CYCLIC BEHAVIOUR OF SANDWICH CONCRETE BEAM UNDER FLEXURAL LOADING

Similar documents
Behaviour of Sandwiched Concrete Beam under Flexural Loading Firdaus #1, Rosidawani #2

In-plane testing of precast concrete wall panels with grouted sleeve

EXPERIMENTAL INVESTIGATION OF PRECAST CONCRETE BEAM TO COLUMN CONNECTIONS SUBJECTED TO REVERSED CYCLIC LOADS

CHAPTER 3 BEHAVIOUR OF FERROCEMENT HOLLOW SLABS

SHEAR STRENGTHENING OF RC BRIDGE PIERS BY STEEL JACKETING WITH EXPANSIVE CEMENT MORTAR AS ADHESIVE

MECHANICAL CHARACTERIZATION OF SANDWICH STRUCTURE COMPRISED OF GLASS FIBER REINFORCED CORE: PART 1

Hybrid-steel concrete connections under reversed cyclic loadings

Experimental and analytical study of the steel-concrete-steel beam under flexural behavior

TESTS ON AN INTERIOR REINFORCED CONCRETE BEAM-COLUMN JOINT. R. Park*, L. Gaerty**, and E.C. Stevenson***

REVIEW PAPER ON USAGE OF FERROCEMENT PANELS IN LIGHTWEIGHT SANDWICH CONCRETE SLABS

ISSN: Page 14

NEW COMPOSITE CONSTRUCTION OF HYBRID BEAMS COMBINING STEEL INVERTED T-SECTION AND RC FLANGE

RESILIENT INFRASTRUCTURE June 1 4, 2016

PERFORMANCE OF AN INNOVATIVE PRE-CAST COLD-FORMED STEEL AS COMPOSITE BEAM WITH SINGLE AND DOUBLE C- CHANNELS

EXPERIMENTAL RESULTS

The Recent Research on Bamboo Reinforced Concrete

CHAPTER 5 BEHAVIOUR OF BEAM-COLUMN JOINT UNDER CYCLIC LOADING

Thin-Walled Steel Enclosed Lightweight Foamcrete: A Novel Approach to Fabricate Sandwich Composite

BEHAVIOUR OF SHEAR CONNECTORS IN COMPOSITE CONSTRUCTION

Composite Beams of Cold Formed Steel Section and Concrete Slab

PERFORMANCE OF EXTERIOR PRECAST UNDER CYCLIC LOADING. R. Vidjeapriya & K.P. Jaya Anna University, Chennai , India 1.

Basic quantities of earthquake engineering. Strength Stiffness - Ductility

World Engineering Congress 2010, 2 nd 5 th August 2010, Kuching, Sarawak, Malaysia Conference on Engineering and Technology Education

Seismic Behavior of Low Strength RC Columns with Corroded Plain Reinforcing Bars

STRUCTURAL BEHAVIOUR OF SHORT-SPAN REINFORCED CONCRETE BEAMS WITH FOAMED CONCRETE INFILL

Tests of R/C Beam-Column Joint with Variant Boundary Conditions and Irregular Details on Anchorage of Beam Bars

SEISMIC RESPONSE OF LINEAR, FLANGED, AND CONFINED MASONRY SHEAR WALLS

Code No: R Set No. 1

DURABILITY PERFORMANCE OF EPOXY INJECTED REINFORCED CONCRETE BEAMS WITH AND WITHOUT FRP FABRICS

EXPERIMENTAL STUDY ON SEISMIC BEHAVIOR OF REINFORCED CONCRETE COLUMNS UNDER CONSTANT AND VARIABLE AXIAL LOADINGS

Experimental Study on the Behaviour of Plastered Confined Masonry Wall under Lateral Cyclic Load

An Experimental Study on the Effect of Opening on Confined Masonry Wall under Cyclic Lateral Loading

Level 6 Graduate Diploma in Engineering Structural analysis

AN INVESTIGATION OF SEISMIC RETROFIT OF COLUMNS IN BUILDINGS USING CONCRETE JACKET

BEHAVIOUR OF FRP REINFORCED CONCRETE UNDER SIMULATED SEISMIC LOADING

Research on Weight Reduction of PC Composite Members Using Ultra High Strength Fiber Reinforced Cementitious Composites (UFC)

Experimental investigation of the use of CFRP grid for shear strengthening of RC beams

ABC-UTC. Research Progress Report (Feasibility Study) Title: Alternative ABC Connections Utilizing UHPC. March, 2017

Shear Strength Behaviour of Steel Truss Embedded in Flexural Plastic Hinge Zone of Reinforced Concrete Beam Subjected to Reversed Cyclic Loading

Effect of Flange Width on Flexural Behavior of Reinforced Concrete T-Beam

Lap Splices in Tension Between Headed Reinforcing Bars And Hooked Reinforcing Bars of Reinforced Concrete Beam

FLEXURAL IMPROVEMENT OF PLAIN CONCRETE BEAMS STRENGTHENED WITH HIGH PERFORMANCE FIBRE REINFORCED CONCRETE

PRESTRESSED CONCRETE STRUCTURES. Amlan K. Sengupta, PhD PE Department of Civil Engineering Indian Institute of Technology Madras

SEISMIC RETROFIT OF BEAM-COLUMN JOINTS WITH FRP SHEETS

STUDY ON SEISMIC BEHAVIOR OF RECYCLED CONCRETE FRAME JOINTS UNDER LOW CYCLIC LOAD

BEHAVIOR OF INFILL MASONRY WALLS STRENGTHENED WITH FRP MATERIALS

Ultimate strength prediction for reinforced concrete slabs externally strengthened by fiber reinforced polymer (FRP)

STRUCTURAL BEHAVIOUR OF SINGLY REINFORCED OPS BEAMS

THE EFFECT OF ADDITIONAL MATERIALS CONCRETE USING THE SAND WITH HIGH LEVELS MUD ON DEFLECTION AND FLEXIBLE STRESS ON CONCRETE BEAMS

Question Paper Code : 11410

EXPERIMENTAL STUDY ON SEISMIC BEHAVIOR OF REINFORCED CONCRETE CORE WALL

FAILURE MODE AND STRENGTH CHARACTERISTICS OF NON-GRADED COARSE AGGREGATE CONCRETE BEAMS

Earthquake-Resistant Coupling Beams without Diagonal Reinforcement

EXPERIMENTAL INVESTIGATION ON COMPOSITE SLAB

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 1, No 3, 2010

Experimental Study on behavior of Interior RC Beam Column Joints Subjected to Cyclic Loading P.Rajaram 1 A.Murugesan 2 and G.S.

EFFECT OF VENEER JOINT REINFORCEMENT ON BRICK TIE EMBEDMENT

Fagà, Bianco, Bolognini, and Nascimbene 3rd fib International Congress

Behavior of Skew Reinforced and Prestressed Concrete Composite Decks. Hany Ahmed Ahmed Dahish, Ahmed Foad El-ragi and Alaa Aly El-Sayed

INTERNATIONAL JOURNAL OF APPLIED ENGINEERING RESEARCH, DINDIGUL Volume 1, No 2, 2010

Flexural Behaviour of External Reinforced Concrete Beams

Finite Element Analysis of RC Beams Strengthened with FRP Sheets under Bending

UHPC Connection of Precast Bridge Deck

STRENGTH AND BEHAVIOUR OF GEOPOLYMER CONCRETE BEAMS

Ductile moment-resisting connections in glulam beams

Available online at ScienceDirect. Procedia Engineering 125 (2015 )

Seismic Performance of Hollow-core Flooring: the Significance of Negative Bending Moments

SEISMIC STRENGTHENING OF INFILLED RC FRAMES BY CFRP

TESTS ON A POST TENSIONED MOMENT RESISTING CONNECTION FOR PRECAST CONCRETE STRUCTURES

Experimental Study on Wall-Frame Connection of Confined Masonry Wall

EFFECT OF SHORT METALLIC FIBERS IN MIXED REINFORCED HRFRC BEAMS : AN EXPERIMENTAL STUDY

High Performance and Efficiency of Joints in Precast Members

SEISMIC RETROFIT OF BEAMS IN BUILDINGS FOR FLEXURE USING CONCRETE JACKETING

BENDING CAPACITY OF COMPOSITE COLD- FORMED STEEL AND CONCRETE OF A STRIP PLATE STRUCTURE

IN THE APPLICATION INVENTOR(S) ABUL KALAM AZAD AND IBRAHIM YAHYA AHMED HAKEEM FOR ULTRA-HIGH PERFORMANCE CONCRETE REINFORCEMENT BARS

STRENGTHENING OF UNBONDED POST-TENSIONED CONCRETE SLABS USING EXTERNAL FRP COMPOSITES

Performance of Reinforced Concrete Beams with Implanted Columns

The Open Civil Engineering Journal

INFLUENCE OF PRSTRESS LEVEL ON SHEAR BEHAVIOR OF SEGMENTAL CONCRETE BEAMS WITH EXTERNAL TENDONS

CHAPTER 4 PUNCHING SHEAR BEHAVIOUR OF RECYCLED AGGREGATE CONCRETE TWO WAY SLABS

COMPARATIVE STUDY OF BEAMS BY USING DIFFERENT TYPES OF RETROFITING TECHNIQUES

Experimental research on reduced beam section to concrete-filled steel tubular column joints with RC slab

INFLUENCE OF SHEAR REINFORCEMENT ON RESIDUAL LOAD CAPACITY OF RC BEAMS WITH CORROSION

HRC T-Headed Bars Advantages for the user

BEHAVIOR OF HIGH STRENGTH REINFORCED CONCRETE SLENDER COLUMN UNDER BIAXIAL LOADING

Experimental Study of Reinforced Concrete (RC) Beams Strengthened by Carbon Fiber Reinforced Polymer (CFRP): Effect of Beam Size and Length of CFRP.

STUDY AND PERFORMANCE OF HIGH STRENGTH CONCRETE

SEISMIC UPGRADING OF EXISTING RC ORDINARY MOMENT RESISTING FRAMES USING FRPS

Seismic performance of RC frames with concentric internal steel bracing

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 3, No 2, 2012

CRACKING BEHAVIOR AND CRACK WIDTH PREDICTIONS OF CONCRETE BEAMS PRESTRESSED WITH BONDED FRP TENDONS

International Journal on Emerging Technologies 5(2): (2014) ISSN No. (Print) : ISSN No. (Online) :

UPGRADING SHEAR-STRENGTHENED RC BEAMS IN FATIGUE USING EXTERNALLY-BONDED CFRP

GFRP HOLLOW-CORE REBARS FOR CONCRETE BEAMS

On Improved Performance Of Eccentrically Braced Frames With Replaceable Shear Link

FLEXURAL AND SHEAR STRENGTHENING OF REINFORCED CONCRETE STRUCTURES WITH NEAR SURFACE MOUNTED FRP RODS

STRUCTURAL LAB. FACILITY AT IITG IN THE DIRECTION OF TRADITIONAL/LOCAL HOUSING

Upgrading the shear strength of non-ductile reinforced concrete frame connections using FRP overlay systems

Punching shear behavior of Lightweight foamed RC slabs

SEISMIC EXPERIMENTAL RESEARCH OF CONCRETE FILLED STEEL TUBE COLUMNS-CONCRETE COMPOSITE SHEAR WALL

Transcription:

Journal of Built Environment, Technology and Engineering, Vol. 3 (September) ISSN 128-13 217 CYCLIC BEHAVIOUR OF SANDWICH CONCRETE BEAM UNDER FLEXURAL LOADING Firdaus Department of Civil Engineering Universitas Bina Darma, 3264, Palembang, Indonesia Email: firdaus.dr@gmail.com, Tel: +62812-214478 Ishak Yunus Department of Civil Engineering Universitas Bina Darma, 3264, Palembang, Indonesia Email: ishak_yunus@binadarma.ac.id, Tel: +62812-789275 Rosidawani Department of Civil Engineering Universitas Sriwijaya, 3136, Palembang, Indonesia Email: rosidawani@gmail.com, Tel: +62812-7889319 ABSTRACT The theories relating to the structural analysis shown that the part of the concrete structural elements whose strength works maximally in resisting the bending force is in the compressive region. Therefore, it is inefficient if the core part of the concrete is made of the same type of concrete. The sandwich concrete consisting of different layers between the center (core) concrete and the surface (skin) layers became the basic idea in this study. With this sandwich concrete, we can streamline the design of structural elements made of concrete by using high strength concrete in the skin layer while the ordinary and lightweight concrete in the core layer. The core layer is made of lightweight concrete with the compressive strength of 3 MPa. It is sandwiched between two skin layers made of normal concrete with compressive strength 5 MPa. The connector is applied to connect different composite layers in order to transfer the longitudinal shear force in the beam. Moreover, the cyclic loading test was conducted on three kinds of beam specimen with dimensions of 21 mm in length, 1 mm width and depth of 2 mm. Differences in the cyclic flexural behavior of sandwich beams with respect to the connector and compressive strength of the core layers were monitored in terms of cracking patterns, stiffness and strength degradation, energy dissipation and ductility. The obtained results showed that the cyclic load of the beam determined the degradation of stiffness and strength in every cyclic due to the slip at the lower load (pinching effect). The connector and the compressive strength of the center layer of the beam established the increasing of dissipation energy. Observation on the ductility of the flexural beams shows that ductility response of the beams is specified by the loading systems, the connector in the middle part of the concrete beams, and the compressive strength of the central layer concrete. Keywords: Cyclic, Sandwich Concrete, Dissipation-Energy, Ductility. INTRODUCTION The sandwich beam consists of two thin, rigid and strong layers of solid material separated by a thick layer made of a low-density material, which has a lower stiffness and strength than the two other layers (Callister, 1997). The two thin layers are functioned as skin layers and the thick mid layer is known as a core (Figure 1). In accordance with the concrete material, it is efficient if the core part of the concrete is made of different type of concrete, since the theories relating to the structural analysis shown that the part of the concrete structural elements whose strength works maximally in resisting the bending force is in the compressive region. This concept is being the basic idea to create the sandwich concrete consisting of different layers between the center (core) concrete and the surface (skin) layers. Proportionally, an efficient sandwich beam occurs when the core weight of the sandwich is approximately equal to the total weight of the skin layer (Corden, 199). Sandwich structures combine the superiority of the materials used as its layers, the high-strength and stiffness of the skin layers and the low density of the concrete core layer (Jones, R.M, 1975). As it is known that the aggregate has the largest proportion in the concrete mix (Neville, A.M, 2), replacing the conventional aggregate with artificial lightweight aggregate (ALWA), will reduce the total weight of the concrete and structure will become lighter as well. Although the lightweight concrete also has low stiffness as its weaknesses, it is suitable to be used as the core layer in the sandwich concrete beam. Hence, this combination will produce a strong and stiff yet lightweight sandwich concrete. In most cases, an efficient sandwich structure can be obtained if the weight of its core is equal to the total weight of its skins (Corden, 199). Using lightweight aggregate in concrete member produced an ideal situation in material saving since it will reduce the weight of the structure without having to compromise on its strength and serviceability (Vimonsatit, V, 212). Using the sandwich concrete can streamline the design of structural elements made of concrete by using high-strength concrete in the outermost layer (skin) while the center (core) is filled with lightweight normal strength concrete. The core layer must be stiff enough under shear loading, such that when the sandwich structure bends the skin layers do not slide against each other and prevent the lost 29

Journal of Built Environment, Technology and Engineering, Vol. 3 (September) ISSN 128-13 217 of the composite effect. Moreover, the core layer must be stiff enough such that the skin layers stay level under bending load to against the delamination (Van Straalen, 1998). Meanwhile, the connector is applied to connect different composite layers in order to transfer the longitudinal shear force in the beam. The combination of this high-strength concrete, lightweight concrete, and the connector among the layers will be assigned on how the behavior cyclic of this sandwich beam. MATERIAL AND METHODS This study is based on bending cyclic test of the sandwich concrete in a laboratory. The specimens used the following specifications: the skin layers are precast concrete (normal weight concrete (NWC)) with the depth of 6 cm and the core layer (lightweight concrete (LWC)) with the depth of 8 cm cast between the two concrete layers of precast age 4 days. Figure 1: Sandwich Concrete Layers A. Specimen Preparation Basically, the sandwich beam is laminated of three layers concrete. Those layers consist of the top and bottom layers as the skin layers and the core layer in the middle. This laminated layer beam will produce a very complex mechanical behavior under external and other types of loading. This paper presents three kinds of specimens which consist of: - N-L-N non connector beam - N-L-N connector beam - N-N-N connector beam. N-L-N and N-N-N show to differentiate between high strength normal weight concrete and low strength lighweight concrete respectively for the core layer. Those specimens represent the using of connector or not as well. Figure 2: The Sandwich Concrete Beam Figure 2 shows the dimension of the specimen which consists of 6 x 1 x 21 mm in size for the surface layer, and 8 x 1 x 21 in size for the core layer. The two surface layers concrete was made of the precast concrete. After 4 days the core layer in the middle of the part of the sandwich is an in-situ cast placed between the two surface layers. The number of longitudinal reinforcement bar for each beam is 3 with the diameter of 6 mm. Since the roughness effect is negligible, the inner surface of the precast concrete that will touch the core layer was not roughened. 3

Journal of Built Environment, Technology and Engineering, Vol. 3 (September) ISSN 128-13 217 B. Materials The beams were constructed with the skin layer of high strength concrete for the normal weight with an average 28-day concrete compressive strength of 5 MPa and the core layer of normal strength concrete for the lightweight concrete with that of 3 MPa. The concrete compressive strength was based on the average values from tests performed on at least three 15x 3 mm cylinders from each concrete batch on the day of testing the beam under the standard rate of loading (.25 MPa/s). The mix design of normal weight high strength concrete was done in accordance with the guidelines specified by ACI 211.4R-93. While the lightweight normal strength concrete was batched based on ACI 211.2-91. The natural fine aggregates used were Galunggung sand collected from Galunggung mountain. The natural coarse aggregate with 9.8 mm of maximum size sourced from Banjaran, West Java. ASTM Type 1 Tiga Roda Portland cement and ASTM C618 class F fly ash with the density of 2.31 gr/cm 3 from PLTU Suralaya, West Java were used as the filler of the concrete. The chemical additive, namely, sikament NN from PT SIKA Nusa Pratama was applied as the superplasticizer in the normal weight high strength concrete. All the main ingredient of the normal weight high strength concrete was used in the lightweight normal strength aggregate. The different material was the lightweight aggregates, which are the artificial lighweight aggregate with 12.54 mm of maximum size from Cilacap, West Java. The yield strength, f y of 39 MPa was used as the longitudinal reinforcement bar and the connector bar as well. The mix proportions are given in Table 1. Table 1: The Mix Proportions of Each Layer of Sandwich Comcrete Beam Composition Normal Weight Concrete (kg) Lightweight Concrete (kg) CEMENT 411.1 42.9 FLY ASH 72.6 FINE AGGREGATE 574.3 564.9 NATURAL COARSE AGREGATE 964.8 - LIGHWEIGHT COARSE AGGREGATE 552.5 WATER 213.6 226.5 SUPERPLASTISIZER 3.2 - WATER CEMENT RATIO.4.5381 C. Instrumentation The figure 3 showed the instruments which are used in the sandwiched beam testing in this study consist of: a. Reinforcement bar and concrete strain measurement b. Deflection measurement apparatus c. Slippage measurement apparatus d. Rotation measurement apparatus e. Load Cell Figure 3: The Position of The Measurement Apparatus in Sandwich Concrete Beam Testing Actuator Inclinometer Steel SG Slip LVDT Concrete SG Steel SG Displacement LVDT 47 47 47 47 188 31

Journal of Built Environment, Technology and Engineering, Vol. 3 (September) ISSN 128-13 217 D. Beam Loading Figure 4 shows the setting of sandwich concrete beam testing. Each of 28 days old beam specimens was tested by laying horizontally in a loading frame. The pin and roll supports were conducted at the ends of the beam as the simply supports. Moreover, the additional supports were applied for the cyclic testing. Cyclic loading was performed by using the loading history based on displacement control (Figure 5). Figure 4: The Setting of Sandwich Concrete Beam Testing Figure 5: The Loading History of Cyclic Testing RESULTS AND DISCUSSION The flexural strength of the beam was computed in each loading stage referred to testing data. This Figure 6 presents the envelope curve of the hysteresis curve which shows the load versus deflection in the middle of the span beam. That each graph shows the comparison of the cyclic behavior of the specimens. The N-N-N reached the biggest maximum deflection among others before it collapsed. The bigger deflection the higher ductility of the specimen reached. Obviously, each specimen explains the stable condition until the ultimate deflection. 32

Load (kn) Journal of Built Environment, Technology and Engineering, Vol. 3 (September) ISSN 128-13 217 Figure 6: The Envelope Load Deflection Curves -2-15 -1-5 5 1 15 N-L-N nonconnector N-L-N connector N-N-N connector 2 1 8 6 4 2 Deflection (mm) -2-4 -6-8 -1 A. Cracking Pattern 1. N-L-N Nonconnector Beam Cyclic loading was applied on this N-L-N non-connector beam. Fine cracks began to appear in the center of the bottom surface the beam leading upward at the first cycle compression load. These cracks closed again when the load reversed to the pull, so it was visually invisible. Inversely, when the tensile load applied, the fine cracks were shown in the center span of the top surface of the beam. The bending moment that caused the initial cracks on the beams is 1.993 knm in compression direction and 1.335 knm in tension direction. In the second cycle of the loading step, other cracks occurred at the one-third of beam span. The bending moment that caused the longitudinal reinforcement to yield is 4.56 knm in compressive direction and 3.784 knm intention direction. At the later loading stage both on the tension and the tensile direction, the cracks were concentrated in the middle of the span and increased in width a perpendicular direction to the beam axis. In the second cycle of the 6th step of cyclic loading, the sloping cracks near the load point started on the top surface of the concrete. These cracks were then wider and caused a buckling effect on the top surface layer. These flexural cracks were continued with the tilted cracks caused a shear collapse. The maximum bending moment that can be supported by the beams is 4.94 knm in compressive direction and 4.56 kn.m in tension direction. 2. N-L-N connector Beam In this N-L-N connector beam the behavior of crack pattern was identical with the N-L-N non connector. The bending moment that caused the initial cracks on the beams is 2.496 knm in compressive direction and 1.922 knm in tension direction while which that caused the longitudinal reinforcement to yield is 4.23 knm in compressive direction and 3.854 knm in tension direction. The propagation of crack pattern was started with the fine cracks at the first cycle of the first loading step and wider at the next step. The cracks were concentrated at the mid span of the beam. Those cracks continued as the flexural cracks until the beam reached the collapse patterned perpendicular to the beam axis. The maximum bending moment that can be carried by the beams is 4.315 knm. 3. N-N-N connector Beam At the first loading step, this N-N-N connector beam also shown the same behavior of crack pattern. The cracks were also concentrated at the middle of the span and continued to grow in width. The cracks that occurred the beam collapsed caused the top surface layer of the beam was broken. Those cracks patterned perpendicular to the beam axis are the flexural cracks. The bending moment that caused the initial cracks on the beams is 3.346 knm in compressive direction and 3.346 knm in tension direction. The bending moment that caused the longitudinal reinforcement to yield is 4.225 knm in the compressive direction and 4.83 knm in the tension direction. The maximum bending moment that can be generated by the beams is 5.635 knm. B. Stiffness and Strength Degradation Each specimen was tested using a displacement control method. The number of steps used in the test based on the value of displacement which was increased sequentially. Each step of this test was applied in 2 cycles. Based on the test results seen that there was a change in the value of strength and stiffness between cycles at each loading step, as well as the changes in the strength and the stiffness values among loading steps. Figure 7 below shows the change in between the strength and the stiffness of each specimen. 33

Stiffness Degradation Percentage of Stiffness Degradation (%) Strength Degradation (kn) Percentage of Strength Degradation(%) Stiffness Degradation Percentage of Stiffness Degradationo (%) Strength Degradation (kn) Percentage of Strength Degradtion(%) Journal of Built Environment, Technology and Engineering, Vol. 3 (September) ISSN 128-13 217 4 3 2 1-1 -2-3 -4.5.4.3.2.1. -.1 -.2 -.3 -.4 -.5 Figure 7: The Strength and Stiffness Changes in Each Cycle of the Loading E 1 2 4 6 8 (a) E 1 2 4 6 8 (c) 4 3 2 1-1 -2-3 -4 4 3 2 1-1 -2-3 -4 E 1 2 4 6 8 (b) E 1 2 4 6 8 (d) Figures 7 (a) and (b) show the change of strength between two cycles in each step loading. Those are described that the strengths which are tended to be a decline in each cycle are different. The percentage of decreasing between cycles is below 2% except for N- L-N Non-Connector specimen which reaches up to 29.43%. The use of the connector results in different strength change between cycles in each loading step. The beam with connector seems to be more stable than those without a connector. The same trend also occurs in the change of stiffness between two cycles in each step loading. Figures 7 (c) and (d) clearly explain that the stiffness change tends to be a decline with no more than 15%, except for N-L-N Non Connector specimen which reached up to 29.57%. The connector of the beam also resulted in the differences in stiffness changes between cycles in each loading step as can be seen from those graphs. The stiffness between cycles tends to be more stable at the higher load step, as seen from the smaller percentage of stiffness change. 6 4 2-2 -4-6 6 4 2-2 -4-6 Figure 8: The Strength and Stiffness Changes in Each Loading E-1 1-2 2-4 4-6 6-8 (a) E-1 1-2 2-4 4-6 6-8 (c) 25 2 15 1 5-5 -1-15 -2-25 25 2 15 1 5-5 -1-15 -2-25 E-1 1-2 2-4 4-6 6-8 (b) E-1 1-2 2-4 4-6 6-8 (d) 34

Energy Dissipation (knmm) Journal of Built Environment, Technology and Engineering, Vol. 3 (September) ISSN 128-13 217 The strength changes among the loading steps are clearly shown in Figure 8 (a) and (b). A large increase in strength is imposed upon loading through the elastic condition with a relatively low strength value. At the next loading step, it becomes quite stable with a relatively small load burden. The strength begins to decline at the last step. The N-L-N Non Connector specimen only lasts up to the 4th loading step while other specimens are able to withstand up to a higher loading step with relatively stable conditions. Otherwise, the stiffness value of the specimen is a degradation significantly as the loading passes through the elastic state. Figures 8 (c) and (d) show that at a higher step the decrease in stiffness continues with the value tends to decrease. Based on all comparisons of strength and stiffness it can be concluded that the decrease of stiffness degradation occurs when the load is lower. This is caused by the slip condition experienced by the beam causing the pinching effect. While post peak load changes are relatively stable in all specimens. C. Ductility Based on the cyclic test, the ductility value can be determined by comparing the deflection occurring in the ultimate condition to that of at yield state. Table 2 shows the differences of the three beam specimens in this cyclic test. The N-N-N Connector specimen yields the highest ductility value of 15,578. The use of connector in the sandwich beam proved to affect the resulting ductility, seen from the results obtained that the ductility of the N-L-N Connector test specimen is higher than N-L-N Non connector. Specimen N-L-N NON CONNECTOR N-L-N CONNECTOR N-N-N CONNECTOR P push Table 2: Ductility of the Beam Yield Condition Yield Load (kn) P pull I II I II Deflection (mm) Ultimate Condition Ultimate Load (kn) Deflection (mm) Ductility y P push u u / y 8.63 7.7 8.5 7.89 5 6.1 34 6.8 5.31 4.89 4.9 4.3 5 9.43 67.9 13.418 7.12 6.96 7.12 6.99 5 11.99 78.79 15.758 D. Energy Dissipation Figure 9: Energy Dissipation in Each Cycle of The Cyclic Test 5 4 3 2 1 E.1 E.2 1.1 1.2 2.1 2.2 4.1 4.2 6.1 6.2 8.1 8.2 N-L-N Connector 4 2 51 28 135 123 353 294 551 474 772 659 N-N-N Connector 5 2 63 37 165 143 468 422 764 733 166 897 35

Energy Dissipation Cumulatif (knmm) Journal of Built Environment, Technology and Engineering, Vol. 3 (September) ISSN 128-13 217 Figure 1: Cumulative Energy Dissipation of The Cyclic Test 5 4 3 2 1 E.1 E.2 1.1 1.2 2.1 2.2 4.1 4.2 6.1 6.2 8.1 8.2 N-L-N Connector 4 6 57 85 22 343 696 99 1541 215 2787 3445 N-N-N Connector 5 7 7 18 273 415 884 136 269 282 3868 4765 The calculation of energy dissipation was determined on N-L-N connector beam and N-N-N connector beam based on cyclic test result. Figure 9 shows the time history of the energy dissipation response in each cycle to the boundary state. While Figure 1 presents the cumulative energy dissipation value to the ultimate state of the two beam specimens. The energy decline in the second cycle at each loading stage which is shown in Figure 9 is due to the degradation of the stiffness of the structure according to the one shown in Figure 7 (c) and (d). This is due to the slip condition of the pinching effect. Figure 1 presents that the N-N-N connector beam produces higher energy dissipation. It is concluded that the combination of lightweight concrete materials used in the sandwich concrete layers results in more ductile behavior based on the ability of the beam to dissipate the energy. CONCLUSION This research is limited to the cyclic behaviour of sandwich concrete beam under flexural loading. The results give significant contribution in accordance with the basic theory of cyclic behaviour from the sandwich concrete concept, which can be drawn: a. The bonding between the two different concrete layers which is set by the connector heavily influenced the composite behavior of the beams. The beam with the connector leads the better cyclic behaviour. b. The cyclic load of the beam determined the degradation of stiffness and strength in every cyclic due to the slip at the lower load (pinching effect). c. The connector and the compressive strength of the center layer of the beam established the increasing of energy dissipation. The N-N-N Connector beam produced the higher energy dissipation. d. The cyclic loading observation on the flexural beams shows that the ductility response is specified by the connector in the middle part of the concrete beams, and the compressive strength of the core layer of the concrete. e. These research results will be the basic theory of the sandwich concrete which will be developed to the next other project researchs. REFERENCES ACI (1991). Standard Practice for Selecting Proportions for Structural Lightweight Concrete ACI 211.2.91, ACI Manual of Concrete Practice Part 1, American Concrete Institute, Detroit. ACI (1993). Guide for Selecting Proportions for High Strength Concrete with Portland cement and Fly Ash - ACI 211.4R-93, ACI Manual of Concrete Practice Part 1, American Concrete Institute, Detroit. Callister, W.D. (1997). Materials Science and Engineering An Introduction, John Wiley & Sons, Inc. Corden, J. (199). Honeycomb Structure, in Engineered Materials Handbook. ASTM Int., Ohio, pp: 721-728. Jones, R. M. (1975). Mechanics of Composite Materials. McGraw-Hill. Neville, A.M. (2). Properties of Concrete. Prentice Hall.Van Stralen Vimonsatit, V., Wahyuni, A.S., & Nikraz, H. Reinforced Concrete Beams with Lighweight Concrete Infill. Scientific Research and Essays, 7(27), 237-2379. 36