SK75/100. Performance Data TOTAL HEAD IN FEET HEAD-METERS 6 SK100 SK Liters/Second Capacity-U.S. G.P.M.

Similar documents
SK50. Performance Data TOTAL HEAD IN FEET HEAD-METERS 6 SK50 SK Liters/Second Capacity-U.S. G.P.M.

SUBMERSIBLE SEWAGE EJECTOR

HUP. Performance Data. Wholesale Products Page: Section: Performance Data Dated: January RPM: 1550 Discharge: 1" Solids: 1/8" GPM: TDH:

SPX50/SPX50H. Performance Data. Wholesale Products Page: Section: Performance Data Dated: October 2007

SHEF40. Performance Data. Wholesale Products Page: Section: Performance Data Dated: April 2002 Supersedes: January 2001

HYDROMATIC SKV50 SEWAGE EJECTOR PERFORMANCE DATA SKV50. Wholesale Products Page: RPM: 1650 Discharge: 2 Solids: 2.

HYDROMATIC BV-40 SUBMERSIBLE NON-CLOG, SEWAGE EJECTOR

HPGR200 2 HP. Capacity-U.S. G.P.M.

SD/SW/VS50 SD50 SW50 VS50

HYDROMATIC W/D/V-A1 SUBMERSIBLE SUMP/EFFLUENT

G2D Series Performance Data Discharge: 1-1/4 Solids: 1/4. Wholesale Products Page: JP10075SSD-1 Section: Performance Data Dated: January, 2011

G2DT Series Performance Data Discharge: 1-1/4 Solids: 1/4. Wholesale Products Page: JP10074SSD-1 Section: Performance Data Dated: January, 2011

Pump Specifications 450 Series 1/2 hp Submersible Sump Pump

SECTION SLUDGE HOLDING TANK DECANTER PUMP

VSS S U B M E R S I B L E S E W A G E P U M P S

High Light. Motors are fully submersible Pumps can handle up to 2 spherical solids Indoor and outdoor installation Easy installation and removal

SECTION SUBMERSIBLE GRINDER PUMPS FOR WASTEWATER (LESS THAN 10 HORSEPOWER)

High Light. Motors are fully submersible Pumps can handle up to 2½ spherical solids (for 3 Discharge pumps only) Indoor and outdoor installation

Series Sump and Sewage Systems

SECTION INFLUENT EQUALIZATION TANK PUMPS

High Light. Motors are fully submersible Pumps can handle up to ½ spherical solids Indoor and outdoor installation Easy installation and removal

CONSOLIDATED EDISON COMPANY OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY DISTRIBUTION ENGINEERING ENVIRONMENTAL, HEALTH & SAFETY

Specifying Pumps Why Do Pumps Fail.

SPECIFYING PUMPS WHY DO PUMPS FAIL.

DIVISION 33 UTILITIES SECTION PACKAGED SEWAGE GRINDER PUMPING UNITS

B. Pumps are to be manufactured by Flygt Pumps. No substitutes will be considered.

A. Operation and Maintenance Data: For pumps and controls, to include in operation and maintenance manuals.

B. Wiring Diagrams: For power, signal, and control wiring.

Submersible Axial Flow Propeller Pumps

SUBMERSIBLE PUMPS FOR WASTEWATER (S-114)

SUGGESTED SPECIFICATIONS

DSC/DSCA3. EBARA Submersible Sewage Pumps Contents. Project: Model: Chk d: Date: Model

FAIRBANKS NIJHUIS SUBMERSIBLE SOLIDS HANDLING PUMPS.

FAIRBANKS NIJHUIS SUBMERSIBLE SOLIDS HANDLING PUMPS.

JDL Submersible Grinder Pumps TABLE OF CONTENTS Project: Model: Chk d: Date:

& ACCESSORIES WASTEWATERTER PUMPSUMPS -EFFLUENT PUMPS -SEWAGE PUMPS -GRINDER PUMPS -ENGINEERED GRINDERS -ENGINEERED NON-CLOGS -ACCESSORISS

SUGGESTED SPECIFICATIONS

W ARR A NTY FAIRBANKS NIJHUIS 1600 SERIES SINGLE STAGE END SUCTION PUMPS. Certified to NSF/ANSI 372.

A. This Section includes the following sump pumps and accessories, inside the building, for building storm drainage systems:

The following shall be incorporated into the Contract Documents dated 8 August 2018

SUGGESTED SPECIFICATIONS Pump Frames through 64132

SECTION PACKAGE BOOSTER PUMP STATIONS

Rugged, reliable and efficient sump pumps... your assurance of a dry basement!

SINGLE STAGE END SUCTION PUMPS AURORA Series. Distributed By: Model 3804

SECTION PACKAGED, SUBMERSIBLE SEWERAGE PUMP UNITS

SECTION PACKAGED, SUBMERSIBLE, DRAINAGE PUMP UNITS

SECTION SUBMERSIBLE END SUCTION PUMP

SECTION GENERAL MOTOR REQUIREMENTS FOR HVAC AND STEAM GENERATION EQUIPMENT

BEST ONE SUBMERSIBLE SUMP PUMPS EPA. Page Features & Applications 100 Exploded View 101 Pump & Motor Specifications 102 Selection Chart / Type key 103

Index - Section 40M Medium Sump / Drainage Pumps Bulletins 4508

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

MODEL 16ASX T/S - SPECIFICATION

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

VSS-2 ½ D HIGH HEAD SUMP PUMP FREE STANDING

Architect s Project Number of 5 Decentralized HVAC Equipment District Master Specs 2013 Edition

Wilo MC Self Priming, Horizontal Multi-Stage, High Pressure Pumps. Engineering Specification

SPECIFICATIONS - DETAILED PROVISIONS Section Progressing Cavity Pump C O N T E N T S

SERIES 800 Quality Design Features Assure Long, Trouble-Free Service

INVITATION FOR BID. April , Purchase Two Submersible Non-clog Pumps. Purchasing Depanment 4725A Moffett Road

Piranha Agitator Slurry Pumps.75 hp to 75 hp

SEWAGE GRINDER PUMPS AND PACKAGES

Project: Model: Chk d: Date: Model 32DGUII61.5S

t y p e V S A S E W A G E P U M P

DIVISION 15- MECHANICAL Section Fire Pumps

SECTION MOTORS AND PUMPS FOR PLUMBING SYSTEMS

Model T Professional Series 1/2HP 2 YEAR WARRANTY SUBMERSIBLE SUMP PUMP

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 SECTIONAL TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL 303 BEARINGS 304

YEOMANS SUBMERSIBLE SOLIDS-HANDLING WASTEWATER PUMPS YEOMANS

**** SPECIFICATIONS ****

1DIVISION 15- MECHANICAL Section Fire Pumps. A. Single Stage, Double Suction, 9100 Series Horizontal Splitcase Fire Pump (Base Mounted)

SPECIFICATIONS - DETAILED PROVISIONS Section Horizontal Centrifugal Water Pumps C O N T E N T S

C. ASSE 1013 Performance Requirements for Reduced Pressure Principle Backflow Preventers.

Section MECHANICAL EQUIPMENT. A. General: applicable provisions of the contract drawings and general conditions govern work.

DIAGRAM FOR CALCULATING PIPE SIZES, DISCHARGE VELOCITIES AND LOSS OF HEAD IN STANDARD STEEL PIPE PIPE FRICTION LOSS CHART

Replacement Wastewater Disposal System Permit Application

Goulds Two Stage, Horizontally Split Case Pump

Complete Grinder Package Offering

Max Head ' 1/ ' 115 1" FNPT 10' Manual On/Off Little Giant (5-MSPR) '

Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 202 CURVE SPEFICATIONS 203 PERFORMANCE CHART BEST ONE 204 PERFORMANCE CHART BEST ONE VOX 205

Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 202 CURVE SPEFICATIONS 203 PERFORMANCE CHART BEST ONE 204 PERFORMANCE CHART BEST ONE VOX 205

Stainless Steel with Poly Amide Fiber Reinforced Resin make NORUS pumps Lightweight with Exceptional Durability.

RAOUL WALLENBERG HIGH SCHOOL SECURITY COILING GRILLE SFUSD PROJECT NO SAN FRANCISCO UNIFIED SCHOOL DISTRICT SECTION 08330

- SPECIFICATIONS 200 PERFORMANCE RANGE and SELECTION CHART 201 TYPE KEY 202 CURVE SPECIFICATIONS 202 PERFORMANCE CURVE OPTIMA 203

special needs surface trajectory costs. High Efficiency 3. 4.

SECTION VI Duplex Lift Station with Above Grade Valve Pit

Submersible. Issue 2 / De-watering and Drainage, Sewage, Industrial and Agriculture. We have submersible pumps for every application.

SPECIAL SPECIFICATION. Automatic Pump Station

INSTALLATION INSTRUCTIONS

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 BEARINGS 302 MECHANICAL SEAL 302

PUMPS AND ACCESSORIES. Residential Fixtures Bathing Commercial Fixtures Faucets Accessories

- SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS PERFORMANCE CURVE MULTIGO PERFORMANCE CURVE MULTIGO

COMMERCIAL ITEM DESCRIPTION PUMP ASSEMBLIES, DEEP-WELL, ELECTRIC-MOTOR-DRIVEN

MODELS PH PH PH

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL and BEARINGS 303

SECTION HVAC PUMPS. A. Provide centrifugal HVAC pumps, called for in drawing schedule, and as needed for a complete and proper installation.

T Series. Self-Priming Centrifugal Pumps

Simplex Fiberglass Lift Station: Hard Piped

INSTALLATION INSTRUCTIONS

DIVISION 33 UTILITIES SECTION PACKAGED SEWAGE GRINDER PUMP UNITS

C o l u m n S u m p P u m p s

Transcription:

Performance SK75/100 RPM: 1750 Discharge: 2" Solids: 2" Wholesale Products Page: 6300-1 Section: Performance 12 40 9 30 HEAD-METERS 6 3 TOTAL HEAD IN FEET 20 10 SK75 SK100 0 0 Capacity-U.S. G.P.M. 20 40 60 80 100 120 140 160 Liters/Second 0 2 4 6 8 10 The curves reflect maximum performance characteristics without exceeding full load (Nameplate) horsepower. All pumps have a service factor of 1.2. Operation is recommended in the bounded area with operational point within the curve limit. Performance curves are based on actual tests with clear water at 70 F. and 1280 feet site elevation. Conditions of Service: GPM: TDH:

Dimensional SK75/100 Wholesale Products Page: 6300-2 Section: Dimensional 4-5/16" (109) 5-7/8" (149) 8-1/16" (204) 4-3/4" (120) 3-13/16" (96) 21-1/16" (534) 22-1/4" (565) 6-1/2" (165) All dimensions in inches. Metric for international use. Component dimensions may vary ± 1/8 inch. Dimensional data not for construction purpose unless certified. Dimensions and weights are approximate. On/Off level adjustable. We reserve the right to make revisions to our product (s) and the product (s) specifications without notice.

Electrical SK75 Wholesale Products Page: 6300-3 Section: Electrical MODEL: SK75, Sewage Ejector R.P.M. 1750 MOTOR TYPE OIL FILLED WITH AUTOMATIC RESET THERMAL OVERLOAD MOTOR PROTECTION AUTOMATIC RESET / THERMAL OVERLOAD HP VOLTAGE PHASE NEC CODE SERVICE FACTOR FULL LOAD AMPS 3/4 200 1-1 10.4 3/4 230 1-1 9.0 3/4 200 3-1 4.0 3/4 230 3-1 3.5 3/4 460 3-1 1.8 3/4 575 3-1 1.44

Electrical SK100 Wholesale Products Page: 6300-4 Section: Electrical MODEL: SK75, Sewage Ejector R.P.M. 1750 MOTOR TYPE OIL FILLED WITH AUTOMATIC RESET THERMAL OVERLOAD MOTOR PROTECTION AUTOMATIC RESET / THERMAL OVERLOAD HP VOLTAGE PHASE NEC CODE SERVICE FACTOR FULL LOAD AMPS 1 200 1-1 11.5 1 230 1-1 10.0 1 200 3-1 5.0 1 230 3-1 4.4 1 460 3-1 2.2 1 575 3-1 1.7

Technical SK75 Wholesale Products Page: 6300-5 Section: Technical MODEL: SK75, Sewage Ejector Physical : DISCHARGE SIZE 2" NPT (STANDARD) 3" NPT (OPTIONAL) SOLIDS SIZE 2" IMPELLER TYPE 2 VANE NON CLOG CABLE LENGTH 20' STANDARD PAINT PAINTED AFTER ASSEMBLY, DARK GREEN, WATER REDUCIBLE ENAMEL, ONE COAT, AIR DRIED. Temperature: MAXIMUM LIQUID 140 F MAXIMUM STATOR OIL FLASH POINT Technical : POWER CORD TYPE STW-A MATERIALS OF CONSTRUCTION MOTOR HOUSING CASING IMPELLER MOTOR SHAFT HARDWARE O RINGS MECHANICAL SEALS Standard: UPPER BEARING LOWER BEARING 416 STAINLESS STEEL STAINLESS STEEL BUNA - N CARBON / CERAMIC SINGLE ROW-BALL SINGLE ROW-BALL

Technical SK100 Wholesale Products Page: 6300-6 Section: Technical MODEL: SK100, Sewage Ejector Physical : DISCHARGE SIZE 2" NPT (STANDARD) 3" NPT (OPTIONAL) SOLIDS SIZE 2" IMPELLER TYPE 2 VANE NON CLOG CABLE LENGTH 20' STANDARD PAINT PAINTED AFTER ASSEMBLY, DARK GREEN, WATER REDUCIBLE ENAMEL, ONE COAT, AIR DRIED. Temperature: MAXIMUM LIQUID 140 F MAXIMUM STATOR OIL FLASH POINT Technical : POWER CORD TYPE STW-A MATERIALS OF CONSTRUCTION MOTOR HOUSING CASING IMPELLER MOTOR SHAFT HARDWARE O RINGS MECHANICAL SEALS Standard: UPPER BEARING LOWER BEARING 416 STAINLESS STEEL STAINLESS STEEL BUNA - N CARBON / CERAMIC SINGLE ROW-BALL SINGLE ROW-BALL

Specification SK75/100 Wholesale Products Page: 6300-7 Section: Specification SUBMERSIBLE SEWAGE EJECTOR MODELS: SK75 and SK100 1.01 GENERAL Contractor shall furnish all labor, materials, equipment and incidentals required to provide (Qty.) submersible centrifugal sewage ejector pump(s) as specified herein. The pump models covered in this specification are the SK75, and SK100. The pump furnished for this application shall be MODEL as manufactured by Hydromatic Pumps. 2.01 DESIGN CONDITIONS Each pump shall be rated H.P., volts, phase, hertz and operate at RPM. 3.01 OPERATING CONDITIONS The pump shall deliver U.S. GPM/LPS at feet/meters TDH, and handle a inch solid. The curve submitted for approval shall state, in addition to head and capacity performance, solid handling capability, amp rating, and design impeller diameter. 4.01 CONSTRUCTION Each pump shall be of the sealed submersible type, incorporating features normally found in pumps furnished for the residential market. These features include: 1. The pump volute, motor, and seal housing shall be high quality gray cast iron, ASTM A-48, Class 30. 2. The pump inlet shall be open and clear, without screening to provide access for sewage and solids. 3. All external mating parts shall be machined and Buna N, O-Ring sealed. 4. All fasteners exposed to the pumped liquid shall be 300 series stainless steel. 5. All power cords shall be water resistant UL or CSA approved, with double insulation, and sized as a function of Amp. draw. 5.01 MOTOR AND SHAFT The stator, rotor and bearings shall be mounted in a sealed submersible type housing. Single phase motors shall be split phase or capacitor start with centrifugal switch. Three phase motors shall be Polyphase. Full Load and Locked Rotor Amps as well as Start and Run winding resistance shall be tabulated for each pump. 6.01 BEARINGS, SHAFT AND MECHANICAL SEAL An upper bushing bearing and lower thrust bearing shall be required. The upper bearing shall be brass while the lower bearing is a single row ball. They are both permanently and continuously lubricated and cooled by the dielectric oil which fills the motor housing. The motor shaft shall be stainless steel and sealed from the pumped liquid with a carbon ceramic mechanical seal.

Specification SK75/100 Wholesale Products Page: 6300-8 Section: Specification 7.01 IMPELLER The Impeller shall be high capacity, two vane, non-clog design with pump out vanes on the back side. These vanes wash out grit and stringy material that will damage the shaft and mechanical seal. 8.01 AUTOMATIC CONTROL All single phase pumps should be capable of automatic operation. 9.01 MANUAL CONTROL The Single Phase SK75 and SK100 pumps are not supplied with any type of automatic control. A super or double wide angle piggy-back float switch can be supplied and fitted to these pumps. 10.01 PAINTING All cast iron parts shall be painted before assembly with a water reducible alkyd air dried enamel. The paint shall be applied in one coat with a minimum thickness of 3 to 4 mils. 11.01 TESTING All pumps shall be individually tested to include the following: 1. The pump and power cord shall be visually inspected for imperfections, cuts or nicks. 2. The pump shall have a ground continuity check and the motor chamber shall be Hi-potted to test for moisture content and/or insulation defects. 3. The motor and volute housing shall be pressurized and a 10 second air leak decay test run. 4. Oil is added, and the pump is run. Voltage and current are monitored visually, electronically, and the tester listens for any noise or malfunction.