: Industrial Boiler MACT: CEM Requirements. Dan Kietzer: SICK Process Automation

Similar documents
Process Optimization & Plant Safety

Particulate CEMs for Wet and Dry FGD applications. By William Averdieck, Managing Director, PCME Ltd, UK

Particulate Matter (PM) CEMS

CEMS FOR COAL FIRED POWER STATIONS DEVICE CALIBRATION AND MAINTENANCE

John Downs Environmental Manager, B&W PGG, KVB-Enertec Products. January 29, 2015

PM Compliance Options for MACT and MATS Rules. Ed McCall PCME

Fully Extractive Vs. Dilution Extractive CEMS

Calibration of Light Scatter PM-CEMs to Satisfy PS-11 on Wet Stacks in Coal Fired EGUs

CONTINUOUS EMISSION MONITORING SYSTEM. Copyright Adage Automation Pvt Limited

Continuous Emissions Monitoring in Support of the Cement MACT

PRODUCT CONFORMITY CERTIFICATE

BOILER MACT 40 CFR 63 DDDDD

Update on EPA s Rulemakings Affecting Biomass-Fired Boilers

CEM. Continuous Emission Monitoring Systems NACT 221. Course Overview. National Air Compliance Training. CEM implementing regulations

TUV Certified FTIR CEM and Ultra Low Level HCl CEM for Combustion Facilities

CEMS for Measurement of Ammonia, SO 3, and Low Level NOx

Comparison Continuous Emission Monitoring Techniques

Industrial Boiler MACT Rule Impact and Control Options for Mercury and Dioxins/Furans

Online data sheet MCS100E HW-C CEMS SOLUTIONS

PRODUCT CONFORMITY CERTIFICATE

INTHUU MEASUREMENTS CC

GAS ANALYZERS. Digital Manometer

Mercury Monitoring in a Cement Kiln

Technical Guidance Note (Monitoring) Monitoring of stack gas emissions from medium combustion plants and specified generators

Flue gases content measurement after electrostatic precipitators

Can your unit pass a Particulate Emission Compliance Test?

Energy Production Systems Engineering

Pollution Control Solutions Using Spray Technology

PRODUCT CONFORMITY CERTIFICATE

EuroFID Total Hydrocarbon Analyzer

Development of Air Pollutants Treatment System for Industrial Processes using Petroleum Coke

Technical Guidance Note (Monitoring) Medium Combustion Plant Directive and Generator Controls: monitoring point source emissions

Boiler MACT & Related Rules. Western Regional Boiler Association 45 th Annual Meeting Portland, Oregon March 14, 2013

GEOENERGY WET ESPS FOR BOILER MACT APPLICATIONS

ABSTRACT INTRODUCTION

Internal Recirculation Circulating Fluidized-Bed Boilers

Combustion Control and Safety A comparison between Zirconium Oxide/Catalytic and Tunable Diode (TDL) Technologies Dr Stephen Firth / Rhys Jenkins

Fluid Bed Scrubbing TECHNOLOGY

Dekati Solutions. Emission Measurements

CASE STUDIES OF DUST AMS CALIBRATION AT EXTREME CONDITIONS

Continous Emission Monitoring: Methods, Regulations and QA/QC. Anders Arvidsson, Opsis AB, Sweden

Continuous Emissions Monitoring - Program 77

PRODUCT INFORMATION MCS100E HW/PD/CD MULTICOMPONENT ANALYZER SYSTEMS EMISSION AND RAW GAS MONITORING WITH HOT MEASUREMENT.

Activated Carbon Injection for Mercury Control on Industrial Coal-Fired Boilers

Minimizing Ammonia Consumption in DeNOx Plants In situ Laser Gas Analyzer LDS 6 Monitors NH 3 Slip in Real-time

New Requirements for the Measurement of Ammonia Emissions

INTHUU MEASUREMENTS CC

Controlling Emissions and Saving Money with Highly Engineered Cartridge Filter Technology

Online Infrared Flue Gas Analyzer Gasboard 3000

ABSORPTION MEASURING INSTRUMENT

Dan Deatsch Thompson Environmental Consulting

Mist eliminators for Flue Gas Desulphurization

The development of instrumentation for application to carbon capture and storage measurements

Volume Flow and Gas Flow Measuring Devices

Sorbents Evaluation Testing Facilities. 95% removal efficiency or an emission standard of lbs/gw h by 2012, while

CISWI and solid-waste-identification rules

High efficient multi-fuel CYMIC concept for biomass, rejects and coal for Hamburger Hungaria Katriina Jalkanen Valmet Technologies Oy

A Higher Standard of Monitoring Systems & Customer Service

Case Study: Pulse Jet Fabric Filter & Dry Sorbent Injection for Biomass Boiler Application

Uppgradering av rökgasreningssystem

A Comparison of Proposed PM CPMS Limits

CEM Gilles Gonnet Ecomesure, B.P. 13, F Briis Sous Forges, France telephone: fax:

ZP Series of Small, High-sensitivity Infrared Gas Analyzers

Process Analytical and Continuous Emissions Monitoring Systems

PRODUCT CONFORMITY CERTIFICATE

COAL POWER COAL BURNING POWER PLANTS

Worldwide Pollution Control Association

INTHUU MEASUREMENTS CC

Compact flue gas analyser: testo 300 M-I

The Value Proposition of Circulating Fluidized Bed Scrubbing Technology. Robert Giglio Foster Wheeler Global Power Group

CEMENT PLANT ENVIRONMENTAL TECHNOLOGY FOR ACHIEVING HIGH SO 2 REMOVAL

Industrial and Institutional Boilers after Boiler MACT

Update on ICI Boiler MACT

The Filterautomat. Our Filter Systems Protect. The New Definition of Purity for Your Medium. flow rate 5 m 3 /h to 4,000 m 3 /h. filter fineness 5 µm

Worldwide Pollution Control Association

DAILY LIFE of CEMS QA & PM

Boiler MACT Compliance Plan and Strategies Financial Impacts & Capital Expenditures Required to Meet U.S. EPA s NESHAP Rule for Industrial Boilers

Ray Chalmers - EPA Region III

Commercial and Industrial Solid Waste Incinerator (CISWI) Rules Final Reconsidered Rules Requirements Summary

Reducing the Cost of Compliance and Improving Plant Operations for Coal-Fired Boilers

Enhanced Dust Collector Performance Evaporative Gas Conditioning

Robust flue gas probes for industrial emissions measurements.

Biofuels GS 2 Measuring Course Part II, DTU, Feb 2 6, 2009 Experiments in the entrained flow reactor

This document is a preview generated by EVS

Enhancing Performance Improving Combustion Efficiency Reducing Plant Emissions Including Advanced NOx & SOx Reduction. Ammegen.

Southwest Clean Air Agency NE 99 th St, Suite 1294, Vancouver, WA 98682

Boiler panel protection technology. The best solutions and service with WA Integra

Application of Circulating Fluidized Bed Scrubbing Technology for Multi Pollutant Removal

Boiler MACT, 40 CFR Part 63, Subpart DDDDD (5D) Question and Answers. General (Q1 Q9)...2. Applicability (Q10 Q22)...4

PRODUCT CONFORMITY CERTIFICATE

Integrating ADAir Mixer Technology to Optimize System Performance with DSI Applications

Assessment of Bias in Measurement of Mercury Emissions from Coal Fired Power Plants Comparison of Electronic CEMS and Sorbent Traps

Particulate and Opacity Control - Program 76

Particulate and Opacity Control - Program 76

PRODUCT CONFORMITY CERTIFICATE

Guidelines for Continuous Emission Monitoring Systems

Dekati Sample Conditioning Instruments

Control Device Technology

MRU Instruments, Inc.

Transcription:

: Industrial Boiler MACT: CEM Requirements Dan Kietzer: SICK Process Automation

: Overview: Boiler MACT

: Testing Boiler MACT Testing and Monitoring Requirement - Initial compliance tests (PM, HCl, Mercury, THC and Dioxins) - Annual performance tests - Annual tune-up for units < 10 MM Btu/hour in size and units in Gas 1 and Metal Process Furnaces subcategories - Allows emission averaging among existing units in same subcategory : Monitoring - CO CEMs for units with heat input capacity of 100 MM Btu/hour or greater - PM CEMs for units combusting coal, biomass, or residual oil and having a heat input capacity of 250 MM Btu/hour or greater - Process parameters (opacity, pressure drop, sorbent injection rate, fuel, etc.) : Continuous Compliance - Demonstrated by maintaining operating limits (process parameters) - Demonstrated by maintaining CEMs values (30 day average) below emission limits : SICK MAIHAK : Confidential : Name (Date) 3

: PM CEMs in Wet and Dry Applications

Measuring Principle Scattered light : Optical principle : When light hits the particle, it is scattered : Relation between the scattered light intensity and dust concentration : Usable for low to medium dust concentrations Diffraction Light Absorption Refraction Reflection : SICK MAIHAK : Confidential : Name (Date) 5

Measuring Principle Scattered light : Light attenuation depends on different application parameters (E.g.: grain size, dust density, dust dispersion) : Application specific regression curve through a gravimetric comparison measurement: cc2e 2 + cc1e + cc0 - Relationship between ma and dust concentration : Data imported into dust measurement device mg/m 3 0 ma (Through Extinction) Fig.: Regression curve (Schematic) : SICK MAIHAK : Confidential : Name (Date) 6

PM CEMs in Wet and Dry Applications Dry gas SP100 Wet gas FWE200 : SICK MAIHAK : Confidential

Dry Stack Application: Forward Scatter - Probe 0 mg/m 3 200 mg/m 3 2 In : Different probe lengths available : High gas temperatures (up to 752 o F) : HASTELLOY material for Corrosive gases : Maintenance interval of 3 months : Powder coated stainless steel housing : Meets EPA Performance Spec 11 < 752 o F : SICK MAIHAK : Confidential : Name (Date) 8

Dry Stack Application: Forward Scatter - Probe Fibre optic cable Receiver Sender Receiver optics : SICK MAIHAK : Confidential : Name (Date) 9

Wet Stack Application Scatter Forward Probe w/ bypass system Why a Bypass System? : The light of the monitor attenuated through particles in the light beam. : The water droplets must be eliminated. : The heated Bypass System is the solution for a correct PM measurement in wet stacks. : SICK MAIHAK : Confidential : Name (Date) 10

Wet Stack Application Scatter Forward Probe w/ bypass system Sample Probe: Gas temperature: 250 F for PVDF Probe 430 F for Hastelloy Probe : SICK MAIHAK : Confidential : Name (Date) 11

Wet Stack Application Scatter Forward Probe w/ bypass system Thermo cyclone: Heater 1 Heater 2 Connection cable for heater and temperature sensor Screw connection : SICK MAIHAK : Confidential : Name (Date) 12

Wet Stack Application Scatter Forward Probe w/ bypass system Function of the measuring cell: Measuring cell Free jet nozzle Sender-/ receiver unit Free jet Laser beam Purge air Purge air Suction nozzle : SICK MAIHAK : Confidential : Name (Date) 13

Wet Stack Application Scatter Forward Probe w/ bypass system Fibre optic cable Receiver Sender Receiver optics : SICK MAIHAK : Confidential : Name (Date) 14

PM CEMs in Wet and Dry Applications : Proven technology : Over 15 years experience with scattered light devices. Scatter Light: : Continuous measurement - real time not mean time measurement : Sensitive to low levels of dust concentration - < 5mg/m 3 - < 1 µm particle size : Usable wet stacks by utilizing a bypass system Forward scattering light Scattering light angle: 15 : SICK MAIHAK : Confidential : Name (Date) 15

: CO CEM

CO CEMs In-situ CO 2 H 2 O CO Temperature Pressure Analyzer Versions Model Component All Temperature GM 35-1 CO GM 35-2 CO, H 2 O GM 35-3 CO, H 2 O, CO 2 GM 35-4 CO, CO 2 GM 35-5 H 2 O, CO 2 GM 35-6 H 2 O GM 35-7 CO 2 : SICK MAIHAK : Confidential

CO CEMs In-situ Zero Point Reflector and blanking disk Reflector - measuring probe IR Source Filter wheel for CO 2 / H 2 O measurement Filter wheel for CO measurement Reference filter : SICK MAIHAK : Confidential

CO CEMs In-situ Analyzer Self Test: Check Cycle : SICK MAIHAK : Confidential

CO CEMs In-situ GPP Probe (Gas Permeable Probe) Flange seal Bellows for filter protection Features: : Temperature measurement : Pressure measurement : Heater controller with special features : Preheated test gas routing : SICK MAIHAK : Confidential

CO CEMs In-situ : Proven technology : Large installed base in US emissions applications : Quick, reliable response : No lag time due to sample transport : No loss in sample system : No sample system to maintain : Integral zero and span capability saves money on cal gas : : SICK MAIHAK : Confidential : Name (Date) 21

: Questions? Dan Kietzer: SICK Process Automation Email: dan.kietzer@sick.com Website: www.sicknorthamerica.com