Pro-panel Cement Board Technical Guide

Similar documents
Exterior Wall Solutions Building Shell

USG Tile & Flooring Solutions. Lightweight cement board. Easy to cut and fasten. Faster installation USG DUROCK BRAND CEMENT BOARD INSTALLATION GUIDE

CEMENT BACKERBOARD FOR TILE AND STONE INSTALLATION GUIDE OUR GUIDE TO INSTALLING CEMENT BACKERBOARD DO IT ONCE, DO IT RIGHT. TM

Fire Resistant: Achieves FRL levels of 90/90/90 for load bearing walls.

Manufacturing Systems

Aquaroc Fibre Cement Board

excom (Expressed Panel Facade System) Primary top hat 160 x 35 x 1.0mm mm.

Installation & Specification Manual Board Fixing

Cembrit Windstopper Basic Cembrit Windstopper Extreme

Cl/SfB 1 (4-) RJ July Cempanel BUILDING BOARD CEMENT PARTICLE BOARD.

Installation Guide. HardiePanel Compressed Sheet INTERIOR

MANUFACTURING SOLUTIONS. A Complete Design Build Solution for Residential, Institutional, Commercial and Industrial Buildings.

icore HR outperforms other building boards in many important ways including the following:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIBER-CEMENT SIDING REPORT HOLDER: TAKTL, LLC

DECKING INSTALLATION GUIDE

The GlasRoc Shaftliner Type X advantage...

PRODUCT OVERVIEW NOVEMBER NEW Secura flooring sizes on pages 23 and 25

1 Exam Prep Application and Finishing of Gypsum Board GA Tabs and Highlights

1 Exam Prep Application and Finishing of Gypsum Board GA Tabs and Highlights

PRIMA CERAMIC TILE UNDERLAY. Product. Scope. Building Regulations. Technical Specification. Appraisal No. 636 [2008]

USG Tile & Flooring Solutions. USG DUROCK BRAND CEMENT BOARD WITH EDGEGUARD Installation Guide

Triton BK Backer Board & Tile Underlayment

Container Installation Guide

GA APPLICATION OF GYPSUM SHEATHING

FIRE PROTECTION AND PERFORMANCE DRY LINING BOARD THE ULTIMATE IN FIRE PROTECTION! 91 mins fire integrity and 86 mins fire insulation on 9mm board

FERMACELL Powerpanel H 2 O for Wet & Moisture affected areas

Showcase Your Space. Not Your Access Panel. Product Features. Shop online at or call

STONESHEET TM SUBSTRATE FOR STONE FACADES & EXTERIOR TILING

FIRE PROTECTION AND PERFORMANCE DRY LINING BOARD THE ULTIMATE IN FIRE PROTECTION! 91 mins fire integrity and 86 mins fire insulation on 9mm board

think eco WOOD BOARD Bahan Binaan KELASʻOʼ

Bracing. Design Manual AUGUST 2016 I NEW ZEALAND

The new high-performance lining for internal and external applications INSIDE OR OUT YOUR CHOICE

Contents. Timber framing to be installed in accordance with AS:1684 Metal framing to be installed in accordance with BCA Volume: 2

STUCCO SOLUTION. Technical Specification MAY 2015 I NEW ZEALAND

Container Installation Guide

INSTALLATION MANUAL. METAL INSULATED PANELS -ROXUL -Expanded Polystyrene

Cl/SfB 1 (4-) 1 RJ December 2018 (2) Cempanel. Cement Particle Board - Building board for external and internal applications

Stria CLADDING. Stria CLADDING

Knauf AQUAPANEL Interior Ceiling System

HOW TO: BOARD BATHROOMS, WET ROOMS & SHOWERS

Technical Specification OCTOBER 2013 NEW ZEALAND

Sprayed or Blown Fibre & Ceramic Fibre (Blanket)

Technical Specification Aug 2012

1222 Moonshine Rd, RD1, Porirua 5381 Private Bag Porirua 5240, New Zealand Tel: branz.co.nz. Important Notice

Senergy Reinforcing Mesh

Magnesium Oxide Wallboard

Sheathing Board Xtra protection, built in.

STONESHEET TM STONE TILE SUBSTRATE

QuietRock 530 RF Application Notes

DURASCAPE TM BASE SHEETS

Non- Combustible Sheathing Board for Steel Frame applications

SECTION GLASS FIBER REINFORCED GYPSUM FABRICATIONS

TWPC DECKING INSTALLATION GUIDE

Siding and Soffit Installation Guidelines

Knauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap

Patent Application No :

Magnum Board Section Digicon Information Inc. Page 1

Architectural Specifications

Siding and Soffit Installation Guidelines

Cl/SfB l (42) Rf9 l l May Cembrit HD. Rainscreen cladding/building board for external applications. 1

Brick Veneer Walls. Insulation

Gold Bond BRAND Gypsum Sheathing

Proudly Made in the U.S.A. 5-Year Warranty. Wayfinding Products

nu-wall aluminium vertical cladding system

PermaBase BRAND Cement Board

Design No. HI/BP PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table 1

HOW TO: CREATE METAL PARTITIONS WALL LININGS AND CEILINGS GTEC FRAMES

EQUITONE is a material supplier. Installation Contractors shall be trained and approved by EQUITONE.

TECHNICAL MANUAL. Wall System Descriptions and Building Details. May 13, 2013 V1.3

Magnum Board Section Digicon Information Inc. Page 1

ICBO Evaluation Service, Inc Workman Mill Road, Whittier, California

Impression Graphic panels

Textura Façade panel Product information sheet 1

Installation Guide. HardieBreak Thermal Strip COMPONENTS

FOCAL POINT RENDAPANEL TM CLADDING SYSTEM

nu-wall direct fixed Product BRANZ APPRAISAL No. 557 (2007) Scope Aluminium Product Brands NZ Limited 15 Gabador Place Mt Wellington Auckland

EQUITONE is a material supplier. Installation Contractors shall be trained and approved by EQUITONE.

Resysta Wall Cladding Installation Guidelines

NU-WALL ALUMINIUM VERTICAL CLADDING SYSTEM. Product. Scope. Appraisal No. 556 [2007] Appraisal No. 556 (2007) Amended 20 November 2015.

DuraComp Composite Decking Installation Guide. Hidden Plastic Clip Fixing

Introduction. Applications. Everest Facade Advantages

Senergy Reinforcing Mesh

For more information on Pictura visit CI/SfB (41) R December New. Pictura. High performance cladding

A M E R I C A N A R C H I T E C T U R A L M A N U F A C T U R E R S A S S O C I A T I O N

PROMATECT fi 250 PROMAXON fi Technology Steelwork Fire Protection

SECTION GYPSUM BOARD & SHEATHING SYSTEMS

February savolitplus. natural building boards for sustainable construction

For more information about performance, installation, warranties and warnings:

Project No: Pakenham Branch Library, Pakenham, Ontario Section DECEMBER, 2016 Page 1 of 6

Tundra is created from New Zealand plantation Douglas Fir heart wood. Width x Thickness (mm) Approx. Cover. Vertical Shiplap

Gold Bond BRAND Kal-Kore Plaster Base

Technical Data Sheet

SECTION GYPSUM BOARD ASSEMBLIES

SECTION GYPSUM BOARD

inspiration 's component

Asbestos cement products in your home

AcroWall-ES System. Class PB Exterior Insulation and Finish System providing a primary moisture barrier. Typical Details

Cement Particle Board

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIBER CEMENT SIDING REPORT HOLDER: RIEDER FASERBETON ELEMENTE GmbH

Knauf Aquapanel Interior. System Solutions Tile Backing. Cement board for wet areas. Quick and simple to construct

Transcription:

Pro-panel Cement Board Technical Guide Pro-panel Cement Board Technical Guide for Cold Formed Steel Construction Complies with; ASTM C1186 BS 476 ASTM G-21 www.framecad.com

Building Products and Supply Chain Logistics for our Global Customers FRAMECAD has been successfully serving the world s building industry for more than 25 years. Our expert team combines the know-how from over 900 combined years of global experience. FRAMECAD puts this experience to work to help our customers succeed. With FRAMECAD Certified Building Products and world class supply chain logistics, you can turn architectural inspiration into commercial reality much faster and more cost effectively than ever before. FRAMECAD Building Products specialises in developing and supplying global customers with materials that are fit for purpose, tested, designed and engineered by our in-house engineers and technicians that enable of modern methods of construction. Our focus has always been on developing practical building products and solutions that streamline the steel framed building design and build process, cutting production time and delivering a better end result.

Contents: FRAMECAD Pro-panel cement board Product Information Product Certification Page 1 Pro-panel Board Sizes Page 2 Properties of FRAMECAD Pro-panel cement board Page 3 Storage and Handling Page 4 Cutting Page 5 Installation - For FRAMECAD Cold Formed Steel frames FRAMECAD Specified Fasteners (X-Drive ) Page 6 Detail Drawings Door Installation Page 7 Window Installation Page 8 Render jointing System Page 9 Internal and External Corner Page 10 Opening (Door/Window) Page 11 Health and Saftey Page 12

FRAMECAD Pro-panel cement board FRAMECAD Pro-panel cement board is a high density sheet ideally suited for exterior cladding, interior lining and Flooring FRAMECAD Pro-panel cement board complies with; ASTM C1186-08:2002 (Type B) - Density - Flexural Strength - Moisture absorption, EQ moisture content and moisture movement BS 476 - Class A (GB 8624-1997) - Reaction to fire - No failure at 120 minutes ASTM G-21 - Non nutrient to mould, fungus or insect life Manufacturing FRAMECAD Pro-panel cement board is a strong and flexible board composed of Portland Cement, refined ores, and reinforced cellulose fibre as the main materials. It is made under high temperature and pressure which generates a light weight, durable and smooth-faced board for various applications. FRAMECAD Pro-panel cement board is a light weight energy saving building panel with non-asbestos fibre that is treated by high temperature and high pressure autoclave process, in accordance with ISP 9001. Page 1

Applications Ideal for Cold Formed Steel residential and commercial constructions. Applications include; Exterior Wall Cladding Interior Linings Soffits Gable Ends Sizes and packaging Metric Dimensions Application Imperial Dimensions Application Thickness (inch) Width (Ft) Length (Feet) 8 9 10 12 Approximate Packaging Per 20 container Soffit / Ceiling 3/16 4 900 Sheets Ceiling / Lining 1/4 4 900 Sheets Lining / Cladding Exterior Siding (Wood Grain) Thickness (mm) Width (mm) Length (mm) 2400 2700 3000 3600 3/8 4 710 Sheets 1/2 4 530 Sheets. 5/16 4 2000 Sheets... Approximate Packaging Per 20 container Soffit / Ceiling 4.5 1200/1220 900 Sheets Ceiling / Lining 6 1200/ 1220 900 Sheets Lining / Cladding Exterior Siding (Wood Grain)......... 9 1200/1220 710 Sheets 12 1220/1220 530 Sheets. 8 210/310 2000 Sheets... Flooring 18 1200/1220 355 sheets......... Flooring 7/8 4 355 sheets FRAMECAD Pro-panel is available in a range of imperial and metric dimensions. If not listed as above please contact us with your inquiry. NOTE: FRAMECAD Pro-panel 6mm (1/4 ) and 9mm (3/8 ) also available with a tapered edge (TE) or square edge (SE). Either touch fit or leave a maximum gap of 2mm between boards which is later filled using the FRAMECAD Mineral Render System. Page 2 Pro-panel Cement Board 2014 Copyright 2014 FRAMECAD Ltd. All rights reserved

Physical Properties Item Parameter Item Parameter Density > 1200 kg/m 3 Biological No Fungus Growth Diagonal & Thickness Tolerance +/- 0.4mm Water Absorption 29.5% Moisture Movement 0.054% Transverse 11MPa Bending Strength Shrinkage (Dried) 0.1% Vertical 8.5 MPa Expansion (Soaked) 0.15% Screw Pullout 70N (9mm thickness) Moisture Content 10% Impact Resistance 1500 J/m 2 ph 10 Thermal Conductivity 0.17 w/mk Fire Resistance When FRAMECAD Pro-panel cement board is used in conjunction with FRAMECAD Cold Formed Steel Framing there are two very significant advantages. 1. LGS being non-combustible, when fire burns through the linings it will not spread within the framing cavity, whereas this is a major cause of hidden fire spread in timber framing. 2. Steel Framing does not increase the fire load. Timber is combustible and there is at least 20kg of timber per square metre of floor area in a timber framed house. This is 75% of the design fire load of a houses content, which means that a timber framed house is carrying at least 1.75 times the fire load of a steel framed house. The higher the fire load, the more severe the fire. Therefore it is not surprising that fire case histories show steel houses perform very well in house fires, with little or no damage to the framing structure. Furthermore if steel framed members are not visibly distorted they can be left in place, cleaned and if necessary recoated. If they are distorted then they need to be replaced. When FRAMECAD Pro-panel cement board is used for Fire Rated Systems the stud spacing must not exceed 400mm c/c (center to center) and nogs 800mm c/c. Refer to Clause 6.4 in the Fire and Acoustic Design Manual for further guidance on fire rating. The steel framing must be suitably coated to satisfy the Durability requirements of clause B2 of the New Zealand Building Code (NZBC) and other applicable building standards. Item Index Unit Fire Resistance BS 476 Fire test on building materials and structures No failure at 120 minutes Page 3

Storage and Handling It is the responsibility of the builder to ensure that the product meets aesthetic requirements before installation. FRAMECAD will not be responsible for rectifying obvious aesthetic surface variations following installation. FRAMECAD pro-panel cement board must be stored flat on a smooth surface. Precaution should be taken that edges and corners are protected from damage. Ensure that all sheets are stored under cover and kept dry. If Sheets become wet they must be dried prior to installation. Carry sheets in the vertical position as this will avoid bending and possible breakage. Page 4

Cutting FRAMECAD Pro-panel cement board Score and Snap: Score on the face side of the product. Score against a straight edge and repeat the action to obtain adequate depth for a clean break - normally 1/3 of the sheet thickness Snap upwards to achieve the break, smooth any rough edges with a rasp Guillotine: Mark sheet with a straight cut line on the underside of the sheet that is to be cut. Following this line, guillotine cut on the off-cut side of line to allow for the thickness of the blade. Sawing The saw blade used with a dusk reducing saw and vacuum extraction allows for fast, clean cutting of FRAMECAD Pro-panel cement board. Alternatively, FRAMECAD recommends the use of a wet saw, with a full dust extraction system. When sawing, clamp a straight-edge to the sheet as a guide and run the saws base plate along the straight edge when making the cut. A hand saw offers ability to make small cuts and notches. For accuracy and neatness mark out lines on the face side of the sheet prior to sawing. A quick jabbing motion provides the best result. Forming a Hole: For smooth clean cut circular holes: Mark the center of the hole on the sheet. Pre-drill a pilot hole. Using the pilot hole as a guide, cut the hole to the appropriate diameter with a hole saw fitted to a electric drill. For irregular holes: Small rectangular or circular holes can be cut by drilling a series of small holes around the perimeter of the hole then tapping out the waste piece from sheet face. Tap carefully to avoid damage to sheets, ensuring that the sheet edges are properly supported. Page 5

Installation - For Cold Formed Steel Frames FRAMECAD Recommend the following Fastenings to install FRAMECAD Pro-panel cement board. FRAMECAD X-Drive screws are self-embedding ensuring a flush finish SPECIFICATIONS FRAMECAD Part # 030149 (Loose) 030193 (Loose) 308335 (Loose) 030150 (Loose) Name 8g X Clad Thick 5mm 8g X Clad Thick 40mm 8g X Clad Thick 35mm 10g X Clad Thick 45mm Gauge 8g (4.2mm) 8g (4.2mm) 8g(4.2mm) 10g (4.8mm) Head Type Countersunk (CSK) Countersunk (CSK) Countersunk (CSK) Countersunk (CSK) Drive Type X Drive #1 X Drive #1 X Drive #1 X Drive #1 Tip Type Winged Drill Point (WDP) Winged Drill Point (WDP) Winged Drill Point (WDP) Winged Drill Point (WDP) TPI 16 16 18 16 Length (mm) 35 40 35 45 Colour Grey / Green Grey / Green Grey / Green Grey / Green Speed Recommendation (RPM) 2500 2500 2500 2500 Coating Class AS3566.2 2002 3 3 3 3 Salt Spray Results (hours) ASTM B117 1000 1000 1000 1000 Kesternich Results (cycles) DIN 50018 2.0L 15 15 15 15 For further details on the FRAMECAD Fastening Range please refer to the FRAMECAD Fastenings Catalogue. FRAMECAD Pro-panel cement board is typically installed on a C section size of: 89mm x 41mm x 0.75mm / 0.95mm / 1.15mm / 1.55mm When fixing to FRAMECAD C sections fastenings should be fixed as close as possible to the web side of studs to ensure screw engagement. FRAMECAD Pro-panel cement board must be placed firmly against the frame when fixing to ensure breakout does not occur on the back. Screw located too far from web, causing bending of flange and a loose fixing of the cladding Screw located close to the web, ensuring a tight fix to the cladding Page 6

FRAMECAD Pro-panel Cement Board FRAMECAD Cold Formed Steel Wall Frame FRAMECAD Pro-panel Cement Board FRAMECAD 030149 X-Drive 35mm Winged Drill Point Screw spacing at 300mm centers FRAMECAD 030149 X-Drive 35mm Winged Drill Point Screw positioned 50mm from corners and 12mm from sheet edge Page 7

FRAMECAD Cold Formed Steel Wall Frame FRAMECAD Pro-panel Cement Board FRAMECAD 030149 X-Drive 35mm Winged Drill Point Screw spacing at 300mm centers FRAMECAD 030149 X-Drive 35mm Winged Drill Point Screw positioned 50mm from corners and 12mm from sheet edge Page 8

FRAMECAD Pro-panel Cement Board FRAMECAD Pro-panel Cement Board FRAMECAD 030149 X-Drive 35mm Winged Drill Point Screw FRAMECAD 308716 75mm Jointing Mesh FRAMECAD Mineral Render System, refer to FRAMECAD Technical Specification for full details about FRAMECAD Minerial Render System FRAMECAD Mineral Render System, refer to FRAMECAD Technical Specification for full details about FRAMECAD Minerial Render System Page 9 Pro-panel Cement Board 2014 Copyright 2014 FRAMECAD Ltd. All rights reserved

FRAMECAD Pro-panel Cement Board FRAMECAD Cold Formed Steel Wall Frame FRAMECAD 030149 X-Drive 35mm Winged Drill Point Screw FRAMECAD Mineral Render System, refer to FRAMECAD Technical Specification for full details about FRAMECAD Minerial Render System FRAMECAD Pro-panel Cement Board FRAMECAD Mineral Render System, refer to FRAMECAD Technical Specification for full details about FRAMECAD Minerial Render System Page 10

FRAMECAD 030149 X-Drive 35mm Winged Drill Point Screw FRAMECAD Pro-panel Cement Board Door / Window Frame Page 11

Maintenance Maintenance is the responsibility of the specifier to determine. The extent of any maintenance will be determined by the geographic location and exposure of the building. FRAMECAD recommends the following; Wash exterior surfaces every 6-12 months Reapply paint finish as necessary Ensure all joints, flashings and sealants are maintained to ensure any means of moisture entering beyond the exterior cladding are stopped. Clean gutters and pipes and overflows as needed Prune back vegetation so that it is not touching the cladding Note: FRAMECAD do not recommend the use of a Water Blaster Health and Safety FRAMECAD Pro-panel is manufactured from cement, refined ores and reinforced cellulose fibre. As manufactured the product will not release airborne dust, but during drilling, cutting and sanding operations cellulose fibres, silica and calcium silicate dust may be released. Breathing fine silica dust is hazardous, prolonged exposure (usually over several years) may cause bronchitis, silicosis or cancer. If using power tools for cutting, drilling or sanding they must be fitted with an appropriate dust collection devices and/or used an approved dust mask and wear safety glasses. These precautions are not necessary when stacking, unloading or handling fibre cement products. For further information please contact FRAMECAD www.framecad.com Safe Working Practices Do not breathe dust and cut only in well ventilated areas. FRAMECAD Pro-panel sheets contain and silica which is considered by some authorities as a cause for cancer. Breathing excessive amounts of dust can harm and potentially cause lung disease. Ensure that work is performed in well ventilated areas Reduce dust when cutting by using a score and snap knife or by using a dust reducing saw. Be aware and inform others when cutting is taking place so that they can avoid dust inhalation. Always wear a proper fitting and approved dust mask or respirator. Page 12

This document is current as at May 2014 and supersedes all previous versions of the FRAMECAD Pro-panel Technical Guide. The material in this document is provided for general information purposes only. Although all reasonable efforts have been made to ensure that the information is current and accurate as at the date of issue, the information provided is selective and may not be complete or suitable for your intended use or jurisdiction. No information in this document constitutes, or shall be relied upon as constituting, the giving of advice of any nature. Nor is any such information to be used as a substitute for specific advice from appropriate independent professional advisors in your jurisdiction regarding your particular facts and circumstances or as a substitute for compliance with the requirements of applicable regulatory authorities or laws. You should not act (or refrain from acting) based upon information provided by FRAMECAD without independently verifying the original source information and, making your own independent assessment, with the assistance of appropriate independent professional advisors, regarding your particular facts and circumstances. FRAMECAD makes no representation or warranty, express or implied, as to the accuracy, completeness or suitability for purpose, of any information in this document. To the extent permitted by law, FRAMECAD accepts no responsibility to the recipient or any other person for any loss, damage, cost or expense (whether direct or indirect) incurred and arising out of or in connection with any use or reliance by any of them on the information in this document including, but not limited to, as a result of any error, omission or misrepresentation in any information or statement in this document. This limitation of liability includes but is not limited to incidental, special or consequential damages, damages for loss of business or other profits. Liability which cannot legally be excluded is limited to the maximum extent possible. FRAMECAD Ltd, logos and Trademarks are the property of FRAMECAD Ltd. Copyright 2014 FRAMECAD Ltd. Reproduction of any part of this document is prohibited, except with the prior written consent of FRAMECAD Ltd. We have offices here: Auckland, New Zealand (Head Office) Dubai, UAE Dallas, USA Hong Kong Melbourne, Australia Johannesburg, South Africa www.framecad.com English - Pro-panel Cement Board