CONSULTING PROJECT LOCATION

ROOF DETAIL RD-16 CONSTRUCTION DOCUMENTS - PHASE / PENNSYLVANIA HOUSING FINANCE AGENCY/ MAY 22, 2017 MURRAY ASSOCIATES ARCHITECTS, P.C.

University of Colorado Colorado Springs. National Cybersecurity Center Roof Replacement Package CSNA Project Number

Site Data. Site Area per Bedroom 450 square feet per bedroom. Site Area: 13,132 s.f.

The Reconstruction of the Tony Dapolito Recreation Center 1 Clarkson Street New York, NY March 20, 2018

ATTACHMENT 2 DRC Page 1 of 13

SPACE TYPE: OUTSIDE PARKING (STRUCTURE)

WCU ALUMNI TOWER MASONRY & ENVELOPE REPAIRS

G0.1 BURR OAKS SENIOR HOUSING. Architecture & Engineering: Dimension IV Madison Design Group 6515 Grand Teton Plaza, Suite 120 Madison, WI 53719

Building Systems and Design Elements included in SliDeRulE

RESIDENTIAL NEW CONSTRUCTION PLAN REVIEW CHECKLIST

Item 2.3 Unit pricing GC to provide a square foot unit cost for material and labor to replace plywood decking beneath new concrete walkway slab.

The Ashland Project. Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage

Overall Existing Conditions Summary

OAK TREE LIQUOR STORE

Framing Methods Structural Components

TABLE OF CONTENTS DIVISION 1 GENERAL REQUIREMENTS

TP: 89'-0" BP: 86'-6 1/4" 2'-0" Typ TP: 89'-0" BP: 86'-6 1/4" 2'-0" Typ S201 TW: 89'-0" TF: 86'-0" S201 TW: 87'-11 1/4" S201 TF: 86'-10 1/4" S201

NEW ILLUMINATED LED SIGNAGE PAINTED STOREFRONT W/ VINYL GRAPHIC AND NEW LED SIGNAGE PAINT FINISHES (PROVIDE (2) COATS FOR ALL PAINTING) PT-1

Building Excellence IV Capital Levy Projects Under Construction

AIRWAYS CROSSING PHASE II BUILDING INFORMATION 5305 McCall Way N.E. T2E 7N7

Administrative Changes

Building Excellence IV Capital Levy Projects Under Construction

See attached sketches showing clarifications to Gaylord Entry Roof and Bridge Roof per review and on site and with Central States Roofing.

EXISTING CONDITIONS BTA PROJECT NO: 1722

New Raised Courtyard Terrace Pavers and Retaining Walls. Line of Steps Above. New Wood Framed Stair

Residential Building Inspections

TABLE OF CONTENTS Public Safety Building

Accellent Cardiology Expansion Brooklyn Park, Minnesota EXTERIOR ENCLOSURE - PART Exterior Wall Construction

GARAGE MAIN FLOOR PLAN

ADDENDUM 2 - JULY 14, 2015

Connection Design Assistance Manual

2003 International Residential Building Code

EXW3 EXISTING DOWEL NEW FOOTING TO EXISTING WALL WITH 3-15M DOWELS, DOWEL THE NEW

Building Architecture

Custom 22' x 40' - 16' Tall Garage Plan #g227 By SDS-CAD Specialized Design Systems

EAST 128TH AVENUE CASE NUMBER: DP XXXX-XXX 7 V 12" 14" Engineering Associates, Inc. SHEET NUMBER F W

Seattle Public Schools Building Excellence IV Projects Under Construction

SGN+A Planning Architecture Landscape Architecture

MAYMONT FOUNDATION ARCHITECT 1840 WEST BROAD ST SUITE 400 RICHMOND, VA

J.DAVID POUNDER LIMITED CONSULTING ENGINEER AND ARCHITECT

Custom 30 x 48-14' Tall Garage Plan #g226 By SDS-CAD Specialized Design Systems

Wall Panels. Structural wall panel. Architectural wall panel. Cladding wall panel. Sandwich wall panel

On Cold-Formed Steel Construction. Light Gauge Steel Engineers Association Washington, D.C Toll Free (866)

MAIN FLOOR PLAN. #G x 14 x 8 Shed - Chicken Coop By SDS-CAD Specialized Design Systems 10'-0" 3'-0" 1'-0" 14'-0" 14'-0" 1'-0" 6'-0" 3'-0"

UCC Permit Application Procedures

HIGHLANDVIEW CEMETERY CHAPEL

One and Two Family Additions

Re.: Dollar Tree D10236 Startown Crossing, Newton, NC Structural Report on Findings, Site Visit (September 21, 2016)

SFR SUBMITTAL REQUIREMENTS

260,000 SF Building Profile

C P A. Presented By Jason G. Smith, CCM, LEED AP. Founder and Principal of Construction Analysis and Planning, LLC

DATE: 4/1/2014 SCALE: 3/16"=1'- 0" SHEET:

SITE / BUILDING PLAN 10/18/16 10/18/16 A+M ARCHITECTS, LLC REINF. ANGLE REQUIRED AT ALL ROOFTOP UNITS WHERE "X" EXCEEDS 8"

Staff Review Date: May 11, 2016 HDC # PID# , ,

SECTION WOOD FRAMING. A. Includes But Not Limited To 1. Furnish and install wood framing and blocking as described in Contract Documents.

MCCARTY ARCHITECTS, P.A. POST OFFICE BOX 440 / 533 WEST MAIN STREET TUPELO, MS / FOR ANSWERS TO QUESTIONS CONTACT: JUSTIN HARRINGTON

6'-0" G-4 ADJUSTABLE SHELVING 2'-0" 4'-5" MOP SINK STORAGE '-0" 2'-0" 26'-6" G-4 6' X 4' OPENING WITH SHUTTER BASE CABINETS 34" FOR ADA 20'-0"

Minimum Residential Plan Submittal Requirements

HILLVIEW ELEMENTARY ADDITIONS AND ALTERATIONS Grove City Area School District

ADDITIONS BUILDING AND ZONING REQUIREMENTS (REVISED 4/22/2008)

One & Two Family Residential ADDITIONS

Building Excellence IV Capital Levy Projects Under Construction

I.C.E. BLOCK (U.S. Patent No. 4,223,501) Detail Manual

WeatherSmart Air Barrier Installation Guide

APPENDIX 3E HAZELWOOD HOTEL SPECIFICATIONS

CITY OF HAGERSTOWN PLANNING & CODE ADMINISTRATION DEPARTMENT. Submittal Requirements

GARAGE MAIN FLOOR PLAN

PROGRAM COST MODEL. for. PEER Tall Buildings Study Concrete Structural Option Los Angeles, California

Update on FCPS Construction/Renovation Projects. June 2016

ARTICLE 12 INTERNATIONAL RESIDENTIAL CODE 2012 International Residential Code Modification Summary (Statutory Authority: 1976 Code Section )

APPLICATION AND CERTIFICATE FOR PAYMENT

GENERAL BUILDING CODE AND ZONING REQUIREMENTS: Post and spread footings shall be designed and constructed below the minimum frost depth of 42 inches

* RESIDENTIAL PLAN REVIEW *

THE SPENCER RESIDENCE J&S ARCHITECT

Nortrax Section David Manchester Road, Ottawa NON-STRUCTURAL METAL FRAMING 16 May 2014 Page 1

Roof Replacement. Notes: T-1 (Title Page) 709 Bull Street Columbia, South Carolina. University of South Carolina. Callcott Social Science


EXTERIOR WALLS. exterior wall systems, cladding w/ masonry. chapters SUBJECT

Lonsdale Building Inspections Department 415 Central Street W. PO Box 357 Lonsdale, MN (507) fax (507)

East Lyme Middle School EAST LYME MIDDLE SCHOOL


RESIDENTIAL BUILDING PLAN REQUIREMENTS

Pulaski County, Virginia

SECTION FABRICATED ENGINEERED STRUCTURES. A. Pre-engineered, shop-fabricated structural steel building with formed purlin framing.

Building Envelope

INFORMATIONAL HANDOUT FOR FINISHING A BASEMENT


Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi

Expanding Your Development & Investment Perspectives 159,000 SF Building Profile

TABLE OF CONTENTS Updated 1/2014 SECTION TITLE DATE

DIVISION 5 - STRUCTURAL STEEL AND IRON WORK

ARTSPACE LOFTS - DMC DESIGN REVIEW OCTOBER 21, 2015

SUBJECT: NEW 2000 INTERNATIONAL RESIDENTIAL CODE (IRC) DATE:

Section : 100 TRESHOLD STAIRS DEPARTMENT NGL HALLWAY TOWARDS MUSEUM FFL DISABLED WC FEMALE WC MALE WC FFL 95.

SECTION GYPSUM BOARD

GARAGE MAIN FLOOR PLAN

DIVISION 07 THERMAL AND MOISTURE PROTECTION ROOFING

NEWS LETTER MARCH 27, 2009

COOK COUNTY ILLINOIS CONTRACT FOR WORK DOCUMENT NO Countywide Warehouse and Records Storage Center Hawthorne Project TKB No.

Transcription:

Urban Design Submittal s 12 ebruary 2007 Owner Developer W. Mifflin St. STATE CAPITOL SQUARE Meriter Retirement Services, LLC 333 West Main Street 53703 W. Washington Ave. S. airchild St. STATE CAPITOL Architects Planners SIMONSON GERMANY NONEMAKER + ASSOCIATES, INC. 1190 West Druid Hills Drive, Suite T-65 Atlanta, Georgia 30329 Telephone (404) 634-4466 S. Broom St. W. Main St. W. Doty St. S. Henry St. Project Site W. Wilson St. S. Hamilton St. S. Carroll St. CITY / COUNTY BUILDING STATE OICE BLDG Martin Luther King Jr. Blvd. E. Doty St. MADISON MUNICIPAL BUILDING E. Wilson St. S. Pinckney St. North Location Map Interior Architecture BROWNHOUSE 202 W. Gorham Street Madison, WI 53703 MEP & Structural Engineers ARNOLD & O'SHERIDAN 1111 Deming Way, Suite 200 Madison, WI 53717

Meriter Heights Building West Doty Street Henry Street South Broom Street West Main Street Architectural Site Plan Scale: 1" = 30'-0" ebruary 12, 2007 A1

Covered Entry Reconfigured Exterior Seating Vestibule Expanded Seating Lobby Existing Pharmacy Cart & Buggy Storage Existing Toilet Room Existing Toilet Room Existing Exercise Existing Elevator Lobby Renovated Henry Street Lobby Plan Scale: 1/4" = 1'-0" ebruary 12, 2007 A2

Existing Residential Scale: 1/8" = 1'-0" ebruary 12, 2007 A3

show as 6' door with trim Unit Type B2 1206 Unit Type B2 1202 Unit Type B3 1204 E E Unit Type C 1205 Unit Type B1 Unit Type A 1201 1203 Proposed Renovations-s 12 & 14 Scale: 1/8" = 1'-0" ebruary 12, 2007 A4

Unit Type B2 1506 Unit Type B2 1502 Unit Type B3 1504 E E Unit Type C 1505 Unit Type B1 Unit Type A 1501 1503 MIDVALE PLAZA JOINT VENTURE May 17, 2006 Proposed Renovations- 15 Scale: 1/8" = 1'-0" Midvale Plaza Redevelopment and MSTSD

22'-0" 22'-0" 21'-11" 20'-0" 24'-1" 3'-1" 20'-0" 21'-10" 22'-0" 22'-1" 18'-0" 31'-0" B8 18'-4" 19'-5" 14'-3" New concrete where smoke hatch was removed. See Structural for connection and reinforcing New roof drain New steel stair with concrete treads from floor below New 6" CMU stair wall. See Structural for connection and reinforcing 3'-4" 17'-6" 13'-6" 29'-4" 9'-8" B9 Cooling Tower New steel beam framing to carry new mechanical equipment. See Structural. Column, below Existing RTU to remain 2'-6" 1'-1" Location of existing roof drain. Existing ladder to remain E B3 B2 B1 Expansion E Tank E P1 P2 New concrete where stair was removed. See Structural for connection & reinforcing E 9'-8" Existing ACCU, 40 Tons. 2'-6" 6'-7" 3'-4" 45'-4" 3'-4" Existing roof drain to remain Existing smoke hatch to remain Shroud and fan for bathroom exhaust stacks. Typical, 16 locations. 22'-10" 24'-0" 21'-0" 3'-4" 23'-0" 22'-0" 19'-4" Penthouse/Roof Plan Scale: 1/8" = 1'-0" ebruary 12, 2007 A6

Existing elevator penthouse. New weather resistant ventillation louver. Duct back to existing louver New EIS parapet wall New mechanical screen wall. Steel stud and EIS veneer. Reinforced CMU wall with EIS veneer. Existing Elevator Penthouse 198'-6 1/2" New Mechanical Screen 190'-8 1/2" Capitol View Limit 187'-2 1/2" 3'-6" Aluminum fascia Single hung windows w/insulating glass and insect screens New cantilevered decks with metal guardrails on steel tube & cable support system Glass spandrel panel Aluminum panels Alternate 1: EIS veneer with control joints at same locations Bent metal intermediate cornice line. Existing window to remain Existing concrete wall Existing brick veneer Existing score joints Existing spandrel and HVAC to remain Existing concrete to remain Paint or stain existing concrete Aluminum fascia Pre-finished metal wrap Wall mounted light to match MainGate Commons Double wythe cast stone wall with precast concrete cap. 9'-0" Existing storefront with sloped metal roof Existing canopy Existing planter Existing skylights Line of planter grade, not shown for clarity 6'-5" 13 loors @ 8'-8 1/2" 12'-0" 12'-0" 12'-0" 113'-2 1/2" 9'-0" Existing Roof 179'-2 1/2" 15th 14th 12th 11th 10th 9th 8th 7th 6th 5th 4rd 3nd 2nd 1st Ground Aluminum panels Cast Stone base with precast band Basement Steel beam canopy Henry Street Elevation Scale: 3/32" = 1'-0" ebruary 12, 2007 A7

Existing penthouse. Reinforced CMU wall with EIS veneer. Existing penthouse. Aluminum fascia New metal stud with EIS veneer mechanical screen wall, beyond. Aluminum fascia Single hung windows w/insulating glass and insect screens Aluminum panels Alternate 1: EIS veneer with control joints at same locations Single hung windows w/insulating glass and insect screens Aluminum panels Alternate 1: EIS veneer with control joints at same locations New cantilevered decks with metal guardrails on steel tube and cable support structure New cantilevered decks with metal guardrails on steel tube and cable support structure Bent metal intermediate cornice line. Existing score joints Bent metal intermediate cornice line. Existing score joints Existing concrete wall Existing concrete wall Existing Lobby Doty Street Elevation Scale: 3/32" = 1'-0" Wests Main Street Elevation Scale: 3/32" = 1'-0" ebruary 12, 2007 A8

Existing Penthouse scsreen wall Existing elevator lobby New mechanical screen wall. Steel stud and EIS veneer. Reinforced CMU wall with EIS veneer. Aluminum fascia Aluminum panels Alternate 1: EIS veneer with control joints at same locations Single hung windows w/insulating glass and insect screens New cantilevered decks with metal guardrails on steel tube and cable support structure Existing score joints Spandrel glass Built up EIS banding and intermediate cornice line. Single hung windows w/insulating glass and insect screens Aluminum panels Existing concrete wall Existing brick veneer Existing concrete to remain Paint or stain existing concrete Existing Lobby Courtyard Elevation Scale: 3/32" = 1'-0" ebruary 12, 2007 A9

Waterproof roof membrane over tapered insualtion with minimum thickness to achieve R30. Extend membrane up wall and underneath cap flashing. 8'-8 1/2" 8'-8 1/2" 8'-8 1/2" 5'-8" 6'-9 5/8" 1'-11 1/4" 6'-9 5/8" 1'-11 1/4" 6'-9 5/8" 1'-11 1/4" 8" reinforced CMU parapet wall. with aluminum panel veneera at facade. Rear wall shall receive paint. See Structural for attachment to existing concrete slab. Spring lock clip flashing at perimeter Waterproof roof membrane over tapered insualtion with minimum ithickness to achieve R38. Extend membrane up wall 12" minimum. See 3/A7.1 for dimensions and notes on steel tube frame. 5/8" gypsum board on metal furring to conceal conduit and sprinkler piping run tight to underside of slab. Precast concrete slab with sloped top. Top shall receive 45 mil waterproof textured traffic topping. Bottom to receive paint. Provide 4 steel embed plates at bottom, 2 front, 2 rear and centered on 4x8 tubes for attachment. See Structural. Heavy commercial aluminum sliding door with thermally broken frame, insulating glass & insect screen. Deck rails not shown for clarity 8'-8 1/2" 8'-8 1/2" 8'-8 1/2" 1 1/2" 4'-11 1/2" 3'-9" 4'-11 1/2" 3'-9" 4'-11 1/2" 3'-9" 1" 5'-5" 1" 5'-5" 4 1/4" 1/2" 11 1/2" 4'-2" 1" 5'-5" 1/2" 11 1/2" 4'-2" 4" 1" 3" 2" 1 1/2" 2'-7 1/2" 1 1/2" 4" 1/2" steel plate, profile as indicated. Weld to steel tube with 3/16" fillet, full length, each side. Drill hole to receive pin of threaded coupling. 4"x12"x3/8" steel bearing plate. Weld to steel tube and epoxy bolt to slab using 2, 3 / 4" ø bolts with 3 1 / 2" embedment Steel tie rod with threaded coupling each end 1/2" steel plate, profile as indicated. Weld to steel tube with 3/16" fillet, full length, each side. Drill hole to receive pin of threaded coupling. 4"x8"x3/8" steel tube beam 4"x12"x3/8" steel tube with end cap. Provide one at each side of deck Precast deck not shown for clarity 4"x8"x3/8" steel tube beam Typical guardrail at each level, not shown for clarity. Core drill and epoxy posts into slab. Precast concrete deck sloped from 5 1 / 2" at building face to 4 1 / 2" at outer edge. 4"x4"x3/8" steel angle attachment clip, each side. Weld to tube with continuous 3/16" fillet. 3"x3"x5/16" steel tube. 3'-7 1/2" 4"x12"x3/8" steel tube bottom chord with end cap 6x6x 3 / 8" steel angle, 12" length. Weld to end of 4x12 tube with continuous 3 / 16" fillet. Epoxy bolt to slab using 2, 3 / 4" ø bolts with 3 1 / 2" embedment 8'-8 1/2" 8'-8 1/2" 8'-8 7/8" 6'-9 1/4" 1'-11 1/4" 6'-9 1/4" 1'-10 7/8" 6'-9 1/4" 1'-10 7/8" Aluminum panel. Provide backer rod & sealant at joint w/window. TYP. SINGLE HUNG WINDOW TYP. EXTERIOR WALL WITH ALUMINUM PANEL VENEER 5/8" gypsum board on metal furring to conceal conduit and sprinkler piping run tight to underside of slab. Spandrel glass in heavy commercial, thermally broken aluminum frame. Metal stud header. See Structural. ill header with R19 batt insulation. Bent metal flashing over 3 / 4" exterior grade plywood sheathing on 6" metal studs @ 16" o.c. Extend flashing up wall, 12" minimum. Double stud edge at window locations. Anchor to cornice with kickers at each end. Prefinished aluminum drip flashing Bent metal w/flat lock seam at bottom & screw attachment at top. Bent metal cornice with kickers, beyond 12'-6" 2'-6" 8'-0" 3'-0" Coordinate louver size with Mechincal sub-contractor and actual equipment 1'-4" 8" 6" 1'-0" luid cooler on vibration isolation dampers. Coordinate with Mechanical sub contractor Prefinished aluminum cap flashing over pressure treated blocking EIS over exterior sheathing on 6" metal studs @ 16" o.c. Backer rod & sealant. Prefabricated louver. Coordinate size with Mechanical contractor. EIS over exterior sheathing on 6" metal studs @ 16" o.c. Steel support beams 60 Mil liquid applied waterproof membrame Existing concrete roof deck 5/8" gypsum board on metal furring to conceal conduit and sprinkler piping run tight to underside of slab. Wall Section at Decks Scale: 3/4" = 1'-0" Structural Section at Decks Scale: 1/2" = 1'-0" Wall Section at Mechanical Screen Scale: 3/4" = 1'-0" Wall Section at Windows Scale: 3/4" = 1'-0" ebruary 12, 2007 A10