

Type 5860 Slurry Seal Designed Specifically for Slurry Pumps and Equipment

UNIVERSAL PRODUCT LINE: CAST IRON MAG DRIVE PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE

Experience In Motion ECPJ. API 610 (VS4) Vertical Sump Pump

BARTON Floco. Liquid positive displacement flowmeter

NPS ½ - 4 DN ASME Limited Class 1700, 3100, 4500 Severe Service Metal Seated Ball Valves

HELIFLU TM TZN. The Dedicated Turbine Flowmeter for Custody Transfer Measurement. Proven Performance. Main Applications

ALLOY BALL VALVES 7000 SERIES METAL AND SOFT SEATED 150# TO 2500#

RHM80. High Flow Coriolis Mass Flow Meter. Features. Applications. Benefits

RHM60. Coriolis Mass Flow Meter with Uncompromising Performance. Features. Applications. Benefits

Wellhead & Gate Valves

VLM10 In-line Vortex Mass Flow Meter

Product Data Sheet. Vortex Flow Meter. RVL Series DESCRIPTION APPLICATION OPTIONAL SOFTWARE OPERATING PRINCIPLE CONSTRUCTION

WE PROVIDE QUICK RELIABLE AFTERSALES SERVICE AND SUPPORT FOR OUR CUSTOMERS

Pump Division MNR MND. Absorber Recirculation Pumps. Bulletin PS (E)

DIVISION 15- MECHANICAL Section Fire Pumps

80 Series. Multi-purpose cartridge seals

Engineering Data Pack HD Industrial Duty Pumps

VIKING. Heavy-Duty, Foot-Mounted Sealless Internal Gear Pumps. Operating Range1: Nominal Flow Rates: Section 635 Page 635.

Figure 3. 1 ½ Nutating Disc with R-10 register

PARTS & ACCESSORIES: EATON DUPLEX BASKET STRAINERS FEATURES OPTIONS MODEL 53BTX DUPLEX (3/4 TO 4 ) MODEL 50 DUPLEX (5, 6, 8 )

Orifice Plates. All types of Orifice Plates and. relative products

UNIVERSAL PRODUCT LINE: STAINLESS STEEL MAG DRIVE PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE

Sentinel LNG. Panametrics Ultrasonic Flowmeter for Cryogenic Liquids. GE Sensing & Inspection Technologies. Benefits. Applications

KTM METALTITE BALL VALVES FLOATING AND TRUNNION TYPE

Goulds Multistage Process Pumps

Nettco S-Series Mixer SANITARY STAINLESS STEEL - PORTABLE/FIXED MOUNT MIXERS

Suitable for use in a variety of fluid systems.

M7100 Pressure Transducer

O P T I M U M - F L O W T E C H N O L O G Y B Y P I P E R MST. Series. Photo Courtesy of Tullow Oil O I L S T A T E S P I P E R V A L V E

Original Chiksan Swivel Joints

2 and 3 T-10 Turbo-Meters Turbine Meters for Accurate Gas Measurement. M-1083 Rev. 4

2 and 3 T-10 Turbo-Meters Turbine Meters for Accurate Gas Measurement. M-1083 Rev. 3

Sponsler Precision Turbine Flowmeters

M Series Floating Metal Seat Ball Valve

Ball Float Steam Trap UNA 45, UNA 46, UNA 46A PN 40/Class 300 DN 15, 20, 25, 40, 50, 65

Available End Connections & Size Range

Datasheet Rev.4 Jan 2015 Orifice plate - Overview

VIKING. Heavy-Duty, Foot-Mounted Sealless Internal Gear Pumps. Operating Range1: Nominal Flow Rates: Section 635 Page 635.

PVXM API 610 / ISO (OH3)

KRAL Volumeter - OMG Series Universal Flowmeters

Gilflo ILVA flowmeters for steam, liquids and gases

T Series. Self-Priming Centrifugal Pumps

Fiberglass Epoxy GRE Integral Joint Tubing

Reconditioning Services

Bettis G-Series Spring-Return Pneumatic Valve Actuator Component Material List. Material List ML.GP Rev. 0 October 2017

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y SWP. Self Priming Pump

Sentinel LNG. Panametrics Ultrasonic Flowmeter for Cryogenic Liquids. GE Sensing & Inspection Technologies. Benefits. Applications

Pump Division LNN. Between Bearing, Axially Split, Single Stage, Double Suction Pump. Bulletin PS-20-1f (E/A4)

FAIRBANKS NIJHUIS SUBMERSIBLE SOLIDS HANDLING PUMPS.

Autogas Series. Regenerative Turbine Coro-Flo Pumps For High Differential Pressure Applications Using LPG and Other Liquefied Gases.

Rosemount 1152 Alphaline Nuclear Pressure Transmitter

Presentation Overview

YARWAY WYE-TYPE PIPELINE STRAINERS 900 SERIES

Isolation Gaskets 101

SECTION TURBINE VENTILATORS

TYPE 37FS Fully Split Seal

Autogas Series. Regenerative Turbine Coro-Flo Pumps. For LPG High Differential Pressure Applications

Datasheet Rev.1 Feb 2016 Orifice plate multi-holes

Model B. Thermostatic Control Valves. Typical applications

High-Performance Edge-Welded Metal Bellows Seals

Since its inception in 2011, YUCO ALLIANCE DMCC provides superior products and service solutions to the diverse streams such as upstream, midstream,

VESSEL & REACTOR VALVES. VR Series RISING DISC PROCESS VALVES. Sold by: G&W Industrial Sales

Experience In Motion MPT. Self-Priming, Solids-Handling Pump

Transcription:

TECHNICAL SPECIFICATIONS NUFLO Liquid Turbine Flow Meters Accurate Flow Measurement In 957, this flow meter was developed with a tungsten-carbide shaft and bearing to withstand the rugged conditions of the oil field. Over the years, it has earned an unsurpassed reputation for withstanding severe punishment while maintaining operational and measurement integrity. Today, it remains a strong seller among Cameron s NUFLO liquid measurement products. NUFLO turbine flow meters indicate flow rate and measure total throughput of a liquid line. As liquid flows through the meter and over the rotor, the rotor turns at a speed that is directly proportional to the flow rate. A magnetic pickup senses the rotor blades as they pass and generates an electrical (sine wave) signal. These electrical pulses are then transmitted to the flow measurement readout equipment. Benefits Accurate and repeatable measurement An economical solution for turbine flow meter applications Easy installation and a variety of end connections Minimum maintenance required Long service life even in severe applications

First Class Design Delivers First Class Performance 4 2 3 5 6 8 7. Permanent MNPT conduit connection is standard. 2. Rotor is pitched and pre-calibrated to determine accuracy. 3. End Connections available as a flanged, threaded, grooved, EZ-IN and WECO 502. 4. Flow Vanes increase performance at low rates. 5. Flow Vane Hub supports rotor assembly. 6. Rotor Shaft, Bearings and Thrust Ball are made of tungsten carbide for long service without lubrication other than by the process liquid. 7. Retaining Rings make disassembly easy. 8. Flow Meter Body is a sturdy, one-piece construction, precision finished. Applications Cameron offers turbine flow meters in a variety of end connections and accuracy levels. Typical applications are: Water-injection measurement Heater treaters Test and production separators Disposal wells CO 2 injection Steam generator fuel and feed water Metering liquid fertilizer Water, fuel and chemical measurement in plant settings Chemical tank loading and unloading Measuring liquid propane In-situ mining and leaching Accuracy Cameron offers two meter grades to satisfy various linearity requirements. The standard grade meter is a cost-effective solution for applications requiring accuracy of % or less. For higher accuracy, an industrial grade meter can be used. Greater accuracy may be achieved if the expected flow range is specified. Meter Grade Linearity Repeatability Standard ± % of reading ± 0.05% Industrial ± 0.5% of reading ± 0.02% Enhanced accuracy Consult factory Consult factory For 3/8 meters, linearity is ± 2% of reading (standard) and ± % of reading (industrial). 2

Temperature Range (magnetic pickup) Temperature Range Flow Meter Size -67 F to 250 F (-55 C to 07 C) 3/8 through 3/4 Standard -67 F to 250 F (-55 C to 2 C) 7/8 through 8 Medium -67 F to 450 F (-55 C to 232 C) all sizes Note: Consult Cameron s Measurement Systems division for any use of turbine flow meters below -20 F (-29 C) or above 250 F (2 C). Compliances CSA certified for hazardous areas, Class I, Div., Groups A, B, C, D Meters with maximum working pressures below 7500 psi are compliant with ANSI 2.27.0-2003 single seal EZ-IN meters and WECO 502 union meters available with CE mark for Pressure Equipment Directive (PED, 97/23/EC) Materials of Construction Meter body (standard): Grade 36L stainless steel Meter body (high pressure): A286 stainless steel Vanes: Grade 36L stainless steel Rotor: CD-4MCu Shaft and bearings: Tungsten carbide Traceability of pressure-containing components available on request. Optional Materials Shaft Binderless carbide for enhanced corrosion resistance to selected chemicals. Meter Size Selection Flow meter size selection should be based on the instantaneous flow rate of the line into which the meter will be mounted and on the meter pressure drop. Meter size should never be based on the nominal piping size of the installation. Refer to the linear flow range chart (page 3) and the pressure drop curve chart (page 6) for meter size selection. The meter will remain accurate at flow rates higher than its rating, but over-ranging a meter for long periods can cause excessive bearing wear and pressure drop and shorten the life span of the meter. NUFLO flow meters can be over-ranged by 0% for short periods without damage. Installation The meter should be installed so that the arrow on the meter body corresponds to the flow direction of the line. A 0 diameter length of straight unrestricted pipe must be upstream and a five diameter length of straight unrestricted pipe must be downstream of the flow meter. Both pipe sections should be the same nominal pipe size as the flow meter s end connection. Throttling/control valves should be located downstream of the flow meter. Magnetic Pickup/Electronics Installation The meter s permanent conduit connection has MNPT threads for attaching an electronic readout instrument. The conduit connection is designed for use with a 5/8 to 8 threaded magnetic pickup which is sold separately by Cameron. Shaft and Bearings Silver brazing to withstand temperatures to 550 F (288 C) and chemicals that attack epoxy bonding bearing materials. Rotor Nickel plating for enhanced corrosion resistance to selected chemicals (especially acids that corrode ferrous materials). 3

Linear Flow Range Flow Meter Size (3) (, 2, 3) Nominal (2) Calibration Factor Maximum Output Frequency P at Maximum Flow (2) in. mm GPM m 3 Pulses Pulses x /HR BPD Gallon 000/m 3 Pulses/Sec psi kpa 3/8 0 0.3 3 0.068 0.68 0 00 22000 (582) 00 4.0 28 3/8 0 0.3 3 0.068 0.68 0 00 22000 (582) 00 4.0 28 /2 3 0.75 7.5 0.7.70 25 250 4500 (3830) 85 2.0 83 3/4 9 2 5 0.45 3.4 68 55 2950 (780) 740 8.0 24 7/8 22 3 30 0.68 6.8 00 000 2350 (62) 75 20.0 38 25 5 50.4.36 70 700 900 (238) 750 20.0 38 -/2 38 5 80 3.4 40.88 55 6000 325 (86) 975 6.0 0 2 5 40 400 9.09 90.85 300 3,000 55 (4.5) 365 22.0 52 3 76 80 800 8.6 8.66 2750 27,500 57 (5.2) 760 20.0 38 4 02 00 200 22.7 272.55 3400 4,000 30 (7.9) 600 0.0 69 6 52 250 2500 56.78 567.82 8600 86,000 7 (.8) 290 0.0 6 8 203 350 3500 79.49 794.94 2,000 20,000 3 (.8) 75 6.0 4 () The linear flow range of liquids with non-lubricating characteristics is limited to the upper 60% of rating. (2) Based on water. (3) Consult Cameron s Measurement Systems division for engineering assistance with applications involving liquids of viscosities greater than 5 centistokes on 3/8 through 3/4 meters. End Connections NUFLO flow meters are available in a variety of end connections: Threaded Grooved Flanged EZ-IN WECO 502 Threaded (NPT) End Connections Threaded meter sizes range from 3/8 to 2. Meter sizes from 3/8 to pipe all have NPT end connections to simplify meter size changes. All meter sizes other than the 2 have male threads. End Connection Size Working Pressure Length in. psi MPa in. mm 3/8 x 7500 5.7 4.0 02 /2 x 7500 5.7 4.0 02 3/4 x 7500 5.7 4.0 02 7/8 x 5000 34.5 4.0 02 x 5000 34.5 4.0 02 -/2 x -/2 5000 34.5 6.0 52 -/2 x 2 5000 34.5 6.0 52 2 x 2 5000 34.5 0.0 254 3 x 3 000 6.9 2.5 38 4 x 4 000 6.9 2.0 305 4

Flanged End Connections Turbine flow meters with flanged end connections are available in both raised-face (RF) models and ring-type joint (RTJ) models. Flanged NUFLO meters are constructed with carbon steel or stainless steel slip-on flanges or machined from a single block of stainless steel. Slip-on flanges are welded to the outside of the meter to ensure that the flange never comes into contact with the process fluid. The flanges are designed to mate with ANSI B6.5 flanges. Contact the factory for availability of materials and construction types for a desired meter size. End Connection Size Flange Pressure Rating Length in. psi in. mm 3/8 x /2 50, 300, 600 900, 500, 2500 /2 x /2 50, 300, 600 900, 500, 2500 3/4 x 3/4 50, 300, 600 900, 500, 2500 5.0 6.25 5.0 6.25 5.0 6.25 27.0 58.8 27.0 58.8 27.0 58.8 7/8 x 50, 300, 600, 900, 500, 2500 6.0 52.4 x 50, 300, 600, 900, 500, 2500 6.0 52.4 -/2 x -/2 50, 300, 600, 900, 500, 2500 7.0 77.8 2 x 2 50, 300, 600, 900, 500, 2500 8.5 25.9 3 x 3 50, 300, 600, 900 500 2500 4 x 4 50, 300, 600, 900 500 2500 6 x 6 50, 300, 600, 900 500 0.0 2.0 5.0 2.0 4.0 6.5 2.0 6.0 254.0 304.8 38.0 304.8 355.6 49. 304.8 406.4 8 x 8 () 50, 300, 600, 900 2.0 304.8 () Contact factory for other flange classifications above 900#. Flange Maximum Working Pressure Design-operating Pressure Rating Flange Material Temperature Range psi Carbon Steel Stainless Steel 50 300 600 900 500 2500 Test Pressure:.5 times maximum working pressure at 285 psi 260 psi 200 psi 85 psi 740 psi 680 psi 635 psi 620 psi 480 psi 360 psi 265 psi 235 psi 2220 psi 2035 psi 900 psi 855 psi 3705 psi 3395 psi 370 psi 3093 psi 670 psi 5655 psi 5280 psi 553 psi.96 mpa.79 mpa.38 mpa.28 mpa 5.0 mpa 4.69 mpa 4.38 mpa 4.27 mpa 0.2 mpa 9.38 mpa 8.72 mpa 8.52 mpa 5.3 mpa 4.0 mpa 3. mpa 2.6 mpa 25.5 mpa 23.4 mpa 2.8 mpa 2.3 mpa 42.5 mpa 39.0 mpa 36.4 mpa 35.5 mpa 275 psi 235 psi 95 psi 83 psi 720 psi 600 psi 495 psi 480 psi 440 psi 200 psi 995 psi 963 psi 260 psi 800 psi 490 psi 443 psi 3600 psi 3000 psi 2485 psi 2408 psi 6000 psi 5000 psi 440 psi 400 psi.89 mpa.62 mpa.34 mpa.26 mpa 4.96 mpa 4.4 mpa 3.4 mpa 3.3 mpa 9.92 mpa 8.27 mpa 6.86 mpa 6.64 mpa 4.9 mpa 2.4 mpa 0.3 mpa 9.95 mpa 24.8 mpa 20.7 mpa 7. mpa 6.6 mpa 4.3 mpa 34.5 mpa 28.5 mpa 27.6 mpa 5

Grooved End Connection Flow meters with grooved end connections are available in 7/8 through 8 sizes. Flow Meter Size x End Connection Size Length Working Pressure in. in. mm psi MPa 7/8 x 4.0 02 000 6.9 x 4.0 02 000 6.9 -/2 x -/2 6.0 52 000 6.9 -/2 x 2 6.0 52 000 6.9 -/2 x 2 6.0 52 2500 7.2 2 x 2-/2 0.0 254 000 6.9 3 x 3 2.5 38 000 6.9 4 x 4 2.0 305 000 6.9 6 x 6 2.0 305 800 5.5 8 x 8 2.0 305 800 5.5 WECO 502 Union End Connection Flow meters with WECO 502 end connections are commonly used in high-pressure oilwell service applications. Meter sizes, -/2 and 2 have 2 union end connections with a wing nut on one end and threads on the other end. The 3 meters have 3 union end connections with the option of a wing nut on one end and threads on the other, or threads on both ends. All WECO 502 union end connection meters have two pickup adapters. End Connection Size Length Working Pressure in. in. mm psi MPa x 2 8.00 203.3 5,000 03 -/2 x 2 8.60 28.4 5,000 03 2 x 2 9.00 228.6 5,000 03 3 x 3 3.0 330.2 5,000 03 EZ-IN End Connection EZ-IN series turbine flow meters provide a cost-effective alternative to typical flanged meters. They offer the accuracy, rugged construction, and maintenancefree operation of conventional NUFLO flow meters plus the following advantages: Lower installation cost Less expensive than a conventional, flanged meter Easy installation, removal and inspection Mates to any raised-face flange rated ANSI 50# to 500# Mates to any ring joint flange rated ANSI 900#, 500# or 2500# Reduced-bore designs (e.g. x 2 end connection) enable flow range adjustments without changing end connections. Specialized Flow Meters High pressure Cement slurry Nitrogen Corrosive service CO 2 Drilling fluids (, 3) Meters for use with Raised Face Flanges End Connection Size (2) Lengths, in. (mm) in. 2 3 4 6 8 3/8 x 4.0 (02) /2 x 4.0 (02) 3/4 x 4.0 (02) 7/8 x 4.0 (02) x 4.0 (02) 3/8 x 2 2.5 (63.5) /2 x 2 2.5 (63.5) 3/4 x 2 2.5 (63.5) 7/8 x 2 2.5 (63.5) x 2 2.5 (63.5) -/2 x 2 2.5 (63.5) 2 x 2 2.5 (63.5) 2 x 3 4.25 (08) 3 x 3 4.25 (08) 4 x 4 5.0 (27) 6 x 6 5.75 (46.) 8 x 8 (3) 6.25 (58.8) () Specify flange type (raised face or ring joint) when ordering. (2) Cameron offers multiple flow meter sizes for many end connection sizes, making it easy to adapt to changing flow rates (3) CE-marked meter requires special centering rings. Contact Cameron s Measurement Systems division for application assistance. 6

Meters for use with Ring Joint Flanges TECHNICAL SPECIFICATIONS End Connection Size Lengths, in. (mm) in. 2 3 4 6 8 x 2 3.5 (88.9) -/2 x 2 3.5 (88.9) 2 x 2 3.5 (88.9) 3 x 3 4.25 (08) 4 x 4 5.0 (27) 6 x 6 5.75 (46.) 8 x 8 6.25 (58.8) Specify flange type (raised face or ring joint) when ordering. Pressure Drop Curve for NUFLO Turbine Flow Meters 30 (206.84) Flow Rate - BPD 5 0 50 00 500,000 5,000 0,000 50,000 00,000 0 (68.95) 5 (34.47) Pressure Drop - PSI (kpa) (6.90) 0.5 (3.45) 0. (.690) 0.05 (.345) 3/8 /2 3/4 7/8 -/2 2 3 4 6 8 0.0 (.069) 0. (.02) 0.5 (.) (.23) 5 (.4) 0 (2.27) 50 00 (.36) (22.7) 500 000 (3.6) (227.) 5000 (36.4) Flow Rate - GPM (m 3 /hr) Fluid is water at 68 F (20 C) 7

NORTH AND SOUTH EUROPE, AFRICA, CASPIAN ASIA PACIFIC MIDDLE EAST AMERICA AND RUSSIA Suite 6.02 Menara AmFirst Level 9, Al Jazira Club Tower A 4450 JFK Blvd. 3 Steyning Way No. Jalan 9/3 P.O. Box 47280, Muroor Road Houston, TX 77032 Southern Cross Trading Estate 46300 Petaling Jaya Abu Dhabi USA Bognor Regis Selangor Darul Ehsan United Arab Emirates Tel 28 582 9500 West Sussex PO22 9TT Malaysia Tel 97 2 596 8400 ms-us@c-a-m.com England, UK Tel 603 7954 045 ms-uk@c-a-m.com Tel 44 243 82674 ms-kl@c-a-m.com ms-uk@c-a-m.com ALGERIA CANADA CHINA INDIA MALAYSIA RUSSIA UAE UK USA www.c-a-m.com/measurement 203 Cameron NUFLO is a trademark of Cameron. WECO is a federally registered trademark of FMC Technologies, Inc. SWP 2M 04/3 AD0056M