Louis Armstrong New Orleans International Airport NOAB Project # North Terminal Development Program Phase 1

Similar documents
SECTION MANUFACTURED ROOF EXPANSION JOINTS

SECTION C. Water Infiltration: Provide manufactured cupolas and dormers that do not allow water infiltration to cupola and dormer interiors.

Architectural Wall Products Guide Specifications

SECTION COMPOSITE WALL PANELS PART 1 GENERAL 1.01 SECTION INCLUDES

Architectural Roof and Wall Products Guide Specifications

SECTION ROOF SPECIALTIES

Architectural Roof Products Guide Specifications

Architectural Roof and Wall Products Guide Specifications

3. Roof Expansion Joints between New Building and Existing Building.

Expansion Joint Covers (079513)

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Architectural Roof Products Guide Specifications

Expansion Joint Covers

SECTION EXPANSION CONTROL

SECTION COLD-FORMED METAL TRUSSES

Architectural Roof and Wall Products Guide Specifications

SECTION EXPANSION CONTROL

SECTION EXPANSION CONTROL

SECTION EXPANSION CONTROL

SECTION ROOF MOUNTED ATTIC EXHAUST VENT

SECTION PRE-ENGINEERED COLD-FORMED METAL ROOF AND FLOOR TRUSSES

1. Selective Demolition Section Adhered PVC Roofing System Section Sealants and Caulking Section 07920

University of New Hampshire Scholars' Repository

SECTION ELECTRICAL POWER ATTIC EXHAUST VENTILATOR

Section PANEL SIGNAGE

SECTION TURBINE VENTILATORS

SECTION COMMERCIAL CURB-MOUNT ACRYLIC DOUBLE DOME SKYLIGHTS

SECTION EXPANSION CONTROL

SECTION EXPANSION CONTROL

SECTION METAL ROOF AND SOFFIT PANELS

SSL-175. Specifications

Corium Brick Rainscreen System Specifications

A. Pre-Installation Conference: Conduct conference at [project site] <insert location>.

LOG COLLEGE MIDDLE SCHOOL


Project Name Project # Project Information

OSU PROJECT NO PAGE 1 02 NOV 2006 SECTION METAL ROOF PANELS

SECTION THERMOPLASTIC MEMBRANE ROOFING PART 1 GENERAL 1.01 SECTION INCLUDES

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

SECTION STAINLESS STEEL WALL PANELS

Guide Specifications ADP Series SECTION SHEET METAL ROOFING

Page 1 of 5

NRM-7000 Guide Specifications

1. Temperature Change: 120 deg F (67 deg C), ambient; 180 deg F (100 deg C), material surfaces.

SECTION 07530CP EPDM MEMBRANE ROOFING

DL-200. Specifications

SECTION EXTERIOR SOLID PHENOLIC RAINSCREEN PANELS

SECTION EXTERIOR GRILLS AND SCREENS

SECTION STANDING SEAM METAL ROOFING

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Ice Rink Renovation & New Clubhouse

Student Services & Classroom Addition

MARQUIS Tualatin FIBER-CEMENT SIDING June 15, rev

A. Omega-Lite aluminum-faced composite panels, air and vapor barrier, attachments and sealants.

SECTION COLD-FORMED METAL FRAMING

SECTION THERMOPLASTIC POLYOLEFIN (TPO) ROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SECTION COLD-FORMED METAL FRAMING

A. Pre-Installation Conference: Conduct conference at [project site] <insert location>.

SECTION ROOF ACCESSORIES PART 1 GENERAL 1.1 RELATED DOCUMENTS

SECTION HANDRAILS AND RAILINGS. A. Section Cast-In-Place Concrete; coordination with substrate.

All Metals Fabrication AMF FUSION DRILLFREE ALUMINUM COMPOSITE METAL (ACM) WALL PANEL SPECIFICATION

SECTION ELASTOMERIC MEMBRANE ROOFING ADDENDUM 10 APRIL 20, 2011

A. Product Data: For each type of cold-formed steel framing product and accessory.

ROOFING EPDM ELASTOMERIC SHEET ROOFING FULLY ADHERED- CONVENTIONAL

SECTION THERMOPLASTIC MEMBRANE ROOFING. C. Flashings. D. Roofing cant strips, stack boots, roofing expansion joints, and walkway pads.

Specifications for FL-100 Soffit Panel

SECTION ELASTOMERIC MEMBRANE ROOFING

North Hanover Township School District North Hanover Township, New Jersey

SECTION (10705) EXTERIOR SUN CONTROL DEVICES

PRESTON HEALTH SERVICES ARCHITECT'S NO MITCHELL-HOLLINGSWORTH NURSING & REHAB ADPH #B

SECTION METAL WALL PANEL SYSTEM

SECTION 1 - ETHYLENE-PROPYLENE-DIENE-MONOMER (EPDM) ROOFING

SECTION SHOWER AND DRESSING COMPARTMENTS

CS-100 Guide Specifications

C. Counterflashings at roof-mounted mechanical equipment, vent stacks, curbs, and miscellaneous roof penetrations.

SECTION (formerly 05425) PRE-ENGINEERED, PRE-FABRICATED COLD-FORMED STEEL ROOF & FLOOR TRUSSES

SECTION STANDING-SEAM METAL ROOF PANEL

Hobby Parking Office HOU/ Proj./ No. 738 Houston, Texas 100% Bid and Construction Documents- Addendum #2, January 26, 2017

SECTION METAL FRAMED SKYLIGHT. A. Engineering, preparation of fabrication drawings and structural calculations for the entire skylight system.

SECTION ROOFING AND SIDING PANELS

Multi-Institutional Academic Health Science & Research Center Evansville, IN

Sheet Metal Flashing and Trim

Guideline Specifications

A/E Project No January 27, 2014

SECTION Temperature Change: 120 deg F, ambient; 180 deg F, material surfaces.

SECTION HANDRAILS AND RAILINGS. A. Section Metal Fabrications: Associated metal supports.

SECTION ROOF EDGE SAFETY RAILING SYSTEM

SECTION MODIFIED BITUMINOUS SHEET WATERPROOFING

SECTION AWNINGS

B. Samples for Initial Selection: For each type of impact-resistant wall protection unit indicated.

A. Meet at Project site <insert number> days before starting installation.

SECTION ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS

Home Depot Page 1 of 5 HDPB Humacao, PR 10/19/09

Tuscaloosa Police Station

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions

RAMAPO COLLEGE OF NEW JERSEY PHASE II HOUSING REHABILITATION C 2012

ST. JOHNS COUNTY ARCH. PROJ. NO SECTION PREFABRICATED ALUMINUM CANOPIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SECTION PANEL AND POST AND PYLON SIGNAGE. 1. Non-illuminated Panel and Post signs. 2. Internal illumination Pylon (Cabinet and Post) signs.

A. Access doors and frames are part of an access door and frame allowance.

Transcription:

Louis Armstrong New Orleans International Airport NOAB Project # 8910-01233 PART 1 - GENERAL SECTION 07 71 29 - MANUFACTURED ROOF EXPANSION JOINTS 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including NOAB General Provisions and Division 01 Specification Sections, apply to this Section. 1.2 SUMMARY A. Section Includes: 1. Bellows-type roof expansion joints. B. Related Requirements: 1. Section 06 10 00 "Rough Carpentry" for wooden curbs or cants for mounting roof expansion joints. 2. Section 07 54 19 "Polyvinyl-Chloride (PVC) Roofing" for roofing system and flat roof expansion joint. 3. Section 07 62 00 "Sheet Metal Flashing and Trim" for shop- and field-fabricated sheet metal expansion-joint systems, flashing, and other sheet metal items. 4. Section 07 72 00 "Roof Accessories" for manufactured and prefabricated metal roof curbs. 5. Section 07 95 00 "Expansion Control" for interior, and exterior expansion joints, and parking garage expansion control systems, expansion joints in metal panels, and bellows-type expansion joint associated with fixed passenger bridge walls and floor. (ADD #11) 1.3 REFERENCES A. Abbreviations and Acronyms: 1. ASTM: ASTM International. 2. UL: Underwriters Laboratories Inc. B. Reference Standards: The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only. 1. ASTM A 653: Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy- Coated (Galvannealed) by the Hot-Dip Process. 2. ASTM D 1187: Specification for Asphalt-Base Emulsions for Use as Protective Coatings for Metal. 3. ASTM D 2000: Classification System for Rubber Products in Automotive Applications. 4. ASTM D 4434: Specification for Poly (Vinyl Chloride) Sheet Roofing. 5. ASTM E 1966: Test Method for Fire-Resistive Joint Systems. 6. UL 2079: Tests for Fire Resistance of Building Joint Systems (ANSI). 1.4 PRE-INSTALLATION MEETINGS A. Pre-Installation Conference: Conduct conference at Project site. Construction Documents Manufactured Roof Expansion Joints 07 71 29 - Page 1 of 6

NOAB Project # 8910-01233 Louis Armstrong New Orleans International Airport 1. Review and finalize construction schedule and verify availability of materials, Installer's personnel, equipment, and facilities needed to make progress and avoid delays. 2. Review required submittals, submittal schedule, and status of submittal review. 3. Review performance requirements. 4. Review methods and procedures related to bellows-type roof expansion control systems installation, including manufacturer's written instructions. 5. Examine support conditions for compliance with requirements, including alignment between and attachment to structural members. 6. Review temporary protection requirements for bellows-type roof expansion control systems during and after installation. 7. Review procedures for repair of bellows-type roof expansion control systems damaged after installation. 8. Document proceedings, including corrective measures and actions required, and furnish copy of record to each participant. 1.5 ACTION SUBMITTALS A. Product Data: For each type of product. B. Shop Drawings: For roof expansion joints. 1. Include plans, elevations, sections, and attachment details. 2. Include details of splices, intersections, transitions, fittings, method of field assembly, and location and size of each field splice. 3. Provide isometric drawings of intersections, terminations, and changes in joint direction or planes, depicting how components interconnect with each other and adjacent construction to allow movement and achieve waterproof continuity. C. Samples: For each exposed product and for each color specified, 6 inches in size. 1.6 INFORMATIONAL SUBMITTALS A. Qualification Data: For Installer. B. Product Test Reports: For each fire-barrier provided as part of a roof-expansion-joint assembly, for tests performed by manufacturer and witnessed by a qualified testing agency or performed by a qualified testing agency. C. Sample Warranties: For special warranties. D. Meeting Records: Minutes of pre-installation conference. 1.7 QUALITY ASSURANCE A. Installer Qualifications: Installer of roofing membrane. 1.8 WARRANTY A. General Warranty: Special warranty specified in this Article shall not deprive Owner of other rights Owner may have under other provisions of the Contract Documents and shall be in addition to, and run concurrent with, other warranties made by Contractor under requirements of the Contract Documents. 07 71 29 - Page 2 of 6 Manufactured Roof Expansion Joints Construction Documents

Louis Armstrong New Orleans International Airport NOAB Project # 8910-01233 B. Special Warranty: Manufacturer and Installer agree to repair or replace roof expansion joints and components that leak, deteriorate beyond normal weathering, or otherwise fail in materials or workmanship within specified warranty period. 1. Warranty Period: 20 years from date of Substantial Completion, to match roofing system warranty. PART 2 - PRODUCTS 2.1 PERFORMANCE REQUIREMENTS A. General: Roof expansion joints shall withstand exposure to weather, remain watertight, and resist the movements indicated without failure, rattling, leaking, or fastener disengagement due to defective manufacture, fabrication, installation, or other defects in construction. B. Thermal Movements: Allow for thermal movements from ambient and surface temperature changes to prevent buckling, opening of joints, hole elongation, overstressing of components, failure of joint seals, failure of connections, and other detrimental effects. 1. Temperature Change: 120 deg F, ambient; 180 deg F, material surfaces. C. Fire-Test-Response Characteristics: Provide fire-barrier assemblies with fire-test-response characteristics as determined by testing identical products, per test method indicated, by UL or another testing agency acceptable to authorities having jurisdiction. Assemblies shall be capable of anticipated movement while maintaining fire rating. Fire-barrier products shall bear classification marking of qualified testing agency. 2.2 BELLOWS-TYPE ROOF EXPANSION JOINTS A. Source Limitations: Obtain bellows-type roof expansion joints approved by roofing manufacturer and that are part of roofing membrane warranty. B. Flanged Bellows Roof Expansion Joint; Roof to Wall: (ADD #11) Manufactured, continuous, waterproof, joint-cover assembly, consisting of exposed membrane bellows, laminated to flexible, closed-cell support foam, and secured along each edge to a 3- to 4-inch-wide metal flange for nailing to substrate. Provide each size and type indicated, factory-fabricated units for corner and joint intersections and horizontal and vertical transitions including those to other building expansion joints, splicing units, adhesives, and other components as recommended by roof-expansion-joint manufacturer for complete installation. Fabricate each assembly specifically for installation configuration indicated on Drawings. 1. Basis-of-Design: Subject to compliance with requirements, provide "BRJW-400 WC W/SSF-400 & RFX-4F", as manufactured by Construction Specialties, Inc., or a comparable product by one of the other named manufacturer. a. Balco, Inc. b. MM Systems Corporation. c. Watson Bowman Acme Corp. d. Johns Manville. (ADD #11) 2. Joint Movement Capability: Plus and minus 50 percent of joint size. 3. Bellows: PVC flexible membrane, nominal 60 mils thick. a. Color: Gray to match roof membrane. Construction Documents Manufactured Roof Expansion Joints 07 71 29 - Page 3 of 6

NOAB Project # 8910-01233 Louis Armstrong New Orleans International Airport 4. Flanges: Galvanized steel, 0.022 inch thick. a. Form: Formed to fit curbs as indicated on Drawings. 5. Cover Membrane: PVC flexible membrane, factory laminated to bellows and covering entire joint assembly and curbs. a. Color: Gray to match roof membrane. 6. Secondary Seal: Continuous, waterproof membrane within joint and attached to substrate on sides of joint below the primary bellows assembly. 7. Fire Barrier: Manufacturer's standard fire-resistive joint system with ratings determined per ASTM E 1966 or UL 2079 to resist spread of fire and to accommodate building thermal and seismic movements without impairing its ability to resist the passage of fire and hot gases. 8. Fire-Resistance Rating: Not less than fire-resistance rating of the roof assembly. 9. Locations: As detailed, 4/NT AT 3602, and 5/UP A 5001. Detail references are provided for Contractors convenience and may not be all inclusive. Provide expansion joint covers as indicated on Drawings. (ADD #11) C. Flanged Bellows Roof Expansion Joint; Roof to Roof: Manufactured, continuous, waterproof, joint-cover assembly, consisting of exposed membrane bellows, laminated to flexible, closedcell support foam, and secured along each edge to a 3- to 1.375-inch-wide rigid PVC flange for nailing to substrate. Provide each size and type indicated, factory-fabricated units for corner and joint intersections and horizontal and vertical transitions including those to other building expansion joints, splicing units, adhesives, and other components as recommended by roofexpansion-joint manufacturer for complete installation. Fabricate each assembly specifically for installation configuration indicated on Drawings. 1. Basis-of-Design: Subject to compliance with requirements, provide "Expand-O-Flash Expansion Joint Cover, PVC EJ", as manufactured by Johns Manville, or a comparable product by one of the other named manufacturer. a. Construction Specialties, Inc b. Balco, Inc. c. MM Systems Corporation. d. Watson Bowman Acme Corp. 2. Joint Movement Capability: Plus and minus 50 percent of joint size. 3. Bellows: PVC flexible membrane, nominal 60 mils thick. a. Color: As selected by Architect from manufacturer s full range. 4. Flanges: PVC rigid membrane, nominal 60 mils thick. a. Color: As selected by Architect from manufacturer s full range. b. Form: Formed to fit curbs as indicated on Drawings. 5. Cover Membrane: PVC flexible membrane, factory laminated to bellows and covering entire joint assembly and curbs. a. Color: As selected by Architect from manufacturer s full range. 6. Secondary Seal: Continuous, waterproof membrane within joint and attached to substrate on sides of joint below the primary bellows assembly. 07 71 29 - Page 4 of 6 Manufactured Roof Expansion Joints Construction Documents

Louis Armstrong New Orleans International Airport NOAB Project # 8910-01233 7. Locations: As detailed, 12/NT AC 4203. Detail references are provided for Contractors convenience and may not be all inclusive. Provide expansion joint covers as indicated on Drawings. (ADD #11) 2.3 MATERIALS A. Galvanized-Steel Sheet: ASTM A 653, hot-dip zinc-coating designation G90. B. PVC Membrane: ASTM D 4434, Type standard with manufacturer for application. C. Silicone Extrusions: ASTM D 2000, UV stabilized, and that does not propagate flame. D. Adhesives: As recommended by roof-expansion-joint manufacturer. E. Fasteners: Manufacturer's recommended fasteners, suitable for application and designed to withstand design loads. 1. Exposed Fasteners: Gasketed. Use screws with hex washer heads matching color of material being fastened. F. Bituminous Coating: Cold-applied asphalt emulsion complying with ASTM D 1187. PART 3 - EXECUTION 3.1 EXAMINATION A. Examine substrates, areas, and conditions, with Installer present, to verify actual locations, dimensions, and other conditions affecting performance of the Work. B. Examine roof-joint openings, inside surfaces of parapets, and expansion-control joint systems that interface with roof expansion joints, for suitable conditions where roof expansion joints will be installed. C. Verify that substrate is sound, dry, smooth, clean, sloped for drainage, and securely anchored. D. Proceed with installation only after unsatisfactory conditions have been corrected. 3.2 INSTALLATION A. General: Comply with manufacturer's written instructions for handling and installing roof expansion joints. 1. Anchor roof expansion joints securely in place, with provisions for required movement. Use fasteners, protective coatings, sealants, and miscellaneous items as required to complete roof expansion joints. 2. Install roof expansion joints true to line and elevation; with limited oil-canning and without warping, jogs in alignment, buckling, or tool marks. 3. Provide for linear thermal expansion of roof expansion joint materials. 4. Provide uniform profile of roof expansion joint throughout its length; do not stretch or squeeze membranes. 5. Provide uniform, neat seams. 6. Install roof expansion joints to fit substrates and to result in watertight performance. 7. Torch cutting of roof expansion joints is not permitted. 8. Do not use graphite pencils to mark aluminum surfaces. Construction Documents Manufactured Roof Expansion Joints 07 71 29 - Page 5 of 6

NOAB Project # 8910-01233 Louis Armstrong New Orleans International Airport B. Directional Changes and Other Expansion-Control Joint Systems: Coordinate installation of roof expansion joints with other expansion-control joint systems to result in watertight performance. Install factory-fabricated units at directional changes and at transitions between roof expansion joints and exterior expansion-control joint systems specified in Section 07 95 00 "Expansion Control" to provide continuous, uninterrupted, and watertight joints. C. Splices: Splice roof expansion joints with materials provided by roof-expansion-joint manufacturer for this purpose, to provide continuous, uninterrupted, and waterproof joints. 1. Install waterproof splices and prefabricated end dams to prevent leakage of secondary-seal membrane. D. Fire Barrier: Install fire barrier where indicated to provide continuous, uninterrupted fire resistance throughout length of roof expansion joint, including transitions and end joints. E. Metal Protection: Protect metals against galvanic action by separating dissimilar metals from contact with each other or with corrosive substrates by painting contact surfaces with bituminous coating or by other permanent separation as recommended by manufacturer. 3.3 PROTECTION A. Protect roof expansion joints from foot traffic, displacement, or other damage. B. Remove and replace roof expansion joints and components that become damaged by moisture or otherwise. END OF SECTION 07 71 29 07 71 29 - Page 6 of 6 Manufactured Roof Expansion Joints Construction Documents