Tactile Walking Surface Indicators (TWSIs): Design Considerations

Similar documents
Description Accessibility Standards. AODA OBC 2015 Ramps

Section 1 OBC FADS /13 Access to Parking Areas

Kinesik Engineered Products Inc. 4/22/16 1

Description Accessibility Standards. University of Toronto

Small. Application. Regulation Reference: (see page 23 for link to the regulation)

Accessibility for Ontarians with Disabilities Act (AODA), 2005

T1. Steps and stairs general

Accessibility. Design Standards. The path to an accessible future

Americans with Disabilities Act Accessibility Survey

Heading Ramps on Recreational Trails

Curb Ramps [ 4.7.3] [ 4.7.2; 4.8.2; 4.1.6(3)(a)] [ 4.3.7] ADA Accessibility Survey Instructions Curb Ramps Page 1 of 6

Universal Design and Accessibility Guideline for Site Plan Control 2016 Edition

Report Title: Testing Different Materials for Tactile Walking Surface Indicators Pilot Project Evaluation Report

A117.1 Chapter 3 Building Blocks

Design Aid for Barrier-Free Accessibility in Existing Buildings

Accessibility Design Standards

PROPOSED CHANGE TO THE 2012 BUILDING CODE O. REG. 332/12 AS AMENDED

Florida Accessibility Code for Building Construction

ADA Checklist for Polling Places

ADA Checklist for Polling Places

ADA Checklist for Polling Places

RYA Sailability Brief Guides

Audits. Peter J. Monahan. Engineers Ireland Seminar: Urban Street Design for Engineers

Table of Contents. April 2016 Page 1

Accessible Public Spaces Design Standards

SPECIAL PROVISIONS - SP2014 BOOK Page 1 October 8, 2013

Annotated Accessibility Changes to the 2012 Ontario Building Code, as Amended by Ontario Regulation 368/13

Accessibility Design Guidelines

(D) Surface Slope Bituminous patch in front of the truncated domes must not exceed 5% measured perpendicular to the flow line or edge of roadway.

Work Group Item Stairways serving an occupant load of less than 50 shall have a width of not less than 36 inches (914 mm).

1 Exam Prep Florida Building Code-Accessibility Edition Tabs and Highlights

Project: MOE FLS Reference Designs for Standard Classroom Upgrade 2-storey Nelson Block

CITY OF OCEANSIDE. Single Family Dwelling Stairways/Guards. Informational Bulletin

DEPARTMENT OF PUBLIC SAFETY AND CORRECTIONS. Public Safety Services ADA-ABA COMMENT ASSISTANCE GUIDE

Disability Access Audit Checklist

PERMEABLE PATH PAVING

New York City RS 6.1 Photoluminescent Exit Path Markings

Flagstones + Paving + Kerbs + Steps Specification Guide. Steps STEPS AG.UK.COM

SITE ACCESSIBILITY AND PARKING

OAAC Members of the Oshawa Accessibility Advisory Committee

FEDERAL TRANSIT ADMINISTRATION. ADA: Key and New Rail Station Checklist Based on USDOT Final Rule, Effective November 29, 2006

CITY OF DANA POINT SITE ACCESSIBILITY AND PARKING B103 SITE INTRODUCTION

RESIDENTIAL STAIRWAYS, HANDRAILS,

10. Transportation Facilities.

From the ADA and ABA Accessibility Guidelines for Buildings and Facilities

ICC CODE CORNER 2012 IFC Code & Commentary

(d) Metal buildings used for industrial uses are not exempt from additional landscape standards as required in Section (e).

Site Accessibility Survey & Transition Plan

EGRESS AZMIR SULTANA NICOLAS MIMU SAKUMA EDWIN VEGA CHAMORRO

Priority 2 Access to Goods & Services

Disability Standards for Accessible Public Transport 2002

PROPOSED CHANGE TO THE 2012 BUILDING CODE O. REG. 332/12 AS AMENDED

CITY OF LOS ANGELES Department of Building and Safety Disabled Access Section RESIDENTIAL ACCESSIBILITY PLAN REVIEW LIST

Access/Egress Statement

Standard for Bleachers, Folding and Telescopic Seating, and Grandstands

Your 3 Step Guide to selecting the correct stair nosing

DEPARTMENT OF ARCHITECTURE ABUBAKAR TAFAWA BALEWA UNIVERSITY, BAUCHI ARC 624: ADVANCED BUILDING SERVICES LESSON 2: CONVEYANCE SYSTEMS IN BUILDINGS

*Universal Design Audit Checklist

Expanding Your Market

Construction Overview. Section 5 Construction Considerations. Curb Ramp Construction. Curb Ramp Construction. Overview.

Florida Accessibility Code for Building Construction

ARTICLE 987. PD 987. PD 987 was established by Ordinance No , passed by the Dallas City Council on June 14, (Ord.

Adult Family Home Inspections

SUPPLEMENTARY ACCESSIBILITY REQUIREMENTS

Approved Document. Protection from falling, collision and impact. The Building Regulations 2010

EGRESS CHAPTER ,500 3 Over 2,500 4 OCCUPANT LOAD REQUIRED MEANS OF EGRESS

Why do we need to learn about Stairs

2009 IBC Section 1024 Approved Luminous Egress Path Markings

CITY OF ANN ARBOR, MICHIGAN Public Services Area/Project Management Unit 301 E. Huron Street P.O. Box 8647, Ann Arbor, Michigan 48107

Intro. ADA Operations Contact Info

Steps And Stairs Installation Steps In Wall - Option 1 Steps In Front of Walls - Option 2 Steps In Wall; 10 (25cm) Tread - Option 3 Step Parallel to

Accessible Means Of Egress

311.7 Stairways Width Headroom. Exception: Walkline Stair treads and risers Tread depth.

2015 IBC Accessible Means of Egress

Stair Nosing Australia

4. If more than 5 entrances to the building then 50% must be barrier free leading to the outside sidewalk or ramp.

Proudly Made in the U.S.A.

Annual Accessibility Status Report

Steps And Stairs Installation Option 1 - Steps In Wall Option 2 - Steps With Plant Space Option 3 - Steps In Front of Walls Option 4 - Steps Along

Intro. ADA Operations Contact Info

-=== Building Safety Departnlent 'Neil Avenue, Room 202 Cheyenne, WY Phone: (307) Fax: (307) RAMPS

CITY OF LOS ANGELES Sidewalk Repair Program. Amber Elton, PE

Testing and Evaluation of Detectable Warning Systems 2005 NESMEA Meeting

The following are details of the code requirements of the 2015 International Residential Code for single-story decks.

STAGE 9 ARCHITECTURAL GUIDELINES. TAMANI COMMUNITIES #200, Ave SE, Calgary, AB, T2Z 3X1

DIVISION 4.3 CITY OF SARNIA CONCRETE SIDEWALKS, CURBS AND DRIVEWAYS STANDARDS 2018

BUILDING/FACILITY ACCESSIBILITY CHECKLIST. Lessee. Lessor

Sovereign Pocket Design Essentials

QUEEN ALEXANDRA COMMUNITY CENTRE

2009 IBC/IFC Photoluminescent Signs & Pathway Marking Systems Frequently Asked Questions

Railway Applications Design for PRM use - Equipment and Components On Board Rolling Stock Part 3: Clearways and Internal Doors

Stair Nosing Australia

Appendix GENERAL INFORMATION TECHNICAL INFORMATION BUILDING CODES INDEX

CHAPTER 10 MEANS OF EGRESS

STAIRWAYS, HANDRAILS, AND GUARDRAILS (RESIDENTIAL)

Civic Center Renovation News

GENERAL NOTES FOR COMMERICAL ACCESSIBILITY

B. All roadways per the American Association of State Highway and Transportation Officials, (AASHTO) Standards for local roads.

Loading Dock Buyers Guide

SECTION 11 Architectural and Nonstructural Elements Field Investigation

Transcription:

1

Presentation Overview Presentation can be downloaded from the DesignABLE website; www.designable.net/oaa2016.html or Go to DesignABLE home page www.designable.net Click pull down menu Go to Resources page Choose 2016 OAA Conference 2

Presentation Overview 1. Terminology and Acronyms 2. How people use TWSIs 3. Legislative requirements in Ontario 4. Canadian and International Standards 5. Installation Principles 6. Materials and Installation Options 7. Application Exercise 3

Who am I? Who are we? 4

1 Terminology and Acronyms TAI/TWSI Attention Pattern Guiding Pattern Colour Contrast Detectable LRV Luminance 5

1 Terminology and Acronyms TAI/TWSI Attention Pattern Guiding Pattern Colour Contrast Detectable LRV Luminance TAI Tactile Attention Indicator (OBC) TWSI Tactile Walking Surface Indicator (AODA and ISO) 6

1 Terminology and Acronyms TWSI Attention Pattern Guiding Pattern Colour Contrast Detectable LRV Luminance 7

1 Terminology and Acronyms TWSI Attention Pattern Guiding Pattern Colour Contrast Detectable LRV Luminance 8

1 Terminology and Acronyms TWSI Attention Pattern Guiding Pattern Colour Contrast Detectable LRV Luminance 9

1 Terminology and Acronyms TWSI Attention Pattern Guiding Pattern Colour Contrast Detectable LRV Luminance 10

1 Terminology and Acronyms TWSI Attention Pattern Guiding Pattern Colour Contrast Detectable LRV Luminance 11

2 How people use TWSIs Use residual sight Use a mobility aid long cane guide dog sighted companion 12

2 Residual Sight Luminance Contrast 13

2 Mobility Aids 14

2 How people use TWSIs 15

3 Legislative Requirements in Ontario Ontario Building Code Attention TAI/TWSIs required at Exit stairs (3.4.6.1.(2)) and 9.8.9.6.(4))* Entry to vehicle routes where no curb or other element provide to separate people from vehicles (3.8.3.2.((1)) Curb Ramps (3.8.3.2.((2)) Platform edges (3.8.3.17 (1)) Pool Decks (3.11.3.1 (14)) *Part 9 requires TAI/TWSIs on all stairs except stairs serving a single dwelling unit or service space 16

3 Legislative Requirements in Ontario AODA Accessibility Standards for the Design of Public Spaces TAI/TWSIs required at Exterior stairs not regulated by the OBC (80.25) Curb ramps not regulated by the OBC (80.26) Depressed curbs at pedestrian crossings (80.27) 17

3 Legislative Requirements in Ontario OBC Technical Requirements for TAI/TSAIs At the top of stairs starting one tread depth back from the edge of the top of the stair At the leading edge of stair landings with a door Specific location criteria not provided for curb ramps or depressed curbs At platform edges AODA DOPS 300 610 mm deep At least 610 mm deep At the top of all flights of stairs Extend full width of stair starting one tread depth back from the edge of the top of the stair Extend full width of curb ramp / depressed curb, commencing 150 200 mm back from the curb edge At platform edges Comply with clauses 4.1.1+2* of ISO 23599 (truncated domed surface) *Note that the colour contrast requirements from the ISO standards are not referenced Must have tactile elements raised above adjacent surfaces Must have high tonal contrast to adjacent surfaces 18

4 Canadian/International Standards TAI/TWSI requirements have been harmonized in 2015 updates 19

4 Attention TAI/TWSIs Top diameter of truncated domes or cones mm Spacing mm 12 42 to 61 15 45 to 63 18 48 to 65 20 50 to 68 25 55 to 70 20

4 Guidance TAI/TWSIs Top width of flat topped elongated bars mm Spacing mm 17 57 to 78 20 60 to 80 25 65 to 83 30 70 to 85 21

5 Shorelines versus TAI/TWSIs? A shoreline is a continuous edge (curb, wall, etc.) that a person with vision loss using a long cane can safely use for directional guidance Unobstructed shorelines are preferable to TAI/TWSI guidance paths TAI/TWSI guidance paths should be considered where shorelines do not exist (such as across a plaza or concourse) 22

5 Shorelines versus TAI/TWSIs? 23

5 Guidance Path Installation Principles Always use the K.I.S.S. Principle K Keep I It S Simple S Stupid Conceptual design of a guidance route system for Rotterdam Central Station (Source: PBT consult) Limit the use of tactile guiding paths to primary routes and elements 24

5 Guidance Path Installation Principles Straight guidance paths are preferred 300 600 mm wide Maintain 600 mm clear space on either side of path Minimise number of turns Use 90 turns wherever possible Perpendicular approach to elements Terminate 600 mm from wall or other elements 50% LRV Contrast 25

5 Guidance Path Installation Principles Lead people to the usable parts of elements (elevator call button, stair handrail, etc.) Use 600 x 600 mm attention surfaces at decision making points Keep guiding paths clear of obstructions (street furniture, overhanging tree branches, etc.) 26

5 Guidance Paths 27

6 Materials and Installation Options Cast in Place Systems Precast concrete pavers Composite panels Cast iron systems Porcelain stoneware tiles Flexible polymer tiles Other Systems 28

6 Materials and Installation Options Cast in Place Systems Precast concrete pavers Composite panels Cast iron systems Porcelain stoneware tiles Flexible polymer tiles Other Systems Source: Tile Tech Pavers Source: Pavestone 29

6 Materials and Installation Options Cast in Place Systems Precast concrete pavers Composite panels Cast iron systems Porcelain stoneware tiles Flexible polymer tiles Other Systems Source: Armor Tile 30

6 Materials and Installation Options Cast in Place Systems Precast concrete pavers Composite panels Cast iron systems Porcelain stoneware tiles Flexible polymer tiles Other Systems Source: Duralast 31

6 Materials and Installation Options Cast in Place Systems Precast concrete pavers Composite panels Cast iron systems Porcelain stoneware tiles Flexible polymer tiles Other Systems Source: Urban Access Solutions 32

6 Materials and Installation Options Cast in Place Systems Precast concrete pavers Composite panels Cast iron systems Porcelain stoneware tiles Flexible polymer tiles Other Systems Source: Urban eon Tile 33

6 Materials and Installation Options Cast in Place Systems Precast concrete pavers Composite panels Cast iron systems Porcelain stoneware tiles Flexible polymer tiles Other Systems Machined Stone Machined Granite 34

6 Materials and Installation Options Surface Applied Systems Composite systems Plastic/Metal Stud/Bar systems (often called discrete systems) Thermoplast/epoxy systems 35

6 Materials and Installation Options Surface Applied Systems Composite systems Plastic/Metal Stud/Bar systems (often called discrete systems) Thermoplast/epoxy systems Source: Armor Tile 36

6 Materials and Installation Options Surface Applied Systems Composite systems Plastic/Metal Stud/Bar systems (often called discrete systems) Thermoplast/epoxy systems Source: Urban Access Solutions 37

6 Materials and Installation Options Surface Applied Systems Composite systems Plastic/Metal Stud/Bar systems (often called discrete systems) Thermoplast/epoxy systems Source: PBT consult 38

7 Let s try it: Design Study 39

Learning Objectives Understand the purpose for and key characteristics of TWSI s Identify the design principles appropriate for the design of TWSI systems 40

Learning Objectives Identify commonly used TWSI types, TWSI materials and installation options Develop a design for an effective TWSI system for a small building 41

Thank you! Bob Topping DesignABLE Environments 905 278 0665 bob.topping@designable.net www.designable.net 42