BM SERIES COMPACT GUIDE WAVE GUIDED WAVE RADAR LEVEL INSTRUMENTS

Similar documents
BM ULTRA COMPACT/REMOTE UC SERIES ULTRASONIC LEVEL INSTRUMENTS (Compact/Remote version)

Continuous Level Sensor CONDURIX 31.1

SI-02. Features. Electromagnetic Flowmeter for General Applications. Description: Application:

Silver Automation Instruments

PanaFlow MV82. Insertion Multivariable Flowmeter for Mass, Temperature, and Pressure. GE Sensing. Applications. Key Benefits

FN04. Liquid level sensor with continuous detection. Level Measurement and Monitoring

Plastic tube flowmeters Series PT/PS Variable area flowmeter for liquids and gases

ADDENDUM TO IECEx CERTIFICATE OF CONFORMITY IECEx BKI Page 1 of 8

Level measurement Ultrasonic. Overview VEGASON series VEGASON series Dimensions Level measurement Ultrasonic

Technical Specifications: Measurable Metarial. Supply Signal Output

SITRANS P measuring instruments for pressure

ELECTRONIC EARTHING EQUIPMENT SERIES GRD 4200

Guided Wave Radar: VEGAFLEX series 80

Gas Sample Probe Series SP

Certificate of Compliance

FLOMID FX Electromagnetic Flowmeter

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

Moisture analyzers (moisture meters) FIZEPR-SW100

Flanged chemical seals series D

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

LMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

ILMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

Coriolis Mass Flow Meter

Electromagnetic Flange Type BTU METERS. eflow 800H SERIES. Size DN10 to DN1200 DESCRIPTION APPLICATION FEATURES

TRICOR. TRICOR Series. Technical Datasheet. Mass Flow Meters MISURATORE MASSICO - CORIOLIS MASS FLOW METER CORIOLIS TECHNOLOGY

Thermometer in stainless steel with vertical stem in stainless steel

Thermometer in stainless steel with adjustable stem in stainless steel. Compression fitting for direct mounting or mounting in separate thermowell

Moisture Analyzer. Description. Excellent solution for moisture measurement

Differential pressure

Expert SUBMERSIBLE LEVEL TRANSMÍTTERS BROCHURE US 2.75 EXPERT BROCHURE 1401

1 analogue output. 4Programmable for measurement. 4 The limits of the outputs are freely programmable within the measuring range.

SPRING LOADED THERMOCOUPLE CONFIGURATIONS THERMOWELL & REPLACEABLE INSERT II 2G/D Ex e TCRE/WE

With uncoated stainless steel rope electrode and coated dynamic anchorage for level measurement of bulk-solid materials in higher silos.

SmartScanTM. SolidScan You Can Measure the Solid Benefits. Ultrasonic Continuous Level Measurement of Liquids and Solids

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

THE MICROFLOW SENSOR MICROFLOW SENSOR WITH A WIDE RANGE OF APPLICATIONS THANKS TO THE AVAILABILITY OF DIFFERENT CONNECTION TYPES

RUNYI GROUP. Main Features. STLU Vortex Flow Meter

CombiTemp TCR6 Standard RTD temperature sensor

4-Beam-Turbidity Meter ITM-4

Model 140MX Flowmeter Functional Overview

SPRING LOADED THERMOCOUPLE CONFIGURATIONS

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

PRODUCT INFORMATION. Model 140MX Flowmeter Functional Overview. PI 14-1 Rev: 1 March 2002

Product information. UP-DO Pump Series Normal priming, centrifugal pumps with a double mechanical seal material: stainless steel 1.

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

POLYPROPYLENE SENSOR LIGHT WEIGHT SENSOR COMPLETELY IN POLYPROPYLENE

09. MACHINE ACCESSORIES. 202 Moulding Supplies Edition 9 // MOULD SCREENS 09.2 MOULD ALIGN 09.

Expert SUBMERSIBLE LEVEL TRANSMITTERS BROCHURE EN 2.75 EXPERT BROCHURE 1401

Thermometer in stainless steel with capillary for mounting in thermowell or for direct mounting

Level Switch. Series. instrumentation for fluids LC40. Instructions Manual

Intrinsically Safe Industrial Measuring Probes for Humidity, Temperature, and Derived Variables

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

NRF CAPACITANCE LEVEL TRANSMITTER

8.27/210 * 7.28/ / / /108. n x d. b f ML00343b. Dimensions are in inches/millimeters *8.86/225 for Pg 13.5 with adapter 2.

CVB-EX Mil-C-5015 reverse bayonet ATEX Connectors

Pressure transducers DMU 02 Vario (flush)

SITRANS L Level instruments

Sentinel LNG. Panametrics Ultrasonic Flowmeter for Cryogenic Liquids. GE Sensing & Inspection Technologies. Benefits. Applications

Thermocouple for Flue Gas Temperature Measurements,

CATALOG HHD ELECTROMAGNETIC FLOWMETER

Diaphragm pressure gauge per EN 837-3,

ARI-STEVI 440 / 441 (DN15-250) Control valve - straight through With pneumatic and electric actuators

ENGLISH. Datasheet. RS single element: Single 4 wire element, allowing connection to any Pt100 2, 3 or 4 wire instrument

Presented By. NicolScales.com Contact Us

Over pressure Switching pressure difference (typical) Lower range Upper range

Load cell Pendeo Process and mounting kits

4-Beam-Turbidity Meter ITM-4

4-Beam-Turbidity Meter ITM-4

Sentinel LNG. Panametrics Ultrasonic Flowmeter for Cryogenic Liquids. GE Sensing & Inspection Technologies. Benefits. Applications

QGO Oxygen Sensor. Building Technologies HVAC Products

ELS LEVEL SWITCH ELS. ELS B10p, ELS B10x, ELS B101x ELS K01, ELS K02, ELS K03 ELS P01, ELS P03, ELS P04

Pinch Control Valve 7079

CAPACITIVE LEVEL METERS CLM 36

TEK-B AR 3120B. Smart Gauge Pressure Transmitter. PRESSURE. Technology Solutions

ENGLISH Datasheet Platinum Resistance Pt100 4 wire class B Resistance Thermometer with DIN B Head

Agilent 4339B/4349B High Resistance Meters Technical Overview

Agilent 4339B/4349B High Resistance Meters Technical Overview

IOMaster FPD510 Compact integral orifice flowmeter. Low-cost measurement of small flowrates

Diaphragm pressure gauge

PRODUCT INTRODUCTION FEATURES

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

Diaphragm seal with flange connection With internal diaphragm, threaded design Model

Fig. 405 / 460 (DN15-500) Stop valve - straight through With pneumatic and electric actuators

Catalogue 2012/1. Temperature under control

Fig. 405 / 460 (DN15-500) Stop valve - straight through With pneumatic and electric actuators

Presented By. NicolScales.com Contact Us

Pressure Booster System. Hya-Eco VP. Type Series Booklet

Thermocouples Straight Design Model TC501, for Flue Gas Measurement

Reliable Management of Wastewater Solids. Valmet Total Solids Transmitter

ABB MEASUREMENT & ANALYTICS DATA SHEET. SCK Sampling system for dry gas sampling at rotary cement kiln gas exit and calciner gas exit

Averaging PITOT Tube 5RD series

LIQUID METER TYPE FMO

Capacitive level meter CLM 36

C.4. Coaxial. BNC Low Frequency / Single Ended Grounded Shield

SERIES OVAL GEAR FLOWMETER MOGF

Platinum Resistance Thermometer Pt100 Precision Probe - High accuracy platinum resistance thermometer probe, 6mm diameter x 250mm

PRESSURE SWITCHES D-LT Electro-mechanical pneumatic pressure switches. 18D-LT x2 Electro-mechanical pneumatic pressure switches.

- SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS PERFORMANCE CURVE MULTIGO PERFORMANCE CURVE MULTIGO

OXITEC Oxygen Analyser Systems. Maximum Efficiency and Supreme Quality for the World Market ENOTEC

Transcription:

GUIDED WAVE RADAR LEVEL INSTRUMENTS DESCRIPTION The microwaves impulses at high frequency travel through a stainless steel guide and they are reflected on the surface of the fluid to analyze. The period of time that passes between the emission of the impulses and their reception is proportional to the distance between the surface of the fluid and the plan of reference of the instrument. BM COMPACT GW5X series is supplied with the advanced microprocessor EchoDiscovery, it can be used in very different environmental conditions. The instruments have a low energetic consumption, can be installed on metallic or not metallic tanks. They are not dangerous for the users or the atmosphere. With the instruments BM COMPACT GW5X there is the possibility to use several options about the process connections or detectors. These options make the instrument usable in various conditions, as an example high temperature, high pressure, etc PRODUCTS OVERWIEV GUIDE WAVE GW51 GUIDE WAVE GW52 GUIDE WAVE GW53 GUIDE WAVE GW54 DISPLAY The instruments can be set up in 3 ways: 1. by display 2. by BMware software 3. by HART program GUIDE WAVE GW55 GUIDE WAVE GW56

TECHNICAL DETAILS GW51 for liquids and solids Applications: Level measurement of liquids and solids, suitable for critical enviroments. Max measurable distance: until 32 m Accuracy: ±10 mm Process connection: G 1½ A - 1½ NPT Antenna: Probe Materials: probe: AISI 316L / PTFE cable: AISI 316L / PTFE housing: plastic PBT-FR / Aluminium / AISI 316L Working temperature: -40 250 C Storage temperature: -40 80 C Relative umidity: <95% Pressure of use: -1 40 bar Resistance to vibrations: mechanical vibrations 10m/s2, 10 150Hz Interval of measure: Interval of updating: Resolution of display: 1mm Max loaded allowable: see diagrams following pages Max loaded allow. values guide: cable Ø 4mm = 5KN; cable Ø 6mm = 30KN Max loaded side, values guide: pole Ø 6mm = 4NM; pole Ø 16mm = 30NM Supply 2 wires : - Input voltages: 15 36Vdc - Ripple allowed: <100Hz, Uss>1V; 100Hz 10KHz, Uss<10mV Supply 4 wires : - Standard input voltages : 24Vdc ±10%; 230Vac ±10% Output signal: 2/4 wires 4-20 ma, HART Resolution: 6µA Fixed signal for anomaly: 20.5mA; 22mA; 3.6mA Resistance 2 wires : see following diagram Resistance 4 wires : max 500 ohm Integration time: 0 999s, programmable Cables entry: 1x PG 13.5 Weight: until 9 kgs (its depend by type of housing and mounting) Diagram of loaded resistance, 2 wires resistance Wiring resistance + HART resistance + loaded resistance HART Resistance explosion proof not-explosion proof Voltage

TECHNICAL DETAILS GW51 LOAD ALLOWED In the measurement of solid substances, the maximum allowed load is determined by the diameter of the tank and the medium level inside of the same one; in the following diagrams max allowed load are represented for some typical materials: thickness cabpermissible loaded le 6 mm. Diameter: 12m Diameter: 9m Diameter: 6m Diameter: 3m Cereals Sand Cable lenght (m) Granulate plastic Cable lenght (m) Cement Loaded permissible with cable 6 mm (KN) 6 mm (KN) Loaded permissible with cable 6 mm (KN) 6 mm (KN) Loaded permissible with cable 6 mm (KN) Loaded permissible with cable 6 mm (KN) 6 mm (KN) Cable lenght (m) Cable lenght (m)

TECHNICAL DETAILS GW51 LOAD ALLOWED In the measurement of solid substances, the max allowed load is determined by the diameter of the tank and the medium level inside of the same one; in the following diagrams allowed load examples are represented maximum for some typical materials: thickness cable 4mm. Cereal Sand Diameter: 12m Diameter: 9m Diameter: 6m Diameter: 3m Cable lenght (m) Cable lenght (m) Granulate plastic Cement Loaded permissible with cable 4 mm (KN) Loaded permissible with cable 4 mm (KN) Loaded permissible with cable 4 mm (KN) Loaded permissible with cable 4 mm (KN) Cable lenght (m) Cable lenght (m)

TECHNICAL DETAILS GW51 - follow Precision Dimensions with AL/316L frame Dimensions Dimensions with PBT-FRL frame Dimensions with AL (2 readers) frame

ORDERING CODE GW51 P Standard Type of Detecting Component /Material A Rope /AISI 316L / PTFE B Rod/ AISI 316L / PTFE C Rope/ AISI 316L / Lengthen PP D Rod/ AISI 316L / Lengthen PP E Rope/ AISI 316L / Lengthen PTFE F Rod/ AISI 316L / Lengthen PTFE X Special Type Process Connections GP Thread G 1½ A KP Thread G 2A NP Thread 1½ NPT YP Special Type Retained seal / Working temperature A Viton / -30 150 C B Kalrez / -40 250 C Electronic B 4 20 ma HART (2 wires) C D E 4 20 ma / 22,8 26,4 VDC/ 4 wires 4 20 ma /198 242 VDC HART (4 wires) 4 20 ma /22,8 26,4 VDC HART (2 wires) Housing Material / General Protection B Plastic / IP66 A Aluminium / IP67 D Aluminium (2 chambers) / IP67 G AISI 316L / IP67 Wiring M M20x1.5 N ½ NPT Display / Programming Cable lenght / pole Enter a Five-Digit value in mm

TECHNICAL DETAILS GW52 for liquids and solids Applications: Level measurement of liquids and solids, suitable in critical enviroments. Max measurable distance: until 6 m Accuracy: ±10 mm Process connection: Flange Antenna: Rope Materials: pole: PTFE housing: plastic PBT-FR / Aluminium / AISI 316L Working temperature: -40 150 C Storage temperature: -40 80 C Relative umidity: <95% Pressure of use: -1 40 bar Resistance to vibrations: mechanical vibrations 10m/s2, 10 150Hz Interval of measure: Interval of updating: Resolution of display: 1mm Max loaded allowable: see diagrams following pages Max loaded allow. values guide: cable Ø 4mm = 5KN; cable Ø 6mm = 30KN Max loaded side, values guide: pole Ø 6mm = 4NM; pole Ø 16mm = 30NM Supply 2 wires : - Input voltages: 15 36Vdc - Ripple allowed: <100Hz, Uss>1V; 100Hz 10KHz, Uss<10mV Supply 4 wires : - Standard input voltages : 24Vdc ±10%; 230Vac ±10% Output signal: 2/4 wires 4-20 ma, HART Resolution: 6µA Fixed signal for anomaly: 20.5mA; 22mA; 3.6mA Resistance 2 wires : see following diagram Resistance 4 wires : max 500 ohm Integration time: 0 999s, programmable Cables entry: 1x PG 13.5 Weight: until 5.5 kgs (its depend by type of housing and mounting) Diagram of loaded resistance, 2 wires resistance Wiring resistance + HART resistance + loaded resistance HART Resistance explosion proof not- explosion proof Voltage

TECHNICAL DETAILS GW52 - follow Precision Dimensions with AL/316L frame Dimensions Dimensions with PBT-FRL frame Dimensions with AL frame (2 readers)

ORDERING CODE GW52 P Standard Type of Detecting Component/ Material A Rope/ PTFE Connection / Material GP Flange DN50 PN16 AISI 316L (GB/T9119-2000) NP Flange DN80 PN16 AISI 316L (GB/T9119-2000) EP Flange DN100 PN16 AISI 316L (GB/T9119-2000) FP Flange DN150 PN16 AISI 316L (GB/T9119-2000) YP Special Connection Retained seal / Working temperature A PTFE / -30 150 C Electronic B 4 20 ma HART (2 wires) C D E 4 20 ma / 22,8 26,4 VDC/ HART 4 wires 4 20 ma / 198 242 VAC / HART (4 wires) 4 20 ma / 22,8 26,4 VDC / HART (2 wires) Housing Material / General Protection B Plastic / IP66 A Aluminium / IP67 D Aluminium (2 chambers) / IP67 G AISI 316L / IP67 Wiring M M20x1.5 N ½ NPT Display / Programming A YES Cable length / pole Enter a Four-Digit value in mm Note: The size of the flange refers to GB/T9119-2000 PN16. the thickness of the flange is 15mm.

TECHNICAL DETAILS GW53 for liquids Applications: Level measurement of liquids, suitable for those with dielectric low constant, in critical enviroments. Max measurable distance: until 6 m Accuracy: ±10 mm Process connection: G 1½ A - 1½ NPT Antenna: Pole coaxial Ø 28 mm Materials: pole: AISI 316L housing: plastic PBT-FR / Aluminium / AISI 316L Working temperature: -40 250 C Storage temperature: -40 80 C Relative umidity: <95% Pressure of use : -1 40 bar Resistance to vibrations: mechanical vibrations 10m/s2, 10 150Hz Interval of measure: Interval of updating: Resolution of display: 1mm Max loaded allowable: see diagrams following pages Max loaded allow. values guide: cable Ø 4mm = 5KN; cable Ø 6mm = 30KN Max loaded side, values guide: pole Ø 6mm = 4NM; pole Ø 16mm = 30NM Supply 2 wires : - Input voltages: 15 36Vdc - Ripple allowed: <100Hz, Uss>1V; 100Hz 10KHz, Uss<10mV Supply 4 wires : - Standard input voltages : 24Vdc ±10%; 230Vac ±10% Output signal: 2/4 wires 4-20 ma, HART Resolution: 6µA Fixed signal for anomaly: 20.5mA; 22mA; 3.6mA Resistance 2 wires : see following diagram Resistance 4 wires : max 500 ohm Integration time: 0 999s, programmable Cables entry: 1x PG 13.5 Weight: until 6 kgs (its depend by type of housing and mounting) Diagram of loaded resistance, 2 wires resistance Wiring resistance + HART resistance + loaded resistance HART Resistance explosion proof not- explosion proof Voltage

TECHNICAL DETAILS GW53 - follow Precision Dimensions with AL/316L frame Dimension Dimensions with PBT-FRL frame Dimensions with AL frame (2 readers)

ORDERING CODE GW53 P Standard Type of Detecting Component/ Material A Coaxial pole Ø 28mm / AISI 316L Connections / Material GP Thread G 1 ½ A KP Thread G 2 A NP Thread G 1 ½ NPT YP Special Connection Retained seal / Working temperature A Viton / -30 150 C B Kalrez / -40 150 C Electronic B 4 20 ma HART (2 wires) C 4 20 ma / 22,8 26,4 VDC 4 wires D 4 20 ma / 198 242 VAC / HART (4 wires) E 4 20 ma / 22,8 26,4 VDC / HART (2 wires) Housing Material / General Protection A Aluminium / IP67 B Plastic / IP66 D Aluminium (2 chambers) / IP67 G AISI 316L / IP66 Wiring M M20x1.5 N ½ NPT Display / Programming A YES Rod Length Enter a Four-Digit value in mm

TECHNICAL DETAILS GW54 for liquids Applications: Level measurement of liquids, suitable for critical enviroments, to high temperature and high pressure. Max measurable distance: until 6 m (pole), until 30 m (probe) Accuracy: ±10 mm Process connection: G 1½ A - 1½ NPT Antenna: Pole / Probe Materials: pole: AISI 316L probe: AISI 316L housing: plastic PBT-FR / Aluminium / AISI 316L Working temperature: -40 250 C Storage temperature: -40 80 C Relative umidity: <95% Pressure of use: -1 40 bar Resistance to vibrations: mechanical vibrations 10m/s2, 10 150Hz Interval of measure: Interval of updating: Resolution of display: 1mm Max loaded allowable: see diagrams following pages Max loaded allow. values guide: cable Ø 4mm = 5KN; cable Ø 6mm = 30KN Max loaded side, values guide: pole Ø 6mm = 4NM; pole Ø 16mm = 30NM Supply 2 wires : - Input voltages: 15 36Vdc - Ripple allowed: <100Hz, Uss>1V; 100Hz 10KHz, Uss<10mV Supply 4 wires : - Standard input voltages : 24Vdc ±10%; 230Vac ±10% Output signal: 2/4 wires 4-20 ma, HART Resolution: 6µA Fixed signal for anomaly: 20.5mA; 22mA; 3.6mA Resistance 2 wires : see following diagram Resistance 4 wires : max 500 ohm Integration time: 0 999s, programmable Cables entry: 1x PG 13.5 Weight: until 12 kgs (its depend by type of housing and mounting) Diagram of loaded resistance, 2 wires resistance Wiring resistance + HART resistance + loaded resistance HART Resistance explosion proof not-explosion proof Voltage

TECHNICAL DETAILS GW54 - follow Precision Dimensions with AL/316L frame AL/316L Dimensions Dimensions with PBT-FRL frame Dimensions with AL frame (2 readers)

ORDERING CODE GW54 P Standard Type of Detecting Component / Material A Rope / AISI 316L / PTFE B Rod /AISI 316L / PTFE C Rope / AISI 316L / Lengthen PP D Rod / AISI 316L / Lengthen PP E Rope / AISI 316L / Lengthen PTFE F Rod / AISI 316L / Lengthen PTFE X Special Type Connections GP Thread G 1½ A KP Thread G 2A NP Thread 1½ NPT Retained seal / Working temperature A Viton / -30 250 C B Kalrez / -40 250 C Electronic B 4 20 ma HART (2 wires) C 4 20 ma / 22,8 26,4 VDC HART 4 wires D 4 20 ma / 198 242 VAC HART 4 wires E 4 20 ma / 22,8 26,4 VDC HART 2 wires Housing Material / General Protection A Aluminium / IP67 B Plastic / IP66 D Aluminium (2 chambers) / IP67 G AISI 316L / IP67 Wiring M M20x1.5 N ½ NPT Display / Programming A YES Cable length / pole Enter a Five-Digit value in mm

TECHNICAL DETAILS GW55 for liquids Applications: Level measurement in liquids, suitable for critical enviroments, to high temperature and high pressure. Max measurable distance: until 6 m (pole), until 30 m (probe) Accuracy: ±10 mm Process connection: G 1½ A - 1½ NPT Antenna: Pole / Probe Materials: pole: AISI 316L / Ceramic probe: AISI 316L / Ceramic housing: plastic PBT-FR / Aluminium / AISI 316L Working temperature: -200 400 C Storage temperature: -40 80 C Relative umidity: <95% Pressure of use: -1 40 bar Resistance to vibrations: mechanical vibrations 10m/s2, 10 150Hz Interval of measure: Interval of updating: Resolution of display: 1mm Max loaded allowable: see diagrams following pages Max loaded allow. values guide: cable Ø 4mm = 5KN; cable Ø 6mm = 30KN Max loaded side, values guide: pole Ø 6mm = 4NM; pole Ø 16mm = 30NM Supply 2 wires : - Input voltages: 15 36Vdc - Ripple allowed: <100Hz, Uss>1V; 100Hz 10KHz, Uss<10mV Supply 4 wires : - Standard input voltages : 24Vdc ±10%; 230Vac ±10% Output signal: 2/4 wires 4-20 ma, HART Resolution: 6µA Fixed signal for anomaly: 20.5mA; 22mA; 3.6mA Resistance 2 wires : see following diagram Resistance 4 wires : max 500 ohm Integration time: 0 999s, programmable Cables entry: 1x PG 13.5 Weight: until 9 kgs (its depend by type of housing and mounting) Diagram of loaded resistance, 2 wires resistance Wiring resistance + HART resistance + loaded resistance HART Resistance explosion proof not-explosion proof Voltage

TECHNICAL DETAILS GW55 - follow Precision Dimensions Dimensions with AL/316L frame AL/316L Dimensions with PBT-FRL frame Dimensions with AL frame (2 readers)

ORDERING CODE GW55 P Standard Type od Detecting Component / Material A Rope/ AISI 316L / Ceramic B Rod /AISI 316L / Ceramic Connections GP Thread G 1½ A KP Thread G 2A NP Thread 1½ NPT Electronic B 4 20 ma HART(2wires) C 4 20 ma / 22,8 26,4 VDC HART 4 wires D E 4 20 ma / 198 242 VAC HART 4 wires 4 20 ma / 22,8 26,4 VDC HART 2 wires Housing Material / General Protection B Plastic / IP66 A Aluminium / IP67 D Aluminium (2 chambers) / IP67 G AISI 316L / IP67 Working temperature A -200.400 C Wiring M M20x1.5 N ½ NPT Display / Programming A YES Cable length / pole Enter a Five-Digit value in mm

TECHNICAL DETAILS GW56 for liquids and dust Applications: Level measurement in liquids, suitable for critical enviroments, with dielectric low constant. Max measurable distance: until 6 m (pole), until 30 m (probe) Accuracy: ±10 mm Process connection: G 1½ A - 1½ NPT Antenna: Pole / Probe Materials: pole: AISI 316L / PTFE probe: AISI 316L / PTFE housing: plastic PBT-FR / Aluminium / AISI 316L Working temperature: -40 250 C Storage temperature: -40 80 C Relative umidity: <95% Pressure of use: -1 40 bar Resistance to vibrations: mechanical vibrations 10m/s2, 10 150Hz Interval of measure: Interval of updating: Resolution of display: 1mm Max loaded allowable: see diagrams following pages Max loaded allow. values guide: cable Ø 4mm = 5KN; cable Ø 6mm = 30KN Max loaded side, values guide: pole Ø 6mm = 4NM; pole Ø 16mm = 30NM Supply 2 wires : - Input voltages: 15 36Vdc - Ripple allowed: <100Hz, Uss>1V; 100Hz 10KHz, Uss<10mV Supply 4 wires : - Standard input voltages : 24Vdc ±10%; 230Vac ±10% Output signal: 2/4 wires 4-20 ma, HART Resolution: 6µA Fixed signal for anomaly: 20.5mA; 22mA; 3.6mA Resistance 2 wires : see following diagram Resistance 4 wires : max 500 ohm Integration time: 0 999s, programmable Cables entry: 1x PG 13.5 Weight: until 9 kgs (its depend by type of housing and mounting) Diagram of loaded resistance, 2 wires resistance Wiring resistance + HART resistance + loaded resistance HART Resistance explosion proof not- explosion proof Voltage

TECHNICAL DETAILS GW56 - follow Precision Dimensions with AL/316L frame AL/316L Dimensions Dimensions with PBT-FRL frame L Dimensions with AL frame (2 readers)

ORDERING CODE GW56 P Standard Type of Detecting Component / Material A 2-Rope / AISI 316L / PTFE B 2-Rod / AISI 316L / PTFE Connections / Material GP Thread G 1½ A AISI 316L KP Thread G 2A AISI 316L NP Thread 1½ NPT AISI 316L Electronic B 4 20 ma HART (2 wires) C 4 20 ma / 22,8 26,4 VDC HART 4 wires D 4 20 ma / 198 242 VAC / HART 4 wires E 4 20 ma / 22,8 26,4 VDC HART 2 wires Retained seal / Working temperature A Viton / -30 150 C B Kalrez / -40 250 C Housing Material / General Protection A Aluminium / IP67 B Plastic / IP66 D Aluminium (2 chambers) / IP67 G AISI 316L / IP67 Wiring M M20x1.5 N ½ NPT Display / Programming A YES Cable length / pole Enter a Five-Digit value in mm