Recovery Boiler Corrosion Chemistry

Similar documents
Finding the Root Cause is Critical

RECOVERY BOILER WATER AND FIRE SIDE DAMAGE MECHANISMS April 2015 Western Canada BLRBAC. Craig Reid, M.A.Sc., P.Eng. Acuren Group Inc., Richmond, B.C.

PROCESS CHANGES AND CORROSION OF MATERIALS IN RECOVERY BOILERS

Problems with Deposits

Capital Equipment Preservation -Corrosion Control

Introduction to Kraft process - Black liquor and The black liquor recovery boiler

UPDATED CASE STUDY OF FIRESIDE CORROSION MANAGEMENT IN AN RDF FIRED ENERGY-FROM-WASTE BOILER

Corrosion Fatigue. PPChem. PPChem 101 BOILER AND HRSG TUBE FAILURES LESSON 2: INTRODUCTION FEATURES OF FAILURES IDENTIFICATION

Western BLRBAC Review/Refresher of Tappi Water Quality Guidelines and Contamination Procedures for mill boilers operating on high purity water

"Kraft Recovery Boilers" By T. N. Adams, W. J. Frederic, T. M. Grace, M. Hupa, K. Iisa, A. K. Jones, H. Tran

View from the Penthouse

Corrosion in Black Liquor Pyrolysis and Combustion Gas Environments

Corrosion in Black Liquor Pyrolysis and Combustion Gas Environments

Low-temperature corrosion in fluidised bed combustion of biomass

The Institute of Paper Science and Technology

Stress Corrosion Cracking in Pulp and Paper Systems

1. Scaling. H.O.: H-5/21, KRISHNA NAGAR, DELHI Tel.: , Fax:

Kraft Liquor Corrosion

Corrosion in biomass-fired installations

XXL size recovery boilers present status and future prospects

View from the Penthouse

Process Recovery Boilers. Reliable and efficient steam production for the pulp and paper industry

Corrosion in GASCO Habshan CBA Units and its mitigation

GLIMPSES OF IMPROPER WATER CHEMISTRY IN A SUBCRITICAL PULVERIZED COAL FIRED BOILER AT A THERMAL POWER PLANT

Intergranular Corrosion (IGC)

RB Reduction Degree Step change adjustment tests. Jeff Butler Product Manager

Results of declining coal quality on boiler remnant life T Vosloo/K McIntyre

BOILER WATER TREATMENT TECHNOLOGY. DSS HEAD OFFICE - SERPONG May 2008

Operational Challenges in Energy and Chemical Recovery in Kraft Pulp Mills

Combatting HCl Acid-Dewpoint Corrosion at The Geysers. John Farison Calpine Corporation

A Review of Sulfide Smelting Process Gas Handling Systems

PULP AND PAPER RESEARCH INSTITUTE OF CANADA INSTITUT CANADIEN DE RECHERCHES SUR LES PÂTES ET PAPIERS. Red Hot Video of Combusting Liquor & Smelt

Corrosion Issues In Black Liquor Gasifiers

September 2010 API Recommended Practice

Summary of Session 2. Corrosion in Waste Fired Systems. A. L. Plumley, session chairman Combustion Engineering, Inc.

Steam Cycle Chemistry in Air-Cooled Condensers. NV Energy ACC User s Group * November 12-13, 2009 Andrew Howell * Xcel Energy

Laser Cladding: a New Technology for Corrosion and Erosion Protection of Boiler Tubes

CHAPTER 1 INTRODUCTION

API 571 Damage Mechanisms Affecting. Fixed Equipment in the Refining Industry WHO SHOULD ATTEND TRAINING METHODOLOGY

Effects of Co-Firing Biomass with Coal

Black Liquor Sprays. Rick Wessel, Ph.D. Advisory Engineer The Babcock & Wilcox Company. Outline

AIRHEATER FOR INDUSTRIAL BOILERS

Solutions. for Severe Corrosion

short name: NR* technical product sheet created :57 1/10 seamless tube EN tol. acc. EN/ISO 1127 NR ,0 0,075 4,0 0,125

For Condensing Economizers ENBRIDGE MAY Topics

novel polymer technology for boiler deposit control

Could biomass boilers be operated at higher steam efficiencies (higher temps.)?

Leakage Failure Analysis in a Power Plant Boiler

Factors Influencing Materials Selection in Condensing Economizers

High Power Generation from Recovery Boilers - What Are the Limits?

The Effect of Heat Flux on the Steam Oxidation Kinetics and Scale Morphology of Low Alloy Materials

View from the Penthouse

Hastelloy C-2000 (UNS N06200)

Sulfur Unit Equipment Problems and Low Silicon Carbon Steel Corrosion Gerald W. Wilks Lemont Refinery CITGO Petroleum

Materials for elevated temperature heat exchangers in reactors

Insititue of Paper Science and Technology Central Files CORROSION CONTROL ANNUAL RESEARCH REVIEW HANDOUT BOOK

Relationship Between Design and Materials for Thermal Power Plants. S. C. Chetal

Fireside 258. Fireside 258 is very stable and will neither outgas, nor cause skin irritations like many other high temperature coatings.

Incoloy Alloy 800H/800HT (UNS N08810/088011)

EVALUATION OF A CHEMICAL CLEANING FORMULATION FOR THE STEAM GENERATOR OF NUCLEAR POWER PLANTS

Boiler Tube Life Management

Valmet Online Learning

RECOVERY BOILER GENERATING BANK TUBE THINNING David G. Stasuk, P.Eng. President Stasuk Testing & Inspection Ltd. Burnaby, B.C.

Alloy 20 29Ni-20.5Cr-3.5Cu-2.5Mo A351 CN7M J Mo 20Cr-18Ni-6.5Mo-N-Cu A351 CK3MCuN J93254

ATI 332 ATI 332. Technical Data Sheet. Stainless Steel: Austenitic GENERAL PROPERTIES TYPICAL ANALYSIS PHYSICAL PROPERTIES

E-BRITE E-BRITE. Technical Data Sheet. Stainless Steel: Superferritic GENERAL PROPERTIES PLANAR SOLID OXIDE FUEL CELLS CHEMICAL COMPOSITION

API 571 CORROSION & MATERIALS PROFESSIONAL CERTIFICATION PREPARATION PROGRAM

API 571 CORROSION & MATERIALS PROFESSIONAL CERTIFICATION PREPARATION PROGRAM

Fossil Materials and Repair - Program 87

THE INSTITUTE OF PAPER CHEMISTRY, APPLETON, WISCONSIN IPC TECHNICAL PAPER SERIES NUMBER 237 VAPORIZATION FROM ALKALI CARBONATE MELTS JOHN H.

Fossil Materials and Repair - Program 87

Corrosion. Cause of Corrosion: Electrochemical Mechanism of Corrosion (Rusting of Iron)

MANAGING TUBE METAL WASTAGE IN RDF-FIRED BOILERS AT ELK RIVER STATION

Boiler Energy Efficiency & Overview of Economizers

Downsizing a Claus Sulfur Recovery Unit

Analysis of Tube Failure in Water Tube boiler

High Temperature Corrosion in Gasifiers

High Temperature Effects on Vessel Integrity. Marc Levin, Ayman Cheta Mary Kay O Connor Process Safety Center 2009 International Symposium

ATI 201 HP /ATI 201L HP

Diagnosing Boiler Tube Failures Related to Overheating

DATA SHEET ZERON 100 UNS S32760 THE GLOBAL LEADER IN SPECIALTY ALLOYS ALLOYS AND PROCESSING

DATA SHEET ZERON 100 UNS S32760 THE GLOBAL LEADER IN SPECIALTY ALLOYS

Oxidation And Degradation Products Of Common Oxygen Scavengers

Caustic Gouging. PPChem. PPChem 101 BOILER AND HRSG TUBE FAILURES LESSON 5: INTRODUCTION TYPICAL CHARACTERISTICS OF DAMAGE

Non-Metallic Expansion Joint

Results are presented in Table 1. The tube was fabricated from a Type 347 and no unusual conditions were noted.

Safety Information Bulletin Airworthiness SIB No.: R1 Issued: 13 September 2018

- Identify inspection finding that "rise to the top", or are most common to units across the fleet

[Mishra*, 5(3): March, 2016] ISSN: (I2OR), Publication Impact Factor: 3.785

Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard

NEW GENERATION OF TUBE SURFACE TREATMENTS HELP IMPROVE EFW BOILER RELIABILITY

OVERHEATING AND FUEL ASH CORROSION FAILURE OF BOILER TUBES IN SWCC POWER PLANTS - Some Case Studies 1

A REVIEW OF EXPERIENCES WITH AL-6XN AND ZERON 100 IN AIR POLLUTION CONTROL EQUIPMENT. *Devin M. Wachowiak and Jason D. Wilson

HRSG Inspection Planning Guide

NICKEL CHROMIUM ALLOYS

Recovery & Utility Management

Heat Treatment of Tubes for Condenser, Feedwater Heater, and Shell & Tube Heat Exchangers

These elements are in carbon steels in minimal amounts, usually less than 1%.

Sulfur Area Materials of Construction

A STUDY OF CASTING CHARACTERISTICS FOR DIE-CAST ALUMINUM ALLOY

Transcription:

Recovery Boiler Corrosion Chemistry Sandy Sharp and Honghi Tran SharpConsultant University of Toronto Pulp and Paper Centre Symposium on Corrosion in Pulp and Paper Mills and Biorefineries, RBI at Georgia Tech., November 14, 2014 Introduction The different chemistries in different regions of a recovery boiler each cause their own forms of corrosion and cracking Understanding the origin of the corrosive conditions enables us to operate a boiler so as to minimize corrosion and cracking select materials and designs that minimize corrosion in new or rebuilt boilers 2 1

Metal Loss, mm/y 11/13/2014 Lower furnace tubes: sulfidation Reducing lower furnace environment contains insufficient p O2 to form protective oxide on CS tubes (ΔG only slightly ve), but sufficient p H2 S and p CH3 SH to form FeS (ΔG ~ -250 kj/mol S 2 ) FeS is a highly defective semiconductor and allows rapid diffusion (corrosion) at rates that increase with temperature 3 Lower furnace tubes Corrosion (sulfidation) rate of CS tubes increases with surface temperature Corrosion rates become impractically high in RBs operating at > about 62 bars (~900 psi) 2 1 0 450 250 550 300 Temperature, C, F 650 350 400 600 800 1000 1500 Operating Pressure, psig 4 2

Alloying CS with Cr produces corrosion scales with lower diffusion coefficients Even in low p O2 of lower furnace, adding > 18% Cr forms protective Cr 2 O 3 (ΔG ~-950 kj/mol O 2 ) Cr additions can be supplied by Moberg, 1974 Composite tubes Chromizing Thermal spray coatings (each brings challenges) 5 Studded Tubes: elevated temperatures and fatigue stresses Hottest studs burn away on fireside and accelerate waterside corrosion on waterside S contamination makes flash welds brittle Studding does not reduce corrosion rate D.C. Bennett, Paper 20.3 at 2008 TAPPI Engineering Conference 6 3

Corrosion in molten smelt Rates up to 1.3 m/y (50 /y) on CS if metal reaches smelt temperature Keep spouts cool (BLRBAC) 22 C (40 F) can spout life x 4 Chromize or clad spouts with SS SharpConsultant. May not be reproduced without permission from Sandy Sharp 7 Smelt Spouts are vulnerable to thermal fatigue cracking Avoid operating practices that produce severe thermal cycling 8 4

Composite air port tubes: unusual chemistry causes localized corrosion of SS NaOH can condense where [CO 2 ] and [SO x ] are low and dissolve the otherwise protective Cr 2 O 3 Cr 2 O 3 (s) + 4NaOH(l) +3/2 O 2 (g) 2Na 2 CrO 4 (s) 2H 2 O(g) SS corrodes faster (0.25-1.25 mm/y) than exposed CS (0.08-0.2 mm/y), producing expanding but not deepening bald spots Smelt oxidation exotherm causes furnace side thinning 9 Cracking in composite floor tubes Temperature cycles leave SS layer in tension SCC initiates in concentrated alkaline sulfide solution (dissolved smelt) during shutdowns (160-200 C), propagates by thermal fatigue Most cracks occur near spout openings where ΔT and T are highest Floor tube cracks stop at SS/CS interface 10 5

Thermal fatigue cracking in composite air port tubes Caused by Thermal stresses from smelt washing against tubes and from attachment welds Tubes often contain residual tensile stresses from bending Cracks in cladding can propagate into CS Improve operation to minimize thermal stresses Minimize thermal strains by using Alloy 825-clad tubes 11 Upper waterwalls, roof and furnace screen Addition of combustion air raises p O2 at tube surfaces in upper furnace steel tubes form protective iron oxides (Fe 2 O 3 over Fe 3 O 4 ) ΔG ~ -450 kj/mol O 2 CS corrodes 2-3x slower than in lower furnace No need to alloy with Cr 12 6

3 Corrosive local chemistries in upper waterwalls, roof and furnace screen 1. Low load with high Na 2 SO 4 /Na 2 CO 3 ratio: Na 2 SO 4 (s) + SO 3 (g) + H 2 O(g) NaHSO 4 (s,l) Risk of bisulfate pitting is highest in low pressure boilers, with low bed temperatures, low solids firing, high sulfur input and intense sootblowing 13 3 Corrosive local chemistries in upper waterwalls, roof and furnace screen 2. High load reducing environments under carryover particles containing partly-burned liquor have high p H2 S and produce lower furnace sulfidation 3. Cold-side pitting on tangent tubes Minimize time in contact with wet poultice of acidic furnace dust 0.025 mm (0.001 ) per day at ambient temperature 14 7

Generating bank Environment oxidizing and relatively cool Corrosion rates generally low (~ 0.025 mm/y, 0.001 /y) CS tubes designed with low or zero corrosion allowance Potential causes of thinning Near-drum thinning Erosion by water droplets in sootblower steam Low MT NaHSO 4 deposits Caustic SCC where tube-to-drum seals leak and concentrate alkaline boiler water chemicals 15 Superheater Highest metal temperatures, but high p O2 forms surface oxides Tolerable corrosion on CS tubes to 400 C (750 F): Fe 3 O 4 Add Cr (T11,T22) for temperatures to 500 C (932 F): (Cr,Fe) 3 O 4 Use stabilized γ SS for highest temps: Cr 2 O 3 Solid 347H SS or composite (310/T22) tubes if concerned about risk of SCC 16 8

Weight Loss, mg 11/13/2014 Corrosion accelerates when fireside deposits are molten 50 40 Type 310SS coupons in temperaturecontrolled probe in operating RB superheater 30 20 10 0 350 400 450 500 550 600 700 800 900 1000 1100 Temperature, C, F 17 Corrosion accelerates at melting temperature of fireside deposit (2) Corrosion rate accelerates at temperatures within ~50 C of FMT Corrosion rate increases x 4 when temperature increases 3 C, (5 F) across deposit MT So, beware of partial pluggage, especially with process conditions that produce low MT SH deposits (high Cl, high K, high Na/S ratio, low bed temperature) 18 9

Superheater Pitting 19 Fatigue cracking of generating bank and pendant tubes at restraints Caused by vibration; not related to chemistry Fireside fatigue cracks initiate at nodes where vibration clamps restrain pendant tubes beside welds attaching tubes in a panel where generating bank tubes enter drum where economizer tubes welded into header Small leaks can thin large areas on adjacent tubes and produce fish-mouth ruptures To minimize tube vibration, avoid excessive sootblowing 20 10

Fatigue cracking of pendant tubes beside restraining welds 21 Economizer, precipitator and stack Flue gases are oxidizing and cool; corrosion damage is rare Some RBs suffer dew point corrosion, sootblower erosion, or outside-in fatigue cracking 22 11

Dew point corrosion in economizer, precipitator, stack Below water dew point (68-77 C, 155-170 F): moisture condenses flue gases, e.g. SO x, NO x dissolve in condensate ph falls to 3.0-2.5 CS corrodes at up to 0.76 mm/y, 0.030 /y 23 Waterside stress-assisted corrosion Waterwall tubes Superheater tube Slow-growing internal corrosion fatigue fissures near external attachment welds 24 12

Waterside stress-assisted corrosion fissures Slow-growing fissures propagated by startup/shutdown stresses (only) when boiler water has low ph, high O 2 Waterside oxide fractured by tensile thermal strains within ~2 cm of external attachment weld Similar corrosion fatigue observed in deaerators and at SH attachment welds Little effect on burst strength 25 Waterside flow-accelerated corrosion Rounded cavities produced by dissolution of waterside oxide in fast-flowing water Occurs only on CS (<1% Cr); in water flowing >2.5-3 m/s; where direction changes produce turbulence; at ph 7-9.5; when [O 2 ] < 20 ppb, when T=100-250 C (212-480 F) 26 13

CONCLUSION Understanding the chemical conditions that cause corrosion and the mechanical conditions that cause cracking enables us to reduce corrosion and inhibit cracking by addressing the underlying cause of each type of damage 27 28 14