Instruction Manual HT 24 BM-D2400 Homogenizer

Similar documents
Operation Manual INCUBATOR2 Dual Dry Block Incubator

Operation Manual. Dual Temperature Digital Dry Block Incubator. Catalog No. INCUBATOR Rev C. April 2016

64C Amplification Block. Instruction Manual

CR-1730R. CappRondo Refrigerated Centrifuge Operating Manual

Wealtec Corp. E-Centrifuge Microcentrifuge Operation Manual. Version 3.0 Item # *This instrument is intended for laboratory use only

Rook Currency Counter

Blender. Instruction Manual

ecosphere water purifier 3in1 USER MANUAL

DJ Switch 10F V2 ORDERCODE 50365

Laboratory Refrigerator Model: ,-01,-02,-03,-04,-05,-06,-07,-08, -09,-10,-11,-12,-13,-14

OPERATION MANUAL. A220 Arc Welding Machine. Serial Number: Where Purchase: Date of purchased:

Moving money forward UV MG

Professional Weighing Equipment. K-Series Scales. Operation Manual KHR 6000 KHR 123 KHR 502 KHR 3001

nual k Excella E-1 Open Air Shaker N) manual New Brunswick Excella E-1 Open Air Shaker Operating manual

Operational Manual. Spectrophotometer Model: SP-830 PLUS. Metertech Inc. Version 1.07

Keep your head out of the gas. When you are welding, air extractor should be used to prevent inhalation of gas.

Gelovit 200 en English

S-1100 Series Currency Counter Operating Manual. Models S-1100, S-1115 and S-1125

Magner /35-3 Series Currency Counter. Operator's Manual

Table of contents. 1. Introduction

Haygain HG-600 Hay Steamer. User Manual

Haygain HG-2000 Hay Steamer. User Manual

Imperial Series. Model IMP-425/525/625/825/1000AP IMD-425/525/625/825/1000AP IMP-1025/1200/1500/2000AP IMD-1025/1200/1500/2000AP

BakeMax Dough Mini Moulder BMMDM02

DMC When Accuracy Counts

Operation Manual Smart R17

POWER PINNER BENCH HAND WELDER 7250 OPERATOR S MANUAL

Haygain HG-ONE Hay Steamer. User Manual

TA Instruments Packing the DHR Instrument

Safety Precautions. 3. Cabinet Assembly 4. Operating buttons / functions.5-6. Machine Operation

Installation Guide. Single AC or Dual AC Sump Pump Installation. 1 AC Primary Pump or 2 AC Pumps with Auxiliary Alternator

S-1000 Mini Series Currency Counter Operating Manual. Models S-1000, S-1015 and S-1025

WARNING! Read all the information contained in this Manual, before you begin using the Equipment.

Automatic Key Cutting Machine - CONDOR XC-007 CONDOR. Automatic Key Cutting Machine XC-007. User Manual V1.2

Personal Massager PL021. Operating Manual

XSTi Standby UPS. 400VA, 600VA, 800VA Models. User & Installation Manual

Operation Manual. Professional Weighing Equipment. MRB Series Mid Resolution Balances. MRB 500g MRB 1200g MRB 2500g MRB 6000g MRB 10000g

Horizontal Belt Stacker

S-1600 Series Currency Counter Operating Manual. Models S-1600, S-1615 and S-1625 Including "V" Series

2200-Lb. Semi-Electric Stacker OWNER S MANUAL

Operating Manual. Professional Weighing Equipment. TB Series intelligent weighing machine. Touch Color Screen HIGH RESOLUTION BALANCE

ISSUED: OCT. 11, 2005 REVISED: JAN. 1, 2007 HOSHIZAKI REFRIGERATED GLASS MERCHANDISER KD-90D MODEL INSTRUCTION MANUAL

C60 Standby UPS. 800VA Models. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

Instruction Manual ODY-1765

CN Series P.N , Software rev. T 8, Revision A1- July 2014

AHP WELDS USER MANUAL

Operating Instructions

AP5K-C Precision AC Double-Pulse Spot Welding Machine User s Manual Shenzhen Will-Best Electronics Co., Ltd

Owner s Manual.

AL-SUS STEP LIFT USER GUIDE. AL-SUS Technologies Pte Ltd 1st August 2017

FSW10 Pallet Wrapping Machine OPERATION MANUAL

UCTION MANUAL. 4G Platypus Jar Tester

VARIO XX28 Stainless Steel Time And Temperature Controlled Electric Model

VARIO XX28 Stainless Steel Time And Temperature Controlled Electric Model

Whitening Lamp. Instructions for use. flaesh.com

Drone Overview. Quick Start Guide. BACK 10 - Drone Status Indicator FRONT. 1 - Drone Overview. 4 - Disclaimers, Warnings & Guidelines

1. About this edition of the operating manual

MMA ARC/TIG WELDING MACHINE INTIG

RATSTM REDUCED ATMOSPHERE TESTING SYSTEM INSTRUCTION & SERVICE MANUAL

Haygain HG-600 Hay Steamer. User Manual

USER S OPERATING AND INSTRUCTION MANUAL

! CAUTION: Read and follow these instructions.

Popcorn Machine. Instruction Manual

RUBBER BANDS 500 USER'S MANUAL. IGS Audio Igor Sobczyk 3 Maja 76d, Mysłowice, Poland ph:

Service Manual For the E Ride 26

Royal Sovereign RSL 2701 Laminator

HOBO Plug Load Logger (UX ) Manual

INSTRUCTION & REFERENCE MANUAL Model no. ODY-1720NX

AEX30 Stella Tabletop Pasta Extruder

HRO-50 Water Purifier

LASER GUIDED PARKING SYSTEM

Operations Manual. For Research Use Only. PH: EM: WEB:

LOW PROFILE FLOOR SCALE

The Biology CRO. Protein Staining System. For electric staining of proteins in mini polyacrylamide gels. Version 1.0 April 3, 2010.

Hand Held, BenchTop, 160Watt, ml

LED ROTATION BEAM LIGHT

Automatic Key Cutting MachineCONDOR XC-MINI CONDOR. Automatic Key Cutting Machine XC-MINI. User Manual

Pump Specifications 450 Series 1/2 hp Submersible Sump Pump

HCP-7000 Opreator s Manual 1. Operator s Manual.

Please read through the usage and service instructions outlined in this owner s manual before operating the unit. Warnings Diagrams...

User's Guide. ExStik CL200A. Waterproof Total Residual Chlorine Tester Patent Pending

INSTRUCTION MANUAL Sintering furnace Version 0.6.6

Industrial flue gas probes. Instruction manual

Vegetable Cutter. Instruction Manual

HX-Series. HX-502 (500g x 0.01g) HX-3001 (3000g x 0.1g. Copyright 2014 American Weigh Scales, Inc. All rights reserved. Rev. 1.0

DIVISION 33 UTILITIES SECTION PACKAGED SEWAGE GRINDER PUMPING UNITS

S-5 Bulk Filler System

DISSTON WELDING PRODUCTS TIG/MMA-160/180/200/250D. Welding Machines

Mill, Burr STANDARD OPERATING PROCEDURE

Quick Start Guide. Corporation Rev. 1

User s Manual. Chart Projector GCP-7000

Introduction Specifications Control Panel / Remote Unit Diagrams Setting Up the Unit Maintaining the Unit Safety info / Warnings Warranty Information

Instruction Manual ODY-1012

booster EX2 / EX3 Operating Manual Extrusion Welder Weldy AG Galileo-Strasse 10 CH-6056 Kaegiswil / Switzerland TECHSPANGROUP

INSTRUCTION MANUAL FOR WIRE WELDING MACHINE

How Molekule Works. After two decades of research and development, a fundamentally new approach to air purification has arrived to your home.

INCLUDED CONTENTS. Thank you for your purchase of the Galaxy Seeker Quadcopter. You re just moments away from creating stunning aerial acrobatics!

78-RK VARIABLE SPEED HEAVY DUTY VIBRATOR OPERATING MANUAL

Mobile Hot Food Merchandiser Series. Series: MM Operation Manual

Contents. 1. About this edition of user instructions

Transcription:

Instruction Manual HT 24 BM-D2400 Homogenizer

Foreword Thank you for purchasing a HT 24 Homogenizer. This manual contains instructions for the proper operation and care of this instrument. Please read it carefully before operation and keep it available for future use. Prior to initial operation: Please check the instrument and the accessories against the packing list when you first open the shipping carton. Report any damage, discrepancy, or missing items to the supplier immediately.

Safety Warnings and Guidelines 1. Important operation information: Read this manual carefully before attempting to operate the instrument. Read this manual prior to powering up the instrument. Pay special attention to the guidelines and directions below and be familiar with all safety warnings and guidelines. 2. Safety: 3. The operation, maintenance and repair of the instrument should comply with the basic guidelines and safety warnings below. Noncompliance may interfere with the useable life of the instrument and safety protection and may void the warranty. Use this product indoors. environment. Do not operate in a damp or wet Before using the instrument, read the manual carefully. This instrument is designed for use in laboratory environments and must be operated by skilled personnel with the appropriate training. Do not attempt to open the casing or repair the instrument. Disassembly will void the warranty. If there is a service issue with the instrument, please contact the supplier. Before operation, check to see that the voltage rating on the instrument matches your local voltage. The rated electrical load of the outlet should not be lower than that of the instrument's demand. If the power cord is damaged, it should be replaced. Do not place the power cord where it will have objects placed on it or where it will be walked on. When unplugging the instrument, do not pull the plug out of the socket by the cord.

Install the instrument in a cool, dry location free from dust, direct sunlight or strong lights. The instrument should be placed away from corrosive gasses, strong magnetic fields, and heat sources. Allow at least 4 inches on all sides of the instrument for proper air circulation. Be sure that the air vent at the back of the instrument is not blocked. If using two instruments, they should be placed at least 3 feet apart. The power switch is located on the rear of the instrument. After use, the power to the instrument should be turned off. If the instrument will not be used for a long period of time, it should also be unplugged and covered with a cloth or plastic to keep it free of dust. If samples are processed for an extended time period, many cycles or without a pause between cycles, thermal breakdown of the sample tube may occur. Be sure to follow manufacturers guidelines for lysing kits and tubes. The instrument should be unplugged immediately and the supplier contacted in the event of: Liquid leaking into the instrument Smoke or fire Abnormal operation - ie sound or smell The instrument has been dropped or outer housing damaged Instrument function changes 4. Maintenance The tube holder should be cleaned with a cloth dampened with a small amount of alcohol. The outside of the unit can be cleaned with a damp cloth or mild detergent if required. Always disconnect power to the unit before any cleaning procedure. Do not apply cleaning solutions directly to the tube holder or chamber. Do not use corrosive agents while cleaning. Do not submerge the instrument.

Contents CHAPTER 1 INTRODUCTION ---------------------------------------------------------------------------- 1 CHAPTER 2 SPECIFICATIONS -------------------------------------------------------------------------- 2 1. NORMAL OPERATION CONDITIONS: ------------------------------------------------------------- 2 2. THE BASIC PARAMETERS AND CHARACTERISTICS --------------------------------------- 2 CHAPTER 3 BASIC INSTRUCTIONS ------------------------------------------------------------------ 3 1. STRUCTURE OVERVIEW ----------------------------------------------------------------------------- 3 2. OPERATION PANEL ------------------------------------------------------------------------------------ 4 3. DISPLAY --------------------------------------------------------------------------------------------------- 4 CHAPTER 4 OPERATION GUIDE---------------------------------------------------------------------- 5 1. LOADING TUBES ---------------------------------------------------------------------------------------- 5 2. PROGRAM SELECTION ------------------------------------------------------------------------------- 7 3. PROGRAM SETTING ----------------------------------------------------------------------------------- 7 4. RUNNING AND STOPPING PROGRAMMED OPERATION ----------------------------------- 8 5. MOTOR OVER TEMPERATURE PROTECTION ------------------------------------------------- 8 6. BEAD SELECTION -------------------------------------------------------------------------------------- 9 CHAPTER 5 TROUBLESHOOTING GUIDE --------------------------------------------------------- 10

Chapter 1 Introduction Chapter 1 Introduction The HT 24 is a homogenizer for biological samples. It features high speed, three-dimensional vibration and has a capacity for 24 samples. Features: Can break and crack most biological samples (animal and plant tissue, soils, yeast, spores, microorganisms, etc.) Processes 24 samples in a minimal amount of time. On board memory for 50 programmed runs. Run stops automatically if the cover is opened. 1

Chapter 2 Specifications 1. Normal operating conditions: Ambient temperature:5 C 35 C The relative humidity: 70% Power:AC100-240V~ 50-60Hz Chapter 2 Specifications 2. The basic parameters and characteristics Parameter Type BM-D2400 Display OLED Speed 4.00m/s~7.00m/s, in 0.05m/s increments Cycle duration 1s~ 1min 30s, in 1s increments Pause 1s~ 2min, in 1s increments Number of Cycles 10 Programs 50 Sample Size 24 X 2.0ml tubes Acceleration time <2s Deceleration time <2s Noise Power Dimension(WXDXH) Weight(kg) <68db 600W 280mm 360mm 385mm 25.0kg Speed Conversion: 4.0 m/s = 2500 rpm 5.0 m/s = 3000 rpm 6.0 m/s = 3600 rpm 7.0 m/s= 4250 rpm 2

Chapter 3 Basic instructions Chapter 3 Basic instructions This chapter focuses on the structure, operation keys and display of the instrument, as well as preparatory work before starting. Please read this chapter before initial operation. 1. Structure overview Cover Latch Protective cover Tube retainer Display screen Operation panel On/Off button Air opening Power supply plug 3

Chapter 3 Basic instructions 2. Operation panel Prog. Set Start Stop Use in conjunction with to select the desired program. Set speed, run time, cycle and pause time for the current program. Modify parameters Run program Stop program 3. Display PROG:01 28ºC SPEED 6.50 03 M/S 0:30 TIME 0:30 M:S CYCLE INTER.. M:S 4

Chapter 4 Operation Guide Chapter 4 Operation Guide 1. Loading Tubes 1.1 Disengage the locking latch (as shown below), turn the knob counter-clockwise and remove the tube retainer. Knob Tube retainer Locking latch 1.2 The tube holder may be filled in or out of the instrument. To remove, simply lift off the shaft. Place sample tubes into the tube holder and press down until seated. If less than 24 samples are used, they should be evenly distributed in the tube holder. If removed, the tube holder can then be replaced, making sure the two bumps on the holder line up with the indentations on the shaft. Sample tube Tube holder 5

Chapter 4 Operation Guide 1.3 Place tube retainer on top of the tube holder. Tighten the knob clockwise and push the locking latch inwards. A click will indicate that the latch is in place. If the latch cannot be pushed inwards, turn the knob 5 degrees and try again. Note:The locking latch must be pushed in the LOCK position. Tighten the knob clockwise, and push the locking latch inwards to lock the tube retainer in place 1.4 Close the cover and engage the cover latch. Operation can then begin. DO NOT ATTEMPT TO OPERATE THE UNIT WITHOUT THE TUBE RETAINER IN PLACE! 6

Chapter 4 Operation Guide 2. Program selection PROG:01 28ºC SPEED 6.50 03 M/S 0:30 TIME 0:30 M:S CYCLE INTER.. M:S 50 onboard programs are available. To access the programs, press and hold the Prog. key, and then use or keys to scroll through the programs. To change m/s to rpm, press and key simultaneously. 3. Program setting Step 1: Press Set key once, SPEED in display flashes, then press or to adjust the speed. Step 2: press Set key again, CYCLE in display flashes, then press or to set the number of cycles. Step 3: press Set key again, TIME in display flashes, then press or to set the run time. Step 4: press Set key again, INTER in display flashes,then press or to set the pause time. Values will be automatically be saved after 3 seconds. 7

Chapter 4 Operation Guide 4. Running and stopping programmed operation Press Start to begin operation. Press Stop to end operation. Note:Before beginning operation, be sure that the tube retainer is in the proper position and locked in place. If there is abnormal noise during operation, press Stop at once to stop running, or turn off using the On/Off switch on the back of the instrument directly. Stop On/Off button 5. Motor over-temperature protection An over temperature sensor protects the motor against damage. The display shows the temperature of the motor. If the temperature goes above 65º, the unit will shut down until the temperature has dropped below 60ºC. The display of the motor temperature can be turned on or off. Press the "Prog" and "Set" keys simultaneously to display the following screen: Sensor: on Press run to return Press or, to toggle between ON and OFF. Press start to confirm the selection. If set to "ON" the temperature of the motor will appear in the screen. 8

Chapter 4 Operation Guide 6. Bead selection Bead Ordering Information Item Number Description Suggested Use PFAW 100-100-01 100 µm Silica Beads Bacteria. PFAW 100-100-02 100 µm Zirconium Beads Bacterial disruption (Zirconium beads are of higher density) PFAW 200-100-03 200 µm Zirconium Beads Bacteria & small yeasts, such as Pichia. PFAW 400-100-04 400 µm Silica Beads Yeast such as Saccharomyces PFAW 400-100-30 400 µm Zirconium Beads Yeast, single cell algae, biofilm PFAW 800-100-05 800 µm Silica Beads Molds and pollen PFAW 800-100-29 800 µm Zirconium Beads Molds, pollen, algae PFAW 1000-100-21 1.0 mm Zirconium Beads Disruption of finer soils PFAW 1400-100-19 1.4 mm Zirconium Beads Small tissue samples & biomass PFAW 1700-50-16 1.7 mm Zirconium Beads Large tissue samples and fine plant materials PFAW 3000-50-17 3.0 mm Zirconium Beads Larger tissue samples. Excellent chemical resistance to organics PFMM 500-100-25 500 µm Garnet & 6 mm Zirconium Satellite Mixed Mode Resilient tissue shredding: skin, sclera, hair PFMM 800-100-27 800 µm & 1.4 mm Zirconium Beads Mixed Mode Mycelium & Soft Leaves PFMM 100-100-31 100 µm & 400 µm Silica Beads Mixed Mode Mixed samples (yeast + bacteria) PFMM 400-100-28 100 µm & 4 mm Silica, 1.4 Zirconium Mixed Mode Biofilms & Plant Tissues PFSS 2800-50-20 2.8 mm Stainless Steel Grinding Balls Most dense of all the grinding media, great for tissues 9

Chapter 5 Troubleshooting Guide Chapter 5 Troubleshooting Guide Problems and actions No. Common problem Possible cause Action(s) No power Check power supply and that unit is plugged in properly 1 No display on the screen 2 3 Error: lid displayed, audible alert open audible alert displayed, 4 Instrument does not run 5 Abnormal running noise On/Off switch broken Change switch Faulty fuse Change fuse(5x20 250V 10A) Others Faulty button - protection cover Motor over temp protection- open circuit Contact supplier Contact supplier Contact supplier Motor temp above 65º Wait for temp to drop below 60º Faulty Controller Faulty Motor Contact supplier Tube retainer not locked Place tube retainer in place and in place lock down properly Faulty bearing Contact supplier 6 Keys don t work Plug connector loose Faulty key Contact supplier Contact supplier Phone: 908.253.3444 FAX: 908.575.1660 Email: info@opsdiagnostics.com 10

Memo