DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: ROOF PANELS REPORT HOLDER: ROSER CO., LTD.

Similar documents
REPORT HOLDER: FEROOF CO., LTD SEONWON LI SEONNAM MYEON SUNGJU GUN KYEONGSANGBUK DO SOUTH KOREA EVALUATION SUBJECT:

REPORT HOLDER: RARE MANUFACTURING INC A AVENUE SURREY, BRITISH COLUMBIA V4N 4P2 CANADA EVALUATION SUBJECT: IRONWOOD SHAKE

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE RUBBER SHAKES REPORT HOLDER: DAVINCI ROOFSCAPES, LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: METAL SALES MANUFACTURING CORPORATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF TILES REPORT HOLDER: GERARD ROOFING TECHNOLOGIES EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL SHINGLES REPORT HOLDER: TEFUTE BUILDING MATERIALS COMPANY, LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CLAY ROOF TILES REPORT HOLDER: CERAMICA LA ESCANDELLA, S.A.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: METAL SALES MANUFACTURING CORPORATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CONCRETE ROOF TILES REPORT HOLDER: BARTILE ROOFS, INC. EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOF PANELS REPORT HOLDER: ONDULINE NORTH AMERICA, INC. EVALUATION SUBJECT:

DIVISION: OPENINGS SECTION: UNIT SKYLIGHTS REPORT HOLDER: SKYCO SKYLIGHTS 2995 AIRWAY AVENUE, SUITE B COSTA MESA, CALIFORNIA 92626

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CLAY ROOF TILES REPORT HOLDER: BORAL ROOFING LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: CERTAINTEED CORPORATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING FELT AND UNDERLAYMENT REPORT HOLDER: ENVIRONMENTALLY SAFE PRODUCTS, INC.

DIVISION: OPENINGS SECTION: UNIT SKYLIGHTS REPORT HOLDER: KINGSPAN LIGHT + AIR LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: DERBY BUILDING PRODUCTS INCORPORATED

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP FABRICATED WOOD TRUSSES REPORT HOLDER: BARRETTE STRUCTURAL DISTRIBUTION, INC.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: EVALUATION SUBJECT: STRUCTURAL PANELS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CONCRETE ROOF TILES REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIBER CEMENT SIDING REPORT HOLDER: KMEW CO., LTD. EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: GENTEK BUILDING PRODUCTS, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: SIDING REPORT HOLDER: SHAKERTOWN 1992, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

REPORT HOLDER: MASTER MARK PLASTICS PRODUCTS 210 AMPE DRIVE PAYNESVILLE, MINNESOTA EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIBER CEMENT SIDING REPORT HOLDER: RIEDER FASERBETON ELEMENTE GmbH

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: KAYCAN LTD.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL WALL PANELS REPORT HOLDER: FCP, INC.

DIVISION: METALS SECTION: METAL FASTENINGS REPORT HOLDER: SUZHOU HONGLY HARDWARE CO., LTD.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PLASTICS SECTION: PLASTIC DECKING REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: SIDING REPORT HOLDER: BORAL COMPOSITES, INC.

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH 3000 SERIES FASTENERS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: KP BUILDING PRODUCTS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CLAY ROOF TILES REPORT HOLDER: TEJAS BORJA USA EVALUATION SUBJECT:

ESR-2015P* Reissued April 2014 This report is subject to renewal April 1, 2015.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CONCRETE ROOF TILES REPORT HOLDER: BORAL ROOFING EVALUATION SUBJECT:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: NAILS REPORT HOLDER: BOSTITCH FASTENING SYSTEMS

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER: MITEK USA, INC.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PLASTICS SECTION: PLASTIC RAILINGS REPORT HOLDER: FYPON, LTD.

ICC ES SYSTEM SYSTEM. Trusted DIVISION: 07 SECTION: AND FINISH REPORT HOLDER: ICC-ES Evaluation. Reissued 08/2016.

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH 5000 SERIES FASTENERS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: FUNDERMAX GMBH

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL WALL PANELS DIVISION: SIDING REPORT HOLDER: VM ZINC

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: PLASTIC DECKING SECTION: PLASTIC RAILINGS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: REFLECTIX INCORPORATED

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: TRESPA NORTH AMERICA, LTD.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PLASTICS SECTION: PLASTIC RAILINGS REPORT HOLDER:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: ENERCEPT, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: SPRAY FOAM POLYMERS

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP FABRICATED WOOD TRUSSES REPORT HOLDER: BARRETTE STRUCTURAL DISTRIBUTION, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: PARKLEX USA

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PLASTICS SECTION: PLASTIC DECKING REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: PRODEMA USA INC. EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FACED PANELS REPORT HOLDER: MEXALIT INDUSTRIAL, S.A. DE C.V.

DIVISION: METALS SECTION: METAL FABRICATIONS REPORT HOLDER: AKRON PRODUCTS COMPANY

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: 3A COMPOSITES USA INC.

DIVISION: METALS SECTION: METAL FASTENINGS REPORT HOLDER: GRABBER CONSTRUCTION PRODUCTS, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING AND SIDING PANELS REPORT HOLDER: KINGSPAN INSULATED PANELS, INC.

REPORT HOLDER: R.L. ADAMS PLASTICS, INC CROSSROADS COMMERCE PARKWAY WYOMING, MICHIGAN EVALUATION SUBJECT: POLYCORE BRAND INSULATION

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PLASTICS SECTION: PLASTIC DECKING REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS SECTION: AIR BARRIERS

DIVISION: METALS SECTION: METAL FABRICATIONS REPORT HOLDER: QUALITY WAY PRODUCTS, LLC 407 HADLEY STREET HOLLY, MICHIGAN 48442

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PLASTICS SECTION: PLASTIC DECKING REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS/WEATHER BARRIERS

REPORT HOLDER: UNITED DURALUME PRODUCTS, INC. EVALUATION SUBJECT: DURACOOL COMPOSITE STRUCTURAL INSULATED PANELS

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PLASTICS SECTION: PLASTIC RAILINGS REPORT HOLDER:

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH BRAND FASTENERS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: ASSOCIATED MATERIALS, INC.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: PLASTIC DECKING SECTION: PLASTIC RAILINGS REPORT HOLDER:

REPORT HOLDER: LOUISIANA-PACIFIC CORPORATION 414 UNION STREET, SUITE 2000 NASHVILLE, TENNESSEE EVALUATION SUBJECT:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: NAILS REPORT HOLDER: HY-TEK FASTENERS INC. EVALUATION SUBJECT: HY-TEK NAILS

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD I JOISTS REPORT HOLDER: STARK TRUSS COMPANY, INC.

ESR-3284 Reissued August 1, 2011 This report is subject to renewal August 1, 2013.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: 3A COMPOSITES USA INC. EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: RIDGE VENTS REPORT HOLDER: VERSCENE, INC.

DIVISION: SPECIALTIES SECTION: PROTECTIVE COVERS REPORT HOLDER: FOUR SEASONS BUILDING PRODUCTS, LLC EVALUATION SUBJECT:

DIVISION: FINISHES SECTION: GYPSUM BOARD ACCESSORIES REPORT HOLDER: GRABBER NAILS FOR GYPSUM WALLBOARD INSTALLATION

REPORT HOLDER: HUBER ENGINEERED WOODS, LLC ONE RESOURCE SQUARE DAVID TAYLOR DRIVE, SUITE 300 CHARLOTTE, NORTH CAROLINA 28262

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: NCFI POLYURETHANES

REPORT HOLDER: SOPREMA, INC. 310 QUADRAL DRIVE WADSWORTH, OHIO EVALUATION SUBJECT:

REPORT HOLDER: BLUE POINT FASTENING, INC YORBA COURT CHINO, CALIFORNIA EVALUATION SUBJECT:

DIVISION: FINISHES SECTION: GYPSUM BOARD ACCESSORIES REPORT HOLDER: CONLAB, INC. dba PREST ON CO.

DIVISION: FINISHES SECTION: SUSPENSION SYSTEMS SECTION: ACOUSTICAL CEILING SUSPENSION ASSEMBLIES REPORT HOLDER:

Joint Evaluation Report

REPORT HOLDER: BASF CORPORATION EVALUATION SUBJECT: MASTERSEAL AWB 660 I VAPOR RETARDER, AIR AND WATER-RESISTIVE BARRIER AND FLEXIBLE FLASHING

REPORT HOLDER: PAREX USA, INC EAST LA PALMA AVENUE, SUITE 250 ANAHEIM, CALIFORNIA EVALUATION SUBJECT:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: FOUR SEASONS SOLAR PRODUCTS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: NCFI POLYURETHANES EVALUATION SUBJECT:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PLASTICS REPORT HOLDER: INTEPLAST GROUP CORPORATION EVALUATION SUBJECT:

REPORT HOLDER: JAACO CORPORATION NE 68 TH STREET, SUITE C 130 REDMOND, WASHINGTON EVALUATION SUBJECT:

DIVISION: METALS SECTION: METAL RAILINGS REPORT HOLDER: ULTRALOX 2955 LONE OAK DRIVE, SUITE 180 EAGAN, MINNESOTA 55121

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: ARCONIC ARCHITECTURAL PRODUCTS, LLC

DIVISION: MASONRY SECTION: MANUFACTURED BRICK MASONRY SECTION: MANUFACTURED STONE MASONRY REPORT HOLDER:

DIVISION: METALS SECTION: METAL FASTENINGS REPORT HOLDER: CLARKDIETRICH BUILDING SYSTEMS LLC

Joint Evaluation Report ICC-ES (800) (562)

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COATED FOAM ROOFING REPORT HOLDER: COVESTRO, LLC

Transcription:

0 Most Widely Accepted and Trusted ICC-ES Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-1763 Reissued 05/2017 This report is subject to renewal 05/2018. DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION SECTION: 07 41 13 METAL ROOF PANELS SECTION: 07 41 00 ROOF PANELS REPORT HOLDER: ROSER CO., LTD. 400 NAE-RI, APRYANT-MYEON GYEONGSAN, GYEONGBUK 38539 KOREA EVALUATION SUBJECT: ROSER STEEL AND COPPER ROOFING PANELS Look for the trusted marks of Conformity! 2014 Recipient of Prestigious Western States Seismic Policy Council (WSSPC) Award in Excellence A Subsidiary of ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright 2017 ICC Evaluation Service, LLC. All rights reserved.

ICC-ES Evaluation Report www.icc-es.org (800) 423-6587 (562) 699-0543 ESR-1763 Reissued May 2017 This report is subject to renewal May 2018. A Subsidiary of the International Code Council DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION Section: 07 41 00 Roof Panels Section: 07 41 13 Metal Roof Panels REPORT HOLDER: ROSER CO., LTD. 400 NAE-RI, APRYANT-MYEON GYEONGSAN, GYEONGBUK, 38539 KOREA +82-53-817-5000 www.roser.com EVALUATION SUBJECT: ROSER STEEL AND COPPER ROOFING PANELS 1.0 EVALUATION SCOPE 1.1 Compliance with the following codes: 2012, 2009, and 2006 International Building Code (IBC) 2012, 2009, and 2006 International Residential Code (IRC) 2013 Abu Dhabi International Building Code (ADIBC) The ADIBC is based on the 2009 IBC. 2009 IBC code sections referenced in this report are the same sections in the ADIBC. Properties evaluated: Roof covering Wind resistance Fire classification 1.2 Evaluation to the following green code: 2016 California Green Building Standards Code (CALGreen), Title 24, Part 11 Attributes verified: See Section 3.1 2.0 USES The Roser Steel and Copper Roofing Panels described in this report are metal roof panels complying with IBC Section 1507.5 and IRC Section R905.4 that are used in Class A roof covering assemblies when installed over new and existing roofs. 3.0 DESCRIPTION 3.1 Steel Panels: The steel panels have a base-metal thickness of 0.0157 inch (0.40 mm) and are formed from aluminum-zinc alloy coated structural quality sheet steel complying with ASTM A792 and having an AZ50 (AZM150) coating designation. On the exposed surface of the steel panels, stone granules are embedded into an acrylic resin adhesive emulsion. See Figure 1 for panel profiles. The attributes of the metal roof panels have been verified as conforming to the provisions of CALGreen Section A5.406.1.2 for reduced maintenance. Note that decisions on compliance for those areas rest with the user of this report. The user is advised of the project-specific provisions that may be contingent upon meeting specific conditions, and the verification of those conditions is outside the scope of this report. These codes or standards often provide supplemental information as guidance. 3.1.1 Roser Bond, Tuscany Tile and Cleo: The Roser Bond, Tuscany Tile and Cleo panels are 16.14 inches (410 mm) wide by 53.15 inches (1350 mm) long, with an exposure of 14.57 inches (370 mm). The installed weight is approximately 1.5 psf (7.3 kg/m 2 ). 3.1.2 Spany: The Spany steel panels are 16.14 inches (410 mm) wide by 52.56 inches (1335 mm) long, with an exposure of 14.57 inches (370 mm). The installed weight is approximately 1.5 psf (7.3 kg/m 2 ). 3.1.3 Rowood and Stonewood Shake: The Rowood and Stonewood Shake panels are 16.14 inches (410 mm) wide by 52.76 inches (1340 mm) long, with an exposure of 14.57 inches (370 mm). The installed weight is approximately 1.5 psf (7.3 kg/m 2 ). 3.2 Copper Panels: The Spany Copper panels have a copper thickness of 0.0197 inch (0.50 mm) and conform to ASTM B370. The panels are 16.14 inches (410 mm) wide by 52.56 inches (1335 mm) long, with an exposure of 14.57 inches (370 mm). The installed weight is approximately 1.35 psf (6.59 kg/m 2 ). See Figure 1 for a panel profile. 4.0 DESIGN AND INSTALLATION 4.1 General: Installation of Roser roofing panels must comply with this report, the manufacturer s published installation instructions, and the applicable code. The manufacturer s published installation instructions shall be available at the jobsite at all times during installation. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright 2017 ICC Evaluation Service, LLC. All rights reserved. Page 1 of 5

ESR-1763 Most Widely Accepted and Trusted Page 2 of 5 4.2 New Construction: 4.2.1 Support Conditions: The roofing panels must be installed on roofs having a slope of 3:12 (25%) or greater. Roof rafters must have a minimum specific gravity of 0.42 and shall be spaced not more than 24 inches (610 mm) on center. Roof panels must be installed over solid sheathing complying with the applicable code. 4.2.2 Underlayment: Underlayment must comply with Section 1507.5.3 of the IBC or Section R905.4.3 of the IRC, as applicable. 4.2.3 Batten Installation: Battens must be nominally 2-by-2 lumber having a minimum specific gravity of 0.42 and a moisture content not exceeding 19 percent. Battens must be installed perpendicular to the rafters at 14 5 / 8 inches (370 mm) on center in accordance with the manufacturer s instructions. Battens must be fastened to each rafter with the fasteners specified in Table 1 of this report. 4.2.4 Panel Installation: Upper panels must lap lower panels at the lower vertical face of each batten. The fasteners specified in Table 1 must be installed through the two plies of panel into this face of the batten. See Figures 4, 5 and 6 for typical installation details. Panel side laps must be approximately 2 3 / 8 inches (60 mm). Panel side laps in adjacent courses must be staggered a minimum of one pan or impression [approximately 7.5 inches (191 mm)]. Valley flashing must comply with IBC Section 1507.5.6 or IRC Section R905.4.6, as applicable. See Figure 7. Roof openings must be flashed in accordance with IBC Section 1503.2 or IRC Section R903.2, as applicable. See Figures 8 and 9. Openings through the roof for vents, etc., must be waterproofed and supported by additional blocking or roof framing as required by the code. At gable edges, a continuous rake cap or barge cover of the same material as the panels, supplied by Roser, must be installed in accordance with the manufacturer s published installation instructions. See Figure 10. At hips and ridges, panels must be cut, bent and installed, and hip and ridge caps of the same material as the panels, supplied by Roser, must be installed in accordance with the manufacturer s published installation instructions. See Figures 2, 3 and 6. 4.3 Reroofing Applications: Roser roofing panels must be installed over existing roofs in accordance with Section 1510 of the IBC and Section R907 of the IRC. 4.3.1 Support Conditions: Roofing panels must be installed on roofs having a slope of 3:12 (25%) or greater. Roof rafters shall have a minimum specific gravity of 0.42 and must be spaced not more than 24 inches (610 mm) on center. 4.3.2 Counterbatten Installation: Counterbattens must be nominally 1-by-4 boards having a minimum specific gravity of 0.42 and a moisture content not exceeding 19 percent. Counterbattens must be installed over the existing roofing, parallel with and directly over the existing rafters. Counterbattens must be nailed at 12 inches (305 mm) on center with minimum 16d common nails having sufficient length to penetrate 1 inch (25.4 mm) into the rafter. 4.3.3 Batten Installation: Battens must be nominally 2-by-2 lumber having a minimum specific gravity of 0.42 and a moisture content not exceeding 19 percent. Battens must be installed perpendicular to the counterbattens and rafters at 14 5 / 8 inches (370 mm) on center per the manufacturer s instructions. Battens must be fastened to each rafter using fasteners with the minimum sizes as specified in Table 1 of this report and having sufficient length to penetrate 1 1 / 2 inches (38 mm) into the rafter. 4.3.4 Panel Installation: Panel installation must be the same as for new construction. See Section 4.2.4. 4.4 Allowable Negative Wind Pressures: Roser roofing panels must be installed where the negative design wind pressure, determined in accordance with Section 1609 of the IBC or Section R301.2.1 of the IRC, as applicable, does not exceed the allowable negative wind pressure specified in Table 1 of this report. 4.5 Fire Classification: When installed in accordance with this section and Sections 4.1 through 4.3, Roser steel and copper roofing panels are recognized as Class A or Class B roof assemblies in accordance with IBC Section 1505.2 and IRC Section R902.1. 4.5.1 Steel Panels: Spany, Roser Bond Rowood, Tuscany, and Stonewood Shake used as Class A roof coverings must be installed in accordance with this report and the manufacturer s installation instructions over minimum 15 / 32 -inch-thick (11.9 mm) plywood followed by one layer of GAF Corporation Versashield Fire Resistant Roof Deck Protection followed by 2-by-2 wood battens. 4.5.2 Steel and Copper Panels: Spany, Roser Bond, Rowood, Tuscany, and Stonewood Shake, used as Class B roof coverings, must be installed in accordance with the manufacturer s installation instructions over minimum 15 / 32 - inch-thick (11.9mm) plywood followed by 2-by-2 wood battens covered with one layer of Type G3 mineral surface cap sheet and 1-by-4 wood battens mechanically fastened to the 2-by-2 wood battens, with the metal panels mechanically fastened to the 1-by-4 wood battens. 5.0 CONDITIONS OF USE The Roser steel and copper roofing panels described in this report comply with, or are suitable alternatives to what is specified in, those codes listed in Section 1.0 of this report, subject to the following conditions: 5.1 The panels are manufactured, identified and installed in accordance with this report, the manufacturer s published installation instructions and the applicable code. In the event of a conflict between the installation instructions and this report, this report governs. 5.2 Use is limited to roofs with slopes of 3:12 (25%) or greater. 5.3 The panels are manufactured in Korea under a quality control program with inspections by ICC-ES. 6.0 EVIDENCE SUBMITTED Data in accordance with the ICC-ES Acceptance Criteria for Metal Roof Coverings (AC166), dated October 2012. 7.0 IDENTIFICATION Each pallet of Roser roofing panels must be identified by a label with the manufacturer s name (Roser Co.); the name of the additional listee, if applicable; the product name; the plant location; the date of manufacture; and the evaluation report number (ESR-1763).

ESR-1763 Most Widely Accepted and Trusted Page 3 of 5 TABLE 1 ALLOWABLE NEGATIVE WIND PRESSURES PANEL TYPE PANEL TO BATTEN FASTENERS 1,2 BATTEN TO RAFTER FASTENERS 3 ALLOWABLE NEGATIVE WIND PRESSURE (PSF) Spany Copper Roser Bond, Tuscany Tile, Cleo, Spany Steel, Rowood, Stonewood Shake 5 - No. 8 1 1 / 2 " long hex head screws 5 - No. 8 x 1 1 / 2 " long hex head screws No. 10 3 1 / 2 " long screw 60 No. 10 3 1 / 2 " long screw 63 Roser Bond, Tuscany Tile, Cleo, Spany Steel, Rowood, Stonewood Shake 5-8d nails 16d common nail 53 For SI: 1 inch = 25.4 mm, 1 lbf/ft 2 = 0.047 kpa. 1 Fasteners for stone-coated steel panels shall be galvanized steel. 2 Fasteners for copper panels shall be 300 series stainless steel. 3 Fastener sizes given are the minimums for application to new construction. Fasteners of battens to rafters through existing roofs must be of sufficient length to penetrate the rafter 1 1 / 2 inches (38 mm).

ESR-1763 Most Widely Accepted and Trusted Page 4 of 5 ROSER BOND, TUSCANY TILE AND CLEO ROWOOD, STONEWOOD SHAKE

ESR-1763 Most Widely Accepted and Trusted Page 5 of 5