Date Rater Verified. Rater Verified. Slab / Pre-Drywall / Thermal Inspection

Similar documents
Feature Zone IECC 2009 IECC

A Closer Look Inspection Service 2015 IECC Residential DFW area handout

Hardin County Planning and Development Commission

Table Air Barrier and Insulation Inspection Component Criteria

Town/City: State: Zip: Town/City: State: Zip: Phone: Cell: Phone: Cell:

General Contractor: Company Name: Location of Proposed Structure: Tax Map #: Lot #:

2015 MICHIGAN UNIFORM ENERGY CODE Effective: February 8, 2016

FIELD COPY ATTACHMENT

Charter Township of Washington

2015 Michigan Residential Code Energy Worksheet for New Single-family Residential Building

Presented by: Stephen Carr Regional Building Science Manager (386)

2015 Michigan Residential Code Energy Worksheet for New Single-family Residential Building

Town of Farragut RESIDENTIAL CONSTRUCTION ENERGY EFFICIENCY. LAST UPDATE: July 03, 2014

Presented by: Stephen Carr Regional Building Science Manager (386)

Energy Efficiency Programs

Boulder City NV Prepared by (Print Name) Signature Date

SUSTAINABLE ENERGY ANALYTICS

2015 Michigan Residential Code Energy Worksheet for Single-family Additions, Alterations, Renovations and Repairs

Michigan Energy Code Training and Implementation Program

IRC 2012 Key Changes

Town/City: State: Zip: Town/City: State: Zip: Phone: Cell: Phone: Cell:

Air Sealing for 5 ACH 50

Performance Requirements and Options in the International Energy Conservation Code. Mike Turns, Senior Program Manager

2015 IECC Air Sealing Multifamily For Code Compliance Funding for Energy Code Training

Fenestration Components: Mechanical Summary. Water heater energy factor: Ef Fuel type: Gas Electric Other

REScheck Software Version Compliance Certificate

Prescriptive Checklist for the 2015 Washington State Energy Code

Presentation Overview: NC Energy Code RESNET Standards HERS Index HERS Verification Process

Energy Efficiency Requirements 9.36

SAN MIGUEL COUNTY & TOWN OF MOUNTAIN VILLAGE BUILDING DEPARTMENTS PRESCRIPTIVE ENERGY CODE & GREEN BUILDING STANDARD

Residential Data Collection Checklist 2009 International Energy Conservation Code Climate Zone 2

Air Sealing, Infiltration & Ventilation

Project Type: New Home Addition Alteration (Describe)

Standards for Jackson EMC s Right Choice Program Revised: June 2011

PICK YOUR POISON AND HOW TO GET THERE. Presented By Robby Schwarz

A.ENVELOPE AIR SEALING

2014 British Columbia Building Code Changes

Explaining the Thermal Bypass Checklist. Ed Minch, Energy Services Group Kelly Parker, GWS

ENERGY STAR Qualified Homes National Program Requirements, Version 3.0

Urban Revitalization Plan For Responsible and Sustainable Growth and Development City of Adel, Iowa

2012 IECC Residential with State Adopted Changes

2009 IECC with St Louis Amendments. Fenestration U-factor Skylight U-factor Glazed fenestration SHGC NR 0.

IECC Residential Significant Changes Summary. Tier I

Chapter 14 - Air Sealing

Appendix RA Air Sealing and Insulation Key Points COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA

Overview of Presentation. Airflow Control: Why. Airflow Control: what kind?

Project Name: Enforcement Agency: Permit Number:

Energy Star Qualified - New Homes

A Rater s perspective from the field. Thomas H. Marston, February 21, 2007

SOUTHWEST ENERGY CODES CONFERENCE. This is how we do it! Getting to 3ACH50 and

Measure 1 Seal Ducts Components Inspected

ENERGY STAR Homes version 3 Designing and Building to Meet the 2011 Changes. Thursday, February 24, 2011

Rebates for Improvements Home Efficiency Program Fort Collins Utilities

A LOOK INTO THE 2015 IECC RESIDENTIAL PROVISIONS. Presented by: Shaunna Mozingo, Colorado Code Consulting

MECHANICAL INSPECTION DIVISION CITY OF NEW ORLEANS

Initial House Assessments & Sealing Options:

Residential Codes FAQs: 2015 International Energy Conservation Code (IECC) with MA Amendments & MA Stretch Energy Code

Green Remodeling Illustrations GREEN REMODELING ILLUSTRATIONS GREEN BUILDING GUIDELINES FOR HOME REMODELING

Attic Access Hatch to have an area not less than 0.32m²/3.4ft² and no dimension less than 500mm with a min R-15 insulation value Crawlspace

Residential Buildings Energy Code Summary

DOE Zero Energy Ready Home National Program Requirements (Rev. 06) April 20, 2017

Compliance Certificate

Plan Check & Field Inspection Guide

Thermal Bypass Checklist: How We Got There?

Work Order (Bid Form) Upper East Tennessee Human Development Agency

The times are changing. Are you Ready?

Insulation, Fireblocking, Draftstopping and Crawl Space Requirements REVISION DATE: JANUARY 2017

1/17/2018. IECC Real World Applications. The look and layout of the 2015 IECC. The IECC covers both: Commercial (CE) chapters 1-6.

ENERGY STAR Qualified Homes, Version 3 (Rev. 03) Inspection Checklists For National Program Requirements

Homes Across Nebraska Are Being Built to the Latest National Energy Standards Is Yours?

Montana Homebuilder Brief: Residential Energy Code 1

California HERO Program Residential Eligible Product List All Products

Energy Efficiency: Designing Wood-Frame Buildings for Occupant Comfort

Please Submit Plans and Forms Electronically.

Chapter 33 - Checklists

THE CITY OF FAYETTEVILLE ADOPTED THE 2009 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) ON JULY 17, 2012

Initial House Assessments & Sealing Efforts: California Builder #1

RESIDENTIAL ENERGY EFFICIENCY


Quick Reference Guide for 2009 IECC Residential Energy Efficiency Climate Zone 2

INFORMATIONAL HANDOUT FOR FINISHING A BASEMENT

REScheck Software Version Compliance Certificate

Compliance Certificate

APPROVED. Acceptable to the code official for compliance with the provisions of the applicable Code or referenced Standard.

Work Write Up / Specification of Repairs HUD DIVISION 1. MASONRY HUD DIVISION 2. SIDING. Toll Free

Florida HERO Program Residential Eligible Product List All Products

COMcheck Software Version Envelope Compliance Certificate

HERO Program Residential Eligible Product List California Residential Eligible Products... 2

RESIDENTIAL ENERGY CODE. The 2015 International Energy Conservation Code (IECC) as modified below.

RESIDENTIAL ENERGY EFFICIENCY

Work Order (Bid Form) Upper East Tennessee Human Development Agency

Work Order (Bid Form) Upper East Tennessee Human Development Agency

Quick Reference Guide for 2009 IECC Residential Energy Efficiency Climate Zone 3

HOUSING ENERGY- EFFICIENCY INSPECTION FIELD MANUAL

2010 National Building Code Adoption and Associated Process Changes

SystemVision Contractor s Guide COPYRIGHT 2016 ADVANCED ENERGY. ALL RIGHTS RESERVED

IECC Provisions for Multi-Family Buildings

Energy Compliance Information

Energy Compliance Information

THE GEORGIA ENERGY CODE: 2009 IECC + AMENDMENTS

Transcription:

Slab on Grade & Basements: A capillary break is installed on top of all footings Slab / Pre-Drywall / Thermal Inspection A minimum of 4" of clean or washed gravel (0.5" diameter or greater) is placed over the soil All gravel is covered with a minimum of 10 millimeter polyethylene sheeting Polyethylene joints are overlapped a minimum of 6" and taped Slab on Grade & Walk-Out Slab Edge Insulation: A minimum of R-10 extruded polystyrene is installed next to the slab edge down to the footing Slab on Grade & Basement Floor: A minimum of R-5 extruded polystyrene is installed below the entire slab with a minimum of R-10 extruded polystyrene installed at least the outer 4' of the slab perimeter Crawl Spaces: Crawl Space Floor: A minimum of 10 millimeter cross-laminated polyethylene is installed on the floor Polyethylene joints are overlapped a minimum of 6" and taped High traffic areas of the crawl space are lined with foam board on top of the polyethylene Polyethylene installed on the floor is extended a minimum of 12" up on piers or foundation walls General: Advanced Framing Techniques were used where possible Insulation of exterior walls is installed in substantial contact and continuous alignment with the building envelope air barrier Air-permeable insulation is not used as a sealing material Air-permeable insulation is located inside of an air-barrier Batt insulation is cut to fit around wiring & plumbing, or sprayed / blown insulation extends behind piping and wiring Batt insulation is placed between the exterior wall and plumbing pipes / electrical wiring Batts in narrow cavities are cut to fit, or narrow cavities are filled with sprayed / blown insulation All Basement Walls: Installed insulation is a minimum of R-15 Continuous or R-19 Cavity Cavity Insulation R-Value Continuous Insulation R-Value A vapor barrier is not installed over air-permeable insulation on below grade walls Crawl Space Walls: Installed insulation is permanently attached to walls Installed insulation is a minimum of R-15 Continuous or R-19 Cavity Cavity Insulation R-Value Continuous Insulation R-Value Crawl Space is conditioned (un-vented) Rim Joist: Installed insulation is a minimum of R-19 cavity + R-5 continuous rigid exterior foam + interior air barrier Cavity Insulation R-value Continuous Rigid Exterior Foam R-Value Corners and Headers: located in exterior walls are insulated Wood Frame Walls: Installed Insulation is a minimum of R-13 cavity + R-5 continuous rigid exterior foam Cavity Insulation R-value Continuous Rigid Exterior Foam R-Value Iowa Green Streets Version 4.0 - Checklist Page 1 of 7

Pre-Drywall / Thermal Inspection Mass Frame Walls: Installed insulation is a minimum of Zone 5: R-13 / 17 & Zone 6: R-15 / 20 Mass Insulation R-Value / Floors (Cantilevers, Framed Floors Above Garages): Installed insulation is installed to maintain permanent contact with underside of and subfloor decking (cavity is completely filled) Installed insulation is a minimum of R-30 - Floor R-Value Floor R-Value Thermally Isolated Sunrooms: Installed insulation must be a minimum of R-13 Wall and R-24 Ceiling Wall R-Value Ceiling R-Value THE FOLLOWING AREAS ARE FULLY INSULATED, AIR-SEALED & HAVE A RIGID AIR-BARRIER INSTALLED SEPARATING THEM FROM THE EXTERIOR WALL: Breaks or joints in the air barrier are filled or repaired Dropped Ceilings / Soffits Showers and tubs on exterior walls (non-paper faced) Fireplaces on exterior walls Attic Knee Walls Skylight Shafts Dead Spaces and Double Walls Common Walls between dwelling units Air barrier extends behind electrical / media boxes or air-sealed type boxes are installed on exterior walls THE FOLLOWING ITEMS THAT PENETRATE THE THERMAL ENVELOPE MUST BE AIR SEALED AND / OR BLOCKED WITH A RIGID AIR-BARRIER: Duct Shafts Electrical Wiring Flue Shafts Chases Plumbing Pipes All Joints and Seams Rim Joist Junction & Junction of Foundation and Sill Plate Between the garage and conditioned spaces HVAC register boots are sealed to subfloor or drywall All holes and any additional sources of infiltration Iowa Green Streets Version 4.0 - Checklist Page 2 of 7

Windows and Doors: Pre-Drywall / Thermal Inspection Fiberglass insulation is not stuffed around windows and doors Space between windows and framing is caulked or foamed Space between skylights and framing is caulked or foamed Space between door jambs and framing is caulked or foamed Windows are ENERGY STAR Rated (NFRC sticker present for residential) Windows have a maximum U-Factor of 0.30 Doors have a minimum value of R-5 U-Factor R-Value Lighting: Recessed lighting fixtures that penetrate the thermal envelope are airtight, ICAT Rated, Labeled ASTM E 283 Attic / Ceiling: A minimum of a 14" Raised Heel Truss is used Heel Height A minimum of an 18" blocker on the sides of skuttle is installed (If located in conditioned space) Exhaust Venting: Bath fans are vented to the outside Clothes dryers are vented to the outside Kitchen exhaust is vented to the outside HVAC & Piping Insulation: All duct work (supply and return) seams & joints are sealed with mastic and/or UL 181 approved tapes or sealants All duct work located in unconditioned spaces is insulated to a minimum of R-8 HVAC supply or return ducts (cavities) located in a garage to house cavity are insulated to a minimum of R-6 The R-6 insulation is located between the supply or return duct (cavity) and the garage Ground-source heat pumps and boilers, piping is insulated to a minimum of R-3 Radon: A minimum of a passive radon system is installed and labeled Contamination Sources: Large openings in the structure are covered with rodent and corrosion proof screens Date Capillary Break Inspection Completed Date Slab Inspection Completed Date Thermal Inspection Completed Name and Signature of HERS Conducting Capillary Break Inspection Name and Signature of HERS Conducting Slab Inspection Name and Signature of HERS Conducting Thermal Inspection Iowa Green Streets Version 4.0 - Checklist Page 3 of 7

Carbon Monoxide & Combustion: Hard wired CO alarms are installed outside all sleeping areas Wood burning fireplaces are sealed / have gasketed doors / outdoor combustion air Garage: No HVAC equipment is installed in the garage House to Garage door is gasketed or weather stripped House to garage door has an automatic closer CO alarm is installed inside the house on the wall that is attached to the garage Lighting: Recessed Lighting that penetrates the thermal envelope has been gasketed and or sealed to the drywall A minimum of 75% of interior lighting installed is energy efficient lighting (i.e. cfl, LED) Percentage of lighting that is energy efficient All common areas lighting is ENERGY STAR labeled fixtures, LEDs or T8 fixtures with electronic ballasts or better Residential Bathroom Exhaust: ENERGY STAR bath fans are installed Bath fans are connected to a light switch and equipped with one of the following: Humidistat Sensor Timer Occupancy Sensor Delay Off Switch Ventilation Controller Intermittent Bath Fans tested to exhaust at a minimum of 50 cfm Record Tested Fan cfms Fan 1 Fan 2 Fan 3 Fan 4 OR Continuous Bath Fans tested to exhaust a minimum of 20 cfm Record Tested Fan cfms Fan 1 Fan 2 Fan 3 Fan 4 OR Central Ventilation system with roof fans up to 300 design cfm are installed with direct-drive and variable-speed control with speed controller mounted near the fan OR Central Ventilation system with roof fans between 300-2000 design cfm are installed with direct-drive, and variable-speed control, and electronically commutated motors, with speed controllers mounted near the fan Non-Residential Bathroom Exhaust: ASHRAE ventilation standard 62.1-2010 for commercial and institutional buildings was met or exceeded Residential Kitchen Exhaust: A power-vented fan or range hood is installed and vented to the outdoors Kitchen Fan tested to exhaust a minimum of 100 cfm Record Tested Fan cfms Kitchen Fan cfm Iowa Green Streets Version 4.0 - Checklist Page 4 of 7

Residential Kitchen Exhaust Continued: OR Power-vented fans or range hoods with exhaust vented to the outdoors at a continuous rate of 5 ACH based on kitchen volume Kitchen volume Fan cfm ACH OR Central Ventilation system with roof fans up to 300 design cfm are installed with direct-drive and variable-speed control with speed controller mounted near the fan OR Central Ventilation system with roof fans between 300-2000 design cfm are installed with direct-drive, and variable-speed control, and electronically commutated motors, with speed controllers mounted near the fan Non-Residential Kitchen Exhaust: ASHRAE ventilation standard 62.1-2010 for commercial and institutional buildings was met or exceeded Residential Water-Conserving Fixtures: Toilets = 1.28 gpf or less Urinals = 0.5 gpf or less Showerheads = 1.75 gpm or less Kitchen Faucets = 2.0 gpm or less Bathroom Faucets = 1.5 gpm or less Non-Residential Water-Conserving Fixtures: Toilets = 1.6 gpf or less Urinals = 0.5 gpf or less Public Lavatories = 0.5 gpf or less at 60 psi Showerheads = 1.75 gpm or less Kitchen Faucets = 2.0 gpm or less Bathroom Faucets = 1.5 gpm or less gpf gpf gpf gpf gpf Appliances: ENERGY STAR labeled dishwasher is installed: Manufacture ENERGY STAR labeled refrigerator is installed: Manufacture ENERGY STAR labeled washer is installed: Manufacture Model # Model # Model # Clothes Dryer has a built-in moisture sensor Ventless dryer is installed Heating / Cooling and Mechanical Ventilation: A copy of the Manual J & D has been received Iowa Green Streets Version 4.0 - Checklist Page 5 of 7

Heating / Cooling and Mechanical Ventilation Continued: A Programmable, Setback Thermostat with 2 or more temperate settings is installed - These settings go down to a minimum of 55 degrees and up to 85 degrees. One thermostat must be installed for each HVAC System (Not applicable on heat pumps) Mechanical Ventilation system has been balanced and tested to meet ASHRAE Standard 62.2 # of Thermostats Ventilation Type Ventilation Rate Requirement Tested and Ventilation Rate The Following Heating Systems Minimum Efficiency Ratings Must Be Met Natural Gas - Forced Air-Furnace - 92 AFUE Natural Gas - Boiler - 90 AFUE Electric - Forced-Air - Air-Source Heat Pump - 8.5 HSPF Electric - Ground-Source Heat Pump (Closed Loop) - 3.3 COP Electric - Ground-Source Heat Pump (Open Loop) - 3.6 COP The Following Cooling Systems Minimum Efficiency Ratings Must Be Met Electric - Forced-Air - Central Air Conditioners - 14.5 SEER Electric - Forced-Air - Air-Source Heat Pump - 14.5 SEER Electric - Ground-Source Heat Pump (Closed Loop) - 14.1 EER Electric - Ground-Source Heat Pump (Open Loop) - 16.2 EER AFUE AFUE HSPF COP COP SEER SEER EER EER Water Heating: Water heaters have a drain or catch pan with drains piped to the exterior of the dwelling Water heaters located above conditioned space have a catch or drain pan installed Drain pans are sloped and corrosion resistant (stainless or plastic) Non-water sensitive floor coverings are located in the water heater room Exposed cold and hot water pipes are insulated to a minimum of R-3 The Following Natural Gas Water Heater Minimum Efficiency Ratings Must Be Met (If Applicable) Power Vented Up to 60 gallons -.67 EF EF 60-80 gallons -.85 TE TE Tankless -.80 EF Condensing - 90% TE EF TE The Following Electric Water Heater Minimum Efficiency Ratings Must Be Met (If Applicable) 40 gallon -.93 EF EF Circulation Hot Water Systems (If Applicable) Piping must be installed to a minimum of R-3 Equipped with an Automatic Manual Switch for Pump Iowa Green Streets Version 4.0 - Checklist Page 6 of 7

Ceiling / Attic: Ceilings are insulated to a minimum of R-49 Insulation R-Value Attic Doors, Knee-Wall Doors, or Drop-Down Stairs are insulated to a minimum of R-20 Rigid Foam on the top of the skuttle, drop down stairs or back of knee wall doors. Testing: R-Value Installed A Blower Door test was performed and a maximum infiltration rate of 4 ACH50 was reached Person Conducting Blower Door Test ACH50 A Duct Blaster test was performed and a maximum of 4% duct leakage to the outside was reached Person Conducting Duct Blaster Test % of DLO A Minimum HERS Index of 70 was reached ASHRAE 90.1-2010 was exceeded by 15% HERS Index % Exceeded A TOTAL SYSTEM SAVE Performance test was conducted and the Total SAVE Score was 85% or higher Person Conducting SAVE Test SAVE Score Exposed Ductwork or Boiler Systems SAVE Equipment Performance Score Date Completed Name and Signature of HERS Conducting * This completed checklist along with the below listed items must be completed by the HERS and submitted to IEDA: Appendix E for certification form Appendix F for certification form IECC Code Certificate HERS Certificate SAVE Score By signing below I attest that all the items on this checklist have been verified and meet the intent of Iowa Green Streets Criteria. All required inspections were completed and all information contained in this checklist is accurate. Name and Signature of Responsible Party Name of Organization Iowa Green Streets Version 4.0 - Checklist Page 7 of 7